Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Cancers (Basel) ; 15(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37296958

RESUMO

Conversely to most tumour types, magnetic resonance imaging (MRI) was rarely used for eye tumours. As recent technical advances have increased ocular MRI's diagnostic value, various clinical applications have been proposed. This systematic review provides an overview of the current status of MRI in the clinical care of uveal melanoma (UM) patients, the most common eye tumour in adults. In total, 158 articles were included. Two- and three-dimensional anatomical scans and functional scans, which assess the tumour micro-biology, can be obtained in routine clinical setting. The radiological characteristics of the most common intra-ocular masses have been described extensively, enabling MRI to contribute to diagnoses. Additionally, MRI's ability to non-invasively probe the tissue's biological properties enables early detection of therapy response and potentially differentiates between high- and low-risk UM. MRI-based tumour dimensions are generally in agreement with conventional ultrasound (median absolute difference 0.5 mm), but MRI is considered more accurate in a subgroup of anteriorly located tumours. Although multiple studies propose that MRI's 3D tumour visualisation can improve therapy planning, an evaluation of its clinical benefit is lacking. In conclusion, MRI is a complementary imaging modality for UM of which the clinical benefit has been shown by multiple studies.

2.
Neuroradiology ; 65(8): 1271-1285, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37249621

RESUMO

PURPOSE: MRI is increasingly used in the diagnosis and therapy planning of uveal melanoma (UM). In this prospective cohort study, we assessed the radiological characteristics, in terms of anatomical and functional imaging, of UM after ruthenium-106 plaque brachytherapy or proton beam therapy (PBT) and compared them to conventional ultrasound. METHODS: Twenty-six UM patients were evaluated before and 3, 6 and 12 months after brachytherapy (n = 13) or PBT (n = 13). Tumour prominences were compared between ultrasound and MRI. On diffusion-weighted imaging, the apparent diffusion value (ADC), and on perfusion-weighted imaging (PWI), the time-intensity curves (TIC), relative peak intensity and outflow percentages were determined. Values were compared between treatments and with baseline. RESULTS: Pre-treatment prominences were comparable between MRI and ultrasound (mean absolute difference 0.51 mm, p = 0.46), but larger differences were observed post-treatment (e.g. 3 months: 0.9 mm (p = 0.02)). Pre-treatment PWI metrics were comparable between treatment groups. After treatment, brachytherapy patients showed favourable changes on PWI (e.g. 67% outflow reduction at 3 months, p < 0.01). After PBT, significant perfusion changes were observed at a later timepoint (e.g. 38% outflow reduction at 6 months, p = 0.01). No consistent ADC changes were observed after either treatment, e.g. a 0.11 × 10-3mm2/s increase 12 months after treatment (p = 0.15). CONCLUSION: MR-based follow-up is valuable for PBT-treated patients as favourable perfusion changes, including a reduction in outflow, can be detected before a reduction in size is apparent on ultrasound. For brachytherapy, a follow-up MRI is of less value as already 3 months post-treatment a significant size reduction can be measured on ultrasound.


Assuntos
Braquiterapia , Terapia com Prótons , Neoplasias Uveais , Humanos , Seguimentos , Estudos Prospectivos , Terapia com Prótons/métodos , Braquiterapia/métodos , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/radioterapia , Imageamento por Ressonância Magnética , Estudos Retrospectivos
3.
Adv Radiat Oncol ; 8(3): 101149, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691449

RESUMO

Purpose: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. Methods and Materials: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. Results: The average GTV was significantly larger on T1gd (0.57cm3) compared with T2 (0.51cm3, P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. Conclusions: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.

4.
Ophthalmol Retina ; 7(2): 178-188, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35840053

RESUMO

OBJECTIVE: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to the recent advances in magnetic resonance imaging (MRI) of uveal melanoma (UM), it is possible to acquire high-resolution 3-dimensional images of the eye, providing the opportunity to incorporate MRI in ocular PT planning. In this study, we described how these measurements can be obtained using MRI, compared the MRI-based measurements with conventional ophthalmic measurements, and identified potential pitfalls for both modalities. DESIGN: Cross-sectional study. SUBJECTS: Data from 23 consecutive patients with UM treated with PT were retrospectively evaluated. METHODS: Magnetic resonance imaging-based measurements of axial length, tumor height and basal diameter, and marker-tumor distances were compared with the conventional ophthalmic measurements, and discrepancies were evaluated in a multidisciplinary setting. MAIN OUTCOME MEASURES: Tumor prominence and basal diameters on MRI and ultrasound, axial length on MRI and biometry, tumor-marker distances on MRI and measured intraoperatively. RESULTS: The mean absolute differences of the tumor height and basal diameter measurements between ultrasound and MRI were 0.57 mm and 1.44 mm, respectively. Larger absolute differences in height and basal diameter were observed when the full tumor extent was not visible on ultrasound (0.92 mm and 1.67 mm, respectively) compared with when the full tumor extent was visible (0.44 mm and 1.15 mm, respectively). When the full tumor was not visible on ultrasound, MRI was considered more reliable. Tumor-marker distances measured using MRI and intraoperative techniques differed < 1 mm in 55% of the markers. For anteriorly located and mushroom-shaped tumors (25% of the markers), MRI provided more accurate measurements. In flat UM (15% of the markers), however, it was difficult to delineate the tumor on MRI. The mean absolute difference in axial length between optical biometry and MRI was 0.50 mm. The presence of the tumor was found to influence optical biometry in 15 of 22 patients; the remaining patients showed a better agreement (0.30 mm). Magnetic resonance imaging-based biometry was considered more reliable in patients with UM. CONCLUSIONS: Magnetic resonance imaging allowed for the 3-dimensional assessment of the tumor and surrounding tissue. In specific patients, it provided a more reliable measurement of axial length, tumor dimensions, and marker-tumor distances and could contribute to a more accurate treatment planning. Nevertheless, a combined evaluation remains advised, especially for flat UM.


Assuntos
Terapia com Prótons , Humanos , Estudos Transversais , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
5.
Phys Imaging Radiat Oncol ; 24: 102-110, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36386446

RESUMO

Background and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods: Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results: Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions: The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.

6.
Rheumatology (Oxford) ; 61(6): 2663-2671, 2022 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-34730801

RESUMO

OBJECTIVES: Advanced white matter hyperintensity (WMH) markers on brain MRI may help reveal underlying mechanisms and aid in the diagnosis of different phenotypes of SLE patients experiencing neuropsychiatric (NP) manifestations. METHODS: In this prospective cohort study, we included a clinically well-defined cohort of 155 patients consisting of 38 patients with NPSLE (26 inflammatory and 12 ischaemic phenotype) and 117 non-NPSLE patients. Differences in 3 T MRI WMH markers (volume, type and shape) were compared between patients with NPSLE and non-NPSLE and between patients with inflammatory and ischaemic NPSLE by linear and logistic regression analyses corrected for age, sex and intracranial volume. RESULTS: Compared with non-NPSLE [92% female; mean age 42 (13) years], patients with NPSLE [87% female; mean age 40 (14) years] showed a higher total WMH volume [B (95%-CI)]: 0.46 (0.0 7 ↔ 0.86); P = 0.021], a higher periventricular/confluent WMH volume [0.46 (0.0 6 ↔ 0.86); P = 0.024], a higher occurrence of periventricular with deep WMH type [0.32 (0.1 3 ↔ 0.77); P = 0.011], a higher number of deep WMH lesions [3.06 (1.2 1 ↔ 4.90); P = 0.001] and a more complex WMH shape [convexity: ‒0.07 (‒0.12 ↔ ‒0.02); P = 0.011, concavity index: 0.05 (0.0 1 ↔ 0.08); P = 0.007]. WMH shape was more complex in inflammatory NPSLE patients [89% female; mean age 39 (15) years] compared with patients with the ischaemic phenotype [83% female; mean age 41 (11) years] [concavity index: 0.08 (0.0 1 ↔ 0.15); P = 0.034]. CONCLUSION: We demonstrated that patients with NPSLE showed a higher periventricular/confluent WMH volume and more complex shape of WMH compared with non-NPSLE patients. This finding was particularly significant in inflammatory NPLSE patients, suggesting different or more severe underlying pathophysiological abnormalities.


Assuntos
Lúpus Eritematoso Sistêmico , Vasculite Associada ao Lúpus do Sistema Nervoso Central , Substância Branca , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Feminino , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Lúpus Eritematoso Sistêmico/patologia , Vasculite Associada ao Lúpus do Sistema Nervoso Central/patologia , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Substância Branca/diagnóstico por imagem
7.
J Magn Reson Imaging ; 55(5): 1504-1515, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34652049

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is increasingly being used in the diagnosis and treatment planning of uveal melanoma (UM), the most common primary intraocular tumor. Initially, 7 T MRI was primarily used, but more recently these techniques have been translated to 3 T, as it is more commonly available. PURPOSE: Compare the diagnostic performance of 3 T and 7 T MRI of UM. STUDY TYPE: Prospective. POPULATION: Twenty-seven UM patients (19% female). FIELD STRENGTH/SEQUENCE: 3 T: T1- and T2-weighted three-dimensional (3D) spin echo (SE) and multi-slice (MS) SE, 7 T: T1-weighted 3D gradient echo (GE), T2-weighted 3D SE and MS SE, 3 T and 7 T GE dynamic contrast-enhanced. T1 weighted images: acquired before and after Gadolinium (Gd) administration. ASSESSMENT: For all sequences, scan and diagnostic quality was quantified using a 5-point Likert scale. Signal intensities on T1 and T2 relative to choroid and eye muscle respectively were assessed as well as the tumor prominence. Finally, the perfusion time-intensity curves (TICs) were classified as plateau, progressive, or wash-out. STATISTICAL TESTS: Image quality scores were compared between both field strengths using Wilcoxon signed-rank and McNemar tests. Paired t-tests and Bland-Altman were used for comparing tumor prominences. P < 0.05 was considered statistically significant. RESULTS: Image quality was comparable between 3 T and 7 T, for 3DT1, 3DT2, 3DT1Gd (P = 0.86; P = 0.34; P = 0.78, respectively) and measuring tumor dimensions (P = 0.40). 2DT1 and 2DT2 image quality were rated better on 3 T compared to 7 T. Most UM had the same relative signal intensities at 3 T and 7 T on T1 (17/21) and T2 (13/17), and 16/18 diagnostic TICs received the same classification. Tumor prominence measurements were similar between field strengths (95% confidence interval: -0.37 mm to 0.03 mm, P = 0.097). DATA CONCLUSION: Diagnostic performance of the evaluated 3 T protocol proved to be as capable as 7 T, with the addition of 3 T being superior in assessing tumor growth into nearby anatomical structures compared to 7 T. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 3.


Assuntos
Melanoma , Neoplasias Uveais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Melanoma/diagnóstico por imagem , Estudos Prospectivos , Neoplasias Uveais/diagnóstico por imagem
8.
MAGMA ; 35(2): 311-323, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34643852

RESUMO

OBJECTIVE: Dynamic contrast enhanced (DCE)-MRI is currently not generally used for intraocular masses as lesions are small, have an inhomogeneous T1 and the eye is prone to motion. The aim of this paper is to address these eye-specific challenges, enabling accurate ocular DCE-MRI. MATERIALS & METHODS: DCE-MRI of 19 uveal melanoma (UM) patients was acquired using a fat-suppressed 3D spoiled gradient echo sequence with TWIST (time-resolved angiography with stochastic trajectories sequence). The analysis consisted of a two-step registration method to correct for both head and eye motion. A T1 map was calculated to convert signal intensities to concentrations. Subsequently, the Tofts model was fitted voxel wise to obtain Ktrans and ve. RESULTS: Registration significantly improved the concentration curve quality (p < 0.001). The T1 of melanotic lesions was significantly lower than amelanotic lesions (888 ms vs 1350 ms, p = 0.03). The average achieved B1+ in the lesions was 91%. The average Ktrans was 0.46 min-1 (range 0.13-1.0) and the average ve was 0.22 (range 0.10-0.51). CONCLUSION: Using this eye-specific analysis, DCE of intraocular masses is possible which might aid in the diagnosis, prognosis and follow-up of UM.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Angiografia , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Prognóstico
9.
Neuroradiology ; 64(1): 171-184, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34718831

RESUMO

PURPOSE: To evaluate the magnetic resonance imaging (MRI) characteristics of uveal melanoma (UM), to compare them with fundoscopy and ultrasound (US), and to validate them with histopathology. METHODS: MR images from 42 UM were compared with US and fundoscopy, and on 14 enucleated cases with histopathology. RESULTS: A significant relationship between the signal intensity on T1 and pigmentation on histopathology was found (p=0.024). T1 hyperintense UM were always moderately or strongly pigmented on histopathology, while T1-hypointense UM were either pigmented or non-pigmented. Mean apparent diffusion coefficient (ADC) of the UM was 1.16 ± 0.26 × 10-3 mm2/s. Two-thirds of the UM had a wash-out and the remaining a plateau perfusion time-intensity curve (TIC). MRI was limited in evaluating the basal diameter of flat tumors. US tends to show larger tumor prominence (0.5mm larger, p=0.008) and largest basal diameter (1.4mm larger, p<0.001). MRI was good in diagnosing ciliary body involvement, extrascleral extension, and optic nerve invasion, but limited on identifying scleral invasion. An increase of tumor prominence was associated with lower ADC values (p=0.030) and favored a wash-out TIC (p=0.028). An increase of tumor ADC correlated with a plateau TIC (p=0.011). CONCLUSIONS: The anatomical and functional MRI characteristics of UM were comprehensively assessed. Knowing the MRI characteristics of UM is important in order to confirm the diagnosis and to differentiate UM from other intra-ocular lesions and because it has implications for treatment planning. MRI is a good technique to evaluate UM, being only limited in case of flat tumors or on identifying scleral invasion.


Assuntos
Melanoma , Neoplasias Uveais , Humanos , Imageamento por Ressonância Magnética , Melanoma/diagnóstico por imagem , Ultrassonografia , Neoplasias Uveais/diagnóstico por imagem
10.
Adv Radiat Oncol ; 6(6): 100697, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660938

RESUMO

PURPOSE: The optimal treatment strategy for uveal melanoma (UM) relies on many factors, the most important being tumor size and location. Building on recent developments in high-resolution 3D ocular magnetic resonance imaging (MRI), we developed an automatic image-processing framework to create patient-specific eye models and to subsequently determine the full 3D tumor shape and size automatically. METHODS AND MATERIALS: From 15 patients with UM, 3D inversion-recovery gradient-echo (T1-weighted) and 3D fat-suppressed spin-echo (T2-weighted) images were acquired with a 7T MRI scanner. First, the sclera and cornea were segmented from the T2-weighted image by mesh-fitting. The T1- and T2-weighted images were then coregistered. From the registered T1-weighted image, the lens, vitreous body, retinal detachment, and tumor were segmented. Fuzzy C-means clustering was used to differentiate the tumor from retinal detachments. The tumor model was verified and (if needed) edited by an ophthalmic MRI specialist. Subsequently, the prominence and largest basal diameter of the tumor were measured automatically based on the verified contours. These results were compared with manual assessments on the original images and with ultrasound measurements to show the errors in manual analysis. RESULTS: The framework successfully created an eye model fully automatically in 12 cases. In these cases, a Dice similarity coefficient (mean surface distance) of 97.7%±0.84% (0.17±0.11 mm) was achieved for the sclera, 96.8%±1.05% (0.20±0.06 mm) for the vitreous body, 91.6%±4.83% (0.15±0.06 mm) for the lens, and 86.0%±7.4% (0.35±0.27 mm) for the tumor. The manual assessments deviated, on average, 0.39±0.31 mm in prominence and 1.7±1.22 mm in basal diameter from the automatic measurements. CONCLUSIONS: The described framework combined information from T1- and T2-weighted images to accurately determine tumor boundaries in 3D. The proposed process may have a direct effect on clinical workflow, as it enables an accurate 3D assessment of tumor dimensions, which directly influences therapy selection.

11.
Cancers (Basel) ; 12(3)2020 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-32178233

RESUMO

T-staging of most eyelid malignancies includes the assessment of the integrity of the tarsal plate and orbital septum, which are not clinically accessible. Given the contribution of MRI in the characterization of orbital tumors and establishing their relations to nearby structures, we assessed its value in identifying different eyelid structures in 38 normal eyelids and evaluating tumor extension in three cases of eyelid tumors. As not all patients can receive an MRI, we evaluated those same structures on CT and compared both results. All eyelid structures were identified on MRI and CT, except for the conjunctiva on both techniques and for the tarsal muscles on CT. Histopathology confirmed the MRI findings of orbital septum invasion in one patient, and the MRI findings of intact tarsus and orbital septum in another patient. Histopathology could not confirm or exclude tarsal invasion seen on MRI on two patients. Although imaging the eyelid is challenging, the identification of most eyelid structures is possible with MRI and, to a lesser extent, with CT and can, therefore, have an important contribution to the T-staging of eyelid tumors, which may improve treatment planning and outcome.

12.
Phys Imaging Radiat Oncol ; 16: 33-36, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458341

RESUMO

Proton beam therapy (PBT) for uveal melanoma (UM) is performed in sitting position, while the acquisition of the Magnetic resonance (MR)-images for treatment planning is performed in supine position. We assessed the effect of this difference in position on the eye- and tumour- shape. Seven subjects and six UM-patients were scanned in supine and a seating mimicking position. The distances between the tumour/sclera in both positions were calculated. The median distance between both positions was 0.1 mm. Change in gravity direction produced no substantial changes in sclera and tumour shape, indicating that supinely acquired MR-images can be used to plan ocular-PBT.

13.
J Cereb Blood Flow Metab ; 40(2): 354-364, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-30547694

RESUMO

Neurodegenerative and neurovascular diseases lead to heterogeneous brain abnormalities. A combined analysis of these abnormalities by phenotypes of the brain might give a more accurate representation of the underlying aetiology. We aimed to identify different MRI phenotypes of the brain and assessed the risk of future stroke and mortality within these subgroups. In 1003 patients (59 ± 10 years) from the Second Manifestations of ARTerial disease-Magnetic Resonance (SMART-MR) study, different quantitative 1.5T brain MRI markers were used in a hierarchical clustering analysis to identify 11 distinct subgroups with a different distribution in brain MRI markers and cardiovascular risk factors, and a different risk of stroke (Cox regression: from no increased risk compared to the reference group with relatively few brain abnormalities to HR = 10.34; 95% CI 3.80↔28.12 for the multi-burden subgroup) and mortality (from no increased risk compared to the reference group to HR = 4.00; 95% CI 2.50↔6.40 for the multi-burden subgroup). In conclusion, within a group of patients with manifest arterial disease, we showed that different MRI phenotypes of the brain can be identified and that these were associated with different risks of future stroke and mortality. These MRI phenotypes can possibly classify individual patients and assess their risk of future stroke and mortality.


Assuntos
Encéfalo , Infarto Cerebral , Imageamento por Ressonância Magnética , Acidente Vascular Cerebral , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/etiologia , Infarto Cerebral/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade
14.
Sci Rep ; 9(1): 11343, 2019 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-31383903

RESUMO

Frailty is a common syndrome in older individuals that is associated with poor cognitive outcome. The underlying brain correlates of frailty are unclear. The aim of this study was to investigate the association between frailty and MRI features of cerebral small vessel disease in a group of non-demented older individuals. We included 170 participants who were classified as frail (n = 30), pre-frail (n = 85) or non-frail (n = 55). The association of frailty and white matter hyperintensity volume and shape features, lacunar infarcts and cerebral perfusion was investigated by regression analyses adjusted for age and sex. Frail and pre-frail participants were older, more often female and showed higher white matter hyperintensity volume (0.69 [95%-CI 0.08 to 1.31], p = 0.03 respectively 0.43 [95%-CI: 0.04 to 0.82], p = 0.03) compared to non-frail participants. Frail participants showed a non-significant trend, and pre-frail participants showed a more complex shape of white matter hyperintensities (concavity index: 0.04 [95%-CI: 0.03 to 0.08], p = 0.03; fractal dimensions: 0.07 [95%-CI: 0.00 to 0.15], p = 0.05) compared to non-frail participants. No between group differences were found in gray matter perfusion or in the presence of lacunar infarcts. In conclusion, increased white matter hyperintensity volume and a more complex white matter hyperintensity shape may be structural brain correlates of the frailty phenotype.


Assuntos
Doenças de Pequenos Vasos Cerebrais/complicações , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Fragilidade/complicações , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Doenças de Pequenos Vasos Cerebrais/patologia , Feminino , Idoso Fragilizado , Fragilidade/diagnóstico por imagem , Fragilidade/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Substância Branca/irrigação sanguínea , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
15.
Cancers (Basel) ; 11(3)2019 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-30884881

RESUMO

Uveal Melanoma (UM) is the most common primary malignant ocular tumor. The high soft tissue contrast and spatial resolution, and the possibility of generating 3D volumetric and functional images, make Magnetic Resonance Imaging (MRI) a valuable diagnostic imaging technique in UM. Current clinical MRI protocols, however, are not optimized for UM and therefore lack the quality for accurate assessments. We therefore developed a dedicated protocol at a 3 Tesla MRI, using an eye coil, consisting of multi-slice 2D sequences, different isotropic sequences and diffusion and perfusion-weighted images. This protocol was prospectively evaluated in 9 uveal melanoma patients. The multi-slice 2D sequences had the highest in-plane resolution, being the most suited for lesion characterization and local extension evaluation. The isotropic 3D Turbo-Spin Echo (TSE) sequences were the most suitable for accurate geometric measurements of the tumor and are therefore important for therapy planning. Diffusion and perfusion-weighted images aid in differentiating benign from malignant lesions and provide quantitative measures on tumor hemodynamics and cellularity, which have been reported to be effective in predicting and assessing treatment outcome. Overall, this dedicated MRI protocol provides high-quality imaging of UM, which can be used to improve its diagnosis, treatment planning, and follow-up.

16.
Melanoma Res ; 29(6): 655-659, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30664105

RESUMO

Uveal melanoma (UM), the most common primary intraocular tumour, is often complicated by exudative retinal detachment (RD). Sometimes, this exudative RD is mistaken for a rhegmatogenous detachment and is subsequently treated with vitrectomy with silicone oil (SiOil) tamponade. As SiOil prevents ultrasound imaging, the diagnosis, treatment planning and/or follow-up of UM underlying the detachment are often severely hindered by the SiOil. We aim to develop and evaluate new MRI methods to image UM patients with a SiOil tamponade and evaluate this in vivo. A dedicated MRI protocol for 3 and 7 T was developed and subsequently evaluated in three patients. The MRI protocol developed was evaluated in three patients. In the first patient, SiOil hindered follow-up and therefore MRI was indicated. No tumour recurrence was found after two follow-up scans. The second and third patient underwent vitrectomy with SiOil for assumed rhegmatogenous RD in another hospital, during which a mass was found. In these cases, MRI was used to determine whether the lesion was UM and perform measurements to plan brachytherapy treatment. In general, the proposed workflow is more complicated on 7 T than on 3 T as the off-resonance effects scale linearly with field strength. For example, the shimming procedure needed modifications at 7 T, whereas at 3 T, the automatic shimming sufficed. However, at 7 T, higher resolution images were obtained compared with 3 T (0.6 vs. 0.8 mm). A dedicated MRI protocol enables high-resolution imaging of vitrectomized eyes with SiOil tamponade, enabling treatment planning or follow-up in UM patients.


Assuntos
Imageamento por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Neoplasias Uveais/diagnóstico por imagem , Vitrectomia/métodos , Feminino , Humanos , Masculino , Melanoma/patologia , Neoplasias Uveais/patologia
17.
J Cereb Blood Flow Metab ; 39(12): 2486-2496, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30204039

RESUMO

Lacunes and white matter hyperintensities (WMHs) are features of cerebral small vessel disease (CSVD) that are associated with poor functional outcomes. However, how the two are related remains unclear. In this study, we examined the association between lacunes and several WMH features in patients with a history of vascular disease. A total of 999 patients (mean age 59 ± 10 years) with a 1.5 T brain magnetic resonance imaging (MRI) scan were included from the SMART-MR study. Lacunes were scored visually and WMH features (volume, subtype and shape) were automatically determined. Analyses consisted of linear and Poisson regression adjusted for age, sex, and total intracranial volume (ICV). Patients with lacunes (n = 188; 19%) had greater total (B = 1.03, 95% CI: 0.86 to 1.21), periventricular/confluent (B = 1.08, 95% CI: 0.89 to 1.27), and deep (B = 0.71, 95% CI: 0.44 to 0.97) natural log-transformed WMH volumes than patients without lacunes. Patients with lacunes had an increased risk of confluent type WMHs (RR = 2.41, 95% CI: 1.98 to 2.92) and deep WMHs (RR = 1.41, 95% CI: 1.22 to 1.62) and had a more irregular shape of confluent WMHs than patients without lacunes, independent of total WMH volume. In conclusion, we found that lacunes on MRI were associated with WMH features that correspond to more severe small vessel changes, mortality, and poor functional outcomes.


Assuntos
Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Leucoaraiose/diagnóstico por imagem , Imageamento por Ressonância Magnética , Substância Branca/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA