Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 36(6): 4392-4400, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35075522

RESUMO

BACKGROUND: The placement of a self-expanding metal stent in patients with obstructive colon cancer is used as a bridge to surgery. However, due to a lack of consensus and insufficient data, the long-term oncologic outcomes after colonic SEMS placement remain unclear. We assessed the long-term oncologic outcomes and adverse effects of colonic stenting for malignant colonic obstruction. METHODS: We included 198 patients admitted to Korea University Anam Hospital between 2006 and 2014 for obstructive colon cancer, of whom 98 underwent SEMS placement as a bridge to surgery and 100 underwent direct surgery without stenting. The clinicopathologic characteristics, overall survival, and disease-free survival were compared. RESULTS: There were no significant differences in long-term oncologic outcomes between the two groups. The median follow-up durations were 61.55 and 58.64 months in the SEMS and DS groups, respectively. There were also no significant differences in the 5-year OS (77.4% vs. 74.2%, p = 0.691) and 5-year DFS (61.7% vs. 71.0%, p = 0.194) rates between the groups. However, the DS group had significantly more early postoperative complications (p = 0.002). CONCLUSIONS: Colonic SEMS deployment as a bridge to surgery did not negatively affect long-term oncologic outcomes when compared with DS. In addition, colonic stenting decreased early postoperative complications and reduced the time for patients to return to normal daily activities.


Assuntos
Neoplasias do Colo , Neoplasias Colorretais , Obstrução Intestinal , Neoplasias do Colo/complicações , Neoplasias do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Humanos , Obstrução Intestinal/etiologia , Obstrução Intestinal/patologia , Obstrução Intestinal/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
2.
Surg Endosc ; 35(10): 5836-5841, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34143290

RESUMO

BACKGROUND: Appropriate tissue tension and clear visibility of the dissection area using traction are essential for effective and safe endoscopic submucosal dissection (ESD). We developed a robotic assistive traction device for flexible endoscopy and compared its safety and efficiency in ESD between experienced and novice endoscopists. METHODS: Robotic ESD was performed by experienced and novice endoscopist groups (n = 2, each). The outcomes included time to complete each ESD step, total procedure time, size of the dissected mucosa, rate of en bloc resection, and major adverse events. Furthermore, incision and dissection speeds were compared between groups. RESULTS: Sixteen gastric lesions were resected from nine live pigs. The submucosal incision speed was significantly faster in the expert group than in the novice group (P = 0.002). There was no significant difference in the submucosal dissection speed between the groups (P = 0.365). No complications were reported in either group. CONCLUSIONS: When the robot was assisting in the ESD procedure, the dissection speed improved significantly, especially in the novice surgeons. Our robotic device can provide simple, effective, and safe multidirectional traction during ESD.


Assuntos
Ressecção Endoscópica de Mucosa , Robótica , Animais , Dissecação , Estudos de Viabilidade , Suínos , Tração
3.
Gut Liver ; 15(2): 217-224, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-32390408

RESUMO

BACKGROUND/AIMS: Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using a three-dimensional sensor and to evaluate the efficacy of the measured parameters. METHODS: Normal saline (0.9% NaCl), as a control, Eleview® (Poloxamer 188), Blue EyeTM (0.4% hyaluronic acid), and aqueous chitosan solution (2.0%) were injected into the submucosa of porcine stomachs ex vivo. The mucosal elevation height, elevated surface area, and angle of the tangent of the submucosal fluid cushion were measured using a three-dimensional sensor. The rates of change for each variable were calculated, and the correlation between parameters was analyzed. Tissue specimens were stained with hematoxylin and eosin. RESULTS: All variables exhibited the highest values under chitosan injection. The mucosal elevation height rate of change differed significantly between normal saline and chitosan solution (p=0.024). The elevated surface area rates of change for normal saline and Eleview® were significantly different from those for TS-905 and chitosan solution (p=0.006 and p=0.009, respectively). Further, height, area, and angle showed a positive correlation (p<0.001). A histological examination revealed an even distribution of aqueous chitosan within the submucosa without tissue damage. CONCLUSIONS: Aqueous chitosan was superior to normal saline and Eleview® and was noninferior to TS-905. A three-dimensional sensor and the measured parameters were effective and useful for evaluating the performance of submucosal fluids.


Assuntos
Quitosana , Mucosa Gástrica , Animais , Injeções , Poloxâmero , Suínos
4.
Gastroenterol Res Pract ; 2020: 9548171, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32190045

RESUMO

Patient compliance during bowel preparation is important for successful colonoscopy. Bowel preparation with polyethylene glycol (PEG), the most commonly used solution for cleansing, involves the unpleasant ingestion of a large amount of liquid. Sodium picosulfate magnesium citrate (SP-MC) solution is an alternative option with better palatability than PEG. Therefore, in this study, we compared the efficacy and patient tolerability among the following three bowel preparation protocols: 2 L PEG-ascorbic acid (ASc), 1 L PEG-ASc plus bisacodyl, and SP-MC 340 mL plus bisacodyl. We conducted a randomized prospective endoscopist-blinded study between August 2018 and January 2019. A total of 311 patients were randomly classified into three groups according to the above-described bowel preparation protocols. To evaluate the efficacy of bowel cleansing, we used the Boston Bowel Preparation Scale. The degree of symptoms and the patients' satisfaction with each bowel preparation method were investigated using a questionnaire completed before sedation for colonoscopy. The baseline characteristics were similar among the three groups. There was no significant difference in the bowel preparation quality among the three groups. However, the incidence of symptoms, such as abdominal fullness and pain, was significantly lower (P = 0.006 and 0.027, respectively) while the patients' satisfaction rate was significantly higher (P = 0.012) in the SP-MC plus bisacodyl group than in the two PEG groups. In this study, the efficacy of the SP-MC plus bisacodyl solution was similar to that of the PEG solutions. However, patient tolerability and satisfaction were better in the SP-MC plus bisacodyl group than in the other groups. In conclusion, the use of SP-MC plus bisacodyl bowel preparation solution might be a better method for providing good intestinal cleansing and improving patient compliance.

5.
J Nanosci Nanotechnol ; 18(3): 2128-2131, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448728

RESUMO

Diesel soot particles were sampled from 2-stroke and 4-stroke engines that burned two different fuels (Bunker A and C, respectively), and the effects of the engine and fuel types on the structural characteristics of the soot particle were analyzed. The carbon nanostructures of the sampled particles were characterized using various techniques. The results showed that the soot sample collected from the 4-stroke engine, which burned Bunker C, has a higher degree of order of the carbon nanostructure than the sample collected from the 2-stroke engine, which burned Bunker A. Furthermore, the difference in the exhaust gas temperatures originating from the different engine and fuel types can affect the nanostructure of the soot emitted from marine diesel engines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA