Resultados 1 - 16 de 16
Filtrar
1.
Arch Orthop Trauma Surg ; 143(9): 5957-5965, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36802237

RESUMO

INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Humanos , Feminino , Polietileno , Luxação do Quadril/cirurgia , Falha de Prótese , Desenho de Prótese , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Seguimentos
2.
Arch Orthop Trauma Surg ; 143(2): 1071-1080, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35113240

RESUMO

INTRODUCTION: The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. MATERIAL AND METHOD: In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70-89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> - 1) and low (< - 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. RESULTS: At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was - 0.04° (CI 95% - 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% - 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). CONCLUSION: The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Feminino , Idoso , Análise Radioestereométrica , Prótese de Quadril/efeitos adversos , Seguimentos , Estudos Prospectivos , Estudos de Coortes , Desenho de Prótese , Dor/etiologia , Falha de Prótese
3.
Arch Orthop Trauma Surg ; 143(9): 5919-5926, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36422666

RESUMO

BACKGROUND: Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. METHODS: RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arcoma T0 with ST-VI image plates and Profect CR-IR 363 reader to (2) AdoraRSA with CXDI-70C wireless DR detectors in a clinical uniplanar RSA set-up with a ± 20 degrees tube angulation and 35 cm × 43 cm detectors. Effective dose was calculated using dedicated software. Image quality was evaluated using calibration errors as calculated by the RSA software. RESULTS: The mean dose for hips was 0.14 (SD 0.04) mSv in the CR system and 0.05 (SD 0.02) mSv in the DR system. The mean dose for shoulders was 0.16 (SD 0.07) mSv in the CR system and 0.09 (SD 0.03) mSv in the DR system. Radiation dose was 64% (p < 0.001) and 43% (p = 0.03) lower in the DR system compared with the CR system for hip and shoulder RSA, respectively. Image quality was better for the DR system with 60-80% less calibration errors compared to the CR system. CONCLUSION: Owing to highly efficient detectors and added filtration at the x-ray tubes, the DR system considerably reduced radiation dose compared with the CR system without compromising image quality. Based on the findings in this study, we recommend replacing CR RSA systems with DR RSA systems. REGISTRATION: Patients were selected from clinical studies performed on the two systems and approved by the local ethics committee [20060165, M-20100112, M-20070082, M-20110224, and 20070258] and registered with ClinicalTrials.gov [NCT00408096, NCT01289834, NCT00913679, NCT02311179, and NCT00679120].


Assuntos
Artroplastia de Substituição , Prótese Articular , Humanos , Doses de Radiação , Intensificação de Imagem Radiográfica , Análise Radioestereométrica/métodos
4.
Acta Orthop ; 93: 906-913, 2022 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-36545926

RESUMO

BACKGROUND AND PURPOSE: Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up. PATIENTS AND METHODS: In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70-82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 30) fixation of Avantage DM THA with a highly-crosslinked vitamin-E PE liner. Cup migration and PE wear were measured with radiostereometric analysis (RSA), chromium and cobalt ions were measured in serum, and physical activity was measured with accelerometers. RESULTS: At 6-year follow-up, proximal cup migration was similar: 0.14 mm (95% CI 0.01-0.28) for cemented cups and 0.21 mm (0.02-0.39) for cementless cups. The PE wear rate from 1- to 6-year follow-up was also similar: 0.06 mm/year (0.04-0.09) for cemented cups and 0.07 mm/year (0.04-0.11) for cementless cups. Serum metal ion levels were undetectable or very low. Physical activity was mainly low intensity and did not correlate to PE wear rate or cup migration. CONCLUSION: Cemented and cementless DM cups with highly crosslinked vitamin-E infused liners have similar cup migration and PE wear when used for primary THA surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Idoso , Idoso de 80 Anos ou mais , Polietileno , Análise Radioestereométrica , Seguimentos , Cromo , Cobalto , Vitaminas , Desenho de Prótese , Falha de Prótese
5.
Musculoskelet Sci Pract ; 62: 102678, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36335851

RESUMO

BACKGROUND: Patients with unilateral hip osteoarthritis appear to have between-leg differences in leg extension power (LEP). The Nottingham Leg Extensor Power Rig provides reliable and valid results but requires sensitive equipment. It would be relevant to identify measures closely associated with this test. OBJECTIVE: (i) To investigate if LEP is lower in the affected leg compared to the non-affected leg. Furthermore, to investigate the associations between LEP and the measures: (ii) Functional performance, (iii) accelerometer-based measurement of physical activity and (iv) patient-reported outcome measures (PROM). DESIGN: Cross-sectional study including 60 patients (30 men, 30 women) with hip osteoarthritis scheduled for hip replacement. METHOD: The counter movement jump and 10-m sprint tests were used to determine functional performance, accelerometer-sensors were used to determine physical activity and the Copenhagen Hip and Groin Outcome Score (HAGOS) was used to determine PROM. RESULTS: (i) LEP in the affected leg corresponded to 79% [95% CI 74%; 85%] of the non-affected leg, (ii) LEP was positively associated with functional performance tests (ß 0.63 to 0.78, p < 0.05), (iii) positively associated although non-significantly with physical activity (ß 0.16 to 0.23, p > 0.05) and (iv) positively associated with the six HAGOS subscales (ß 0.25 to 0.54, p < 0.05). CONCLUSION: Functional performance tests may be used as feasible, inexpensive and fast ways to assess LEP in clinical settings. These results may suggest that interventions aimed at improving LEP can improve functional performance and PROM, but not physical activity. Future research is needed to confirm the causality of these cross-sectional findings. THE CLINICAL TRIAL REGISTRATION NUMBERS: Danish Data Protection Agency (1-16-02-640-14), ClinicalTrials.gov (NTC02301182) and approved by the Danish Biomedical Research Ethics Committee (1-10-72- 343-14) prior to data collection.


Assuntos
Osteoartrite do Quadril , Masculino , Humanos , Feminino , Estudos Transversais , Medidas de Resultados Relatados pelo Paciente , Desempenho Físico Funcional , Músculos
6.
Acta Orthop ; 93: 658-664, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35848733

RESUMO

BACKGROUND AND PURPOSE: BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. PATIENTS AND METHODS: In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55-75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. RESULTS: At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02-0.03). The 5-year anterior translation was 0.05 mm (CI -0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22-0.57) in the osteopenia group. INTERPRETATION: At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Durapatita , Seguimentos , Humanos , Pessoa de Meia-Idade , Polietileno , Porosidade , Desenho de Prótese , Falha de Prótese , Titânio
7.
Acta Orthop ; 93: 375-381, 2022 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35347340

RESUMO

BACKGROUND AND PURPOSE: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). PATIENTS AND METHODS: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. RESULTS: Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5-20), inclination 6° (2-12), and rotation 11° (5-48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12-46) and in liner/cup angle (larger articulation) was 6° (4-21). Static RSA showed changes in median liner anteversion from 7° (-12 to 23) postoperatively to 10° (-3 to 16) at 1-year follow-up and inclination from 42° (35-66) postoperatively to 59° (46-80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). INTERPRETATION: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Humanos , Polietileno , Análise Radioestereométrica , Amplitude de Movimento Articular
8.
J Exp Orthop ; 9(1): 4, 2022 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-34985680

RESUMO

PURPOSE: Dynamic radiostereometric analysis (dRSA) enables precise non-invasive three-dimensional motion-tracking of bones for assessment of joint kinematics. Hereby, the biomechanical effects of arthroscopic osteochondroplasty of the hip (ACH) can be evaluated in patients with femoroacetabular impingement (FAI). The aim was to investigate the pre- and postoperative range of motion (ROM) and the CT bone volume removed (BV) after ACH. We hypothesize increase in ROM 1 year after surgery. METHODS: Thirteen patients (6 female) with symptomatic FAI were included prospectively. The patient's hips were CT-scanned and CT-bone models were created. Preoperative dRSA recordings were acquired during passive flexion to 90°, adduction, and internal rotation (FADIR). ACH was performed, CT and dRSA were repeated 3 months and 1 year postoperatively. Hip joint kinematics before, and 3 months and 1 year after ACH were compared pairwise. The bone volume removal was quantified and compared to change in ROM. RESULTS: Mean hip internal rotation, adduction and flexion were all unchanged after ACH at 1-year follow-up (p > 0.84). HAGOS scores revealed improvement of quality of life (QOL) from 32 to 60 (p = 0.02). The BV was between 406 and 1783 mm3 and did not correlate to post-operative ROM. CONCLUSIONS: ACH surgery in FAI patients had no impact of ROM at 1-year follow-up. QOL improved significantly. This indicates that the positive clinical effects reported after ACH might be a result of reduced labral stress and cartilage pressure during end-range motion rather than increased ROM. LEVEL OF EVIDENCE: Therapeutic prospective cohort study, level II.

9.
Eur Radiol Exp ; 5(1): 55, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34907467

RESUMO

BACKGROUND: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. METHODS: The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. RESULTS: The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. CONCLUSION: Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. TRIAL REGISTRATION: ClinicalTrials.gov [ NCT02301182 ], 25 October 2015.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica
10.
J Hand Surg Eur Vol ; 45(9): 923-930, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32594823

RESUMO

Distal radioulnar joint instability is difficult to grade by clinical examination and interobserver reliability is low. This study used a new and precise radiostereometry method for measurement of distal radioulnar joint translation. Eight human donor arms were positioned in a custom-made fixture and a standardized piano key test was done with pressure on the ulnar head. Examination was done before and after dividing the styloid and foveal insertions of the triangular fibrocartilage complex. In the intact wrists, the piano key test induced a mean 1.36 mm translation of the ulnar head, which increased statistically significantly to 1.96 mm after a lesion of the styloid ligament insertion and to 2.3 mm after combined lesions of the styloid and foveal ligament insertions. This experimental cadaver study demonstrates a radiological method for precise quantification of distal radioulnar joint stability after different grades of triangular fibrocartilage complex injury.


Assuntos
Instabilidade Articular , Fibrocartilagem Triangular , Humanos , Instabilidade Articular/diagnóstico por imagem , Análise Radioestereométrica , Reprodutibilidade dos Testes , Ulna/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem
11.
Acta Orthop ; 91(1): 26-32, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31698977

RESUMO

Background and purpose - BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM.Patients and methods - In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55-75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs.Results - At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02-0.20) was higher than in the P group (0.25 mm, CI 0.15-0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14-20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04).Interpretation - Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.


Assuntos
Artroplastia de Quadril , Materiais Revestidos Biocompatíveis , Prótese de Quadril , Osseointegração , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Idoso , Materiais Biocompatíveis , Durapatita , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Radioestereométrica , Método Simples-Cego
12.
Artigo em Inglês | MEDLINE | ID: mdl-30984557

RESUMO

BACKGROUND: Vertical jump highs are used to quantify performance in the lower extremities. The aim of this study was to validate a wearable inertial measurement unit (IMU) for purpose of estimating countermovement jump height using the following methods: numerical double integration (NDI), takeoff velocity (TOV) and flight-time (FT). METHODS: Fifteen students each performed three jumps in two different sessions, four weeks apart. Jump-heights calculated from motion capture and force plate were used as gold standard for global IMU position and center of mass (CoM) displacement, respectively. RESULTS: The NDI method showed higher estimates for global position (1.39 cm, p = 0.025), and for CoM displacement (4.20 cm, p < 0.001). Narrow limits of agreements (LoA) were found (<4.8 cm). Further, a low tolerance level of determining equivalence (delta) between the two sessions regarding both global and CoM displacement (±2.80 and ±â€¯2.90 cm) suggesting reasonable test-retest reliability.Similar bias was found for TOV and FT (p < 0.015) and wide LoAs were found for global position and for CoM displacement (TOV: ±7.05 and ±â€¯9.36 cm, AT: ±9.27 and ±â€¯8.49 cm). Further, high delta between the two sessions (TOV: ±3.50 cm, FT ±4.00 cm) showed poor test-retest reliability. CONCLUSION: Estimation of countermovement jump height using an IMU leads to the most accurate measurements applying the NDI-method. Countermovement jump estimated with an IMU can reliably evaluate functional performance in the lower extremities in young or in sports active patients after surgery or after rehabilitation. Countermovement jump with an IMU allows performing the test without a force plate and thus serves as an objective outcome measure in clinical practice.

13.
Orthop J Sports Med ; 6(8): 2325967118789699, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30116763

RESUMO

BACKGROUND: An anterior cruciate ligament (ACL) rupture often occurs during rotational trauma to the knee and may be associated with damage to extracapsular knee rotation-stabilizing structures such as the anterolateral ligament (ALL). PURPOSE: To investigate ex vivo knee laxity in 6 degrees of freedom with and without ALL reconstruction as a supplement to ACL reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: Cadaveric knees (N = 8) were analyzed using dynamic radiostereometry during a controlled pivotlike dynamic movement simulated by motorized knee flexion (0° to 60°) with 4-N·m internal rotation torque. We tested the cadaveric specimens in 5 successive ligament situations: intact, ACL lesion, ACL + ALL lesion, ACL reconstruction, and ACL + ALL reconstruction. Anatomic single-bundle reconstruction methods were used for both the ACL and the ALL, with a bone-tendon quadriceps autograft and gracilis tendon autograft, respectively. Three-dimensional kinematics and articular surface interactions were used to determine knee laxity. RESULTS: For the entire knee flexion motion, an ACL + ALL lesion increased the mean knee laxity (P < .005) for internal rotation (2.54°), anterior translation (1.68 mm), and varus rotation (0.53°). Augmented ALL reconstruction reduced knee laxity for anterior translation (P = .003) and varus rotation (P = .047) compared with ACL + ALL-deficient knees. Knees with ACL + ALL lesions had more internal rotation (P < .001) and anterior translation (P < .045) at knee flexion angles below 40° and 30°, respectively, compared with healthy knees. Combined ACL + ALL reconstruction did not completely restore native kinematics/laxity at flexion angles below 10° for anterior translation and below 20° for internal rotation (P < .035). ACL + ALL reconstruction was not found to overconstrain the knee joint. CONCLUSION: Augmented ALL reconstruction with ACL reconstruction in a cadaveric setting reduces internal rotation, varus rotation, and anterior translation knee laxity similar to knee kinematics with intact ligaments, except at knee flexion angles between 0° and 20°. CLINICAL RELEVANCE: Patients with ACL injuries can potentially achieve better results with augmented ALL reconstruction along with ACL reconstruction than with stand-alone ACL reconstruction. Furthermore, dynamic radiostereometry provides the opportunity to examine clinical patients and compare the recontructed knee with the contralateral knee in 6 degrees of freedom.

14.
J Exp Orthop ; 4(1): 20, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28585023

RESUMO

BACKGROUND: Dynamic RSA (dRSA) enables non-invasive 3D motion-tracking of bones and may be used to evaluate in-vivo hip joint kinematics including hip pathomechanics such as femoroacetabular impingement (FAI) and the biomechanical effects of arthroscopic cheilectomy and -rim trimming (ACH). The study aim was to evaluate the kinematic changes in the hip joint after ACH. METHODS: Seven non-FAI affected human cadaveric hips were CT-scanned and CT-bone models were created. dRSA recordings of the hip joints were acquired at five frames/s during passive flexion, adduction to stop, and internal rotation to stop (FADIR). ACH was performed and dRSA was repeated. dRSA images were analyzed using model-based RSA. Hip joint kinematics before and after ACH were compared pairwise. The volume of removed bone was quantified and compared to the postoperative range of motion (ROM). RESULTS: Mean hip internal rotation increased from 19.1 to 21.9° (p = 0.04, Δ2.8°, SD 2.7) after ACH surgery. Mean adduction of 3.9° before and 2.7° after ACH surgery was unchanged (p = 0.48, Δ-1.2°; SD 4.3). Mean flexion angles during dRSA tests were 82.4° before and 80.8° after ACH surgery, which were similar (p = 0.18, Δ-1.6°, SD = 2.7). No correlation between volume of removed bone and ROM was observed. CONCLUSIONS: A small increase in internal rotation, but not in adduction, was observed after arthroscopic cheilectomy and -rim trimming in cadaver hips. The hip flexion angle of the FADIR test was reproducible. dRSA kinematic analysis is a new and clinically applicable method with good potential to evaluate hip joint kinematics and to test FAI pathomechanics and other surgical corrections of the hip.

15.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1125-1131, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28314889

RESUMO

PURPOSE: Little is known about the anterolateral ligament's (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. METHODS: Eight human donor legs were positioned and stereoradiographically recorded at 0°, 30° and 60° of knee flexion using a motorised fixture, while an internally rotating force of 4 Nm was applied to the foot. Anterior-posterior and rotational laxity were investigated for knees with intact ligaments and compared with those observed after successive ACL and ALL resection and reconstruction. RESULTS: After cutting the ALL in ACL-deficient knees, the internal rotation was increased in all three knee flexion angles, 0° (p = 0.04), 30° (p = 0.03) and 60° (p < 0.01) by 1.0°, 1.6° and 2.5°, respectively. However, no decrease in laxity was found after reconstructing the ALL in ACL-reconstructed knees. CONCLUSIONS: The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Ligamentos Articulares/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Análise Radioestereométrica , Rotação
16.
Arch Orthop Trauma Surg ; 135(9): 1217-26, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26141537

RESUMO

INTRODUCTION: During movement tasks, patients with medial compartment knee osteoarthritis use compensatory strategies to minimise the joint load of the affected leg. Movement strategies of the knees and trunk have been investigated, but less is known about movement strategies of the pelvis during advancing functional tasks, and how these strategies are associated with leg extension power. The aim of the study was to investigate pelvic movement strategies and leg extension power in patients with end-stage medial compartment knee osteoarthritis compared with controls. MATERIALS AND METHODS: 57 patients (mean age 65.6 years) scheduled for medial uni-compartmental knee arthroplasty, and 29 age and gender matched controls were included in this cross-sectional study. Leg extension power was tested with the Nottingham Leg Extension Power-Rig. Pelvic range of motion was derived from an inertia-based measurement unit placed over the sacrum bone during walking, stair climbing and stepping. RESULTS: Patients had lower leg extension power than controls (20-39 %, P < 0.01) and used greater pelvic range of motion during stair and step ascending and descending (P ≤ 0.03, except for pelvic range of motion in the frontal plane during ascending, P > 0.06). Furthermore, an inverse association (coefficient: -0.03 to -0.04; R (2) = 13-22 %) between leg extension power and pelvic range of motion during stair and step descending was found in the patients. CONCLUSIONS: Compared to controls, patients with medial compartment knee osteoarthritis use greater pelvic movements during advanced functional performance tests, particularly when these involve descending tasks. Further studies should investigate if it is possible to alter these movement strategies by an intervention aimed at increasing strength and power for the patients.


Assuntos
Extremidade Inferior/fisiologia , Força Muscular/fisiologia , Osteoartrite do Joelho/fisiopatologia , Pelve/fisiologia , Amplitude de Movimento Articular/fisiologia , Idoso , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Movimento/fisiologia , Caminhada/fisiologia