Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Noninvasive Electrocardiol ; 29(5): e70004, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39101582

RESUMO

BACKGROUND: The fibrosis-5 (FIB-5) index is a noninvasive marker for assessing the progression of liver fibrosis and predictor in patients with heart failure (HF). This study investigated the association between the FIB-5 index and response to cardiac resynchronization therapy (CRT) and evaluated its predictive value for prognosis. METHODS: In total, 203 patients who underwent CRT/CRT-defibrillator (CRT-D) implantation were retrospectively included. The FIB-5 index was calculated using blood samples obtained before and after CRT/CRT-D. Response to CRT was defined as a relative reduction in left ventricular end-systolic volume of ≥15% 6 months after CRT/CRT-D. We compared the prognosis after CRT/CRT-D between the groups according to the FIB-5 index. RESULTS: One hundred and twenty-three patients (61%) responded to CRT. The responder group demonstrated a significantly higher FIB-5 index than the nonresponder group (-2.76 ± 3.85 vs. -4.67 ± 3.29, p < 0.001). Receiver-operating characteristic analysis demonstrated that the area under the curve of the FIB-5 index was 0.660 with a cutoff value of -4.00 for responders. In multivariate analysis, FIB-5 index ≥ -4.00 was an independent predictor for CRT response (odds ratio: 3.665, p = 0.003), in addition to QRS duration ≥ 150 ms and echocardiographic dysynchrony. The FIB-5 index increased significantly after 6 months in the responder group but not in the nonresponder group. The FIB-5 index ≥ -4.00 group showed a significantly better prognosis for cardiac death, HF hospitalization, and composite endpoint than the FIB-5 index < -4.00 group. CONCLUSION: The FIB-5 index in addition to classical predictors may be a useful marker for predicting response to CRT.


Assuntos
Biomarcadores , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Cirrose Hepática , Humanos , Masculino , Feminino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/sangue , Cirrose Hepática/terapia , Cirrose Hepática/sangue , Cirrose Hepática/fisiopatologia , Cirrose Hepática/complicações , Prognóstico , Estudos Retrospectivos , Biomarcadores/sangue , Idoso , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 35(4): 821-831, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38424678

RESUMO

INTRODUCTION: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter-defibrillators using a unique setting of different sequential orders of both ATP algorisms. METHODS: Patients with the iATP algorithm were assigned to iATP-first and conventional ATP-first groups sequentially. In the iATP-first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP-first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups. RESULTS: Fifty-eight and 56 patients were enrolled in the iATP-first and conventional ATP-first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). CONCLUSIONS: iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial/efeitos adversos , Trifosfato de Adenosina
4.
Artigo em Inglês | MEDLINE | ID: mdl-37855993

RESUMO

BACKGROUND: The fibrosis-4 (FIB-4) index is a noninvasive scoring system that is used to assess the progression of liver fibrosis. This study aimed to assess whether the FIB-4 index is associated with recurrent atrial fibrillation (AF) after catheter ablation in patients with and without heart failure (HF). METHODS: We included 1,184 patients who underwent initial AF catheter ablation between 2016 and 2021. The patients were classified into low-risk (< 1.3), intermediate-risk (1.3-2.67), and high-risk (> 2.67) groups based on their FIB-4 indices at baseline. The patients were divided into HF (n = 552) and non-HF groups (n = 632); the HF group was further divided into paroxysmal AF (PAF) and non-PAF groups. AF recurrence after catheter ablation was then compared among the groups. RESULTS: In the non-HF group, no significant differences in recurrence after ablation were observed between the low-(n = 219), intermediate-(n = 364), and high-risk (n = 49) groups. In contrast, in the HF group, the intermediate-(n = 341) and high-risk (n = 112) groups had significantly higher recurrence rates than the low-risk group (n = 99) (log-rank test, p = 0.005). This association remained significant after multivariate analysis (hazard ratio [HR]:1.374; p = 0.027). The FIB-4 index increased incrementally as the brain natriuretic peptide levels and severity of tricuspid regurgitation increased. The FIB-4 index was an independent predictor of recurrence in the non-PAF HF group (HR:1.498; p = 0.007) but not in the PAF group. CONCLUSIONS: The FIB-4 index may be a useful predictor of AF recurrence after catheter ablation in patients with HF, particularly in those with non-PAF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA