Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
2.
BMC Womens Health ; 23(1): 397, 2023 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-37516869

RESUMO

BACKGROUND: Endometrial scratching (ES) or injury is intentional damage to the endometrium performed to improve reproductive outcomes for infertile women desiring pregnancy. Moreover, recent systematic reviews with meta-analyses and randomized controlled trials demonstrated that ES is not effective, data on the safety are limited, and it should not be recommended in clinical practice. The aim of the current study was to assess the view and behavior towards ES among fertility specialists throughout infertility centers in Italy, and the relationship between these views and the attitudes towards the use of ES as an add-on in their commercial setting. METHODS: Online survey among infertility centers, affiliated to Italian Society of Human Reproduction (SIRU), was performed using a detailed questionnaire including 45 questions with the possibility to give "closed" multi-choice answers for 41 items and "open" answers for 4 items. Online data from the websites of the infertility centers resulting in affiliation with the specialists were also recorded and analyzed. The quality of information about ES given on infertility centers websites was assessed using a scoring matrix including 10 specific questions (scored from 0 to 2 points), and the possible scores ranged from 0 to 13 points ('excellent' if the score was 9 points or more, 'moderate' if the score was between 5 and 8, and 'poor' if it was 4 points or less). RESULTS: The response rate was of 60.6% (43 questionnaires / 71 infertility SIRU-affiliated centers). All included questionnaires were completed in their entirety. Most physicians (~ 70%) reported to offer ES to less than 10% of their patients. The procedure is mainly performed in the secretory phase (69.2%) using pipelle (61.5%), and usually in medical ambulatory (56.4%) before IVF cycles to improve implantation (71.8%) without drugs administration (e.g., pain drugs, antibiotics, anti-hemorrhagics, or others) before (76.8%) or after (64.1%) the procedure. Only a little proportion of infertility centers included in the analysis proposes formally the ES as an add-on procedure (9.3%), even if, when proposed, the full description of the indications, efficacy, safety, and costs is never addressed. However, the overall information quality of the websites was generally "poor" ranging from 3 to 8 and having a low total score (4.7 ± 1.6; mean ± standard deviation). CONCLUSIONS: In Italy, ES is a procedure still performed among fertility specialists for improving the implantation rate in IVF patients. Moreover, they have a poor attitude in proposing ES as an add-on in the commercial setting.


Assuntos
Infertilidade Feminina , Feminino , Gravidez , Humanos , Infertilidade Feminina/terapia , Fertilidade , Itália , Endométrio , Atitude
3.
Metabolites ; 13(3)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36984881

RESUMO

Breast cancer (BC) is the most common type of cancer among women in almost all countries worldwide and is one of the oncological pathologies for which is indicated fertility preservation, a type of procedure used to help keep a person's ability to have children. Follicular fluid (FF) is a major component of oocyte microenvironment, which is involved in oocyte growth, follicular maturation, and in communication between germ and somatic cells; furthermore, it accumulates all metabolites during oocytes growth. To obtain information about changes on fertility due to cancer, we aimed at investigating potential biomarkers to discriminate between FF samples obtained from 16 BC patients and 10 healthy women undergoing in vitro fertilization treatments. An NMR-based metabolomics approach was performed to investigate the FF metabolic profiles; ELISA and western blotting assays were used to investigate protein markers of oxidative and inflammatory stress, which are processes closely related to cancer. Our results seem to suggest that FFs of BC women display some significant metabolic alterations in comparison to healthy controls, and these variations are also related with tumor staging.

4.
Front Physiol ; 13: 840109, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35283772

RESUMO

The aim of this pilot study is to evaluate if SARS-CoV-2 infection or vaccination against SARS-CoV-2 infection induce observable metabolic effects in follicular fluid of women who are following in vitro fertilization (IVF) treatments. The possible impact of coronavirus disease 2019 (COVID-19) on fertility and IVF outcome is considered. We have selected for this study: six women vaccinated against SARS-CoV-2 infection, five recovered COVID-19 patients, and we used nine healthy women as the control group. At the time of oocytes retrieval from participants in the study, follicular fluids were collected and metabolomic analysis was performed by 1H NMR spectroscopy in combination with multivariate analysis to interpret the spectral data. The search for antibody positivity in the follicular fluid aspirates was also carried out, together with the western blotting analysis of some inflammatory proteins, interleukin-6, tumor necrosis factor α (TNFα), and the free radical scavenger superoxide dismutase 2. Higher levels of Ala and Pro together with lower levels of lipids and trimethylamine N-oxide (TMAO) were found in follicular fluids (FFs) of vaccinated women while lower levels of many metabolites were detected in FFs of recovered COVID patients. Expression level of TNF-α was significantly lower both in recovered COVID-19 patients and vaccinated women in comparison to healthy controls.

5.
J Interv Card Electrophysiol ; 64(3): 641-648, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34853986

RESUMO

PURPOSE: A new cryoballoon (CB) technology (POLARx™; Boston Scientific) for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF) has recently been introduced. The aim of this study was to evaluate procedural and biophysical parameters resulting in acute PV isolation when using this new CB. METHODS: We assessed the first 69 consecutive patients indicated for AF ablation who underwent PV isolation by means of a novel CB system. Procedural metrics were prospectively recorded. RESULTS: A total of 274 PVs were targeted in 69 patients. PV isolation was achieved in all patients by means of cryoablation alone. The median time to isolation (TTI) was 44 [31-68] s (median temperature at TTI = - 49 [- 53 to - 41] °C). The median duration of CB ablation was 180 [180 to 240] s. The median nadir temperature was - 56.0 [- 61 to - 52] °C, and the median thaw time to 0 °C was 18 [15-21] s. The median grade of PV occlusion was 4 [3 to 4]. On the basis of ROC analysis, we defined the following cut-off values for acute PV isolation: - 56 °C for nadir temperature (sensitivity = 73.3%, specificity = 64.6%, AUC = 0.716; positive predictive value = 88.1%), 30 s for TTT (60.2%, 53.3%, 0.578; 79.7%), thaw time > 17 s (65.3%, 70.0%, 0.709; 86.9%), and grade of PV occlusion = 4 (79.4%, 66.7%, 0.738; 88.5%). No major procedure-related adverse events were observed at 30-day post-procedure. CONCLUSIONS: The new POLARx™ CB appears to be effective and safe. A nadir temperature of - 56 °C, a thaw time to 0 °C ≥ 17 s, and complete PV occlusion were the best predictors of acute PV isolation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/Identifier : NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Sistema de Registros , Resultado do Tratamento
6.
Arch Gynecol Obstet ; 302(3): 741-751, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32462220

RESUMO

INTRODUCTION: The main goal of this retrospective cohort study is the assessment of the effects of administration of recombinant-hCG (r-hCG) versus urinary-hCG (u-hCG) on follicular fluid (FF) composition of women who underwent in vitro fertilization (IVF) treatments. MATERIALS AND METHODS: We selected 70 patients with infertility attributable to tubal diseases, unexplained infertility, and male factor. Metabolomics analysis of their FFs was performed by 1H nuclear magnetic resonance (1H NMR) spectroscopy in combination with multivariate analysis to interpret the spectral data. Univariate statistical analysis was applied to investigate the possible correlations between clinical parameters and between clinical parameters and metabolites identified by NMR. RESULTS: According to the type of hCG used, significant differences were detected in FFs of women with male factor and unexplained infertility, both in qualitative and quantitative terms, for some metabolites as cholesterol, citrate, creatine, ß-hydroxybutyrate, glycerol, lipids, amino acids (Glu, Gln, His, Val, Lys) and glucose. No significant difference was observed in women with tubal diseases. Besides, the number of MII oocytes in the u-hCG-treated groups correlates positively with glutamate in tubal disease and with glycerol in unexplained infertility. In the r-hCG-treated groups, the number of MII oocytes correlates positively with lipid in tubal disease, positively with citrate and negatively with glucose in male infertility. CONCLUSIONS: Metabolite composition of FF changes according to different type of hCG treatment and this can be related to oocyte development and subsequent outcome. According to the data of this study, different types of hCG should be used in relation to the diagnosis of infertility to obtain better results in inducing oocyte maturation in women undergoing IVF.


Assuntos
Gonadotropina Coriônica/metabolismo , Fertilização in vitro/métodos , Líquido Folicular/metabolismo , Metabolômica/métodos , Indução da Ovulação/métodos , Adulto , Feminino , Humanos , Projetos Piloto , Estudos Retrospectivos
7.
Europace ; 22(2): 299-305, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31722381

RESUMO

AIMS: A prolonged PR interval is known to be associated with increased mortality and a higher risk of developing atrial fibrillation (AF). We tested the hypothesis that cardiac resynchronization therapy (CRT) is superior to conventional dual-chamber pacing with algorithms for right ventricular pacing avoidance (DDD-VPA) in preserving systolic and diastolic function and in preventing new-onset AF in patients with normal systolic function, indication for pacing and prolonged atrioventricular conduction (PR interval ≥220 ms). METHODS AND RESULTS: We randomly assigned 82 patients with ejection fraction >35%, indication for pacing and PR interval ≥220 ms to CRT or to DDD-VPA. On 12-month follow-up examination, the study and control arms did not differ in terms of left ventricular end-systolic volume (44 ± 17 mL vs. 47 ± 16 mL, P = 0.511) or ejection fraction (55 ± 6% vs. 57 ± 8%, P = 0.291). The E to A mitral wave amplitude ratio was higher in the CRT arm (1.3 ± 1.3 vs. 0.8 ± 0.4, P = 0.046) and the E wave deceleration time was longer (262 ± 83 ms vs. 205 ± 51 ms, P = 0.027). Left atrial volume was smaller in the CRT arm (64 ± 17 mL vs. 84 ± 25 mL, P = 0.035). Moreover, the functional class was lower in CRT patients (1.4 ± 0.6 vs. 1.8 ± 0.5, P = 0.010). During follow-up, CRT was associated with a lower risk of new-onset AF [hazard ratio = 0.37 (0.13-0.98), P = 0.046]. CONCLUSION: Cardiac resynchronization therapy proved superior to DDD-VPA in terms of better diastolic function, less left atrial enlargement and lower risk of new-onset AF, at 12 months. These data need to be confirmed in a larger trial with longer follow-up. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Identifier: NCT02150538.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Átrios do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Projetos Piloto , Resultado do Tratamento
8.
Metabolomics ; 15(2): 19, 2019 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-30830455

RESUMO

INTRODUCTION: Several metabolomics studies have correlated follicular fluid (FF) metabolite composition with oocyte competence to fertilization, embryo development and pregnancy but there is a scarcity of research examining the metabolic effects of various gynaecological diseases. OBJECTIVES: In this study we aimed to analyze and correlate the metabolic profile of FF from women who were following in vitro fertilization (IVF) treatments with their different infertility pathologies. METHODS: We selected 53 women undergoing IVF who were affected by: tubal diseases, unexplained infertility, endometriosis, polycystic ovary syndrome (PCOS). FF of the study participants was collected at the time of oocytes retrieval. Metabolomic analysis of FF was performed by nuclear magnetic resonance (NMR) spectroscopy. RESULTS: FF presents some significant differences in various infertility pathologies. Although it was not possible to discriminate between FF of control participants and women with tubal diseases and unexplained infertility, comparison of FF metabolic profile from control women with patients with endometriosis and PCOS revealed significant differences in some metabolites that can be correlated to the causes of infertility. CONCLUSION: NMR-based metabolic profiling may be successfully applied to find diagnostic biomarkers for PCOS and endometriosis and it might be also used to predict oocyte developmental potential and subsequent outcome.


Assuntos
Líquido Folicular/citologia , Líquido Folicular/metabolismo , Infertilidade Feminina/etiologia , Adulto , Endometriose/metabolismo , Feminino , Fertilização in vitro/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Metaboloma/fisiologia , Metabolômica/métodos , Oócitos/metabolismo , Indução da Ovulação/métodos , Projetos Piloto , Síndrome do Ovário Policístico/metabolismo , Gravidez
9.
J Interv Card Electrophysiol ; 54(1): 9-15, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30058055

RESUMO

PURPOSE: Reconnection of pulmonary veins (PVs) remains common following radiofrequency catheter ablation for atrial fibrillation (AF). Ablation Index (AI) is a novel ablation quality marker that incorporates stability, contact force (CF), time, and power in a weighted formula. Its use seems to improve lesion durability. This is a prospective, single-arm registry to investigate on the safety and mid-term efficacy of AF ablation guided by the AI. METHODS: One hundred fifty-six consecutive patients (mean age 58 ± 10 years, 49% males, 44% with structural heart disease) referred for paroxysmal (124) or persistent (32) AF underwent antral PV isolation using a surround flow CF-sensing catheter guided by the AI. Radiofrequency was delivered targeting interlesion distance ≤ 6 mm and Ablation Index of 330-350 at posterior wall and 400-450 at anterior wall. RESULTS: Mean overall procedure time was 95 ± 30 min with a mean fluoroscopy time of 5 ± 6 min. Mean ablation time was 26 ± 10 min, 627/628 targeted PV were isolated. One pericardial effusion and two groin hematomas were reported; none required intervention. During a mean follow-up of 14 ± 6 months, 17 (10.8%) (9% paroxysmal AF vs 22% persistent AF, p = 0.09) patients had an atrial arrhythmia recurrence. CONCLUSIONS: PV ablation guided by AI resulted feasible, achieving a high rate of isolated PVs, with a low complication rate, and allowed a high single-procedure arrhythmia-free survival at 14 months.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Segurança do Paciente , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Ablação por Cateter/mortalidade , Distribuição de Qui-Quadrado , Feminino , Fluoroscopia/métodos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Cuidados Pós-Operatórios/métodos , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
10.
J Assist Reprod Genet ; 35(11): 2063-2070, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30069850

RESUMO

PURPOSE: The purpose of this study was to evaluate the possible application of metabolomics to identify follicular fluid changes in cancer patients undergoing fertility preservation. Although metabolomics have been applied already in cancer studies, this is the first application on follicular fluid of cancer patients. METHODS: We selected for the study ten patients with breast cancer and lymphoma who resorted to oocyte cryopreservation to preserve fertility and ten healthy women undergoing in vitro fertilization treatments. Follicular fluid was collected at the time of oocytes retrieval. Metabolomic analysis of follicular fluids was performed by 1H-nuclear magnetic resonance (NMR) spectroscopy in combination with multivariate analysis to interpret the spectral data. Univariate statistical analysis was applied to find correlations between patients' features and metabolites identified by NMR. RESULTS: Partial least squares discriminant analysis allowed to discriminate samples from cancer patients and healthy controls. Univariate statistical analysis found significant correlations between patients' features and metabolites identified by NMR. This finding allowed to identify biomarkers to differentiate both healthy controls from cancer patients and the two different classes of oncological patients. CONCLUSION: The follicular fluids of cancer patients display significant metabolic alterations in comparison to healthy subjects. NMR-based metabolomics could be a valid prognostic tool for identifying and selecting the best cryopreserved oocytes and improving the outcome prediction in cancer women undergoing in vitro fertilization.


Assuntos
Biomarcadores/metabolismo , Neoplasias da Mama/metabolismo , Preservação da Fertilidade , Líquido Folicular/metabolismo , Linfoma/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Metabolômica , Adulto , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Feminino , Humanos , Linfoma/patologia , Adulto Jovem
11.
Heart Rhythm ; 15(11): 1675-1682, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29665405

RESUMO

BACKGROUND: Professional guidelines are based on the best available evidence. However, patients treated in clinical practice may differ from those included in reference trials. OBJECTIVE: The aim of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) in a large population of patients implanted with a CRT device stratified in accordance with the 2016 European heart failure (HF) guidelines. METHODS: We collected data on 930 consecutive patients from the Cardiac Resynchronization Therapy MOdular REgistry. The primary end point was a composite of death and HF hospitalization. RESULTS: Five hundred sixty-three (60.5%) patients met class I indications, 145 (15.6%) class IIa, 108 (11.6%) class IIb, and 114 (12.3%) class III. After a median follow-up of 1001 days, 120 (14.7%) patients who had an indication to CRT had died and 71 (8.7%) had been hospitalized for HF. The time to the end point was longer in patients with a class I indication (hazard ratio 0.55; 95% confidence interval 0.39-0.76; P = .0001). After 12 months, left ventricular (LV) end-systolic volume had decreased by ≥15% in 61.5% (320/520) of patients whereas in 57.5% (389/676) of patients the absolute LV ejection fraction improvement was ≥5%. Adherence to class I was also associated with an absolute LV ejection fraction increase of >5% (P = .0142) and an LV end-systolic volume decrease of ≥15% (P = .0055). CONCLUSION: In our population, ∼60% of patients underwent implantation according to the 2016 European HF guidelines class I indication. Adherence to class I was associated with a lower death and HF hospitalization rates and better LV reverse remodeling.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiologia , Fidelidade a Diretrizes , Insuficiência Cardíaca/terapia , Sistema de Registros , Sociedades Médicas , Volume Sistólico/fisiologia , Idoso , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Taxa de Sobrevida/tendências , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
12.
J Interv Card Electrophysiol ; 51(3): 245-252, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29502194

RESUMO

PURPOSE: Latency during left ventricle (LV) pacing has been suggested as a potential cause of ineffectual biventricular pacing. We assessed the incidence, predictors, and impact on outcome of increased LV latency in 274 patients undergoing cardiac resynchronization therapy (CRT). METHODS: On implantation, the latency interval was defined as the shortest stimulus-to-QRS onset interval in any lead of the 12-lead ECG. A stimulus-to-QRS onset interval ≥ 40 ms was used to define the presence of increased LV latency. RESULTS: Increased LV latency was observed in 55 patients (20%). On multivariate analysis, only ischemic etiology proved to be a predictor of increased LV latency. On 12-month echocardiographic evaluation, 68% patients showed a ≥ 15% decrease in LV end systolic volume (74% patients with increased LV latency, 67% patients without increased LV latency (p = 0.58). The presence of increased LV latency was not associated with a different clinical response to CRT. CONCLUSIONS: Increased LV latency occurred in almost 20% of patients undergoing CRT and was more frequent in patients with ischemic heart disease. The presence of increased LV latency does not seem to have an impact on echocardiographic or clinical response to CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Insuficiência Cardíaca/terapia , Isquemia Miocárdica/terapia , Idoso , Análise de Variância , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia
13.
J Assist Reprod Genet ; 34(11): 1537-1545, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28776117

RESUMO

PURPOSE: The purpose this study is to investigate whether a double antagonist dose (0.25 mg/12 h) administered the day before hCG trigger is effective in preventing ovarian hyperstimulation syndrome (OHSS) in GnRH antagonist IVF/intracytoplasmic sperm injection (ICSI) cycles at risk for OHSS. METHODS: This is a prospective randomized control study, conducted from November 2012 to January 2016. A total of 194 patients undergoing a IVF/ICSI GnRH antagonist cycle that were at risk of OHSS and chose to proceed with embryo transfer and avoid cycle cancellation or embryo cryopreservation were allocated into two groups. The inclusion criteria consisted of a rapid rise of oestradiol ≥ 3500 pg/ml combined with ≥ 18 follicles > 11 mm in diameter without any mature follicle > 16 mm, in any day of stimulation. Overall, 97 patients (intervention group A) received a double dose of GnRH antagonist (0.25 mg/12 h) the day before hCG while 97 patients (control group B) did not. Recombinant FSH administration was tapered to 100 IU/24 h the day of the allocation in both groups. RESULTS: Incidence of early-onset moderate/severe OHSS was significantly lower in intervention group A compared to control group B (0 vs 12.37%, P < 0.001). Clinical pregnancy rate per cycle (50.52 vs 42.27%, P = 0.249) was not significantly different between the two groups. Oestradiol (3263.471 ± 1271.53 vs 5233 ± 1425.17, P < 0.001), progesterone (0.93 ± 0.12 vs 1.29 ± 0.14, P < 0.001) and luteinizing hormone (1.42 ± 0.31 vs 1.91 ± 0.33, P < 0.001) were significantly lower in group A the day of the hCG triggering. CONCLUSION: The administration of a rescue double GnRH antagonist dose the day before hCG trigger may represent a safe alternative preventive strategy for early OHSS without affecting the reproductive outcomes. TRIAL REGISTRATION NUMBER: ISRCTN02750360.


Assuntos
Gonadotropina Coriônica/administração & dosagem , Fertilização in vitro/métodos , Hormônio Liberador de Gonadotropina/antagonistas & inibidores , Antagonistas de Hormônios/administração & dosagem , Síndrome de Hiperestimulação Ovariana/prevenção & controle , Adulto , Implantação do Embrião/efeitos dos fármacos , Transferência Embrionária/métodos , Estradiol/administração & dosagem , Feminino , Humanos , Folículo Ovariano/efeitos dos fármacos , Folículo Ovariano/crescimento & desenvolvimento , Síndrome de Hiperestimulação Ovariana/tratamento farmacológico , Síndrome de Hiperestimulação Ovariana/patologia , Indução da Ovulação/métodos , Gravidez , Taxa de Gravidez , Injeções de Esperma Intracitoplásmicas/métodos
14.
J Interv Card Electrophysiol ; 50(1): 111-115, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28798987

RESUMO

PURPOSE: Identifying the left ventricular (LV) site associated with the maximum spontaneous interventricular conduction time (right ventricle (RV)-to-LV interval) has proved to be an effective strategy for optimal LV pacing site selection in cardiac resynchronization therapy (CRT). The aim of our study was to determine whether quadripolar LV lead technology allows RV-to-LV interval maximization. METHODS: We enrolled 108 patients undergoing implantation of a CRT system using an LV quadripolar lead and 114 patients who received a bipolar lead. On implantation, the RV-to-LV interval was measured for the dipole of the bipolar leads and for each electrode of the LV lead (tip, ring 2, ring 3, ring 4). RESULTS: In the quadripolar group, the mean RV-to-LV interval ranged from 90 ± 33 ms (tip) to 94 ± 32 ms (R4) (p > 0.05 for all comparisons). In 55 (51%) patients, the RV-to-LV interval was > 80 ms at all electrodes, while in 27 (25%) patients, no electrodes were associated with an RV-to-LV interval > 80 ms. At least one LV pacing electrode was associated with an RV-to-LV interval > 80 ms in 62 (70%) patients with a short (36 mm) inter-electrode distance, and in 19 (95%, p = 0.022) of those with a long distance (50.5 mm). In the bipolar group, the mean RV-to-LV interval was 72 ± 37 ms (p < 0.001 versus quadripolar). The RV-to-LV interval was > 80 ms in 44 (39%) patients (p < 0.001 versus quadripolar leads with both short and long inter-electrode distance). CONCLUSIONS: Quadripolar leads allow RV-to-LV interval maximization. An optimal RV-to-LV interval seems achievable in the majority of patients, especially if the leads present a long inter-electrode distance.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/mortalidade , Estudos de Coortes , Eletrocardiografia/métodos , Feminino , Sistema de Condução Cardíaco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Normal , Prognóstico , Sistema de Registros , Medição de Risco , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 28(7): 762-767, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28422368

RESUMO

INTRODUCTION: Pulmonary vein (PV) isolation is the cornerstone of catheter ablation in patients with atrial fibrillation (AF). Surround flow and contact force (CF) measurement capabilities might enhance procedure efficacy and safety. We report on the safety and midterm efficacy of a novel ablation catheter for PV isolation in patients with AF. METHODS AND RESULTS: Two hundred thirty-three consecutive patients (57 ± 11 years, 76% males, 51% with structural heart disease), referred for paroxysmal (157) or persistent (76) AF, underwent PV isolation by a surround flow catheter with CF measurement capability in four centers. Ablation was guided by electroanatomic mapping allowing radiofrequency (RF) energy delivery in the antral region aiming at PV isolation. Mean overall procedure time was 100 ± 42 minutes with a mean fluoroscopy time of 6 ± 5 minutes. Mean ablation time was 31±15 minutes; 99% of the targeted veins were isolated. The mean CF value during ablation was 13 ± 4 g. Intraprocedural early (30 minutes) PV reconnection occurred in 12% PVs, and all PVs were effectively reisolated. One pericardial effusion and five groin hematomas were reported. During a mean follow-up of 12 ± 6 months, 30 (12.9%) (10% paroxysmal AF vs. 18% persistent AF, P = 0.07) patients had an atrial arrhythmias recurrence. CONCLUSIONS: In this multicenter registry, RF ablation using a new surround flow catheter, with CF sensor, resulted as feasible, achieving a high rate of isolated PVs. Procedural and fluoroscopy times and success rates were comparable with other techniques with a low complication rate.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Sistema de Registros , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
16.
J Interv Card Electrophysiol ; 48(2): 201-207, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27714605

RESUMO

PURPOSE: Left atrial volume (LA) and pulmonary vein (PV) anatomy may potentially relate to technical challenges in achieving stable and effective catheter position in case of atrial fibrillation (AF) ablation by means of "one-shot" catheters. The aim of this study was to investigate whether LA volume and PV anatomy, evaluated by computed tomography (CT) or magnetic resonance (MR) prior to ablation, predict acute and midterm outcome of AF ablation by nMARQ™. METHODS: We included 75 patients (mean age 58 ± 11 years, 67 % male) with symptomatic paroxysmal AF. All patients underwent CT/MR scanning prior to catheter ablation to evaluate LA volume and PV anatomy. All the patients underwent PV isolation by nMARQ™, an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter. Ablation was guided by electroanatomic mapping allowing RF energy delivery in the antral region of PVs from ten irrigated electrodes simultaneously. RESULTS: Mean LA volume was 75 ± 40 ml. A normal anatomy (4 PVs) was documented in 40 (53 %) patients and abnormal anatomy (common truncus or accessory PVs) in 35 patients. Mean procedural and fluoroscopy times were 94 ± 55 and 8 ± 5 min, respectively, without significant differences among patients with normal or abnormal anatomy (92 ± 45 vs 95 ± 64 min, p = 0.85 and 6 ± 3 vs 8 ± 4 min, p = 0.65, respectively). Mean ablation time was 14 ± 3 min, and 99 % of the targeted veins were isolated with a mean of 23 ± 5 RF pulses per patient. After a mean follow-up of 17 ± 8 months, 23 (31 %) patients had an atrial arrhythmia recurrence. Neither LA volume nor PV anatomy was a predictor of outcome. CONCLUSIONS: LA volume and PV anatomy did not affect procedural data and outcome in patients who underwent PV isolation by an open-irrigated mapping and RF decapolar ablation catheter.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/patologia , Veias Pulmonares/patologia , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mapeamento Potencial de Superfície Corporal/métodos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Irrigação Terapêutica , Resultado do Tratamento , Adulto Jovem
18.
Heart Rhythm ; 12(8): 1782-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26004941

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation is the cornerstone of catheter ablation in patients with atrial fibrillation (AF). "Single-shot" ablation devices have been recently engineered. OBJECTIVES: We report on the safety and efficacy of a novel ablation catheter for PV isolation in patients with AF. METHODS: One hundred eighty consecutive patients (58 ± 10 years, 125 male, 31% with structural heart disease) referred for paroxysmal (140) or persistent (40) AF underwent PV isolation by an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter in 7 centers. Ablation was guided by electroanatomic mapping, allowing RF energy delivery in the antral region of PVs from 10 irrigated electrodes simultaneously. RESULTS: Mean overall procedure time was 113 ± 53 minutes with a mean fluoroscopy time of 13.1 ± 8.4 minutes. The use of a preablation PV imaging related to a significant reduction in fluoroscopy time (from 14.7 ± 9.7 to 8.7 ± 6.6, P < .001). Mean ablation time was 12.5 ± 5.1 minutes, and 98% of the targeted veins were isolated with a mean of 23.4 ± 6.3 RF pulses per patient. In only 4 patients (2.2%) a single-point ablation strategy was required to achieve PV isolation. One groin hematoma and 1 PV stenosis were reported. During a mean follow-up of 13.9 ± 8.2 months 38 of 140 patients (27%) with paroxysmal AF and 12 of 40 patients (30%) with persistent AF had an atrial arrhythmia relapse (P = .671). CONCLUSIONS: In this multicenter registry, irrigated multielectrode RF ablation proved feasible, achieving a high rate of isolated PVs. Procedural and fluoroscopy times and success rates were comparable with other techniques, with a low complication rate.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Desenho de Equipamento/métodos , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
19.
Hellenic J Cardiol ; 56(3): 230-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26021245

RESUMO

INTRODUCTION: We evaluated the potential ability of the electrophysiological (EP) inducibility of ventricular arrhythmias to predict the likelihood of appropriate ICD intervention over the long-term in ischemic and nonischemic patients with current primary prevention indications for ICD implantation. METHODS: Between 2006 and 2008, 206 consecutive heart failure patients who were candidates for ICD implantation for the primary prevention of sudden cardiac death according to standard indications underwent EP testing, usually on ICD implantation. RESULTS: On EP testing, 15 (7%) patients had inducible monomorphic ventricular tachycardia (VT) and 14 (7%) ventricular fibrillation (VF). Over 24 months, 64 (31%) patients received appropriate ICD therapies: 51 (25%) for VT and 16 (8%) for VF. The time to the first appropriate ICD therapy trended to be shorter in the group of patients who were inducible on EP testing (p=0.072). Among patients receiving appropriate therapies, the median number of arrhythmic episodes was 2, and the proportion of patients with 2 treated arrhythmic episodes was higher in the group of inducible patients (34% versus 14%, p=0.005). On multivariate analysis, inducibility proved to be an independent predictor of frequent (2) arrhythmic episodes, as did a history of coronary artery bypass grafting. Moreover, patients with 2 treated arrhythmic episodes showed higher mortality (log-rank test, p=0.042). CONCLUSION: Patients with inducibility of VT or VF are more likely to experience frequent appropriate ICD therapies during follow up.


Assuntos
Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Cardiomiopatia Dilatada/terapia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia
20.
Heart Rhythm ; 12(11): 2221-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26001509

RESUMO

BACKGROUND: The implantation strategy appears to play a pivotal role in determining response to cardiac resynchronization therapy (CRT). OBJECTIVE: The aim of our study was to determine the association between anatomic and electrical interlead distance and clinical outcome after CRT implantation. METHODS: We included 216 first-time CRT recipients with left bundle branch block and sinus rhythm. On implantation, the electrical interlead distance (EID), defined as the time interval between spontaneous peak R waves detected at the right ventricular (RV) and left ventricular (LV) pacing sites, was measured. The anatomic distance between the RV and LV lead tips was determined on chest radiographs. RESULTS: The mean EID was 74 ± 41 ms, and the mean horizontal corrected interlead distance (HCID) was 125 ± 73 mm. After 12 months, 87 patients (40%) displayed an improvement in their clinical composite score. The cutoff values that best predicted an improved clinical status were as follows: 84 ms for EID (area under the curve 0.59; confidence interval [CI] 0.52-0.66; P = .026) and 90 mm for HCID (area under the curve 0.62; CI 0.55-0.69; P = .004). On multivariate analysis, only EID >84 ms (hazard ratio 0.36; CI 0.14-0.89; P = .028) and HCID >90 mm (hazard ratio 0.45; CI 0.23-0.90; P = .025) were significantly associated with the composite endpoint of death or cardiovascular hospitalization. In particular, the presence of both conditions (EID <84 ms and HCID <90 mm) was associated with the highest rate of events (log-rank test P = .002). CONCLUSIONS: The interlead anatomic and electrical distance are strongly and independently associated with patient outcome after CRT implantation. The 2 measures show an additive predictive value. (CRT MORE: Cardiac Resynchronization Therapy Modular Registry; www.clinicaltrials.gov, unique identifier: NCT01573091.)


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados , Marca-Passo Artificial , Estudos de Coortes , Eletrocardiografia/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Radiografia Torácica , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA