Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(6): e14330, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38478368

RESUMO

BACKGROUND: This study aimed to evaluate the clinical acceptability of rotational gantry-based single-position carbon-ion radiotherapy (CIRT) to reduce the gastrointestinal (GI) dose in pancreatic cancer. We also evaluated the usefulness of the deformable image registration (DIR)-based dosimetry method for CIRT. MATERIAL AND METHODS: Fifteen patients with pancreatic cancer were analyzed. The treatment plans were developed for four beam angles in the supine (SP plan) and prone (PR plan) positions. In the case of using multiple positions, the treatment plan was created with two angles for each of the supine and prone position (SP + PR plan). Dose evaluation for multiple positions was performed in two ways: by directly adding the values of the DVH parameters for each position treatment plan (DVH sum), and by calculating the DVH parameters from the accumulative dose distribution created using DIR (DIR sum). The D2cc and D6cc of the stomach and duodenum were recorded for each treatment plan and dosimetry method and compared. RESULTS: There were no significant differences among any of the treatment planning and dosimetry methods (p > 0.05). The DVH parameters for the stomach and duodenum were higher in the PR plan and SP plan, respectively, and DVH sum tended to be between the SP and PR plans. DVH sum and DIR sum, DVH sum tended to be higher for D2cc and DIR sum tended to be higher for D6cc. CONCLUSION: There were no significant differences in the GI dose, which suggests that treatment with a simple workflow performed in one position should be clinically acceptable. In CIRT, DIR-based dosimetry should be carefully considered because of the potential for increased uncertainty due to the steep dose distributions.


Assuntos
Radioterapia com Íons Pesados , Órgãos em Risco , Neoplasias Pancreáticas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia com Íons Pesados/métodos , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/métodos , Posicionamento do Paciente , Masculino , Feminino , Processamento de Imagem Assistida por Computador/métodos , Idoso , Pessoa de Meia-Idade , Prognóstico
2.
J Appl Clin Med Phys ; 25(1): e14217, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018758

RESUMO

PURPOSE: Chest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error. MATERIAL AND METHODS: This study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan. RESULT: No significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP. CONCLUSION: We revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Parede Torácica , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Mastectomia
3.
J Appl Clin Med Phys ; 24(12): e14122, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37559561

RESUMO

The Unity magnetic resonance (MR) linear accelerator (MRL) with MR-guided adaptive radiotherapy (MRgART) is capable of online MRgART where images are acquired on the treatment day and the radiation treatment plan is immediately replanned and performed. We evaluated the MRgART plan quality and plan reproducibility of the Unity MRL in patients with prostate cancer. There were five low- or moderate-risk and five high-risk patients who received 36.25 Gy or 40 Gy, respectively in five fractions. All patients underwent simulation magnetic resonance imaging (MRI) and five online adaptive MRI. We created plans for 5, 7, 9, 16, and 20 beams and for 60, 100, and 150 segments. We evaluated the target and organ doses for different number of beams and segments, respectively. Variation in dose constraint between the simulation plan and online adaptive plan was measured for each patient to assess plan reproducibility. The plan quality improved with the increasing number of beams. However, the proportion of significantly improved dose constraints decreased as the number of beams increased. For some dose parameters, there were statistically significant differences between 60 and 100 segments, and 100 and 150 segments. The plan of five beams exhibited limited reproducibility. The number of segments had minimal impact on plan reproducibility, but 60 segments sometimes failed to meet dose constraints for online adaptive plan. The optimization and delivery time increased with the number of beams and segments. We do not recommend using five or fewer beams for a reproducible and high-quality plan in the Unity MRL. In addition, many number of segments and beams may help meet dose constraints during online adaptive plan. Treatment with the Unity MRL should be performed with the appropriate number of beams and segments to achieve a good balance among plan quality, delivery time, and optimization time.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Masculino , Humanos , Reprodutibilidade dos Testes , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
4.
J Radiat Res ; 64(5): 783-794, 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37466450

RESUMO

In external radiotherapy of head and neck (HN) cancers, the reduction of irradiation accuracy due to HN volume reduction often causes a problem. Adaptive radiotherapy (ART) can effectively solve this problem; however, its application to all cases is impractical because of cost and time. Therefore, finding priority cases is essential. This study aimed to predict patients with HN cancers are more likely to need ART based on a quantitative measure of large HN volume reduction and evaluate model accuracy. The study included 172 cases of patients with HN cancer who received external irradiation. The HN volume was calculated using cone-beam computed tomography (CT) for irradiation-guided radiotherapy for all treatment fractions and classified into two groups: cases with a large reduction in the HN volume and cases without a large reduction. Radiomic features were extracted from the primary gross tumor volume (GTV) and nodal GTV of the planning CT. To develop the prediction model, four feature selection methods and two machine-learning algorithms were tested. Predictive performance was evaluated by the area under the curve (AUC), accuracy, sensitivity and specificity. Predictive performance was the highest for the random forest, with an AUC of 0.662. Furthermore, its accuracy, sensitivity and specificity were 0.692, 0.700 and 0.813, respectively. Selected features included radiomic features of the primary GTV, human papillomavirus in oropharyngeal cancer and the implementation of chemotherapy; thus, these features might be related to HN volume change. Our model suggested the potential to predict ART requirements based on HN volume reduction .


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Humanos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Pescoço , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico , Estudos Retrospectivos
5.
Sci Rep ; 12(1): 8899, 2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35624113

RESUMO

Early regression-the regression in tumor volume during the initial phase of radiotherapy (approximately 2 weeks after treatment initiation)-is a common occurrence during radiotherapy. This rapid radiation-induced tumor regression may alter target coordinates, necessitating adaptive radiotherapy (ART). We developed a deep learning-based radiomics (DLR) approach to predict early head and neck tumor regression and thereby facilitate ART. Primary gross tumor volume (GTVp) was monitored in 96 patients and nodal GTV (GTVn) in 79 patients during treatment. All patients underwent two computed tomography (CT) scans: one before the start of radiotherapy for initial planning and one during radiotherapy for boost planning. Patients were assigned to regression and nonregression groups according to their median tumor regression rate (ΔGTV/treatment day from initial to boost CT scan). We input a GTV image into the convolutional neural network model, which was pretrained using natural image datasets, via transfer learning. The deep features were extracted from the last fully connected layer. To clarify the prognostic power of the deep features, machine learning models were trained. The models then predicted the regression and nonregression of GTVp and GTVn and evaluated the predictive performance by 0.632 + bootstrap area under the curve (AUC). Predictive performance for GTVp regression was highest using the InceptionResNetv2 model (mean AUC = 0.75) and that for GTVn was highest using NASNetLarge (mean AUC = 0.73). Both models outperformed the handcrafted radiomics features (mean AUC = 0.63 for GTVp and 0.61 for GTVn) or clinical factors (0.64 and 0.67, respectively). DLR may facilitate ART for improved radiation side-effects and target coverage.


Assuntos
Aprendizado Profundo , Neoplasias de Cabeça e Pescoço , Lesões por Radiação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS