Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biomacromolecules ; 25(5): 2890-2901, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38683736

RESUMO

While adeno-associated virus is a leading vector for gene therapy, significant gaps remain in understanding AAV degradation and stability. In this work, we study the degradation of an engineered AAV serotype at physiological pH and ionic strength. Viral particles of varying fractions of encapsulated DNA were incubated between 30 and 60 °C, with changes in molecular weight measured by changes in total light scattering intensity at 90° over time. Mostly full vectors demonstrated a rapid decrease in molecular weight corresponding to the release of capsid DNA, followed by slow aggregation. In contrast, empty vectors demonstrated immediate, rapid colloid-type aggregation. Mixtures of full and empty capsids showed a pronounced decrease in initial aggregation that cannot be explained by a linear superposition of empty and full degradation scattering signatures, indicating interactions between capsids and ejected DNA that influenced aggregation mechanisms. This demonstrates key interactions between AAV capsids and their cargo that influence capsid degradation, aggregation, and DNA release mechanisms in a physiological solution.


Assuntos
Capsídeo , DNA Viral , Dependovirus , Dependovirus/genética , Dependovirus/química , Capsídeo/química , Capsídeo/metabolismo , Cinética , DNA Viral/química , Humanos , Vetores Genéticos/química , Vetores Genéticos/metabolismo , Proteínas do Capsídeo/química , Proteínas do Capsídeo/metabolismo , Concentração de Íons de Hidrogênio
2.
Vaccine ; 41(9): 1589-1601, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36732163

RESUMO

A key aspect to vaccine efficacy is formulation stability. Biochemical evaluations provide information on optimal compositions or thermal stability but are routinely validated by ex vivo analysis and not efficacy in animal models. Here we assessed formulations identified to improve or reduce stability of the mucosal adjuvant dmLT being investigated in polio and enterotoxigenic E. coli (ETEC) clinical vaccines. We observed biochemical changes to dmLT protein with formulation or thermal stress, including aggregation or subunit dissociation or alternatively resistance against these changes with specific buffer compositions. However, upon injection or mucosal vaccination with ETEC fimbriae adhesin proteins or inactivated polio virus, experimental findings indicated immunization route and co-administered antigen impacted vaccine immunogenicity more so than dmLT formulation stability (or instability). These results indicate the importance of both biochemical and vaccine-derived immunity assessment in formulation optimization. In addition, these studies have implications for use of dmLT in clinical settings and for delivery in resource poor settings.


Assuntos
Escherichia coli Enterotoxigênica , Infecções por Escherichia coli , Proteínas de Escherichia coli , Vacinas contra Escherichia coli , Poliomielite , Animais , Enterotoxinas , Excipientes , Escherichia coli , Infecções por Escherichia coli/prevenção & controle , Adjuvantes Imunológicos , Antígenos
3.
Rev Sci Instrum ; 89(11): 113109, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501347

RESUMO

A simple, effective light scattering prototype sensitive to both polarized and depolarized scattering was constructed, and its performance was tested on a variety of pure liquids and optically isotropic and anisotropic polymer solutions and colloidal suspensions. The results, performance, and means to further improvement are reported here. Because of its simplicity and low cost, many identical units can be produced to construct a simultaneous multiple sample light scattering platform that can be used to monitor polymer and colloid solution stability, phase changes, aggregation, degradation, etc. Measurable depolarization was found for a variety of organic liquids and suspensions of both polyfluoroethylene and latex spheres. No detectable depolarization was found for various polymers.

4.
J Phys Chem B ; 122(40): 9361-9372, 2018 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-30226382

RESUMO

Is aggregation kinetics for a protein under given conditions reproducible? Is aggregation inherently deterministic, stochastic, or even chaotic? Because protein aggregation in ex vivo formulations is complex, with many origins and manifestations, the question of aggregation reproducibility for a given protein, formulation, and stressor is of both fundamental and practical significance. This work concerns temperature-induced and contact-stir-induced aggregation of bovine serum albumin (BSA) and a monoclonal antibody (mAbX). It assesses reproducibility via early-stage aggregation rates (ARs) from light scattering. "Global stressors" affect the entire protein population, for example, temperature. "Local stressors" affect only a partial population at a given instant, for example, stirring. The instrumental error distribution (IED) allows stochasticity to be identified for AR distributions (ARDs) broader than IED. For ARD at the limit of the IED, the behavior is "minimally stochastic" or "operationally deterministic." A stochastic index is defined in terms of the ratio of the standard deviation (SD) of log(AR) data and the SD of IED. Thermal aggregation was operationally deterministic for BSA and mAbX, although significant lot-to-lot variations for BSA were found. ARD from contact-stir-stress was stochastic for BSA and mAb. Despite this, log(AR) decreases logarithmically with rpm. These trends may hold for other global and local stressors.


Assuntos
Anticorpos Monoclonais/metabolismo , Soroalbumina Bovina/metabolismo , Animais , Anticorpos Monoclonais/química , Bovinos , Calefação , Cinética , Luz , Agregados Proteicos , Multimerização Proteica , Estabilidade Proteica , Reprodutibilidade dos Testes , Espalhamento de Radiação , Soroalbumina Bovina/química , Processos Estocásticos , Temperatura
5.
Appl Occup Environ Hyg ; 17(7): 491-4, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12083169

RESUMO

Exposure of workers to diisocyanates in the polyurethane foam manufacturing industry is well documented. However, very little quantitative data have been published on exposure to diisocyanates from the use of paints and coatings. The purpose of this study was to evaluate emission of 2,4-toluene diisocyanate, 2,6-toluene diisocyanate (2,6-TDI), and isophorone diisocyanate from a commercially available two-stage concrete coating and sealant. A laboratory model of an outdoor deck coating process was developed and diisocyanate concentrations determined by derivatization with 1-(2-methoxyphenol)-piperazine and subsequent high performance liquid chromatographic analysis with UV detection. The detection limit for 2,4-toluene diisocyanate and 2,6-toluene diisocyanate urea derivatives was 0.6 microg TDI/gm wet product, and 0.54 microg IPDI/gm wet product for the isophorone diisocyanate urea derivative. No 2,4-toluene diisocyanate or isophorone diisocyanate was detected in the mixed product. A maximum mean 2,6-TDI emission rate of 0.32 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 1-hour sampling time, 0.38 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 5-hour sampling time, and 0.02 micrpg of 2,6-TDI/gram of wet product applied/hour was observed for the 15-hour sampling time. The decrease in rate of 2,6-TDI emission over the 15-hour period indicates that emission of 2,6-TDI is virtually complete after 5 hours. These emission rates should allow industrial hygienists to calculate exposures to isocyanates emitted from at least one curing sealant.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Pintura/análise , Tolueno 2,4-Di-Isocianato/análise , Indústria Química , Humanos , Saúde Ocupacional , Estudos de Amostragem , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA