Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 48(3): 185-190, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38300512

RESUMO

Total morphine is an important urinary marker of heroin use but can also be present from prescriptions or poppy seed ingestion. In specimens with morphine concentrations consistent with poppy seed ingestion (<4,000 ng/mL), 6-acetylmorphine has served as an important marker of illicit drug use. However, as illicit fentanyl has become increasingly prevalent as a contaminant in the drug supply, fentanyl might be an alternative marker of illicit opioid use instead of or in combination with 6-acetylmorphine. The aim of this study was to quantify opiates, 6-acetylmorphine, fentanyl and fentanyl analogs in 504 morphine-positive (immunoassay 2,000 ng/mL cutoff) urine specimens from workplace drug testing. Almost half (43%) of morphine-positive specimens had morphine concentrations below 4,000 ng/mL, illustrating the need for markers to differentiate illicit drug use. In these specimens, fentanyl (22% co-positivity) was more prevalent than 6-acetylmorphine (12%). Co-positivity of 6-acetylmorphine and semi-synthetic opioids increased with morphine concentration, while fentanyl prevalence did not. In 110 fentanyl-positive specimens, the median norfentanyl concentration (1,520 ng/mL) was 9.6× higher than the median fentanyl concentration (159 ng/mL), illustrating the possibility of using norfentanyl as a urinary marker of fentanyl use. The only fentanyl analog identified was para-fluorofentanyl (n = 50), with results from most specimens consistent with para-fluorofentanyl contamination in illicit fentanyl. The results confirm the use of fentanyl by employees subject to workplace drug testing and highlight the potential of fentanyl and/or norfentanyl as important markers of illicit drug use.


Assuntos
Drogas Ilícitas , Transtornos Relacionados ao Uso de Opioides , Humanos , Entorpecentes , Morfina , Derivados da Morfina , Fentanila , Analgésicos Opioides , Transtornos Relacionados ao Uso de Opioides/diagnóstico , Transtornos Relacionados ao Uso de Opioides/epidemiologia , Local de Trabalho
2.
J Anal Toxicol ; 48(2): 81-98, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38217086

RESUMO

Products containing cannabidiol (CBD) have proliferated after the 2018 Farm Bill legalized hemp (cannabis with ≤0.3% delta-9-tetrahydrocannabinol (Δ9-THC)). CBD-containing topical products have surged in popularity, but controlled clinical studies on them are limited. This study characterized the effects of five commercially available hemp-derived high CBD/low Δ9-THC topical products. Healthy adults (N = 46) received one of six study drugs: a CBD-containing cream (N = 8), lotion (N = 8), patch (N = 7), balm (N = 8), gel (N = 6) or placebo (N = 9; matched to an active formulation). The protocol included three phases conducted over 17 days: (i) an acute drug application laboratory session, (ii) a 9-day outpatient phase with twice daily product application (visits occurred on Days 2, 3, 7 and 10) (iii) a 1-week washout phase. In each phase, whole blood, oral fluid and urine specimens were collected and analyzed via liquid chromatography with tandem mass spectrometry (LC-MS-MS) for CBD, Δ9-THC and primary metabolites of each and pharmacodynamic outcomes (subjective, cognitive/psychomotor and physiological effects) were assessed. Transdermal absorption of CBD was observed for three active products. On average, CBD/metabolite concentrations peaked after 7-10 days of product use and were highest for the lotion, which contained the most CBD and a permeation enhancer (vitamin E). Δ9-THC/metabolites were below the limit of detection in blood for all products, and no urine samples tested "positive" for cannabis using current US federal workplace drug testing criteria (immunoassay cut-off of 50 ng/mL and confirmatory LC-MS-MS cut-off of 15 ng/mL). Unexpectedly, nine participants (seven lotions, one patch and one gel) exhibited Δ9-THC oral fluid concentrations ≥2 ng/mL (current US federal workplace threshold for a "positive" test). Products did not produce discernable pharmacodynamic effects and were well-tolerated. This study provides important initial data on the acute/chronic effects of hemp-derived topical CBD products, but more research is needed given the diversity of products in this market.


Assuntos
Canabidiol , Cannabis , Alucinógenos , Adulto , Humanos , Cromatografia Líquida , Alimentos
3.
J Anal Toxicol ; 47(8): 719-725, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37697897

RESUMO

∆8-Tetrahydrocannabinol (∆8-THC) recently became widely available as an alternative to cannabis. ∆8-THC is likely impairing and poses a threat to workplace and traffic safety. In the present study, the prevalence of ∆8-THC in workplace drug testing was investigated by analyzing 1,504 urine specimens with a positive immunoassay cannabinoid initial test using a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method quantifying 15 cannabinoid analytes after hydrolysis. ∆8-tetrahydrocannabinol-9-carboxylic acid (∆8-THC-COOH) was detected in 378 urine specimens (15 ng/mL cutoff), compared to 1,144 specimens containing ∆9-THC-COOH. The data could be divided into three general groups. There were 964 (76%) ∆9-THC-COOH-dominant (<10% ∆8-THC-COOH) and 139 (11%) ∆8-THC-COOH-dominant (>90% ∆8-THC-COOH) specimens, with the remaining 164 (13%) specimens showing a mixture of both analytes (>90% ∆8-THC-COOH). Similar concentrations of ∆9-THC-COOH (median 187 ng/mL) and ∆8-THC-COOH (150 ng/mL) as the dominant species support the use of similar cutoffs and decision rules for both analytes. Apart from the carboxylic acid metabolites, 11-hydroxy-∆9-tetrahydrocannabinol (11-OH-∆9-THC, n = 1,282), ∆9-tetrahydrocannabivarin-9-carboxylic acid (∆9-THCV-COOH, n = 1,058), ∆9-THC (n = 746) and 7-hydroxy-cannabidiol (7-OH-CBD, n = 506) were the most prevalent analytes. Two specimens (0.13%) contained ≥140 ng/mL ∆9-THC without ∆9-THC-COOH, which could be due to genetic variability in the drug-metabolizing enzyme CYP2C9 or an adulterant targeting ∆9-THC-COOH. The cannabinoid immunoassay was repeated, and five specimens (0.33%) generated negative initial tests despite ∆9-THC-COOH concentrations of 54-1,000 ng/mL, potentially indicative of adulteration. The use of ∆8-THC is widespread in the US population, and all forensic laboratories should consider adding ∆8-THC and/or ∆8-THC-COOH to their scope of testing. Similar urinary concentrations were observed for both analytes, indicating that the decision rules used for ∆9-THC-COOH are also appropriate for ∆8-THC-COOH.


Assuntos
Canabidiol , Canabinoides , Alucinógenos , Dronabinol/metabolismo , Prevalência , Canabinoides/análise , Local de Trabalho
4.
J Anal Toxicol ; 46(8): 866-874, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-35260906

RESUMO

Given the recent popularity of cannabidiol (CBD) use and the emergence of ∆8-tetrahydrocannabinol (∆8-THC), the prevalence and concentrations of these and other cannabinoids were investigated in 2,000 regulated and 4,000 non-regulated specimens from workplace drug testing. All specimens were screened using liquid chromatography coupled to mass spectrometry (LC-MS-MS) for the presence of 7-hydroxy-CBD (7-OH-CBD) and ∆9-tetrahydrocannabinol-9-carboxylic acid (∆9-THC-COOH), with a cutoff of 2 ng/mL. Specimens screening positive by LC-MS-MS were analyzed by immunoassay at 20, 50 and 100 ng/mL cutoffs and by an LC-MS-MS confirmation method for 11 cannabinoids and metabolites with a 1 ng/mL cutoff. Using a 1 ng/mL cutoff, 98 (4.9%) regulated and 331 (8.3%) non-regulated specimens were positive for ∆9-THC-COOH. Of these, 64% had concentrations below 15 ng/mL. Similarly, 59 (3.0%) regulated and 162 (4.2%) non-regulated specimens were positive for 7-OH-CBD (n = 210), CBD (n = 120) and/or 7-carboxy-cannabidiol (CBD-COOH, n = 120). The median concentrations of 7-OH-CBD, CBD and CBD-COOH in those 221 specimens were 6.3, 1.1 and 1.2 ng/mL, respectively. ∆8-Tetrahydrocannabinol-9-carboxylic acid (∆8-THC-COOH) was identified in 76 (1.3%) specimens. Parent ∆8-THC is a minor cannabinoid in marijuana, which appears to account for the typically low ∆8-THC-COOH concentrations (median 3.4 ng/mL) in most positive specimens. However, elevated concentrations suggested the use of ∆8-THC-containing products in some cases (range 1.0-415 ng/mL). Although 93% agreement was observed between confirmatory LC-MS-MS (15 ng/mL cutoff) and immunoassay (50 ng/mL cutoff), a false-negative specimen (66 ng/mL ∆9-THC-COOH) was identified.


Assuntos
Canabidiol , Canabinoides , Canabinoides/análise , Ácidos Carboxílicos , Dronabinol/análise , Prevalência , Local de Trabalho
5.
J Air Waste Manag Assoc ; 66(9): 874-95, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27104336

RESUMO

UNLABELLED: An objective analysis is one of the main components of data assimilation. By combining observations with the output of a predictive model we combine the best features of each source of information: the complete spatial and temporal coverage provided by models, with a close representation of the truth provided by observations. The process of combining observations with a model output is called an analysis. To produce an analysis requires the knowledge of observation and model errors, as well as its spatial correlation. This paper is devoted to the development of methods of estimation of these error variances and the characteristic length-scale of the model error correlation for its operational use in the Canadian objective analysis system. We first argue in favor of using compact support correlation functions, and then introduce three estimation methods: the Hollingsworth-Lönnberg (HL) method in local and global form, the maximum likelihood method (ML), and the [Formula: see text] diagnostic method. We perform one-dimensional (1D) simulation studies where the error variance and true correlation length are known, and perform an estimation of both error variances and correlation length where both are non-uniform. We show that a local version of the HL method can capture accurately the error variances and correlation length at each observation site, provided that spatial variability is not too strong. However, the operational objective analysis requires only a single and globally valid correlation length. We examine whether any statistics of the local HL correlation lengths could be a useful estimate, or whether other global estimation methods such as by the global HL, ML, or [Formula: see text] should be used. We found in both 1D simulation and using real data that the ML method is able to capture physically significant aspects of the correlation length, while most other estimates give unphysical and larger length-scale values. IMPLICATIONS: This paper describes a proposed improvement of the objective analysis of surface pollutants at Environment and Climate Change Canada (formerly known as Environment Canada). Objective analyses are essentially surface maps of air pollutants that are obtained by combining observations with an air quality model output, and are thought to provide a complete and more accurate representation of the air quality. The highlight of this study is an analysis of methods to estimate the model (or background) error correlation length-scale. The error statistics are an important and critical component to the analysis scheme.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/análise , Mudança Climática , Monitoramento Ambiental/métodos , Modelos Teóricos , Canadá , Funções Verossimilhança , Análise Espaço-Temporal
6.
J Am Soc Mass Spectrom ; 22(8): 1472-6, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21953202

RESUMO

Loss of deuterium label during the LC step in amide hydrogen/deuterium exchange mass spectrometry (H/D-MS) is minimized by maintaining an acidic mobile phase pH and low temperature (pH 2.5, 0 °C). Here we detail the construction and performance of a low-cost, thermoelectrically refrigerated enclosure to house high-performance liquid chromatography (HPLC) components and cool mobile phases. Small volume heat exchangers rapidly decrease mobile phase temperature and keep the temperature stable to ±0.2 °C. Using a superficially porous reversed-phase column, we obtained excellent chromatographic performance in the separation of peptides with a median peak width of 4.4 s. Average deuterium recovery was 80.2% with an average relative precision of 0.91%.


Assuntos
Cromatografia de Fase Reversa/métodos , Medição da Troca de Deutério/métodos , Espectrometria de Massas/métodos , Refrigeração/instrumentação , Sequência de Aminoácidos , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa/instrumentação , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Dados de Sequência Molecular , Peptídeos/química , Temperatura
7.
Rapid Commun Mass Spectrom ; 24(1): 6-10, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19957295

RESUMO

The recent worldwide shortage of acetonitrile has prompted interest in alternative solvents for liquid chromatography/mass spectrometry (LC/MS). In this work, acetone was substituted for acetonitrile in the separation of a peptide mixture by reversed-phase high-performance liquid chromatography (RP-HPLC) and in the positive electrospray ionization mass spectrometry (ESI-MS) of individual peptides. On both C12 and C18 stationary phases, the substitution of acetone for acetonitrile as the organic component of the mobile phase did not alter the gradient elution order of a five-peptide retention standard, but did increase peak width, shorten retention times, and increase peak tailing. Positive ESI mass spectra were obtained for angiotensin I, bradykinin, [Leu(5)]-enkephalin, and somatostatin 14 dissolved in both acetonitrile/water/formic acid (25%/75%/0.1%) and acetone/water/formic acid (25%/75%/0.1%). Under optimized ESI-MS conditions, the mass spectral response of [Leu(5)]-enkephalin was increased two-fold when the solvent contained acetone. The substitution of acetone for acetonitrile resulted in only slight changes in the responses of the remaining peptides. A higher capillary voltage was required for optimum response when acetone was used. Compared with acetonitrile/water/formic acid (50/50/0.1%), more interfering species below m/z = 140 were found in the ESI-MS spectra of acetone/water/formic acid (50/50/0.1%).


Assuntos
Acetona/química , Acetonitrilas/química , Algoritmos , Cromatografia Líquida de Alta Pressão/métodos , Mapeamento de Peptídeos/métodos , Peptídeos/análise , Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA