Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JOR Spine ; 6(2): e1251, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361332

RESUMO

Background Context: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first-generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)-sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra-high-molecular-weight-polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed. Purpose: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6-degrees-of-freedom was performed. Study Design: A canine cadaveric biomechanical study. Methods: Six cadaveric canine specimens (C3-C6) were tested in flexion-extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4-C5 disc replacement with bioAID, and after C4-C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of ±1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3-C4). Results: The bioAID retained the sigmoid shape of the moment-rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID-treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3-C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance. Conclusion: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs.

2.
J Mech Behav Biomed Mater ; 142: 105808, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37087956

RESUMO

A novel biomimetic artificial intervertebral disc (bioAID) replacement implant has been developed containing a swelling hydrogel representing the nucleus pulposus, a tensile strong fiber jacket as annulus fibrosus and titanium endplates with pins to primarily secure the device between the vertebral bodies. In this study, the design safety of this novel implant was evaluated based on several biomechanical parameters, namely compressive strength, shear-compressive strength, risk of subsidence and device expulsion as well as identifying the diurnal creep-recovery characteristics of the device. The bioAID remained intact up to 1 kN under static axial compression and only 0.4 mm of translation was observed under a compressive shear load of 20 N. No subsidence was observed after 0.5 million cycles of sinusoidal compressive loading between 50 and 225 N. After applying 400 N in antero-posterior direction under 100 N axial compressive preload, approximately 2 mm displacement was found, being within the range of displacements reported for other commercially available cervical disc replacement devices. The diurnal creep recovery behavior of the bioAID closely resembled what has been reported for natural intervertebral discs in literature. Overall, these results indicate that the current design can withstand (shear-compression loads and is able to remain fixed in a mechanical design resembling the vertebral bodies. Moreover, it is one of the first implants that can closely mimic the poroelastic and viscoelastic behavior of natural disc under a diurnal loading pattern.


Assuntos
Anel Fibroso , Disco Intervertebral , Biomimética , Vértebras Lombares , Disco Intervertebral/cirurgia , Vértebras Cervicais/cirurgia , Força Compressiva , Estresse Mecânico , Fenômenos Biomecânicos , Suporte de Carga
3.
J Biomed Mater Res B Appl Biomater ; 111(2): 442-452, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36111647

RESUMO

A novel biomimetic artificial intervertebral disc (bioAID) for the cervical spine was developed, containing a hydrogel core representing the nucleus pulposus, an UHMWPE fiber jacket as annulus fibrosis, and titanium endplates with pins for mechanical fixation. Osseointegration of the UHMWPE fibers to adjacent bone structures is required to achieve proper biomimetic behavior and to provide long-term stability. Therefore, the aim of this study was to assess the osteoconductivity of several surface modifications of UHMWPE fabrics, 2D weft-knitted, using non-treated UHMWPE fibers (N), plasma treated UHMWPE fibers (PT), 10% hydroxy apatite (HA) loaded UHMWPE fibers (10%HA), plasma treated 10%HA UHMWPE fibers (PT-10%HA), 15%HA loaded UHMWPE fibers (15%HA) and plasma treated 15%HA UHMWPE fibers (PT-15%HA). Scanning electron microscopy (SEM) was used for surface characterization. Biological effects were assessed by evaluating initial cell attachment (SEM, DNA content), metabolic activity (PrestoBlue assay), proliferation, differentiation (alkaline phosphatase activity) and mineralization (energy dispersive x-ray, EDX analysis) using human bone marrow stromal cells. Plasma treated samples showed increased initial cell attachment, indicating the importance of hydrophilicity for cell attachment. However, incorporation only of HA or plasma treatment alone was not sufficient to result in upregulated alkaline phosphatase activity (ALP) activity. Combining HA loaded fibers with plasma treatment showed a combined effect, leading to increased cell attachment and upregulated ALP activity. Based on these results, combination of HA loaded UHMWPE fibers and plasma treatment provided the most promising fabric surface for facilitating bone ingrowth.


Assuntos
Fosfatase Alcalina , Polietileno , Humanos , Polietilenos/química , Apatitas , Próteses e Implantes
4.
Spine J ; 20(12): 1911-1924, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32810609

RESUMO

Cervical disc replacement (CDR) is a motion-preserving surgical procedure for treating patients with degenerative disorders. Numerous reports of first generation CDR "ball-and-socket" articulating devices have shown satisfactory clinical results. As a result, CDR devices have been safely implemented in the surgeon's armamentarium on a global scale. However, only minor design improvements have been made over the last few years, as first generation CDRs devices were based on traditional synovial joint arthroplasty designs. As a consequence, these articulating designs have limited resemblance to the complex kinematic behavior of a natural disc. This has driven the development of deformable viscoelastic CDR devices to better mimic the biomechanical behavior of a natural disc. As a result, several viscoelastic CDR devices have been developed in recent years that vary in terms of materials, design and clinical outcomes. Since these viscoelastic CDR devices are fairly new, their weaknesses and strengths, which are related to their design characteristics, have not been well described. Therefore, this literature review discusses design related advantages and disadvantages of deformable viscoelastic CDR devices. As such, this paper can provide insight for surgeons and engineers on specific design characteristics of several viscoelastic devices and could potentially help to develop and design future implants. Eleven viscoelastic CDR devices were identified. An extensive database search on the devices' tradenames in Medline and PubMed was performed next. The devices were categorized based on common design characteristics to give an overview of both category and device specific complications and advantages. Overall, literature shows that most of these viscoelastic CDR devices can provide motion in all six degrees-of-freedom and have a variable center of rotation. Nevertheless, the viscoelastic materials used do not have an extensive history in orthopedics, so the long-term material behavior in vivo is still unknown. Although the viscoelastic devices have common benefits and risks, each specific design and category also has its own design related advantages and drawbacks that are described in this review. Altogether, viscoelastic total disc replacements seem to be a promising option for the future of cervical arthroplasty, but long-term clinical outcome is needed to confirm the advantages of mimicking the viscoelasticity of a natural disc.


Assuntos
Disco Intervertebral , Substituição Total de Disco , Fenômenos Biomecânicos , Vértebras Cervicais/cirurgia , Humanos , Disco Intervertebral/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA