Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
JCI Insight ; 8(4)2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36602878

RESUMO

Although murine models of coronary atherosclerotic disease have been used extensively to determine mechanisms, limited new therapeutic options have emerged. Pigs with familial hypercholesterolemia (FH pigs) develop complex coronary atheromas that are almost identical to human lesions. We reported previously that insulin-like growth factor 1 (IGF-1) reduced aortic atherosclerosis and promoted features of stable plaque in a murine model. We administered human recombinant IGF-1 or saline (control) in atherosclerotic FH pigs for 6 months. IGF-1 decreased relative coronary atheroma in vivo (intravascular ultrasound) and reduced lesion cross-sectional area (postmortem histology). IGF-1 increased plaque's fibrous cap thickness, and reduced necrotic core, macrophage content, and cell apoptosis, consistent with promotion of a stable plaque phenotype. IGF-1 reduced circulating triglycerides, markers of systemic oxidative stress, and CXCL12 chemokine levels. We used spatial transcriptomics (ST) to identify global transcriptome changes in advanced plaque compartments and to obtain mechanistic insights into IGF-1 effects. ST analysis showed that IGF-1 suppressed FOS/FOSB factors and gene expression of MMP9 and CXCL14 in plaque macrophages, suggesting possible involvement of these molecules in IGF-1's effect on atherosclerosis. Thus, IGF-1 reduced coronary plaque burden and promoted features of stable plaque in a pig model, providing support for consideration of clinical trials.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Hiperlipoproteinemia Tipo II , Placa Aterosclerótica , Camundongos , Humanos , Animais , Suínos , Fator de Crescimento Insulin-Like I/metabolismo , Aterosclerose/patologia , Placa Aterosclerótica/patologia
2.
Curr Cardiol Rev ; 19(1): e170322202296, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35301953

RESUMO

Patients with posterior circulation ischemia due to vertebral artery stenosis account for 20 to 25% of ischemic strokes and have an increased risk of recurrent stroke. In patients treated with medical therapy alone, the risk of recurrence is particularly increased in the first few weeks after symptoms occur, with an annual stroke rate of 10 to 15%. Additionally, obstructive disease of the vertebrobasilar system carries a worse prognosis, with a 30% mortality at 2-years if managed medically without additional surgical or endovascular intervention. Percutaneous transluminal angioplasty and stenting of symptomatic vertebral artery stenosis are promising options widely used in clinical practice with good technical results; however, the improved clinical outcome has been examined in various clinical trials without a sufficient sample size to conclusively determine whether stenting is better than medical therapy. Surgical revascularization is an alternative approach for the treatment of symptomatic vertebral artery stenosis that carries a 10-20% mortality rate. Despite the advances in medical therapy and endovascular and surgical options, symptomatic vertebral artery stenosis continues to impose a high risk of stroke recurrence with associated high morbidity and mortality. This review aims to provide a focused update on the percutaneous treatment of vertebral artery stenosis, its appropriate diagnostic approach, and advances in medical therapies.


Assuntos
Acidente Vascular Cerebral , Insuficiência Vertebrobasilar , Humanos , Artéria Vertebral/diagnóstico por imagem , Insuficiência Vertebrobasilar/diagnóstico , Insuficiência Vertebrobasilar/terapia , Insuficiência Vertebrobasilar/complicações , Angioplastia/efeitos adversos , Angioplastia/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , Resultado do Tratamento , Stents
3.
Curr Probl Cardiol ; 47(9): 101266, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35644503

RESUMO

Left atrial appendage (LAA) occlusion devices provided an acceptable and valid alternative to anticoagulation among patients with atrial fibrillation who carry high bleeding risk. Watchman device is non-inferior to oral anticoagulation to prevent cerebrovascular accidents. The presence of a longer distal portion of the older generation Watchman led to exclusion of patients with prohibitive anatomy of the LAA such as chicken-wing morphology or shallow LAA. Watchman FLX provides a wider range of sizes and can be implanted with complex anatomy or shallow LAA. In the case series, we discuss 3 patients with challenging LAA anatomy that underwent successful Watchman FLX implantation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Anticoagulantes , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Humanos , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
4.
Sci Adv ; 6(3): eaax7467, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31998838

RESUMO

Our nearest neighbor, Proxima Centauri, hosts a temperate terrestrial planet. We detected in radial velocities evidence of a possible second planet with minimum mass m c sin i c = 5.8 ± 1.9M ⊕ and orbital period P c = 5.21 - 0.22 + 0.26 years. The analysis of photometric data and spectro-scopic activity diagnostics does not explain the signal in terms of a stellar activity cycle, but follow-up is required in the coming years for confirming its planetary origin. We show that the existence of the planet can be ascertained, and its true mass can be determined with high accuracy, by combining Gaia astrometry and radial velocities. Proxima c could become a prime target for follow-up and characterization with next-generation direct imaging instrumentation due to the large maximum angular separation of ~1 arc second from the parent star. The candidate planet represents a challenge for the models of super-Earth formation and evolution.

5.
Nature ; 536(7617): 437-40, 2016 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-27558064

RESUMO

At a distance of 1.295 parsecs, the red dwarf Proxima Centauri (α Centauri C, GL 551, HIP 70890 or simply Proxima) is the Sun's closest stellar neighbour and one of the best-studied low-mass stars. It has an effective temperature of only around 3,050 kelvin, a luminosity of 0.15 per cent of that of the Sun, a measured radius of 14 per cent of the radius of the Sun and a mass of about 12 per cent of the mass of the Sun. Although Proxima is considered a moderately active star, its rotation period is about 83 days (ref. 3) and its quiescent activity levels and X-ray luminosity are comparable to those of the Sun. Here we report observations that reveal the presence of a small planet with a minimum mass of about 1.3 Earth masses orbiting Proxima with a period of approximately 11.2 days at a semi-major-axis distance of around 0.05 astronomical units. Its equilibrium temperature is within the range where water could be liquid on its surface.


Assuntos
Planetas , Astros Celestes , Meio Ambiente Extraterreno/química , Rotação , Temperatura , Água/análise , Água/química
6.
J Interv Cardiol ; 28(3): 288-95, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25989717

RESUMO

BACKGROUND: Hemodialysis (HD) access failure is a common cause of increased morbidity and healthcare cost in patients with end stage renal disease (ESRD). Percutaneous balloon angioplasty has been used to treat hemodialysis access stenosis but is complicated by a high rate of restenosis. Percutaneous cutting balloon (PCB) angioplasty is an alternative approach that has shown to reduce restenosis. OBJECTIVES: The aim of the study is to assess the safety and efficacy of PCB angioplasty in comparison with conventional and high-pressure balloon angioplasty in the treatment of hemodialysis access site stenosis. METHODS: We searched PubMed, EMBASE and the Cochrane Central register of controlled trials (CENTRAL) databases through August 2014 and selected studies using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist. We included all randomized clinical trials with a head-to-head comparison between PCB and conventional or high-pressure balloon angioplasty RESULTS: Three studies with 1034 participants (age 60.7 (±12.9) years and 50.1% males) with 525 in PCB and 509 in control arm were included in the analysis. The immediate procedural success rate was not significantly different in the PCB angioplasty and control arm respectively, (87.2% vs. 83.7% RD -0.02; 95%CI -0.06 to 0.01; P = 0.38). The six-month target lesion patency was significantly higher in the PCB angioplasty arm (67.2% vs. 55.6% RD 0.12; 95%CI 0.05-0.19; P < 0.05) with number needed to treat (NNT) of 9. The device related complications were not statistically significant between groups (RD 0.03; 95%CI -0.02 to 0.07; P = 0.26). CONCLUSIONS: PCB angioplasty is effective in treatment of hemodialysis access stenosis, with significantly higher six-month patency compared to balloon angioplasty.


Assuntos
Angioplastia com Balão/métodos , Derivação Arteriovenosa Cirúrgica , Constrição Patológica/terapia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Grau de Desobstrução Vascular
7.
Philos Trans A Math Phys Eng Sci ; 372(2014): 20130088, 2014 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-24664922

RESUMO

Our current view of exoplanets is one derived primarily from solar-like stars with a strong focus on understanding our Solar System. Our knowledge about the properties of exoplanets around the dominant stellar population by number, the so-called low-mass stars or M dwarfs, is much more cursory. Based on radial velocity discoveries, we find that the semi-major axis distribution of M dwarf planets appears to be broadly similar to those around more massive stars and thus formation and migration processes might be similar to heavier stars. However, we find that the mass of M dwarf planets is relatively much lower than the expected mass dependency based on stellar mass and thus infer that planet formation efficiency around low-mass stars is relatively impaired. We consider techniques to overcome the practical issue of obtaining good quality radial velocity data for M dwarfs despite their faintness and sustained activity and emphasize (i) the wavelength sensitivity of radial velocity signals, (ii) the combination of radial velocity data from different experiments for robust detection of small amplitude signals, and (iii) the selection of targets and radial velocity interpretation of late-type M dwarfs should consider Hα behaviour.

8.
Catheter Cardiovasc Interv ; 79(6): 921-6, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21542122

RESUMO

BACKGROUND: Pharmacokinetic data suggests that the intravenous form of n-acetylcysteine (NAC) may be more effective than the oral formulation in preventing contrast induced nephropathy (CIN). NAC owing to its anti-oxidant properties might be beneficial for patients with acute coronary syndromes (ACS) who are at increased risk for CIN. The aim of this prospective randomized, single-center, double-blind, placebo controlled trial (NCT00939913) was to assess the effect of high-dose intravenous NAC on CIN in ACS patients undergoing coronary angiography and/or percutaneous coronary intervention (PCI). METHODS: We randomized 398 ACS patients scheduled for diagnostic angiography ± PCI to an intravenous regimen of high-dose NAC (1,200 mg bolus followed by 200 mg/hr for 24 hr; n = 206) or placebo (n = 192). The primary end-point was incidence of CIN defined as an increase in serum creatinine concentration ≥ 25% above the baseline level within 72 hr of the administration of intravenous contrast. RESULTS: There was no difference found for the primary end point with CIN in 16% of the NAC group and in 13% of the placebo group (p = 0.40). Change in serum cystatin-C, a sensitive marker for renal function, was 0.046 ± 0.204 in the NAC group and 0.002 ± 0.260 in the control group (p = 0.07). CONCLUSION: In ACS patients undergoing angiography ± PCI, high-dose intravenous NAC failed to reduce the incidence of CIN.


Assuntos
Acetilcisteína/administração & dosagem , Síndrome Coronariana Aguda/diagnóstico por imagem , Angioplastia Coronária com Balão , Antioxidantes/administração & dosagem , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Nefropatias/prevenção & controle , Síndrome Coronariana Aguda/terapia , Idoso , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Creatinina/sangue , Cistatina C/sangue , Método Duplo-Cego , Feminino , Humanos , Infusões Intravenosas , Nefropatias/sangue , Nefropatias/induzido quimicamente , Nefropatias/diagnóstico , Masculino , Pessoa de Meia-Idade , Nova Orleans , Placebos , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA