Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
2.
Echocardiography ; 40(11): 1177-1186, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37725335

RESUMO

BACKGROUND: Left ventricle (LV) optimized views are routinely used for left atrial (LA) volume and strain measurements on 2D echocardiography. This might be a source of the error because of the variation of the angle between the left atrial and left ventricle long axes (LA-LV angle), leading to foreshortening of the LA. METHODS: We investigated two novel parameters: the angle between the left atrial and left ventricle long axes (LA-LV angle) and its deviation from the 4-chamber plane. To accurately measure the angles in 3D space, these measurements were performed using 3D echocardiography. We developed a method for the measurement based on marking anatomic points of reference in the 3D echocardiogram and measuring the angles between these points. We used three types of phantoms made of wood and agar-agar to investigate the repeatability and reproducibility of these measurements and performed measurements on human subjects. RESULTS: The ultrasound measurements were in excellent agreement with the true angles of the phantoms: LA-LV angle bias was .5 degrees (95% CI -1.8 to +2.7) in the wooden phantoms and 1.2 degrees (-.7 to +3.1) in the agar-agar phantoms, while the angle deviation from the 4-chamber plane was -.9 degrees (-4.3 to +4.1) in the wooden phantoms and .0 degrees (-3.3 to +3.3) in the agar-agar phantoms. The measurements demonstrated good repeatability and reproducibility (Pearson correlation coefficients ranging from .91 to .99). The measurements from human hearts showed good repeatability (Pearson correlation was .81 for repeated LA-LV angle measurements and .97 for repeated measurements of the deviation from the 4-chamber plane). CONCLUSION: The measurement of the LA-LV angle is a feasible tool to investigate one eventual error of 2D echocardiography.


Assuntos
Fibrilação Atrial , Ecocardiografia Tridimensional , Humanos , Ventrículos do Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Ágar , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem
3.
Clin Physiol Funct Imaging ; 43(4): 291-296, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36757012

RESUMO

INTRODUCTION AND METHODS: There is limited knowledge of cumulative effect of repetitive cold-water diving on cardiac function. Single cold dives cause some known cardiological risks, such as malign arrhythmia, due to a concurrent activation of the sympathetic and parasympathetic autonomic nervous system. A previous study from warmer water dives has shown that successive dives cause a decrease in vagal tone and a less responsive cardiovascular system. The aim of this study was to evaluate changes in cardiac function with 2D echocardiography during 4 days of diving in near-freezing water. RESULTS: Left ventricle systolic function measures did not show any uniform changes. E/A ratio seemed to decrease successively with the number of dives. The diastolic tissue velocity of relaxing basal septum (e') showed a decreasing trend as well. Diastolic blood pressure seemed to increase from predive (mean: 83 RR mmHg) to postdive values (mean: 87 RR mmHg) (p=NS). Heart rate decreased significantly from predive (mean: 71 bpm, range: 56-103) to postdive values (mean: 60 bpm, range: 37-88) (p < 0.03). DISCUSSION AND CONCLUSIONS: The study was conducted in very cold condition and with limited number of divers. Results of this preliminary study suggested a decreasing trend in left ventricular diastolic function in successive cold dives. Cumulative changes in cardiac function may cause health risks that need to be considered during cold water diving operations.


Assuntos
Mergulho , Humanos , Mergulho/efeitos adversos , Mergulho/fisiologia , Pressão Sanguínea/fisiologia , Função Ventricular Esquerda , Ecocardiografia , Água
4.
Int J Cardiovasc Imaging ; 38(11): 2395-2402, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36434329

RESUMO

To elucidate underlying disease mechanisms, we compared transition of gadolinium-based contrast agent bolus in cardiac chambers in magnetic resonance imaging between young patents with cryptogenic ischemic stroke and stroke-free controls. We included 30 patients aged 18-50 years with cryptogenic ischemic stroke from the prospective Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (NCT01934725) study and 30 age- and gender-matched stroke-free controls. Dynamic contrast-enhanced T1-weighted first-pass perfusion images were acquired at 1.5 T and analyzed for transit time variables, area under curves, relative blood flow, and maximum and minimum enhancement rates in left atrial appendage, left atrium, and left ventricle. These data were compared with previously published left ventricular non-compaction data of the same study population. Arrival time of contrast agent bolus in superior vena cava was similar in patients and controls (6.7[2.0] vs. 7.1[2.5] cardiac cycles, P = 0.626). Arrival and peak times showed comparable characteristics in patients and controls (P > 0.535). The minimum enhancement rate of the left ventricle was lower in patients than in controls (- 28 ± 11 vs. - 36 ± 13 1/(cardiac cycle), P = 0.012). Area under curves, relative blood flow, and other enhancement rates showed no significant differences between patients and controls (P > 0.107). Relative blood flow of cardiac chambers correlated with non-compacted left ventricular volume ratio (P < 0.011). Our results indicate slower washout of contrast agent and blood flow stagnation in the left ventricle of young patients with cryptogenic ischemic stroke. The washout was associated with left ventricular non-compaction, suggesting conditions favoring formation of intraventricular thrombosis.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Meios de Contraste , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Veia Cava Superior , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade
5.
Cardiology ; 147(2): 169-178, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35073556

RESUMO

PURPOSE: There is growing evidence that paradoxical embolism through patent foramen ovale (PFO) is a cause for cryptogenic stroke. However, it is still unclear why the foramen ovale fails to close after birth. We studied whether the 3D relations between the atrial septum (AS) and the inferior vena cava (IVC) are associated with PFO. METHODS: We recruited 30 patients (18-49 years) with a first-ever cryptogenic stroke and 30 age- and sex-matched stroke-free controls. Using cardiac magnetic resonance, an approach to evaluate the 3D relations between the AS and the IVC was developed. The presence of interatrial right-to-left shunt was evaluated with transesophageal echocardiography (TEE) in patients and transcranial Doppler in controls. RESULTS: Of 30 patients, 29 underwent successful TEE, of which 12 (41%) had a shunt. Patients with a shunt had a greater mean 3D angle (γ) between the atrial septal plane and the vector from the orifice of the IVC to the middle of the AS compared with patients without a shunt (45 ± 9° vs. 36 ± 8°, p = 0.017). Of 30 controls, 12 (40%) had a shunt and a greater mean γ compared with controls without a shunt (47 ± 8° vs. 37 ± 10°, p = 0.007). In a pooled analysis, 24 (41%) of 59 subjects with a shunt had a mean γ of 46 ± 9° compared with subjects without a shunt of 37 ± 9° (p < 0.001). CONCLUSIONS: More perpendicular orientation of the atrial septal plane to the orifice of the IVC is associated with PFO, possibly by directing the IVC flow to PFO.


Assuntos
Septo Interatrial , Embolia Paradoxal , Forame Oval Patente , Forame Oval , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Embolia Paradoxal/complicações , Embolia Paradoxal/etiologia , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Humanos , Veia Cava Inferior/diagnóstico por imagem
6.
BMC Med Imaging ; 21(1): 167, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34753444

RESUMO

BACKGROUND: Accurate measurement of left atrial (LA) volumes is needed in cardiac diagnostics and the follow up of heart and valvular diseases. Geometrical assumptions with 2D methods for LA volume estimation contribute to volume misestimation. In this study, we test agreement of 3D and 2D methods of LA volume detection and explore contribution of 3D LA axis orientation and LA shape in introducing error in 2D methods by cardiovascular magnetic resonance imaging. METHODS: 30 patients with prior first-ever ischemic stroke and no known heart disease, and 30 healthy controls were enrolled (age 18-49) in a substudy of a prospective case-control study. All study subjects underwent cardiac magnetic resonance imaging and were pooled for this methodological study. LA volumes were calculated by biplane area-length method from both conventional long axis (LAVAL-LV) and LA long axis-oriented images (LAVAL-LA) and were compared to 3D segmented LA volume (LAVSAX) to assess accuracy of volume detection. 3D orientation of LA long axis to left ventricular (LV) long axis and to four-chamber plane were determined, and LA 3D sphericity indices were calculated to assess sources of error in LA volume calculation. Shapiro-Wilk test, Bland-Altman analysis, intraclass and Pearson correlation, and Spearman's rho were used for statistical analysis. RESULTS: Biases were - 9.9 mL (- 12.5 to - 7.2) for LAVAL-LV and 13.4 (10.0-16.9) for LAVAL-LA [mean difference to LAVSAX (95% confidence interval)]. End-diastolic LA long axis 3D deviation angle to LV long axis was 28.3 ± 6.2° [mean ± SD] and LA long axis 3D rotation angle to four-chamber plane 20.5 ± 18.0°. 3D orientation of LA axis or 3D sphericity were not correlated to error in LA volume calculation. CONCLUSIONS: Calculated LA volume accuracy did not improve by using LA long axis-oriented images for volume calculation in comparison to conventional method. We present novel data on LA axis orientation and a novel metric of LA sphericity and conclude that these measures cannot be utilized to assess error in LA volume calculation. TRIAL REGISTRATION: Main study Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) has been registered previously.


Assuntos
Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos
7.
Open Heart ; 8(1)2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34006504

RESUMO

BACKGROUND: Recent studies suggest left atrial (LA) dysfunction in cryptogenic stroke. We studied the dynamics of right atrium (RA) and right atrial appendage (RAA) in young adults with cryptogenic stroke. We hypothesised that bi-atrial dysfunction and blood stagnation might contribute to thrombosis formation in patients with patent foramen ovale (PFO), as deep venous thrombosis is detected only in the minority of patients. METHODS: Thirty patients (aged 18-49) with a first-ever cryptogenic stroke and 30 age-matched and sex-matched stroke-free controls underwent cardiac magnetic resonance (CMR) imaging. An approach to estimate the RAA volume was developed, using crista terminalis and pectinate muscles as anatomical landmarks. Atrial expansion indices were calculated as (maximal volume - minimal volume) ×100%/minimal volume. Total pulmonary to systemic blood flow ratio (Qp/Qs) was based on phase contrast CMR. Right-to-left shunt (RLS) was evaluated with transoesophageal echocardiography in 29 patients and transcranial Doppler in 30 controls, moderate-to-severe RLS considered as clinically significant. RESULTS: We found that RA and RAA volumes were similar between patients and controls. Also, RA expansion index was similar, but RAA (95.6%±21.6% vs 108.7%±25.8%, p=0.026) and LA (126.2%±28% vs 144.9%±36.3%, p=0.023) expansion indices were lower in patients compared with controls. Seven (24%) of 29 patients had an RLS compared with 1 (3%) of 30 controls (p=0.012). Among 59 study subjects, RLS was associated with lower RA (81.9%±15.9% vs 98.5%±29.5%, p=0.030), RAA (84.7%±18% vs 105.6%±24.1%, p=0.022), LA (109.8%±18.6% vs 140.1%±33.7%, p=0.017) and LAA (median 102.9% (IQR 65.6%-121.7%) vs 229.1% (151.8%-337.5%], p=0.002) expansion indices and lower Qp/Qs ratio (0.91±0.06 vs 0.98±0.07, p=0.027). CONCLUSIONS: This study suggests bi-atrial dysfunction in young adults with cryptogenic stroke, associated with moderate-to-severe RLS. Dysfunction of the atria and atrial appendages may be an additional mechanism for PFO-related stroke. TRIAL REGISTRATION NUMBER: NCT01934725.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Função do Átrio Direito/fisiologia , Ecocardiografia Transesofagiana/métodos , AVC Isquêmico/etiologia , Imagem Cinética por Ressonância Magnética/métodos , Ultrassonografia Doppler Transcraniana/métodos , Disfunção Ventricular Direita/complicações , Adolescente , Adulto , Apêndice Atrial/fisiopatologia , Estudos de Casos e Controles , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , AVC Isquêmico/diagnóstico , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
8.
Echocardiography ; 38(2): 271-279, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33484598

RESUMO

INTRODUCTION: Ischemic stroke in young patients often remains cryptogenic, that is, no underlying reason can be found. Some of these strokes may originate in the heart. Left ventricular (LV) dynamic volumetry and strain analysis are relatively new and promising methods for evaluating LV function. METHODS: In this pilot study, we recruited 30 young (18-50 years) patients with cryptogenic ischemic stroke and 30 age- and sex-matched controls from the SECRETO study (NCT01934725). The LV systolic function was assessed by LV volumetry (ejection fraction, peak emptying rate, and time to peak emptying rate). The longitudinal systolic function was assessed by speckle tracking strain and strain rate imaging, and by tissue velocity imaging derived MAD (mitral annular displacement) and septal S'. RESULTS: Stroke patients had less vigorous global longitudinal strain (median -18.9, interquartile range 3.3), compared to healthy controls (median -20.0, interquartile range 2.8), P = .010. There was no statistically significant differences in septal S', MAD, global longitudinal strain rate, or dynamic volumetry-derived parameters between the two groups. CONCLUSIONS: Young cryptogenic stroke patients have subtly altered systolic function compared to healthy controls, found merely with longitudinal strain analysis. This infers that the heart may play a role in the pathogenesis of cryptogenic ischemic stroke.


Assuntos
AVC Isquêmico , Disfunção Ventricular Esquerda , Humanos , Projetos Piloto , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
9.
PLoS One ; 15(8): e0237228, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32797064

RESUMO

BACKGROUND: Up to 50% of ischemic strokes in the young after thorough diagnostic work-up remain cryptogenic or associated with low-risk sources of cardioembolism such as patent foramen ovale (PFO). We studied with cardiac magnetic resonance (CMR) imaging, whether left ventricular (LV) non-compaction-a possible source for embolic stroke due to sluggish blood flow in deep intertrabecular recesses-is associated with cryptogenic strokes in the young. METHODS: Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) is an international prospective multicenter case-control study of young adults (aged 18-49 years) presenting with an imaging-positive first-ever ischemic stroke of undetermined etiology. In this pilot substudy, 30 cases and 30 age- and sex-matched stroke-free controls were examined with CMR. Transcranial Doppler (TCD) bubble test was performed to evaluate the presence and magnitude of right-to-left shunt (RLS). RESULTS: There were no significant differences in LV volumes, masses or systolic function between cases and controls; none of the participants had non-compaction cardiomyopathy. Semi-automated assessment of LV non-compaction was highly reproducible. Non-compacted LV mass (median 14.0 [interquartile range 12.6-16.0] g/m2 vs. 12.7 [10.4-16.6] g/m2, p = 0.045), the ratio of non-compacted to compacted LV mass (mean 25.6 ± 4.2% vs. 22.8 ± 6.0%, p = 0.015) and the percentage of non-compacted LV volume (mean 17.6 ± 2.9% vs. 15.7 ± 3.8%, p = 0.004) were higher in cases compared to controls. In a multivariate conditional logistic regression model including non-compacted LV volume, RLS and body mass index, the percentage of non-compacted LV volume (odds ratio [OR] 1.55, 95% confidence interval [CI] 1.10-2.18, p = 0.011) and the presence of RLS (OR 11.94, 95% CI 1.14-124.94, p = 0.038) were independently associated with cryptogenic ischemic stroke. CONCLUSIONS: LV non-compaction is associated with a heightened risk of cryptogenic ischemic stroke in young adults, independent of concomitant RLS and in the absence of cardiomyopathy. CLINICAL TRIAL REGISTRATION: SECRETO; NCT01934725. Registered 4th September 2013. https://clinicaltrials.gov/ct2/show/NCT01934725.


Assuntos
Isquemia Encefálica/fisiopatologia , Ventrículos do Coração/fisiopatologia , Acidente Vascular Cerebral/fisiopatologia , Adolescente , Adulto , Isquemia Encefálica/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Adulto Jovem
10.
Clin Physiol Funct Imaging ; 40(5): 336-342, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32406978

RESUMO

BACKGROUND: Ischaemic stroke in young individuals often remains cryptogenic. In this pilot study, we investigated, whether advanced echocardiography methods could find differences in the diastolic function between young cryptogenic stroke patients and stroke-free controls. METHODS: We recruited 30 cryptogenic ischaemic stroke patients aged 18-49 and 30 age- and sex-matched stroke-free controls among participants of the Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO) study (NCT01934725). We measured diastolic function parameters derived from speckle tracking strain rate, Doppler techniques and 4D volumetry. We also performed statistical analyses comparing only the highest and lowest tertile of cases and controls for each parameter. RESULTS: None of our patients or controls had diastolic dysfunction according to ASE/EACVI criteria. However, compared to stroke-free controls, the stroke patient group had lower E/A ratio of mitral inflow, lower lateral and mean e', lower A/a' ratio, lower strain rate in early diastole and lower speckle tracking-derived e/a ratio. When comparing the lowest tertiles, patients also had a lower peak filling rate by 4D volumetry, a lower peak early filling fraction (fraction of left ventricular filling during early diastole), and lower velocities in a series of the tissue Doppler-derived diastolic parameters and blood flow/tissue velocity ratios. CONCLUSION: Our study displayed subtle differences in diastolic function between patients and stroke-free controls, which may play a role in early-onset cryptogenic stroke. The differences were clearer when the lowest tertiles were compared, suggesting that there is a subgroup of young cryptogenic stroke patients with subclinical heart disease.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Disfunção Ventricular Esquerda , Adolescente , Adulto , Estudos de Casos e Controles , Diástole , Feminino , Humanos , Masculino , Projetos Piloto , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Adulto Jovem
11.
J Am Heart Assoc ; 9(7): e014578, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32208831

RESUMO

Background Ischemic stroke in young individuals often remains cryptogenic. Some of these strokes likely originate from the heart, and atrial fibrosis might be one of the etiological mechanisms. In this pilot study, we investigated whether advanced echocardiography findings of the left atrium (LA) of young cryptogenic stroke patients differ from those of stroke-free controls. Methods and Results We recruited 30 cryptogenic ischemic stroke patients aged 18 to 49 years and 30 age- and sex-matched stroke-free controls among participants of the SECRETO (Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome) study (NCT01934725). We measured basic left ventricular parameters and detailed measures of the LA, including 4-dimensional volumetry, speckle tracking epsilon, strain rate, and LA appendix orifice variation. Data were compared as continuous parameters and by tertiles. Compared with controls, stroke patients had smaller LA reservoir volumes (10.2 [interquartile range, 5.4] versus 13.2 [5.4] mL; P=0.030) and smaller positive epsilon values (17.8 [8.5] versus 20.8 [10.1]; P=0.023). In the tertile analysis, stroke patients had significantly lower left atrial appendage orifice variation (3.88 [0.75] versus 4.35 [0.90] mm; P=0.043), lower LA cyclic volume change (9.2 [2.8] versus 12.8 [3.5] mL; P=0.023), and lower LA contraction peak strain rate (-1.8 [0.6] versus -2.3 [0.6]; P=0.021). We found no statistically significant differences in left ventricular measures. Conclusions This preliminary comparison suggests altered LA dynamics in young patients with cryptogenic ischemic stroke, and thus that LA wall pathology might contribute to these strokes. Our results await confirmation in a larger sample.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Doppler de Pulso , Cardiopatias/diagnóstico por imagem , AVC Isquêmico/etiologia , Adolescente , Adulto , Fatores Etários , Estudos de Casos e Controles , Feminino , Cardiopatias/complicações , Cardiopatias/fisiopatologia , Humanos , AVC Isquêmico/diagnóstico , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Adulto Jovem
12.
BMC Med Imaging ; 18(1): 43, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30442104

RESUMO

BACKGROUND: Left atrial volume is a prognostic factor in cardiac pathologies. We aimed to validate left atrial volume detection with 3D and 2D echocardiography (3DE and 2DE) by human cadaveric casts. 3DE facilitates measurement of atrial volume without geometrical assumptions or dependence on imaging angle in contrast to 2DE methods. METHODS: For method validation, six water-filled balloons were submerged in a 20-l water tank and their volumes were measured with 3DE. Seven human cadaveric left atrial casts were prepared of silicone and were transformed into ultrasound-permeable casts. Casts were imaged in the same setting, so that 3DE and 2DE of casts represented transthoracic apical view. Left ventricle analysis softwares GE 4D Auto LVQ and TomTec 4D LV-Function were used for 3DE volumetry. RESULTS: Balloon volumes ranged 37 to 255 ml (mean 126 ml). 3DE resulted in an excellent volumetric agreement with balloon volumes, absolute bias was - 3.7 ml (95% CI -5.9 to - 1.4). Atrial cast volumes were 38 to 94 ml (mean 56.6 ml). 3DE and 2DE volumes were excellently correlated with cast volumes (r = 0.96 to 0.99). Biases were for GE 4D LVQ -0.7 ml (95% CI -6.1 to 4.6), TomTec 4D LV-Function 3.3 ml (- 1.9 to 8.5) and 2DE 2.9 ml (- 4.0 to 9.9). 3DE resulted in lower limits of agreement and showed no volume-related bias in contrast to area-length method. CONCLUSIONS: We conclude that measurement of human cadaveric left atrial cast volumes by 3DE is in excellent agreement with true cast volumes.


Assuntos
Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Volume Sistólico , Cadáver , Ecocardiografia/métodos , Estudos de Viabilidade , Humanos , Modelos Biológicos , Reprodutibilidade dos Testes
13.
J Comput Assist Tomogr ; 42(5): 754-759, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30015798

RESUMO

OBJECTIVE: We aimed to validate the accuracy of imaging of left atrial and ventricular volumes using cardiac cadaveric silicone casts. METHODS: Left atrial (n = 14) and ventricular (n = 15) casts were imaged using 64-slice computed tomography (CT). Water displacement (WD) of cardiac casts was used as the gold standard for volume measurements. RESULTS: Compared with WD, CT resulted in slightly higher left atrial and ventricular volumes (54 ± 25 vs 56 ± 26 mL [P = 0.003] and 57 ± 47 vs 66 ± 47 mL [P = 0.0001]). Variability between left atrial and ventricular volumes by CT and WD was low (coefficients of variation [CVs], 4% [intraclass correlation coefficient {ICC}, 0.99] and 12% [ICC, 0.97]). Intraobserver variability of CT was low for both the left atrium and the left ventricle (CVs, 1% [ICC, 1.00] and 4% [ICC, 1.00]). CONCLUSIONS: Cardiac CT is both accurate and reproducible in assessment of left ventricular and atrial chamber volumes.


Assuntos
Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Cadáver , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Humanos , Técnicas In Vitro , Modelos Biológicos , Variações Dependentes do Observador , Tamanho do Órgão , Reprodutibilidade dos Testes
14.
J Cardiovasc Magn Reson ; 18(1): 33, 2016 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-27259862

RESUMO

BACKGROUND: Previous data suggest that mitral valve leaflets are elongated in hypertrophic cardiomyopathy (HCM), and mitral valve leaflet elongation may constitute a primary phenotypic expression of HCM. Our objective was to measure the length of mitral valve leaflets by cardiovascular magnetic resonance (CMR) in subjects with HCM caused by a Finnish founder mutation in the myosin-binding protein C gene (MYBPC3-Q1061X), carriers of the same mutation without left ventricular hypertrophy, as well as in unselected consecutive patients with HCM, and respective controls. METHODS: Anterior mitral valve leaflet (AML) and posterior mitral valve leaflet (PML) lengths were measured by CMR in 47 subjects with the Q1061X mutation in the gene encoding MYBPC3 and in 20 healthy relatives without the mutation. In addition, mitral valve leaflet lengths were measured by CMR in 80 consecutive non-genotyped patients with HCM in CMR and 71 age- and gender-matched healthy subjects. RESULTS: Of the subjects with the MYBPC-Q1016X mutation, 32 had left ventricular hypertrophy (LVH, LV maximal wall thickness ≥ 13 mm in CMR) and 15 had no hypertrophy. PML was longer in patients with the MYBPC3-Q1061X mutation and LVH than in controls of the MYBPC group (12.8 ± 2.8 vs 10.6 ± 1.9 mm, P = 0.013), but the difference between the groups was not statistically significant when PML was indexed for BSA (P = 0.066), or when PML length was adjusted for BSA, age, gender, LV mass and ejection fraction (P = 0.195). There was no significant difference in the PML length in mutation carriers without LVH and controls (11.1 ± 3.4 vs 10.6 ± 1.9, P = 0.52). We found no difference in AML lengths between the MYBPC mutation carriers with or without hypertrophy and controls. In 80 consecutive non-genotyped patients with HCM, there was no difference either in AML or PML lengths in subjects with HCM compared to respective control subjects. CONCLUSIONS: In subjects with HCM caused by the Q1061X mutation in the MYBPC3 gene, the posterior mitral valve leaflets may be elongated, but mitral valve elongation does not constitute primary phenotypic expression of the disease. Instead, elongated mitral valve leaflets seem to be associated with body size and left ventricular remodeling.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Imageamento por Ressonância Magnética , Valva Mitral/diagnóstico por imagem , Adolescente , Adulto , Tamanho Corporal , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/fisiopatologia , Proteínas de Transporte/genética , Estudos de Casos e Controles , Análise Mutacional de DNA , Feminino , Finlândia , Predisposição Genética para Doença , Humanos , Hipertrofia Ventricular Esquerda/genética , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Mutação , Fenótipo , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Adulto Jovem
15.
In Vivo ; 29(4): 487-91, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26130793

RESUMO

BACKGROUND/AIM: The left atrium (LA) is frequently imaged in cardiac computed tomographic (cCT) examinations. The LA volume can be accurately measured with three-dimensional (3D) volumetry but this method is time consuming and thus not routinely used in clinical practice. Accordingly, increased LA size may be overlooked although volume enlargement is associated with adverse cardiovascular events. We evaluated the accuracy of LA diameter measurement in cCT and in transthoracic echocardiography (TTE) in the diagnosis of LA enlargement using 3D cCT as the reference standard. PATIENTS AND METHODS: Altogether, 146 patients with suspected cardiogenic stroke underwent cCT and TTE. LA volume by cCT was determined for all patients. LA diameter was measured in both modalities. Furthermore, 40 healthy controls were analyzed in order to assess the cut-off values for normal LA volume. Diagnostic performance of cCT and conventional TTE diametrical measurements for detecting enlarged LA volume were analyzed and compared using Cohen's kappa (κ). RESULTS: In controls, the mean LA volume was 59.8±15.3 ml and the mean LA diameter was 30.4±5.0 mm by cCT. The mean value plus twice the standard deviation, which was considered the upper limit, for normal LA volume and diameter were 90.4 ml and 40.4 mm, respectively. Age- and gender-matched patients with stroke had statistically significantly (p<0.001) larger LA volumes (85.5±21.1 vs. 59.8±15.3 ml) and diameters (37.6±5.7 vs. 30.4±5.0 mm) than controls. LA diameter measurement by cCT was more reliable in detecting an LA volume enlargement than the corresponding measurement with TTE (κ=0.489 vs. 0.234; p=0.002). CONCLUSION: An enlarged LA diameter measured by cCT was more reliable than TTE at detecting enlarged LA volume.


Assuntos
Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Tomografia Computadorizada por Raios X , Idoso , Estudos de Casos e Controles , Ecocardiografia , Feminino , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Cardiopatias/patologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Clin Physiol Funct Imaging ; 30(2): 89-97, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19909300

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging (CMR) is a promising method for detecting coronary artery disease (CAD). The first reports of new diagnostic techniques indicated generally unrealistic diagnostic performance relying on retrospectively observed cut-off values of quantitative parameters. Although visual analysis of CMR is the most applicable method for clinical work, its diagnostic performance is not fully elucidated for study components such as wall motion, perfusion and late enhancement in patients with different severity of CAD. METHODS: A total of 30 subjects including 20 patients with CAD and 10 healthy volunteers were selected for the study. Of the patients, ten had stable CAD, five confirmed myocardial infarction (MI) without Q-waves in electrocardiogram (ECG) and five confirmed MI with Q-waves in ECG. All patients underwent coronary angiography and CMR for evaluating resting wall motion, rest and stress perfusion and late enhancement. RESULTS: Combining the data from the three CMR techniques, 12 out of 20 patients were correctly identified as having CAD, and all controls were found to be healthy. Sensitivity, specificity, accuracy, positive and negative predictive values were 60.0%, 100.0%, 73.0%, 100.0% and 55.6%, respectively. Of the CMR components, resting wall motion and late enhancement gave the most diagnostic yield. CONCLUSIONS: We conclude that evaluation of CAD is feasible in patients with different severity of CAD using visually analysed CMR, especially when available CMR methodologies are combined together.


Assuntos
Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Teste de Esforço , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Adulto , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Clin Physiol Funct Imaging ; 29(4): 229-40, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19302226

RESUMO

Cardiac magnetic resonance imaging (CMR) has rapidly gained acceptance as an accurate, reproducible and non-invasive imaging method for assessment of a wide range of cardiovascular diseases. However, CMR has not been used widely for diagnostic purposes in valvular heart disease (VHD). Unlike echocardiography it has no body habitus-related limitations and can thus be used to complement echocardiography. It is an especially good alternative for clinical follow-up in patients with VHD, as it allows accurate measurement of valvular dysfunction and related ventricular burden. Additionally, CMR is an ideal method for evaluating complex congenital heart disease and determining the significance of its components. It can also be used to study the physiological course of valvular dysfunction and response to therapeutic interventions. In this review, we present a basic introduction to CMR methodology, including its advantages and potential problems, and the physiology and quantification in VHD. We also discuss clinical applications of CMR in VHD. Furthermore, we describe how a CMR study statement should be structured in order to increase clinical use of this valuable methodology in cardiology.


Assuntos
Doenças das Valvas Cardíacas/diagnóstico , Valvas Cardíacas/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Humanos
18.
19.
Prim Care Respir J ; 17(4): 226-31, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18830519

RESUMO

AIMS: To assess the quality of primary care spirometry by visual inspection of the flow-volume expiratory curve and to study the quantity of clinical information provided on the spirometry report sheets. METHODS: Retrospective audit of 868 expiratory flow-volume curves referred to three pulmonary clinics assessed against five predefined quality criteria. Clinical information included on the spirometry report sheets was also collected. RESULTS: Quality was good in 78% of pre-bronchodilation curves and in 80% of post-bronchodilation curves. Obtaining a sharp PEF value and full vital capacity exhalation seemed to be the critical points of measurement. Inter-rater reliability of the curve assessment was mainly good. Data on where the spirometry took place, and comments on the use of respiratory medication and patient co-operation were often lacking. CONCLUSIONS: The quality of primary care spirometry was good. Adequate clinical information on the report sheets would further improve the quality of this diagnostic process.


Assuntos
Asma/diagnóstico , Asma/terapia , Atenção Primária à Saúde , Espirometria , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Asma/fisiopatologia , Feminino , Finlândia , Fluxo Expiratório Forçado/fisiologia , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Encaminhamento e Consulta , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
20.
J Magn Reson Imaging ; 28(3): 626-36, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18777544

RESUMO

PURPOSE: To validate a volumetric biventricular segmentation solution for multiaxis cardiac magnetic resonance (CMR) images. MATERIALS AND METHODS: The study population comprised 40 subjects. Biventricular end-diastolic and -systolic phases were segmented from both short-axis and horizontal long-axis or transaxial cine CMR images. Segmentation was based on fitting nonrigidly a 3D surface model to multiaxis CMR images. Five segmentations were performed: two manual segmentations by experts, automatic segmentation, and two segmentations where a user was allowed to correct errors in the automatic segmentation for 2 minutes and without time limits. Volumetry, distance measures, and visual grading were used to evaluate the quality of the segmentation. RESULTS: No difference was observed between automatic and manual segmentations in volumetric measures of the ventricles. The manual segmentation performed better for left-ventricular myocardial volume. The distance between surfaces as well as visual analysis did not show differences between automatic and manual segmentation for the endocardial border of the left ventricle but some corrections are needed for the right ventricle. CONCLUSION: Fully automatic segmentation produces good results in the assessment of left ventricular volume andendocardial border. Two minutes of user interaction are needed to obtain accurate results for the right ventricle.


Assuntos
Algoritmos , Ventrículos do Coração/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA