Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Hypertens ; 40(6): 1199-1203, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35703882

RESUMO

BACKGROUND: In hypertension, ß-blockers have a high rate of nonadherence to treatment likely because of fatigue. METHODS: We evaluate daily physical activity and maximal exercise performance in 56 patients with hypertension (grades I-II), with and without ß-blockers (bisoprolol 10 mg or atenolol 100 mg) added to standard treatment; 48 patients completed the study. Study tests were performed after 8 weeks of antihypertensive therapy without ß blockers and after the following 8 weeks with ß-blockers. RESULTS: No significant differences between ß-blockers were observed. At office measurement, ß-blockers decreased heart rate (HR) from 78 ±â€Š9 to 62 ±â€Š7 bpm (P < 0.01) and SBP from 133 ±â€Š13 to 125 ±â€Š12 mmHg (P < 0.01). No significant changes were observed for DBP. Conversely, at ambulatory pressure monitoring DBP but not SBP decreased with ß-blockers (mean-24-h DBP 77 ±â€Š8 vs. 74 ±â€Š7 mmHg, P < 0.01). An overall reduction of daily activities and of estimated kilocalories consumption was observed as measured by a portable armband device. Of note, time with activity more than 3 METS was reduced by ß-blockers from 148.1 (83-201) to 117.9 (82-189) min (P < 0.01). Cardiopulmonary exercise (CPE) showed a preserved exercise performance unaffected by ß-blockers. CONCLUSION: In hypertension, ß-blocker treatment is associated to reduction of daily physical activity but not of maximal exercise performance.


Assuntos
Antagonistas Adrenérgicos beta , Hipertensão , Antagonistas Adrenérgicos beta/farmacologia , Anti-Hipertensivos/farmacologia , Pressão Sanguínea , Exercício Físico , Frequência Cardíaca , Humanos , Hipertensão/tratamento farmacológico
2.
J Clin Med ; 11(3)2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35159929

RESUMO

Coronary artery disease (CAD) represents the most common cardiovascular disease, with high morbidity and mortality. Historically patients with chest pain of suspected coronary origin have been assessed with functional tests, capable to detect haemodynamic consequences of coronary obstructions through depiction of electrocardiographic changes, myocardial perfusion defects or regional wall motion abnormalities under stress condition. Stress echocardiography (SE), single-photon emission computed tomography (SPECT), positron emission tomography (PET) and cardiovascular magnetic resonance (CMR) represent the functional techniques currently available, and technical developments contributed to increased diagnostic performance of these techniques. More recently, cardiac computed tomography angiography (cCTA) has been developed as a non-invasive anatomical test for a direct visualisation of coronary vessels and detailed description of atherosclerotic burden. Cardiovascular imaging techniques have dramatically enhanced our knowledge regarding physiological aspects and myocardial implications of CAD. Recently, after the publication of important trials, international guidelines recognised these changes, updating indications and level of recommendations. This review aims to summarise current standards with main novelties and specific limitations, and a diagnostic algorithm for up-to-date clinical management is also proposed.

3.
J Clin Med ; 10(21)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34768549

RESUMO

We aimed to evaluate the feasibility and accuracy of machine learning-based automated dynamic quantification of left ventricular (LV) and left atrial (LA) volumes in an unselected population. We enrolled 600 unselected patients (12% in atrial fibrillation) clinically referred for transthoracic echocardiography (2DTTE), who also underwent 3D echocardiography (3DE) imaging. LV ejection fraction (EF), LV, and LA volumes were obtained from 2D images; 3D images were analyzed using dynamic heart model (DHM) software (Philips) resulting in LV and LA volume-time curves. A subgroup of 140 patients also underwent cardiac magnetic resonance (CMR) imaging. Average time of analysis, feasibility, and image quality were recorded, and results were compared between 2DTTE, DHM, and CMR. The use of DHM was feasible in 522/600 cases (87%). When feasible, the boundary position was considered accurate in 335/522 patients (64%), while major (n = 38) or minor (n = 149) border corrections were needed. The overall time required for DHM datasets was approximately 40 seconds. As expected, DHM LV volumes were larger than 2D ones (end-diastolic volume: 173 ± 64 vs. 142 ± 58 mL, respectively), while no differences were found for LV EF and LA volumes (EF: 55% ± 12 vs. 56% ± 14; LA volume 89 ± 36 vs. 89 ± 38 mL, respectively). The comparison between DHM and CMR values showed a high correlation for LV volumes (r = 0.70 and r = 0.82, p < 0.001 for end-diastolic and end-systolic volume, respectively) and an excellent correlation for EF (r = 0.82, p < 0.001) and LA volumes. The DHM software is feasible, accurate, and quick in a large series of unselected patients, including those with suboptimal 2D images or in atrial fibrillation.

4.
J Cardiovasc Dev Dis ; 8(7)2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34202460

RESUMO

MitraClip (MC) is the most common percutaneous treatment for severe mitral regurgitation (MR). An accurate two-dimensional and three-dimensional echocardiographic (3DTEE) imaging is mandatory for the optimal procedural result. Recently transillumination 3DTEE rendering (3DTr) has been introduced integrating a virtual light source into the dataset and with the addition of glass effect (3DGl) allows to adjust tissue transparency improving depth perception and anatomical structure delineation in comparison with the standard 3DTEE (3DSt). The aim of this retrospective study in 30 patients undergoing MC, was to compare 3DSt, 3DTr, and 3DGl in mitral valve (MV) evaluation and procedural result assessment. 3DTEE acquisitions obtained before and after MC were processed with 3DSt, 3DTr, and 3DGl rendering. Each reconstruction was scored for quality and for ability to recognize MV anatomy, MR origin, clip position, dimension and grasping. Imaging quality was judged good or optimal in 52%, 76%, and 96% in 3DSt, 3DTr, and 3DGl reconstructions respectively. In 26/30 patients a diagnostic incremental value was found with 3DTr vs. 3DSt and in 15/26 with 3DGl vs. 3DTr and 3DSt. Only 3DGl with perpendicular cropping of the clip allowed to visualize and measure the grasped portion of each mitral leaflets. 3DTEE imaging during MC may be improved by 3DTr and 3DGl providing a better evaluation of MV, of leaflet grasping and of residual MR jets after MC.

5.
J Clin Med ; 10(3)2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33494387

RESUMO

Cardiovascular imaging is developing at a rapid pace and the newer modalities, in particular three-dimensional echocardiography, allow better analysis of heart structures. Identifying valve lesions and grading their severity represents crucial information and nowadays is strengthened by the introduction of new software, such as transillumination, which provide detailed morphology descriptions. Chambers quantification has never been so rapid and accurate: machine learning algorithms generate automated volume measurements, including left ventricular systolic and diastolic function, which is extremely important for clinical decisions. This review provides an overview of the latest innovations in the echocardiography field, and is helpful by providing a better insight into heart diseases.

7.
Heart ; 107(1): 25-32, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32723759

RESUMO

OBJECTIVE: Mitral annular disjunction (MAD) is an abnormality linked to mitral valve prolapse (MVP), possibly associated with malignant ventricular arrhythmias. We assessed the agreement among different imaging techniques for MAD identification and measurement. METHODS: 131 patients with MVP and significant mitral regurgitation undergoing transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) were retrospectively enrolled. Transoesophageal echocardiography (TOE) was available in 106 patients. MAD was evaluated in standard long-axis views (four-chamber, two-chamber, three-chamber) by each technique. RESULTS: Considering any-length MAD, MAD prevalence was 17.3%, 25.5%, 42.0% by TTE, TOE and CMR, respectively (p<0.05). The agreement on MAD identification was moderate between TTE and CMR (κ=0.54, 95% CI 0.49 to 0.59) and good between TOE and CMR (κ=0.79, 95% CI 0.74 to 0.84). Assuming CMR as reference and according to different cut-off values for MAD (≥2 mm, ≥4 mm, ≥6 mm), specificity (95% CI) of TTE and TOE was 99.6 (99.0 to 100.0)% and 98.7 (97.4 to 100.0)%; 99.3 (98.4 to 100.0)% and 97.6 (95.8 to 99.4)%; 97.8 (96.2 to 99.3)% and 93.2 (90.3 to 96.1)%, respectively; sensitivity (95% CI) was 43.1 (37.8 to 48.4)% and 74.5 (69.4 to 79.5)%; 54.0 (48.7 to 59.3)% and 88.9 (85.2 to 92.5)%; 88.0 (84.5 to 91.5)% and 100.0 (100.0 to 100.0)%, respectively. MAD length was 8.0 (7.0-10.0), 7.0 (5.0-8.0], 5.0 (4.0-7.0) mm, respectively by TTE, TOE and CMR. Agreement on MAD measurement was moderate between TTE and CMR (ρ=0.73) and strong between TOE and CMR (ρ=0.86). CONCLUSIONS: An integrated imaging approach could be necessary for a comprehensive assessment of patients with MVP and symptoms suggestive for arrhythmias. If echocardiography is fundamental for the anatomic and haemodynamic characterisation of the MV disease, CMR may better identify small length MAD as well as myocardial fibrosis.


Assuntos
Técnicas de Imagem Cardíaca , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Ecocardiografia , Ecocardiografia Transesofagiana , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/patologia , Prolapso da Valva Mitral/patologia , Imagem Multimodal , Estudos Retrospectivos
9.
Diagnostics (Basel) ; 10(12)2020 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-33348561

RESUMO

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) requires accurate pre- and intraprocedural measurements, and multimodality imaging is an essential tool for guiding the procedure. Two-dimensional (2D TOE) and three-dimensional (3D TOE) transoesophageal echocardiography, cardiac computed tomography (CCT), and conventional cardiac angiography (CCA) are commonly used to evaluate left atrial appendage (LAA) size. However, standardized approaches in measurement methods by different imaging modalities are lacking. The aims of the study were to evaluate the LAA dimension and morphology in patients undergoing LAAC and to compare data obtained by different imaging modalities: 2D and 3D TOE, CCT, and CCA. METHODS: A total of 200 patients (mean age 70 ± 8 years, 128 males) were examined by different imaging techniques (161 2D TOE, 103 3D TOE, 98 CCT, and 200 CCA). Patients underwent preoperative CCT and intraoperative 2D and 3D TOE and CCA. RESULTS: A significant correlation was found among all measurements obtained by different modalities. In particular, 3D TOE and CCT measurements were highly correlated with an excellent agreement for the landing zone (LZ) dimensions (LZ diameter: r = 0.87; LAA depth: r = 0.91, p < 0.001). CONCLUSIONS: Head-to-head comparison among imaging techniques (2D and 3D TOE, CCT, and CCA) showed a good correlation among LZ diameter measurements obtained by different imaging modalities, which is a parameter of paramount importance for the choice of the LAAC device size. LZ diameters and area by 3D TOE had the best correlation with CCT.

10.
J Cardiovasc Dev Dis ; 7(4)2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33092178

RESUMO

The "ideal" management of asymptomatic severe mitral regurgitation (MR) in valve prolapse (MVP) is still debated. The aims of this study were to identify pre-operatory parameters predictive of residual MR and of early and long-term favorable remodeling after MVP repair. We included 295 patients who underwent MV repair for MVP with pre-operatory two- and three-dimensional transthoracic echocardiography (2DTTE and 3DTTE) and 6-months (6M) and 3-years (3Y) follow-up 2DTTE. MVP was classified by 3DTTE as simple or complex and surgical procedures as simple or complex. Pre-operative echo parameters were compared to post-operative values at 6M and 3Y. Patients were divided into Group 1 (6M-MR < 2) and Group 2 (6M-MR ≥ 2), and predictors of MR 2 were investigated. MVP was simple in 178/295 pts, and 94% underwent simple procedures, while in only 42/117 (36%) of complex MVP a simple procedure was performed. A significant relation among prolapse anatomy, surgical procedures and residual MR was found. Post-operative MR ≥ 2 was present in 9.8%: complex MVP undergoing complex procedures had twice the percentage of MR ≥ 2 vs. simple MVP and simple procedures. MVP complexity resulted independent predictor of 6M-MR ≥ 2. Favorable cardiac remodeling, initially found in all cases, was maintained only in MR < 2 at 3Y. Pre-operative 3DTTE MVP morphology identifies pts undergoing simple or complex procedures predicting MR recurrence and favorable cardiac remodeling.

12.
Heart Rhythm ; 16(9): 1320-1326, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30928784

RESUMO

BACKGROUND: The combined left atrial appendage closure (LAAC) and cryoenergy pulmonary vein isolation (PVI) procedure has been proven safe and effective in managing stroke in patients with nonvalvular atrial fibrillation (AF), although most data refer to procedures performed using radiofrequency as the main energy source. OBJECTIVE: The purpose of this study was to evaluate long-term follow-up of patients with AF undergoing concomitant LAAC and cryoenergy PVI. METHODS: Patients undergoing LAAC and cryoballoon PVI at our institution were enrolled. At 3, 6, and 24 months from the index procedure, we determined the atrial arrhythmia recurrence rate, the extent of LAAC, and the rate of cerebrovascular/bleeding events. RESULTS: Forty-nine patients (mean age 69 ± 8 years; 32/49 (67%) men; CHA2DS2-VASc score 2.8 ± 1.2; HAS-BLED score 3 ± 1) with a guideline-recommended LAAC indication were included. Acute PVI and complete LAAC were achieved in 100% of patients. All patients completed at least 24 months of follow-up. At 8 weeks and 6 months, complete or satisfactory (<5 mm leak) LAAC rates were achieved in 40 (82%) and 9 (18%) and in 42 (86%) and 7 (14%) of patients, respectively. The overall freedom from atrial arrhythmia rate at 24 months was 29 (60%), and 45 (92%) of patients were off antithrombotic drugs. The observed annualized stroke and bleeding rates were 1% and 2%, respectively, a 71% and 60% risk reduction in comparison to event rates predicted from CHA2DS2-VASc and HAS-BLED scores. CONCLUSION: Concomitant cryoballoon ablation and LAAC procedures appear safe and effective at long-term follow-up, with high antithrombotic drug withdrawal rates at 24 months.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Criocirurgia , Hemorragia , Efeitos Adversos de Longa Duração/epidemiologia , Acidente Vascular Cerebral , Idoso , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Veias Pulmonares/cirurgia , Recidiva , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
13.
J Cardiovasc Comput Tomogr ; 13(6): 336-339, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30389341

RESUMO

BACKGROUND: We sought to evaluate the additional value of left atrial appendage (LAA) 3D printing derived from computed tomography (CCT) in determining the size for LAA occlusion (LAAO) devices as compared to standard measurement by using occurrence of LAA leak as endpoint. METHODS: We evaluated 6 patients with LAA leak (cases) and 14 matched patients without LAA leak (controls) after LAAO. For each group, a patient-specific 3D printed model of LAA was manufactured using CT pre-operative images. The size recommended by the 3D printed model was compared with the size of the implanted device. RESULTS: Compared to the 3D printed model, 55% of the devices were underestimated, the two sizing approaches agreed in 35% of the patients, while the 3D printed model overestimated the size in 10% of patients. The prevalence of LAA leak was significantly higher in the subset of patients with underestimation of prosthesis implanted with the standard approach as compared to the other patients (p = 0.019). CONCLUSION: 3D printing of the LAA may provide additional value to standard practice for LAAO device prosthesis sizing with the potential impact to reduce LAA leak.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Modelos Anatômicos , Modelos Cardiovasculares , Impressão Tridimensional , Desenho de Prótese , Implantação de Prótese/instrumentação , Tomografia Computadorizada por Raios X , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
14.
Eur J Prev Cardiol ; 22(2): 206-12, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24165475

RESUMO

BACKGROUND: In heart failure, lung diffusion is reduced, it correlates with prognosis and exercise capacity, and it is a therapy target. DESIGN: Diffusion is measured as CO total diffusion (DL(CO)), which has two components: membrane diffusion (Dm) and capillary volume, the latter related to CO and O2 competition for hemoglobin. DL(CO) needs to be corrected for hemoglobin. Diffusion can also be measured with NO (DL(NO)), which has a very high affinity for hemoglobin, and thus, the resistance of hemoglobin being trivial, it directly represents Dm. Therefore, Dm is directly calculated from DL(NO) through a correction factor. DL(NO) has never been measured in heart failure. The study aims at determining, in heart failure, DL(NO), Dm correction factor, and whether Dm(NO) provides Dm estimates comparable to Dm(CO). METHODS: We measured DL(CO), Dm(CO) by multi-maneuver Roughton-Forster method, and DL(CO) and DL(NO) by single-breath maneuver in 50 heart failure and 50 healthy subjects. RESULTS: DL(CO) was 21.9 ± 4.8 ml/mmHg per min and 16.8 ± 5.1 in healthy subjects and heart failure subjects, respectively (p < 0.001). DL(NO) was 88.6 ± 20.5 ml/mmHg per min and 72.5 ± 22.3, respectively (p < 0.001). The correction factors to obtain Dm from DL(NO) were 2.68 (entire population), 2.63 (healthy subjects) and 2.75 (heart failure subjects). Dm(CO) and Dm(NO) were 34.7 ± 10.9 ml/mmHg per min and 33.8 ± 7.6 in healthy subjects and 25.9 ± 2.0 and 26.4 ± 8.1 in heart failure subjects. CONCLUSIONS: DL(NO) and Dm(NO) measurements are feasible in heart failure. Dm(CO) and Dm(NO) provide comparable results. The correction factor to calculate Dm from DL(NO) in heart failure is 2.75, which is little different from the 2.63 value we observed in healthy subjects.


Assuntos
Broncodilatadores , Insuficiência Cardíaca/fisiopatologia , Óxido Nítrico , Alvéolos Pulmonares/fisiologia , Capacidade de Difusão Pulmonar/fisiologia , Idoso , Capilares/fisiologia , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Troca Gasosa Pulmonar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA