Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
2.
Biomedicines ; 12(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38927361

RESUMO

BACKGROUND: Experience with the transvenous extraction of leads used for His bundle pacing (HBP) is limited. METHODS: Analysis of 3897 extractions including 27 HBP and 253 LVP (left ventricular pacing) leads. RESULTS: The main reason for HBP lead extraction was lead failure (59.26%). The age of HBP and LVP leads (54.52 vs. 50.20 months) was comparable, whereas procedure difficulties were related to the LVP lead dwell time. The extraction of HBP leads > 40 months old was longer than the removal of younger leads (8.57 vs. 3.87 min), procedure difficulties occurred in 14.29%, and advanced tools were required in 28.57%. There were no major complications. The extraction time of dysfunctional or infected leads was similar in the HBP and LVP groups (log-rank p = 0.868) but shorter when compared to groups with other leads. Survival after the procedure did not differ between HBP and LVP groups but was shorter than in the remaining patients. CONCLUSIONS: 1. HBP is used in CRT-D systems for resynchronisation of the failing heart in 33.33%. 2. Extraction of HBP leads is most frequently performed for non-infectious indications (59.26%) and most often because of lead dysfunction (33.33%). 3. The extraction of "old" (>40 months) HBP leads is longer (8.57 vs. 3.87 min) and more difficult than the removal of "young" leads due to unexpected procedure difficulties (14.29%) and the use of second line/advanced tools (28.57%), but it does not entail the risk of major complications and procedure-related death and is comparable to those encountered in the extraction of LVP leads of a similar age. 4. Survival after lead extraction was comparable between HBP and LVP groups but shorter compared to patients who underwent the removal of other leads.

3.
Pol Arch Intern Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38895973

RESUMO

INTRODUCTION: Diagnosis of lead related infective endocarditis (LRIE) is often a real challenge. Current diagnostic criteria include LRIE definite and possible. OBJECTIVES: Comparison of the outcomes of patients with definite and possible LRIE undergoing transvenous lead extraction (TLE) procedures. PATIENTS AND METHODS: A retrospective analysis of data from 3782 patients undergoing TLE between 2006 and 2023 was performed. The study included 838 patients with definite and possible LRIE. The analysis of clinical data and short and long-term survival was performed. RESULTS: The comparison of clinical data showed more frequent occurrence of vegetations (81.58% vs 37.21%; P <0.001), positive blood cultures (66.12 % vs 51.64%; P <0.001) and septic pulmonary embolism (40.14% vs 13.78%; P <0.001) in patients with definite LRIE. Long-term mortality of patients with definite and possible LRIE (median follow up 4.61 [1.04-9.40] and 5.06 [2.07-8.75] years respectively) was 61.14% vs 49.29%; P <0.001. Predictors of mortality in patients with marked LRIE include advanced age, low left ventricular ejection fraction (LVEF), comorbidities, septic pulmonary embolism, positive blood culture, and the presence of an abandoned lead. In possible LRIE, only the influence of advanced age, low LVEF and comorbidities was demonstrated. There has been no documented direct impact of delayed diagnosis on the long-term survival of patients after TLE Conclusions: The study documented better survival in patients with possible LRIE, which confirms the need to use extended diagnostic criteria for LRIE. Implementation of appropriate treatment at an early stage of infection allows for improved prognosis.

4.
J Clin Med ; 13(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731132

RESUMO

Background: The study aimed to describe the phenomenon of leads migrated (MPLE) into the cardiovascular system (CVS). Methods: Retrospective analysis of 3847 transvenous lead extractions (TLE). Results: Over a 17-year period, 72 (1.87%) MPLEs (median dwell time 137.5 months) were extracted, which included mainly ventricular leads (56.94%). Overall, 68.06% of MPLEs had their cut proximal ends in the venous system. Most of them were pacing (95.83%) and passive fixation (98.61%) leads. Independent risk factors for MPLE included abandoned leads (OR = 8.473; p < 0.001) and leads located on both sides of the chest (2.981; p = 0.045). The higher NYHA class lowered the probability of MPLE (OR = 0.380; p < 0.001). Procedure complexity was higher in the MPLE group (procedure duration, unexpected procedure difficulties, use of additional (advanced) tools and alternative venous approach). There were no more major complications in the MPLE group, but the rate of procedural success was lower due to more frequent retention of non-removable lead fragments. Extraction of MPLEs did not influence long-term survival. Conclusions: 1. Extraction of leads with MPLE is rare among other TLE procedures (1.9%), 2. risk factors include abandoned leads and presence of leads on both sides of the chest but a higher NYHA class lowers the probability of MPLE, 3. complexity of MPLE extraction is higher regarding procedure duration, unexpected procedure difficulties, use of advanced tools and techniques but rates of major complications are comparable, and 4. extraction of MPLEs did not influence long-term survival.

5.
Medicina (Kaunas) ; 60(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38792942

RESUMO

Heart failure (HF) remains a major medical and social problem. The NT-pro-brain natriuretic peptide (NT-proBNP) and its active form, brain-type natriuretic peptide (BNP), in a simple blood test are the gold-standard biomarkers for HF diagnosis. However, even good biomarkers such as natriuretic peptides fail to predict all the risks associated with HF due to the diversity of the mechanisms involved. The pathophysiology of HF is determined by numerous factors, including oxidative stress, inflammation, neuroendocrine activation, pathological angiogenesis, changes in apoptotic pathways, fibrosis and vascular remodeling. High readmission and mortality rates prompt a search for new markers for the diagnosis, prognosis and treatment of HF. Oxidative-stress-mediated inflammation plays a crucial role in the development of subsequent changes in the failing heart and provides a new insight into this complex mechanism. Oxidative stress and inflammatory biomarkers appear to be a promising diagnostic and prognostic tool in patients with HF. This systematic review provides an overview of the current knowledge about oxidative stress and inflammation parameters as markers of HF.


Assuntos
Biomarcadores , Insuficiência Cardíaca , Inflamação , Estresse Oxidativo , Humanos , Estresse Oxidativo/fisiologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Inflamação/sangue , Biomarcadores/sangue , Biomarcadores/análise , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Prognóstico
6.
J Clin Med ; 13(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38592112

RESUMO

Background: Implantable cardioverter-defibrillator (ICD) leads are considered a risk factor for major complications (MC) during transvenous lead extraction (TLE). Methods: We analyzed 3878 TLE procedures (including 1051 ICD lead extractions). Results: In patients with ICD lead removal, implant duration was almost half as long (69.69 vs. 114.0 months; p < 0.001), procedure complexity (duration of dilatation of all extracted leads, use of more advanced tools or additional venous access) (15.13% vs. 20.78%; p < 0.001) and MC (0.67% vs. 2.62%; p < 0.001) were significantly lower as compared to patients with pacing lead extraction. The procedural success rate was higher in these patients (98.29% vs. 94.04%; p < 0.001). Extraction of two or more ICD leads or additional superior vena cava (SVC) coil significantly prolonged procedure time, increased procedure complexity and use of auxiliary or advanced tools but did not influence the rate of MC. The type of ICD lead fixation and tip position did not affect TLE complexity, complications and clinical success although passive fixation reduces the likelihood of procedural success (OR = 0.297; p = 0.011). Multivariable regression analysis showed that ICD lead implant duration ≥120 months (OR = 2.956; p < 0.001) and the number of coils in targeted ICD lead(s) (OR = 2.123; p = 0.003) but not passive-fixation ICD leads (1.361; p = 0.149) or single coil ICD leads (OR = 1.540; p = 0.177) were predictors of higher procedure complexity, but had no influence on MC or clinical and procedural success. ICD lead implant duration was of crucial importance, similar to the number of leads. Lead dwell time >10 years is associated with a high level of procedure difficulty and complexity but not with MC and procedure-related deaths. Conclusions: The main factors affecting the transvenous removal of ICD leads are implant duration and the number of targeted ICD leads. Dual coil and passive fixation ICD leads are a bit more difficult to extract whereas fixation mechanism and tip position play a much less dominant role.

7.
J Clin Med ; 13(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38673622

RESUMO

Background: Currently, there are no reports describing lead break (LB) during transvenous lead extraction (TLE). Methods: This study conducted a retrospective analysis of 3825 consecutive TLEs using mechanical sheaths. Results: Fracture of the lead, defined as LB, with a long lead fragment (LF) occurred in 2.48%, LB with a short LF in 1.20%, LB with the tip of the lead in 1.78%, and LB with loss of a free-floating LF in 0.57% of cases. In total, extractions with LB occurred in 6.04% of the cases studied. In cases in which the lead remnant comprises more than the tip only, there was a 50.31% chance of removing the lead fragment in its entirety and an 18.41% chance of significantly reducing its length (to less than 4 cm). Risk factors for LB are similar to those for major complications and increased procedure complexity, including long lead dwell time [OR = 1.018], a higher LV ejection fraction, multiple previous CIED-related procedures, and the extraction of passive fixation leads. The LECOM and LED scores also exhibit a high predictive value. All forms of LB were associated with increased procedure complexity and major complications (9.96 vs. 1.53%). There was no incidence of procedure-related death among such patients, and LB did not affect the survival statistics after TLE. Conclusions: LB during TLE occurs in 6.04% of procedures, and this predictable difficulty increases procedure complexity and the risk of major complications. Thus, the possibility of LB should be taken into account when planning the lead extraction strategy and its associated training.

8.
Biomedicines ; 12(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38672063

RESUMO

The aim of this study was to analyze the relationship between levels of sST2, NT-proBNP and oxidative stress markers in patients with reduced ejection fraction (HFrEF) due to non-ischemic cardiomyopathy. A total of 88 patients with HFrEF were divided into four groups based on left ventricular ejection fraction (≤25% and >25%) and NYHA functional class (group 1-LVEF > 25% and NYHA class I or II; group 2-LVEF > 25% and NYHA class III or IV; group III-LVEF ≤ 25% and NYHA class I or II; group IV-LVEF ≤ 25% and NYHA class III or IV). In 39 (44.32%) patients LVEF was reduced below 25%, and 22 of them (56.41%) were in NYHA functional class III/IV. Of the 49 (55.68%) patients with LVEF ≥ 25%, only 18.37% were in NYHA functional class III/IV (p < 0.001). Patients with LVEF ≥ 25% had lower levels of NT-proBNP, total oxidant status (TOS), total antioxidant capacity (TAC), and oxidative stress index (OSI). The levels of NT-proBNP but not sST-2 correlated positively with NYHA functional class (p < 0.001) and negatively with LVEF (p < 0.001). The levels of sST-2 were associated with increased TAC (p = 0.009) and uric acid (p = 0.040). These findings indicate that only NT-proBNP was related to the severity of heart failure, whereas sST2 correlated with total antioxidant capacity. Therefore, in stable patients with HFrEF due to dilated cardiomyopathy, sST2 may be an additional biomarker reflecting the redox status, but not the severity of heart failure.

10.
Medicina (Kaunas) ; 60(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38399623

RESUMO

Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Coração , Fatores de Risco , Constrição Patológica , Resultado do Tratamento , Estudos Retrospectivos
11.
J Clin Med ; 13(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38337494

RESUMO

Background: VDD (atrial sensing, ventricular sensing/pacing) leads are relatively rarely implanted; therefore, experience in their extraction is very limited. We aimed to investigate whether VDD lead removal may be a risk factor for the increased complexity of transvenous lead extraction (TLE) or major complications. Methods: We retrospectively analyzed 3808 TLE procedures (including 103 patients with VDD leads). Results: If TLE included VDD lead removal, procedure duration (lead dilation time) was prolonged, complicated extractions were slightly more common, and more advanced tools were required. This is partly due to longer implant duration (in patients with VDD systems-135.2 months; systems without VDD leads-109.3 months; p < 0.001), more frequent presence of abandoned leads (all systems containing VDD leads-22.33% and all systems without VDD leads-10.77%), and partly to the younger age of patients with VDD leads (51.74 vs. 57.72 years; p < 0.001, in the remaining patients) at the time of system implantation. VDD lead extraction does not increase the risk of major complications (1.94 vs. 2.34%; p = 0.905). Conclusions: The extraction of VDD leads may be considered a risk factor for increased procedure complexity, but not for major complications. However, this is not a direct result of VDD lead extraction but specific characteristics of the patients with VDD leads. Operator skill and team experience combined with special custom maneuvers can enable favorable results to be achieved despite the specific design of VDD leads, even with older VDD lead models.

12.
J Clin Med ; 12(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38068550

RESUMO

BACKGROUND: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, ranging from local pocket infection (PI) to lead-related infectious endocarditis (LRIE) infection spreading along the leads to the endocardium. The detection of isolated LRIE and the assessment of the spread of infection in a patient with PI is often difficult and requires complex imaging and microbiological tests. The aim of the current study is to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED, differentiating vegetation and vegetation-like masses, and assessing the extent of infections in patients with PI. METHODS: A retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006-2020, was conducted. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), and lymphocyte-to-platelet ratio (LPR) in the diagnosis of CIED infections, evaluate the spread of the infectious process in patients with PI and differentiate additional structures related to the presence of lead. RESULTS: The values of NLR and NPR were significantly higher in infectious patients than non-infectious controls (3.07 vs. 2.59; p < 0.001, and 0.02 vs. 0.01; p = 0.008) and the area under the ROC curve (AUC) was 0.59; p < 0.001 and 0.56; p < 0.001, respectively. The high specificity of the new markers in detecting the infectious process was demonstrated: 72.82% for NLR (optimal cut-off value: 3.06) and 79.47% for NPR (optimal cut off value: 0.02). The values of NLR and NPR were significantly higher in patients with vegetations than in non-infectious patients with the presence of additional lead-related masses (3.37 vs. 2.61; p < 0.001 and 0.03 vs. 0.02; p = 0.008). The AUC of NLR and NPR for the prediction of vegetations was 0.65; p < 0.001 and 0.60; p < 0.001 with the highest specificity of NPR (82.78%) and an optimal cut-off value of 0.03. NLR and NPR were higher in patients with LRIE compared to isolated PI (4.11 vs. 2.56; p < 0.001 and 0.03 vs. 0.02; p < 0.001) and the ROC curve analysis for coexistence LRIE with PI showed the AUC for NLR: 0.57; p < 0.001 and AUC for NPR: 0.55; p = 0.001. High specificity in the detection of coexistence between PI and LRIE was demonstrated for NLR (87.33%), with an optimal cut-off value of 3.13. CONCLUSIONS: Novel hematological markers (NLR and NPR) are characterized by high specificity in the initial diagnosis of CIED infections, with optimal cut-off values of 3.06 and 0.02. NLR is also useful in the assessment of the spread of infection in patients with PI, with a calculated optimal cut-off value of 3.13. NPR may be helpful in the differentiation of vegetation and vegetation-like masses with an optimal cut-off value of 0.03.

13.
J Clin Med ; 12(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38137637

RESUMO

(1) Background: Transvenous lead extraction (TLE) can become far more complex when unanticipated difficulties arise. The aim was to develop a simple scoring system that allows for the prediction of the difficulty and complexity of this significant procedure. (2) Methods: Based on analysis of 3741 TLE procedures with and without complicating factors (extended fluoroscopy time, need for second-line instruments, and advanced techniques and instruments), a five-point Complex Indicator of Difficulty of (TLE) Procedure (CID-TLEP) scale was developed. Two or more points on the CID-TLEP scale indicate a higher level of procedure complexity. (3) Results: Patient age below 51 years at first CIED implantation, number of abandoned leads, number of previous procedures, passive fixation and multiple leads to be extracted, and a ratio of dwell time of oldest lead to patient age during TLE of >0.13 are significant predictors of higher levels of lead extraction complexity. The ROC analysis demonstrates that a point total (being the sum of the odds ratios of the above variables) of >9.697 indicates a 21.83% higher probability of complex TLE (sensitivity 74.08%, specificity 74.46%). Finally, a logistic function was calculated, and we constructed a simple equation for lead extraction complexity that can predict the probability of a difficult procedure. The risk of complex extraction (as a percentage) is calculated as [1/(1 + 55.34 · 0.754X)] · 100 (p < 0.001). (4) Conclusion: The LECOM score can effectively predict the risk of a difficult transvenous lead extraction procedure, and predicting the probability of a more complex procedure may help clinicians in planning lead removal and improving patient management.

14.
Kardiol Pol ; 81(11): 1113-1121, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37937353

RESUMO

BACKGROUND: Patients with cardiac implantable electronic devices (CIEDs) may no longer be eligible for continued therapy. AIMS: The study aimed to assess the circumstances under which CIED reimplantation may not be necessary after transvenous lead extraction (TLE). METHODS: A retrospective analysis of 3646 TLE procedures was performed with assessment of indications for device reimplantation. RESULTS: Reimplantation was not performed immediately after TLE in 169 (4.6%) and, in long-term follow-up, in 146 (4.0%) of patients. No further need for CIED reimplantation was mostly associated with establishment of stable sinus rhythm (2.4%), conversion of sinus node dysfunction to chronic atrial fibrillation (AF; 1.4%), or improvement in left ventricular ejection fraction (LVEF) (0.9%). Independent prognostic factors were in the pacing groups: LVEF (odds ratio [OR], 1.03; 95% confidence interval [CI], 1.01-1.05; P <0.001), AF (OR, 3.8; 95% CI, 2.4-15.7; P <0.001), patients' age during first CIED implantation (OR, 0.97; 95% C, 0.96-0.98; P <0.001), and New York Heart Association (NYHA) class (OR, 0.616; 95% CI, 0.43-0.86; P <0.01); in the cardioverter-defibrillator group: LVEF (OR, 1.06; 95% CI, 1.04-1.09; P <001). Non-reimplanted patients had more complex procedures and more frequent complications, but survival after TLE was better in this group of patients. CONCLUSIONS: Reassessment of the need for continuation of CIED therapy should be considered in all patients following lead extraction and also before planned device replacement as TLE delay increases implant duration, complexity, and procedural risk. The predictors of non-reimplantation are a younger age during the first CIED implantation, lower NYHA class, presence of AF, and higher LVEF in pacemaker carriers, and, in the defibrillator group, only higher LVEF. A decision not to reimplant does not negatively affect the long-term prognosis.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/etiologia
15.
Pediatr Cardiol ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898588

RESUMO

The best strategy for lead management in children is a matter of debate, and our experiences are limited. This is a retrospective single-center study comparing difficulties and outcomes of transvenous lead extraction (TLE) implanted ich childhood and at age < 19 years (childhood-implanted-childhood-extracted, CICE) and at age < 19 (childhood-implanted-adulthood-extracted, CIAE). CICE patients-71 children (mean age 15.1 years) as compared to CIAE patients (114 adults (mean age 28.61 years) were more likely to have VVI than DDD pacemakers. Differences in implant duration (7.96 vs 14.08 years) appeared to be most important, but procedure complexity and outcomes also differed between the groups. Young adults with cardiac implantable electronic device implanted in childhood had more risk factors for major complications and underwent more complex procedures compared to children. Implant duration was significantly longer in CIAE patients than in children, being the most important factor that had an impact on patient safety and procedure complexity. CIAE patients were more likely to have prolonged operative duration and more complex procedures due to technical problems, and they were 2-3 times more likely to require second-line or advanced tools compared to children, but the rates of clinical and procedural success were comparable in both groups. The difference between the incidence of major complications between CICE and CIAE patients is very clear (MC 2.9 vs 7.0%, hemopericardium 1.4 vs 5.3% etc.), although statistically insignificant. Delay of lead extraction to adulthood seems to be a riskier option than planned TLE in children before growing up.

16.
Biomedicines ; 11(8)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37626732

RESUMO

Heart failure (HF) is a multifactorial clinical syndrome involving many complex processes. The causes may be related to abnormal heart structure and/or function. Changes in the renin-angiotensin-aldosterone system, the sympathetic nervous system, and the natriuretic peptide system are important in the pathophysiology of HF. Dysregulation or overexpression of these processes leads to changes in cardiac preload and afterload, changes in the vascular system, peripheral vascular dysfunction and remodeling, and endothelial dysfunction. One of the important factors responsible for the development of heart failure at the cellular level is oxidative stress. This condition leads to deleterious cellular effects as increased levels of free radicals gradually disrupt the state of equilibrium, and, as a consequence, the internal antioxidant defense system is damaged. This review focuses on pharmacotherapy for chronic heart failure with regard to oxidation-reduction metabolism, with special attention paid to the latest group of drugs, SGLT2 inhibitors-an integral part of HF treatment. These drugs have been shown to have beneficial effects by protecting the antioxidant system at the cellular level.

17.
Cardiovasc Diabetol ; 22(1): 177, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443009

RESUMO

BACKGROUND: Recent studies revealed that alterations in glucose and lipid metabolism in idiopathic pulmonary arterial hypertension (IPAH) are associated with disease severity and poor survival. However, data regarding the impact of diabetes mellitus (DM) on the prognosis of patients with IPAH remain scarce. The aim of our study was to determine that impact using data from a national multicentre prospective pulmonary hypertension registry. METHODS: We analysed data of adult patients with IPAH from the Database of Pulmonary Hypertension in the Polish population (BNP­PL) between March 1, 2018 and August 31, 2020. Upon admission, clinical, echocardiographic, and haemodynamic data were collected at 21 Polish IPAH reference centres. The all-cause mortality was assessed during a 30-month follow-up period. To adjust for differences in age, body mass index (BMI), and comorbidities between patients with and without DM, a 2-group propensity score matching was performed using a 1:1 pairing algorithm. RESULTS: A total of 532 patients with IPAH were included in the study and 25.6% were diagnosed with DM. Further matched analysis was performed in 136 patients with DM and 136 without DM. DM was associated with older age, higher BMI, more advanced exertional dyspnea, increased levels of N-terminal pro-brain natriuretic peptide, larger right atrial area, increased mean right atrial pressure, mean pulmonary artery pressure, pulmonary vascular resistance, and all-cause mortality compared with no DM. CONCLUSIONS: Patients with IPAH and DM present with more advanced pulmonary vascular disease and worse survival than counterparts without DM independently of age, BMI, and cardiovascular comorbidities.


Assuntos
Diabetes Mellitus , Hipertensão Pulmonar , Adulto , Humanos , Hipertensão Pulmonar Primária Familiar/diagnóstico , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/epidemiologia , Hipertensão Pulmonar/complicações , Estudos Prospectivos , Polônia/epidemiologia , Prognóstico , Gravidade do Paciente , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Sistema de Registros
18.
J Clin Med ; 12(8)2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37109149

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) should be completed, even when facing difficulties which have yet to be described. The aim was to explore unexpected TLE obstacles (the circumstances of the occurrence and influence on TLE outcome). METHODS: The retrospective analysis of a single centre database containing 3721 TLEs. RESULTS: Unexpected procedure difficulties (UPDs) occurred in 18.43% of cases (singles in 12.20% of cases and multiples in 6.26% of cases). These included blockages in the lead venous approach in3.28% of cases, functional lead dislodgement in 0.91% of cases, and loss of broken lead fragment in 0.60% of cases. All of them, including implant vein-in 7.98% of cases, lead fracture during extraction-in 3.84% of cases, and lead-to-lead adherence-in 6.59% of cases, Byrd dilator collapse-in 3.41% of cases, including the use of an alternative prolonged the procedure but had no influence on long-term mortality. Most of the occurrences were associated with lead dwell time, younger patient age, lead burden, and poorer procedure effectiveness and complications (common cause). However, some of the problems seemed to be related to cardiac implantable electronic devices (CIED) implantation and the subsequent lead management strategy. A more complete list of all tips and tricks is still required. CONCLUSIONS: (1) The complexity of the lead extraction procedure combines both prolonged procedure duration and the occurrence of lesser-known UPDs. (2) UPDs are present in nearly one fifth of the TLE procedures, and can occur simultaneously. (3) UPDs, which usually force the extractor to expand the range of techniques and tools, should become part of the training in transvenous lead extraction.

19.
J Clin Med ; 12(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37109174

RESUMO

BACKGROUND: The long-term significance of lead remnants (LR) following transvenous lead extraction (TLE) remains disputable, especially in infectious patients. METHODS: Retrospective analysis of 3741 TLEs focused on the relationship between LR and procedure complexity, complications and long-term survival. RESULTS: The study group consisted of 156 individuals with LR (4.17%), and the control group consisted of 3585 patients with completely removed lead(s). In a multivariable model, a younger patient age at CIED implantation, more CIED procedures and procedure complexity were independent risk factors for retention of non-removable LR. Although patients with LR showed better survival outcomes following TLE (log rank p = 0.041 for non-infectious group and p = 0.017 for infectious group), multivariable Cox regression analysis did not confirm the prognostic significance of LR either in non-infectious [HR = 0.777; p = 0.262], infectious [HR = 0.983; p = 0.934] or the entire group of patients [HR = 0.858; p = 0.321]. CONCLUSIONS: 1. Non-removable LRs are encountered in 4.17% of patients. 2. CIED infection has no influence on retention of LRs, but younger patient age, multiple CIED-related procedures and higher levels of procedure complexity are independent risk factors for the presence of LR. 3. Better survival outcomes following TLE in patients with LRs are not the effects of their presence but younger patient and better health status.

20.
Artigo em Inglês | MEDLINE | ID: mdl-36901635

RESUMO

Pulmonary arterial hypertension (PAH) is defined as an elevated mean pulmonary artery pressure (mPAP) of >20 mmHg together with a pulmonary arterial wedge pressure (PAWP) of ≤15 mmHg and pulmonary vascular resistance (PVR) of>2 Wood units (WU). Although the total mortality of pregnant women with PAH has decreased significantly in recent years and is reported to be around 12% in some databases, total mortality is still at an unacceptably high percentage. Moreover, some subgroups, such as patients with Eisenmenger's syndrome, have a particularly high mortality rate of up to 36%. Pregnancy in patients with PAH is contraindicated; its appearance is an indication for a planned termination. Education of patients with PAH, including counseling on effective contraception, is essential. During pregnancy, blood volume, heart rate, and cardiac output increase, while PVR and systemic vascular resistance decrease. The hemostatic balance is shifted towards hypercoagulability. Among PAH-specific drugs, the use of inhaled or intravenous prostacyclins, phosphodiesterase inhibitors, and calcium channel blockers (in patients with preserved vasoreactivity) is acceptable. Endothelin receptor antagonists and riociguat are contraindicated. Childbirth can take place through either vaginal delivery or caesarean section; similarly, neuraxial and general anesthesia have proven indications. In a situation where all pharmacological options have been used in pregnant or postpartum patients in a serious condition, veno-arterial ECMO is a useful therapeutic option. For PAH patients who want to become mothers, an option that does not endanger their lives is adoption.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Humanos , Feminino , Gravidez , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/tratamento farmacológico , Cesárea , Bloqueadores dos Canais de Cálcio , Parto Obstétrico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA