Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Acta Radiol ; 63(3): 328-335, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33657848

RESUMO

BACKGROUND: High-resolution computed tomography (HRCT) is essential in narrowing the possible differential diagnoses of diffuse and interstitial lung diseases. PURPOSE: To investigate the value of a novel computer-based decision support system (CDSS) for facilitating diagnosis of diffuse lung diseases at HRCT. MATERIAL AND METHODS: A CDSS was developed that includes about 100 different illustrations of the most common HRCT signs and patterns and describes the corresponding pathologies in detail. The logical set-up of the software facilitates a structured evaluation. By selecting one or more CT patterns, the program generates a ranked list of the most likely differential diagnoses. Three independent and blinded radiology residents initially evaluated 40 cases with different lung diseases alone; after at least 12 weeks, observers re-evaluated all cases using the CDSS. RESULTS: In 40 patients, a total of 113 HRCT patterns were evaluated. The percentage of correctly classified patterns was higher with CDSS (96.8%) compared to assessment without CDSS (90.3%; P < 0.01). Moreover, the percentage of correct diagnosis (81.7% vs. 64.2%) and differential diagnoses (89.2% vs. 38.3%) were superior with CDSS compared to evaluation without CDSS (both P < 0.01). CONCLUSION: Addition of a CDSS using a structured approach providing explanations of typical HRCT patterns and graphical illustrations significantly improved the performance of trainees in characterizing and correctly identifying diffuse lung diseases.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
2.
SN Compr Clin Med ; 2(11): 2151-2157, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33024935

RESUMO

The current SARS-CoV-2 outbreak leads to a growing need of point-of-care thoracic imaging that is compatible with isolation settings and infection prevention precautions. We retrospectively reviewed 17 COVID-19 patients who received point-of-care lung ultrasound imaging in our isolation unit. Lung ultrasound was able to detect interstitial lung disease effectively; severe cases showed bilaterally distributed B-Lines with or without consolidations; one case showed bilateral pleural plaques. Corresponding to CT scans, interstitial involvement is accurately depicted as B-Lines on lung ultrasound. Lung ultrasound might be suitable for detecting interstitial involvement in a bedside setting under high security isolation precautions.

3.
Clin Transplant ; 34(9): e13877, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32277846

RESUMO

BACKGROUND: Pneumocystis jirovecii pneumonia (PcP) remains a life-threatening opportunistic infection after solid organ transplantation, even in the era of Pneumocystis prophylaxis. The association between risk of developing PcP and low CD4+ T cell counts has been well established. However, it is unknown whether lymphopenia in the context of post-renal transplant PcP increases the risk of mortality. METHODS: We carried out a retrospective analysis of a cohort of kidney transplant patients with PcP (n = 49) to determine the risk factors for mortality associated with PcP. We correlated clinical and demographic data with the outcome of the disease. For CD4+ T cell counts, we used the Wilcoxon rank sum test for in-hospital mortality and a Cox proportional-hazards regression model for 60-day mortality. RESULTS: In univariate analyses, high CRP, high neutrophils, CD4+ T cell lymphopenia, mechanical ventilation, and high acute kidney injury network stage were associated with in-hospital mortality following presentation with PcP. In a receiver-operator characteristic (ROC) analysis, an optimum cutoff of ≤200 CD4+ T cells/µL predicted in-hospital mortality, CD4+ T cell lymphopenia remained a risk factor in a Cox regression model. CONCLUSIONS: Low CD4+ T cell count in kidney transplant recipients is a biomarker for disease severity and a risk factor for in-hospital mortality following presentation with PcP.


Assuntos
Transplante de Rim , Linfopenia , Pneumocystis carinii , Pneumonia por Pneumocystis , Linfócitos T CD4-Positivos , Humanos , Transplante de Rim/efeitos adversos , Linfopenia/etiologia , Pneumonia por Pneumocystis/etiologia , Estudos Retrospectivos
4.
Curr Med Imaging Rev ; 15(4): 373-379, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31989906

RESUMO

PURPOSE: To investigate image quality, and radiation dose between ECG-gated singlesource and dual-source CT Angiography (CTA) protocols for planning of Trans-catheter Aortic Valve Implantation (TAVI) with a reference non ECG-gated single-source protocol. METHODS: A total of 120 patients were included in four groups: Non ECG-gated single-source (SS), ECG-gated single-source (SSECG), ECG-gated dual-source high-pitch (DSECG), or non-ECG-gated dual-source high-pitch mode (DS). Qualitative image quality of the aortic annulus, aortic valve, and coronary ostia as well as presence of motion or stair-step artefacts of the thoracic aorta were independently assessed by two readers. Quantitative image quality was assessed to calculate contrast to noise ratio. RESULTS: Subjective and objective scoring of motion artefacts was significantly reduced in SSECG, DSECG and DS (p= 0.010). The imaging length was comparable between groups. Aortic annulus, aortic valve, and coronary ostia were reliably evaluable in all patients with SSECG, DSECG and DS protocols. CONCLUSION: High-pitch, dual-source CT angiography of the whole aorta with or without ECG gating is a dose-efficient and time-saving examination strategy before TAVI. However acquisition timing within the cardiac cycle needs to be taken into account.


Assuntos
Aorta/diagnóstico por imagem , Aortografia/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Tomografia Computadorizada/métodos , Eletrocardiografia/métodos , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Planejamento de Assistência ao Paciente , Doses de Radiação
5.
Eur J Radiol ; 94: 125-132, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28712695

RESUMO

PURPOSE: To assess image quality and diagnostic performance of a noise-optimized algorithm to reconstruct virtual monoenergetic images (VMI+) for the detection of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) using dual-energy CT angiography (DE-CTA). MATERIALS AND METHODS: Seventy-five patients (42 men; 66.2±11.7years) underwent DE-CTA following EVAR. Arterial phase images were acquired in dual-energy mode for the reconstruction of standard linearly-blended M_0.5, VMI+ and traditional monoenergetic images (VMI) at 40-100keV in 10-keV intervals. Contrast-to-noise ratios (CNR) were calculated for the area of leakage in patients with endoleaks. Diagnostic accuracy for endoleak detection was evaluated by three blinded radiologists using the objectively best series for each reconstruction technique. RESULTS: Thirty-four out of 75 patients showed endoleaks. Quantitative image parameters were highest at 40-keV VMI+ (CNR, 21.3±11.1), compared to M_0.5 (CNR, 10.9±5.5) and all VMI series that showed highest values at 70keV (CNR, 13.5±6.6; all P<0.001). ROC analysis for endoleak detection revealed an area under the curve (AUC) of 0.992 for 40-keV VMI+ series, which was significantly higher (P≤0.039) compared to 70-keV VMI (0.914) and M_0.5 series (0.916). CONCLUSIONS: Noise-optimized VMI+ series at 40keV improve diagnostic accuracy for the detection and rule-out of endoleaks after EVAR.


Assuntos
Aneurisma Aórtico/cirurgia , Endoleak/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aneurisma Aórtico/fisiopatologia , Endoleak/fisiopatologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Cureus ; 8(7): e705, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-27588226

RESUMO

PURPOSE: Robotic guided stereotactic radiosurgery has recently been investigated for the treatment of atrial fibrillation (AF). Before moving into human treatments, multiple implications for treatment planning given a potential target tracking approach have to be considered. MATERIALS & METHODS: Theoretical AF radiosurgery treatment plans for twenty-four patients were generated for baseline comparison. Eighteen patients were investigated under ideal tracking conditions, twelve patients under regional dose rate (RDR = applied dose over a certain time window) optimized conditions (beam delivery sequence sorting according to regional beam targeting), four patients under ultrasound tracking conditions (beam block of the ultrasound probe) and four patients with temporary single fiducial tracking conditions (differential surrogate-to-target respiratory and cardiac motion). RESULTS: With currently known guidelines on dose limitations of critical structures, treatment planning for AF radiosurgery with 25 Gy under ideal tracking conditions with a 3 mm safety margin may only be feasible in less than 40% of the patients due to the unfavorable esophagus and bronchial tree location relative to the left atrial antrum (target area). Beam delivery sequence sorting showed a large increase in RDR coverage (% of voxels having a larger dose rate for a given time window) of 10.8-92.4% (median, 38.0%) for a 40-50 min time window, which may be significant for non-malignant targets. For ultrasound tracking, blocking beams through the ultrasound probe was found to have no visible impact on plan quality given previous optimal ultrasound window estimation for the planning CT. For fiducial tracking in the right atrial septum, the differential motion may reduce target coverage by up to -24.9% which could be reduced to a median of -0.8% (maximum, -12.0%) by using 4D dose optimization. The cardiac motion was also found to have an impact on the dose distribution, at the anterior left atrial wall; however, the results need to be verified. CONCLUSION: Robotic AF radiosurgery with 25 Gy may be feasible in a subgroup of patients under ideal tracking conditions. Ultrasound tracking was found to have the lowest impact on treatment planning and given its real-time imaging capability should be considered for AF robotic radiosurgery. Nevertheless, advanced treatment planning using RDR or 4D respiratory and cardiac dose optimization may be still advised despite using ideal tracking methods.

7.
Cardiovasc Intervent Radiol ; 39(2): 261-70, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26148648

RESUMO

PURPOSE: To assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management. MATERIALS AND METHODS: The study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann-Whitney U test and Fisher's exact tests were used for statistical analysis. p values <0.05 were considered statistically significant. RESULTS: The incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both groups). The incidence of pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7 patients: 13.7 %), from which one patient developed a persistent air leakage necessitating pleurodesis. CONCLUSION: Pneumothorax complicating CT-guided core biopsy of pulmonary lesions, showed the insignificant difference between coaxial and non-coaxial techniques. However, both techniques have the same significant risk factors including small and basal lesions, increased lesion's depth from pleural surface, and increased length of aerated lung parenchyma crossed by biopsy needle and passing through pulmonary fissures in the needle tract.


Assuntos
Biópsia Guiada por Imagem/efeitos adversos , Pneumopatias/patologia , Pneumotórax/etiologia , Pneumotórax/terapia , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
8.
Eur J Radiol ; 83(12): 2167-2171, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25445897

RESUMO

BACKGROUND: To evaluate the effectiveness of lymphography as a minimally invasive treatment option of lymphatic leakage in terms of local control and to investigate which parameters influence the success rate. METHOD: This retrospective study protocol was approved by the ethic committee. Patient history, imaging data, therapeutic options and follow-up were recorded and retrospectively analyzed. Between June 1998 and February 2013, 71 patients (m:w = 42:29, mean age, 52.4; range 42­75 years) with lymphatic leakage in form of lymphatic fistulas (n = 37), lymphocele (n = 11), chylothorax (n = 13) and chylous ascites (n = 10)underwent lymphography. Sixty-four patients (90.1%) underwent successful lymphography while lymphography failed in 7 cases. Therapeutic success was evaluated and correlated to the volume of lymphatic leakage and to the volume of the applied iodized oil. RESULT: Signs of leakage or contrast extravasation were directly detected in 64 patients. Of 64 patients, 45 patients (70.3%) were treated and cured after lymphography. Based on the lymphography findings, 19 patients (29.7%) underwent surgical intervention with a completely occlusion of lymphatic leakage. The lymphatic leak could be completely occluded in 96.8% of patients when the lymphatic drainage volume was less than 200 mL/day (n = 33). Even when lymphatic drainage was higher than 200 mL/day (n = 31),therapeutic lymphography was still successful in 58.1% of the patients. CONCLUSION: Lymphography is an effective, minimally invasive method in the detection and treatment of lymphatic leakage. The volume of lymphatic drainage per day is a significant predictor of the therapeutic success rate.


Assuntos
Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/terapia , Linfografia , Adulto , Idoso , Quilotórax/diagnóstico por imagem , Quilotórax/terapia , Ascite Quilosa/diagnóstico por imagem , Ascite Quilosa/terapia , Feminino , Fístula/diagnóstico por imagem , Fístula/terapia , Humanos , Linfa , Linfocele/diagnóstico por imagem , Linfocele/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
9.
J Immunother Cancer ; 2: 27, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25324973

RESUMO

BACKGROUND: Aviscumine, a recombinant plant protein, is an immune modulator that induces ribotoxic stress at the 28S ribosomal RNA subunit. In this way cytokine release and T-cell responses are enhanced. This phase II trial was conducted to test the efficacy and safety of aviscumine in patients with systemically pre-treated metastatic melanoma stage IV. METHODS: A total of 32 patients with progressive stage IV melanoma after failure of standard therapy were enrolled onto a single-arm, multi-centre, open-label, phase II trial. All patients had an ECOG performance status of 0 or 1. Patients received 350 ng aviscumine twice weekly by subcutaneous injection until progression. The primary end points were progression-free survival (PFS) and overall survival (OS). Safety was assessed as adverse events (AEs). Tumor response was assessed every eight weeks and survival of patients was followed up to one year after the end of therapy. Thirty one patients (intent-to-treat population (ITT)) were assessed for efficacy; safety was assessed in the whole population. RESULTS: One patient achieved a partial response (PR) and 10 patients showed stable disease/no change (SD). The median progression-free survival (mPFS) was 63 days (95% CI 57-85) and median overall survival (mOS) was 335 days (95% CI 210-604). In total 210 treatment-emergent adverse events were recorded. Grade 1 or 2 AEs occurred in 72% of patients and were mostly application-site effects such as pruritus Grade 3-4 treatment-emergent drug-related adverse events occurred in 9% of patients. CONCLUSION: These results suggest that aviscumine may have a clinical impact in patients with previously treated metastatic melanoma and provide rationale for further clinical evaluation of this agent. In the light of effective new immune checkpoint blockers it might be a candidate for combinations with these agents. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00658437.

10.
Eur J Radiol ; 83(10): 1945-52, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25063212

RESUMO

PURPOSE: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. MATERIALS AND METHODS: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann-Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. RESULTS: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p=0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p=0.0003) in the non-coaxial group and 57.7% (41/71, p=0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p=0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion's depth from the pleural surface (p=0.021 and 0.018 in non-coaxial and coaxial groups respectively), increased distance of traversed lung in the needle track of more than 2.5 cm (p=0.001 in both groups). Insignificant risk factors were patient's age, gender or emphysema in both groups (p value >0.1 in both groups). Concomitant incidence of pneumothorax was 32.3% (21/65) in non-coaxial group and 36.6% (26/71) in coaxial group. Pulmonary hemorrhage in the majority of cases was treated conservatively. CONCLUSION: Pulmonary hemorrhage complicating CT-guided core biopsy of pulmonary lesions, showed insignificant difference between coaxial and non-coaxial techniques. Significant risk factors of pulmonary hemorrhage included small and basal lesions, increased lesion's depth from pleural surface, increased length of aerated lung parenchyma crossed by biopsy needle and passing through vessels within the lung during puncture.


Assuntos
Biópsia com Agulha de Grande Calibre , Hemorragia/etiologia , Pneumopatias/patologia , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
11.
World J Radiol ; 5(7): 253-8, 2013 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-23908695

RESUMO

AIM: To retrospectively analyze changes in clinical indication, referring medical specialty and detected pathology for small bowel double-contrast examinations. METHODS: Two hundred and forty-one (n = 143 females; n = 98 males; 01.01.1990-31.12.1990) and 384 (n = 225 females; n = 159 males; 01.01.2004-31.12.2010) patients underwent enteroclysis, respectively. All examinations were performed in standardized double-contrast technique. After placement of a nasojejunal probe distal to the ligament of Treitz, radiopaque contrast media followed by X-ray negative distending contrast media were administered. Following this standardized projections in all four abdominal quadrants were acquired. Depending on the detected pathology further documentation was carried out by focused imaging. Examination protocols were reviewed and compared concerning requesting unit, indication and final report. RESULTS: Two hundred and forty-one examinations in 1990 faced an average of 55 examinations per year from 2004-2010. There was an increase of examinations for gastroenterological (33.6% to 64.6%) and pediatric (0.4% to 7.8%) indications while internal (29.0% to 6.0% for inpatients and from 16.6% to 9.1% for outpatients) and surgical (12.4% to 7.3%) referrals significantly decreased. "Follow-up of Crohn's disease" (33.1%) and "bleeding/tumor search" (15.1%) represented the most frequent clinical indications. A total of 34% (1990) and 53.4% (2004-2010) examinations yielded pathologic findings. In the period 01.01.2004 -31.12.2010 the largest proportion of pathological findings was found in patients with diagnosed Crohn's disease (73.5%), followed by patients with abdominal pain (67.6% with history of surgery and 52.6% without history of surgery), chronic diarrhea (41.7%), suspected Crohn's disease (39.5%) and search for gastrointestinal bleeding source/tumor (19.1%). The most common pathologies diagnosed by enteroclysis were "changes in Crohn's disease" (25.0%) and "adhesions /strictures" (12.2%). CONCLUSION: "Crohn's disease" represents the main indication for enteroclysis. The relative increase of pathologic findings reflects today's well directed use of enteroclysis.

12.
Health Phys ; 105(2): 156-64, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23799500

RESUMO

The purpose of this study was to determine the effect of contrast material and retrospective ECG-gating on radiation dose in an adult cardiac dual-energy computed tomography (DECT). Sixty-two patients underwent CT cardiac examination with a Somatom Definition Flash DECT using tube voltages of 100 kV without filter and 140 kV with a tin filter (mean effective mA s: arterial 72.39 and 62.94, venous 93.21 and 78.45, and late phase 134.5 and 118.2). The arterial and late phases were examined with retrospective ECG-gating, but gating was not used for the venous phase. Seventy milliliters (70 ml) iodinated contrast material (CM) was injected into the patient during examination. The effective doses (ED) were calculated from dose-length-product (DLP) and computed tomographic dose index volume (CTDIvol) using the latest k-factor (0.028). Pearson's correlation coefficient was used for statistical tests on continuous variables. Mean CTDIvol and DLP were lower in the late phase (10.15 ± 1.5 mGy and 202.9 ± 23 mGy cm) compared to the arterial phase (19.69 ± 3 mGy and 394 ± 90 mGy cm). Differences between the arterial and late phase were statistically significant (p = 0.005), and mean values for the late phase were 48.5% lower than mean values for the arterial phase. Mean CTDIvol and DLP were lower in venous (7.72 ± 1 mGy and 154.3 ± 17 mGy cm) compared to late phase (10.15 ± 1.5 mGy and 202.9 ± 23 mGy cm). The difference between venous and late phase was statistically significant (p < 0.001). The mean results for the venous phase were 24% lower than those for the late phase. This study shows that contrast material (CM) absorbs radiation significantly and increases dose by 48.5% in an adult cardiac dual-energy CT with retrospective ECG-gating. Care must be taken to determine the type, concentration, and volume of CM used for the scan. The dual-energy non-ECG-gated technique decreased radiation dose by 24% compared to the ECG-gated technique. ECG-gated cardiac examination should be limited to patients with strong clinical indications. SNR and HU increased with decreasing energy. The image noise values showed a negligible difference in the arterial and late phase datasets, and this did not affect the diagnostic quality of the image evaluation.


Assuntos
Meios de Contraste/farmacologia , Eletrocardiografia , Coração/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Coração/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Eur J Radiol ; 82(6): 1028-33, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23375815

RESUMO

OBJECTIVE: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. METHODS: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5s, group 1; 10s, group 2; 12s, group 3; 14s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. RESULTS: The most homogeneous enhancement of the aorta was reached with a delay of 10s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p<0.001) shorter in the high-pitch group (7.7s vs. 1.7s for group 1 vs. 2, 3 and 4). CONCLUSION: In high-pitch CT angiography using a start delay of 10s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Adulto Jovem
14.
Eur Radiol ; 23(6): 1582-93, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23250112

RESUMO

OBJECTIVE: Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. METHODS: A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. RESULTS: Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. CONCLUSION: A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. KEY POINTS: • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.


Assuntos
Angiografia Digital/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Raios X
15.
J Thorac Imaging ; 27(6): 382-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22627616

RESUMO

PURPOSE: The purpose of this study was to objectively analyze motion artifacts on thoracic computed tomography (CT) with dual-source high-pitch and single-source techniques when using a no-breath-hold technique to examine patients who have difficulty complying with breath-holding instructions. MATERIALS AND METHODS: A total of 120 patients who received CT of the thorax with a free-breathing technique in single-source (16 slices and 128 slices; pitch = 1.2) and dual-source (pitch = 3.0) manners were evaluated retrospectively. In each of the 3 study groups, movements of the diaphragm and pulsations of the aortic root and main pulmonary artery were analyzed for their number and severity (blurred distance). RESULTS: No motion artifacts of the diaphragm were identified using a pitch of 3.0 (compared with n = 14 for single-source CT using 128 slices and n = 24 using 16-slice CT). In single-source examinations, the severity of artifacts was similar between 128-slice CT and 16-slice CT: blurring distance of the lung parenchyma due to diaphragm movements was 14 versus 16 mm, and double contours of the aorta were measured as 8 and 9 mm, respectively. CONCLUSIONS: A high-pitch, dual-source mode is potentially advantageous for evaluating the lung parenchyma and vascular structures in patients who have difficulty complying with breath-holding instructions. Increasing from 16 to 128 slices can significantly reduce the number and severity of motion artifacts.


Assuntos
Artefatos , Movimento (Física) , Radiografia Torácica/métodos , Respiração , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tórax
16.
Eur Radiol ; 22(1): 129-37, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21915607

RESUMO

OBJECTIVE: To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. METHODS: Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. RESULTS: Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. CONCLUSION: High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI).


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Artefatos , Angiografia Coronária , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/fisiopatologia , Doenças da Aorta/fisiopatologia , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
17.
Eur J Radiol ; 81(10): 2887-91, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22019597

RESUMO

PURPOSE: To compare test bolus and bolus tracking for the determination of scan delay of high-pitch dual-source CT pulmonary angiography in patients with suspected pulmonary embolism using 50 ml of contrast material. MATERIALS AND METHODS: Data of 80 consecutive patients referred for CT pulmonary angiography were evaluated. All scans were performed on a 128-channel dual-source CT scanner with a high-pitch protocol (pitch 3.0, 100 kV, 180 mAs). Contrast enhancement was achieved by injecting 50 ml of iomeprol followed by a saline chaser of 50 ml injected at a rate of 4 ml/s. The scan delay was determined using either the test bolus (n=40) or bolus tracking (n=40) technique. Test bolus required another 15 ml CM to determine time to peak enhancement of the contrast bolus within the pulmonary trunk. Attenuation profiles in the pulmonary trunk and on segmental level as well as in the ascending aorta were measured to evaluate the timing techniques. Additionally, overall image quality was evaluated. RESULTS: In all patients an adequate and homogeneous contrast enhancement of more than 250 HU was achieved in the pulmonary arteries. No statistically significant difference between test bolus and bolus tracking was found regarding attenuation of the pulmonary arteries or overall image quality. However, using bolus tracking 15 ml CM less was injected. CONCLUSION: A homogeneous opacification of the pulmonary arteries and sufficient image quality can be achieved with both the bolus tracking and test bolus techniques with significant lower contrast doses compared to conventional contrast material injection protocols.


Assuntos
Angiografia/métodos , Meios de Contraste/administração & dosagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Eur Radiol ; 21(10): 2139-47, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21614614

RESUMO

OBJECTIVE: To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). METHODS: Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. RESULTS: Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and >0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 ± 1.6 mGy/170 ± 41 mGycm) compared to group 1 (8.5 ± 2.6 mGy/235 ± 117 mGycm), group 2 (9.2 ± 3.3 mGy/224 ± 122 mGycm) and group 3 (8.7 ± 2.8 mGy/246 ± 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 ± 3 HU) and group 1 (13 ± 6 HU) compared to group 3 and 2 (16 ± 6 HU and 23 ± 9). CONCLUSION: The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.


Assuntos
Angiografia/métodos , Pulmão/patologia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Embolia Pulmonar/patologia , Doses de Radiação , Radiografia Torácica/métodos
19.
AJR Am J Roentgenol ; 196(6): 1368-71, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606301

RESUMO

OBJECTIVE: The purpose of this article is to compare workflow efficiency between a conventional computed radiography (CR) system and a novel, portable, cassette-sized, and wireless flat-panel digital radiography (DR) system. MATERIALS AND METHODS: Observational time-motion analyses were performed at one site at which CR and the new portable DR system are used concurrently. The workflow steps of both systems were identified and categorized to facilitate comparison. The times required for examination preparation, patient positioning, exposure, postacquisition processing, and the examination as a whole were recorded by a neutral observer. Timing differences between the CR and portable DR systems were compared, and all data were analyzed using commercially available statistical software. Nine general radiographic examination types were selected, with approximately 50 patients per examination type. RESULTS: A total of 941 examinations (CR, n = 474; portable DR, n = 467) were timed in this study. Total examination time differences between CR and portable DR system (mean, 26.44 seconds; median 26.99 seconds) were found to be statistically significant (p < 0.001), with DR proving faster than CR. The single largest contributor to the time difference between CR and portable DR was postacquisition processing (mean, 26.58 seconds; median, 25.91 seconds), which was a composite of multiple individual steps, including cassette transport (CR only, mean, 13.22 seconds; median, 12.74 seconds), cassette readout (mean, 10.15 seconds; median, 10.4 seconds), and postprocessing (mean, 3.21 seconds; median, 3.11 seconds). CONCLUSION: Overall radiographer time was significantly shorter when performing examination-related tasks with the novel, portable DR system than when performing comparable tasks with the CR system, a difference that appears to result largely from technology configuration.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Eficiência Organizacional , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Estudos de Tempo e Movimento , Ecrans Intensificadores para Raios X
20.
Eur Radiol ; 21(9): 1914-21, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533631

RESUMO

OBJECTIVE: To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). METHODS: 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. RESULTS: D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p < 0.003). There were 2 deaths and 1 readmission due of PE in 18 patients with >5% RelPD, while no such events were found for patients with <5% RelPD. CONCLUSION: Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Pulmão/irrigação sanguínea , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo/fisiologia , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos de Coortes , Intervalos de Confiança , Feminino , Testes de Função Cardíaca , Humanos , Estimativa de Kaplan-Meier , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Circulação Pulmonar/fisiologia , Embolia Pulmonar/sangue , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida , Função Ventricular Direita/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA