Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Heart Rhythm ; 20(5): 699-706, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36646235

RESUMO

BACKGROUND: New-onset left bundle branch block (LBBB) is one of the most frequent complications after transcatheter aortic valve implantation (TAVI) and is associated with delayed high degree atrioventricular (AV) block. OBJECTIVES: The objectives of this study were to determine the incidence of AV block in such a population and to assess the performance and safety of a risk stratification algorithm on the basis of electrophysiology study (EPS) followed by implantation of a pacemaker or implantable loop recorder (ILR). METHODS: This was a prospective open-label study with 12-month follow-up. From June 8, 2015, to November 8, 2018, 183 TAVI recipients (mean age 82.3 ± 5.9 years) were included at 10 centers. New-onset LBBB after TAVI persisting for >24 hours was assessed by electrophysiology study during initial hospitalization. High-risk patients (His-ventricle interval ≥70 ms) were implanted with a dual-chamber pacemaker recording AV conduction disturbance episodes. Patients at lower risk were implanted with an ILR with automatic remote monitoring. RESULTS: A high-grade AV conduction disorder was identified in 56 patients (30.6%) at 12 months. Four subjects were symptomatic, all in the ILR group. No complications were associated with the stratification procedure. Patients with His-ventricle interval ≥70 ms displayed more high-grade AV conduction disorders (53.2% [25 of 47] vs 22.8% [31 of 136]; P < .001). In a multivariate analysis, His-ventricle interval ≥70 ms was independently associated with the occurrence of a high-grade conduction disorder (subdistribution hazard ratio 2.4; 95% confidence interval 1.2-4.8; P = .010). CONCLUSION: New-onset LBBB after TAVI was associated with high rates of high-grade AV conduction disturbances. The stratification algorithm provided safe and valuable aid to management decisions and reliable guidance on pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Incidência , Estudos Prospectivos , Eletrocardiografia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
2.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36309156

RESUMO

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Seguimentos , Função Ventricular Direita , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
3.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266008

RESUMO

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Tetralogia de Fallot , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Tetralogia de Fallot/complicações , Estudos de Coortes , Caracteres Sexuais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiopatias Congênitas/complicações
4.
J Cardiovasc Electrophysiol ; 33(5): 1013-1023, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35299286

RESUMO

BACKGROUND: Increasing numbers of patients with cardiac implantable electronic devices (CIEDs) are undergoing radiotherapy (RT) for cancer. The aim of the study was to prospectively evaluate the incidence, characteristics, and associated factors of CIED dysfunctions related to RT. METHODS: Between April 2013 and March 2020, all patients with a CIED who underwent ≥1 RT session were enrolled. Patients were monitored according to a systematic protocol, including device interrogation before the first and after each RT session. The primary endpoint was CIED dysfunction, defined as oversensing, total or partial deprogramming, and/or unrecoverable reset. RESULTS: We included a total of 92 CIED RT courses: 77 (83.7%) in patients with a pacemaker and 15 (16.3%) in those with an implantable cardioverter-defibrillator. Overall, 13 dysfunctions (14.1%) were observed during 92 courses (1509 sessions), giving an incidence of 0.9 per 100 sessions. These included nine deprogramming (three total resets to back-up pacing mode and six partial deprogramming that were all successfully reprogrammed), three transient oversensing, and one unrecoverable oversensing requiring CIED and leads replacement. There were no adverse clinical events related to device dysfunction. In multivariable analysis, neutron-producing irradiation (odds ratio [OR], 5.59; 95% confidence interval [CI], 1.09-28.65; p = .039) and cumulative tumor dose (OR, 1.05; 95% CI, 1.01-1.10; p = .007) remained significantly associated with CIED dysfunction. CONCLUSION: In this prospective study, transient or permanent subclinical CIED dysfunction occurred in 14.1% of RT courses. Our findings emphasize the importance of high-energy beams and neutron-producing irradiation in risk assessment.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Neoplasias , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Cardiopatias/terapia , Humanos , Neoplasias/radioterapia , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos
5.
JACC Clin Electrophysiol ; 7(10): 1285-1293, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33933408

RESUMO

OBJECTIVES: This study aimed to assess the impact of pulmonary valve replacement (PVR) on ventricular arrhythmias burden in a population of tetralogy of Fallot (TOF) patients with continuous cardiac monitoring by implantable cardioverter-defibrillators (ICDs). BACKGROUND: Sudden cardiac death is a major cause of death in TOF, and right ventricular overload is commonly considered to be a potential trigger for ventricular arrhythmias. METHODS: Data were analyzed from a nationwide French ongoing study (DAI-T4F) including all TOF patients with an ICD since 2000. Survival data with recurrent events were used to compare the burden of appropriate ICD therapies before and after PVR in patients who underwent PVR over the study period. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years, 70.1% male) were included from 40 centers. Over a median follow-up period of 6.8 (interquartile range: 2.5 to 11.4) years, 26 patients (15.8%) underwent PVR. Among those patients, 18 (69.2%) experienced at least 1 appropriate ICD therapy. When considering all ICD therapies delivered before (n = 62) and after (n = 16) PVR, the burden of appropriate ICD therapies was significantly lower after PVR (HR: 0.21; 95% confidence interval [CI]: 0.08 to 0.56; p = 0.002). Respective appropriate ICD therapies rates per 100 person-years were 44.0 (95% CI: 35.7 to 52.5) before and 13.2 (95% CI: 7.7 to 20.5) after PVR (p < 0.001). In the overall cohort, PVR before ICD implantation was also independently associated with a lower risk of appropriate ICD therapy in primary prevention patients (HR: 0.29 [95% CI: 0.10 to 0.89]; p = 0.031). CONCLUSIONS: In this cohort of high-risk TOF patients implanted with an ICD, the burden of appropriate ICD therapies was significantly reduced after PVR. While optimal indications and timing for PVR are debated, these findings suggest the importance of considering ventricular arrhythmias in the overall decision-making process. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Valva Pulmonar , Tetralogia de Fallot , Adulto , Arritmias Cardíacas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia
6.
J Cardiovasc Electrophysiol ; 32(5): 1376-1384, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33625762

RESUMO

INTRODUCTION: The evolution of atrioventricular conduction disorders after transcatheter aortic valve implantation (TAVI) remains poorly understood. We sought to identify factors associated with late (occurring ≥7 days after the procedure) high-grade atrioventricular blocks after TAVI, based on specific pacemaker memory data. METHODS AND RESULTS: STIM-TAVI (NCT03338582) was a prospective, multicentre, observational study that enrolled all patients (from November 2015 to January 2017) implanted with a specific dual chamber pacemaker after TAVI, with the SafeR algorithm activated, allowing continuous monitoring of atrioventricular conduction. The primary endpoint was the occurrence of centrally adjudicated late high-grade atrioventricular blocks during the year after TAVI. Among 197 patients, 138 (70.1%) had ≥1 late high-grade atrioventricular block. Whereas oversizing (p = .005), high-grade atrioventricular block during TAVI (p < .001), and early (within 6 days) high-grade atrioventricular block (p < .001) were associated with occurrence of late high-grade atrioventricular block, self-expanding prothesis (p = .88), prior right bundle branch block (p = .45), low implantation (p = .06), and new or wider left bundle branch block and lengthening of PR interval (p = .24) were not. In multivariable analysis, only post-TAVI early high-grade atrioventricular block remained associated with late high-grade atrioventricular blocks (Days 0-1: odds ratio [OR], 3.25; 95% confidence interval [CI], 1.57-6.74; p = .001; Days 2-6: OR, 4.13; 95% CI, 2.06-8.31; p < .001), whereas other conventionally used predictors were not. CONCLUSION: One-third of pacemaker-implanted patients do not experience late high-grade atrioventricular block. Our findings suggest that post-TAVI early high-grade atrioventricular block is the main factor associated with occurrence of late high-grade atrioventricular blocks.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
8.
Eur Heart J Case Rep ; 4(2): 1-7, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32352047

RESUMO

BACKGROUND: Pocket complications are common after cardiac implantable electronic device implantation. We report a rare case of pyoderma gangrenosum (PG) complicating a permanent pacemaker implantation, and the first literature review of 10 published cases. CASE SUMMARY: Five days after pacemaker implantation for heart failure and 2:1 atrioventricular block, a 93-year-old man had pain in the scar and bleeding on contact. Two days later, he had fever, inflammatory syndrome, and a necrotic 7-cm wound. The pacemaker was removed and he was started on antibiotics. Due to a lack of bacterial growth in samples, PG (a rare aseptic, destructive inflammatory cutaneous condition) was suspected, and histology was compatible with this diagnosis. High-dose corticosteroids vastly improved his condition within 1 week, and after 2 months of decreasing-dose corticosteroid therapy, complete healing and normalization of the inflammatory syndrome were observed. DISCUSSION: Pyoderma gangrenosum should be considered if there is aseptic skin ulceration that is not controlled by antibiotic treatment. The first-line treatment for PG is high-dose systemic corticosteroids.

9.
BMJ Open ; 6(10): e010485, 2016 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-27797979

RESUMO

INTRODUCTION: Percutaneous aortic valve replacement (transcatheter aortic valve implantation (TAVI)) notably increases the likelihood of the appearance of a complete left bundle branch block (LBBB) by direct lesion of the LBB of His. This block can lead to high-grade atrioventricular conduction disturbances responsible for a poorer prognosis. The management of this complication remains controversial. METHOD AND ANALYSIS: The screening of LBBB after TAVI persisting for more than 24 hours will be conducted by surface ECG. Stratification will be performed by post-TAVI intracardiac electrophysiological study. Patients at high risk of conduction disturbances (≥70 ms His-ventricle interval (HV) or presence of infra-Hisian block) will be implanted with a pacemaker enabling the recording of disturbance episodes. Those at lower risk (HV <70 ms) will be implanted with a loop recorder device with remote monitoring of cardiovascular implantable electronic devices (CIEDs). Clinical, ECG and implanted device follow-up will also be performed at 3, 6 and 12 months. The primary objective is to assess the efficacy and safety of a decisional algorithm based on electrophysiological study and remote monitoring of CIEDs in the prediction of high-grade conduction disturbances in patients with LBBB after TAVI. The primary end point is to compare the incidence (rate and time to onset) of high-grade conduction disturbances in patients with LBBB after TAVI between the two groups at 12 months. Given the proportion of high-grade conduction disturbances (20-40%), a sample of 200 subjects will allow a margin of error of 6-7%. The LBBB-TAVI Study has been in an active recruiting phase since September 2015 (21 patients already included). ETHICS AND DISSEMINATION: Local ethics committee authorisation was obtained in May 2015. We will publish findings from this study in a peer-reviewed scientific journal and present results at national and international conferences. TRIAL REGISTRATION NUMBER: NCT02482844; Pre-results.


Assuntos
Algoritmos , Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Tomada de Decisão Clínica/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/diagnóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Adulto , Valva Aórtica/patologia , Bloqueio de Ramo/etiologia , Cateterismo Cardíaco/efeitos adversos , Doença do Sistema de Condução Cardíaco , Eletrocardiografia , Fenômenos Eletrofisiológicos , Coração/fisiopatologia , Humanos , Monitorização Fisiológica , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Prognóstico , Projetos de Pesquisa , Resultado do Tratamento
10.
Arch Cardiovasc Dis ; 108(3): 189-96, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25669959

RESUMO

BACKGROUND: Many studies have suggested that longer duration of cardiac monitoring is suitable for the detection of occult paroxysmal atrial fibrillation (AF) after stroke; however, most studies involved patients aged≥65years - a population with a high stroke rate. AIMS: To assess the incidence of paroxysmal AF in unselected young patients presenting with stroke. METHODS: We included consecutive patients aged<60years with a stroke diagnosis on magnetic resonance imaging. Aetiological screening included clinical history and examination, and biological and cardiac tests. Patients were included if they had no history of AF and if a 24-hour electrocardiogram recording detected no AF or atrial flutter. Patients wore the SpiderFlash(®) monitor for 21days after discharge from hospital. The primary outcome was detection of paroxysmal AF episodes lasting>30seconds during monitoring. The secondary outcome was detection of paroxysmal AF episodes lasting<30seconds and any arrhythmia during monitoring. RESULTS: Among the 56 patients included (mean age 48±9years), 39 had cryptogenic stroke (CS) and 17 had stroke of known cause (SKC). Cardiac monitoring was achieved in 54 patients (37 CS, 17 SKC); one CS patient had a paroxysmal AF episode lasting>30seconds and one CS patient had a paroxysmal AF episode lasting<30seconds (versus no patients in the SKC group). Two CS patients and one SKC patient presented numerous premature atrial complexes. Non-sustained ventricular tachycardia was detected in one CS patient. CONCLUSION: This prospective observational study showed a low rate of paroxysmal AF among young patients presenting with stroke, on the basis of 21-day cardiac monitoring. This result highlights the need to identify patients who would benefit from such long monitoring.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial , Adulto , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Isquemia Encefálica/complicações , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/complicações , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA