Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BJOG ; 129(8): 1361-1374, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35243759

RESUMO

OBJECTIVE: To correlate clinical outcomes to pathology in SARS-CoV-2 infected placentas in stillborn and live-born infants presenting with fetal distress. DESIGN: Retrospective, observational. SETTING: Nationwide. POPULATION: Five stillborn and nine live-born infants from 13 pregnant women infected with SARS-CoV-2 seeking care at seven different maternity units in Sweden. METHODS: Clinical outcomes and placental pathology were studied in 14 cases (one twin pregnancy) of maternal SARS-CoV-2 infection with impaired fetal outcome. Outcomes were correlated to placental pathology in order to investigate the impact of virus-related pathology on the villous capillary endothelium, trophoblast and other cells. MAIN OUTCOME MEASURES: Maternal and fetal clinical outcomes and placental pathology in stillborn and live-born infants. RESULTS: Reduced fetal movements were reported (77%) and time from onset of maternal COVID-19 symptoms to signs of fetal distress among live-born infants was 6 (3-12) days and to diagnosis of stillbirth 11 (2-25) days. Two of the live-born infants died during the postnatal period. Signs of fetal distress led to emergency caesarean section in all live-born infants with umbilical cord blood gases and low Apgar scores confirming intrauterine hypoxia. Five stillborn and one live-born neonate had confirmed congenital transmission. Massive perivillous fibrinoid deposition, intervillositis and trophoblast necrosis were associated with SARS-CoV-2 placental infection and congenital transmission. CONCLUSIONS: SARS-CoV-2 can cause rapid placental dysfunction with subsequent acute fetal hypoxia leading to intrauterine fetal compromise. Associated placental pathology included massive perivillous fibrinoid deposition, intervillositis and trophoblast degeneration.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Cesárea , Feminino , Sofrimento Fetal , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas , Placenta/irrigação sanguínea , Gravidez , Complicações Infecciosas na Gravidez/diagnóstico , Estudos Retrospectivos , SARS-CoV-2 , Natimorto/epidemiologia
2.
BMC Pregnancy Childbirth ; 20(1): 347, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503518

RESUMO

BACKGROUND: It is discussed whether fetal scalp stimulation (FSS) test is a reliable complimentary tool to cardiotocography (CTG) to assess fetal wellbeing during labor. The test is based on the assumption that a well-oxygenated fetus, in contrast to the depressed fetus, will respond to a certain stimulus. The aim of this study was to investigate the effectiveness of the FSS-test. METHODS: A retrospective observational study carried out Copenhagen University Hospital, Herlev, Denmark. Laboring women with singleton pregnancies in cephalic presentation after gestation week 33 and indication for fetal blood sampling (FBS) were eligible for inclusion. The FSS-test was classified as positive when an acceleration was absent at the time of FBS and negative when an acceleration was present. Lactate in scalp blood was measured by the point-of-care device LactatePro™ and pH in artery umbilical cord blood by the stationary blood gas analyzer ABL800. Lactate level < 4.2 mmol/L in scalp blood and arterial cord pH > 7.1 were cut-offs for normality. RESULTS: Three hundred eighty-five women were included. The cohort was divided by the FBS-to-delivery time: Group 1 (n = 128) ≤ 20 min, Group 2 (n = 117) 21-59 min and Group 3 (n = 140) ≥ 60 min. The proportion of FSS-positive tests differed significantly between the groups (p < 0.000). In Group 1 the sensitivity, specificity and likelihoods for scalp lactate ≥4.2 mmol/L were 81.5 (95% CI 67-90.1), 13.3 18.5 (95% CI 5.9-24.6), LHR+ 0.94 (95% CI 0.8-1.1) and LHR - 1.4 (95% CI 0.6-3.2) and for umbilical artery pH ≤ 7.10 the values were 82.6% (95% CI 61.2-95.1), 16% (95% CI 9.4-24.7), 1.0 (95% CI 0.8-1.2) and 1.1 (95% CI 0.4-3) respectively. Regardless of the FBS-to-delivery time the LHR+ for lactate ≥4.2 mmol/L increased to 1.38 (95% CI 1.2-1.6). CONCLUSION: The effectiveness of scalp stimulation test was poor for both ruling in and out fetal hypoxia during labor. Absence of a provoked acceleration seems to be a normal phenomenon in the second stage of labor.


Assuntos
Monitorização Fetal/métodos , Couro Cabeludo/metabolismo , Cardiotocografia , Estudos de Coortes , Dinamarca , Feminino , Sangue Fetal/metabolismo , Hipóxia Fetal/sangue , Hipóxia Fetal/diagnóstico , Humanos , Concentração de Íons de Hidrogênio , Trabalho de Parto , Ácido Láctico/sangue , Estimulação Física , Sistemas Automatizados de Assistência Junto ao Leito , Gravidez , Estudos Retrospectivos
3.
Clin Chim Acta ; 495: 88-93, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30953612

RESUMO

OBJECTIVES: Measurement of lactate in fetal blood is used to assess the degree of anaerobic metabolism. The technical difficulties in obtaining enough scalp blood for analysis by a bloodgas-analyzer advocates for the use of a point-of-care device. StatStrip®Xpress™ (SSX) has shown promising properties but needs further evaluation before implementation into fetal surveillance. METHODS: Arterial/venous umbilical cord blood from 112 newborns were analyzed simultaneously with SSX and the reference method ABL800™. From 321 fetuses with abnormal heart rate scalp blood was sampled and analyzed repeatedly with SSX. RESULTS: ABL800™ -lactate ranged from 1.9-13.3 mmol/L in arterial to 1.5-10.2 mmol/L in venous cord blood with excellent correlation to SSX (R2 = 0.95). SSX-values were lower compared to the reference method ranging from -0.79 mmol/L for low values to -1.68 mmol/L for high values. The mean CV for SSX-values in cord respectively scalp blood was: lactate ≤3 mmol/L 7.1% respectively 8.4%; lactate >3 mmol/L 3.8% respectively 6.8%. Repeated measurements of the same sample with SSX where without significant difference in cord/scalp blood (p = 0.11). CONCLUSION: SSX-lactate values were constantly lower but correlated excellent to the reference method. The reproducibility was good for cord and scalp blood. We suggest SSX as an attractive device for measurement of fetal lactate.


Assuntos
Análise Química do Sangue/métodos , Sangue Fetal/química , Ácido Láctico/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Humanos
4.
Acta Obstet Gynecol Scand ; 90(5): 483-7, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21306343

RESUMO

OBJECTIVE: To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12). DESIGN AND SETTING: Cross-sectional design, University hospital. SAMPLE: Forty-four patients awaiting prolapse surgery. METHODS: The dual-panel translation method followed by an evaluation of validity and reliability in prolapse patients. MAIN OUTCOME MEASURES: Construct, convergent and discriminant validity, reliability via test-retest and internal consistency. RESULTS: Item response rates were high (range 95.5-100%) for PFIQ-7 and PFDI-20. The corrected item-total correlations showed acceptable construct validity for PFIQ-7 (r=0.338-0.826) but low for PFDI-20 (r=0.116-0.581) and PISQ-12 (r=0.024-0.735). Acceptable convergent validity was found in all three instruments, with a negative correlation with the SF-12. There were no floor or ceiling effects in the three instruments. In the test-retest analysis, intraclass correlation coefficients were significant (r=0.888-0.943). Cronbach's α varied between 0.57 and 0.94. CONCLUSION: This is the first validated translation of the PFIQ-7, PFDI-20 and PISQ-12 in Swedish. All three instruments indicated acceptable psychometric properties.


Assuntos
Diafragma da Pelve , Prolapso de Órgão Pélvico , Inquéritos e Questionários/normas , Incontinência Urinária , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Psicometria , Qualidade de Vida , Reprodutibilidade dos Testes , Comportamento Sexual , Suécia , Traduções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA