Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Stereotact Funct Neurosurg ; 88(5): 281-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20588079

RESUMO

BACKGROUND: Previous studies have shown that closed-loop or responsive neurostimulation can abort induced or spontaneous epileptiform discharges. OBJECTIVE: To assess the effectiveness of a programmable cranially implanted closed-loop neurostimulation system in the control of seizures originating from an area relatively inaccessible by open craniotomy. METHOD: A patient with drug-resistant partial epilepsy had previously undergone open resection of the left frontal opercular cortex and the underlying insular area. Although subdural-depth electrode ictal recordings had been nonlocalizing, depth electrode insular stimulation had produced the patient's habitual aura. Postoperatively, there was a sustained 50% reduction in seizure frequency. The residual seizures were identical to the preoperative seizures. Repeat depth electrode monitoring revealed that the ictal focus was immediately posterior to the previously resected insular area. A closed-loop cranial internal pulse generator system including left anterior insular and posterior orbitofrontal depth electrodes was implanted. RESULT: There was an additional 60% reduction of seizures. CONCLUSION: Preliminary observation indicates that responsive neurostimulation may be an effective alternative to higher-risk resective epilepsy surgery.


Assuntos
Córtex Cerebral/cirurgia , Terapia por Estimulação Elétrica , Epilepsias Parciais/terapia , Adulto , Eletroencefalografia , Humanos , Neuroestimuladores Implantáveis , Masculino , Exame Neurológico , Testes Neuropsicológicos , Resultado do Tratamento
2.
Neurosurg Focus ; 23(6): E8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18081485

RESUMO

OBJECT: Stereotactic radiosurgery (SRS) with the Gamma Knife (GK) is a rapidly emerging surgical modality in the management of medically refractory idiopathic trigeminal neuralgia (TN). The current study examines the long-term outcome in patients with drug-resistant idiopathic TN who underwent GK surgery at the authors' institution. METHODS: One hundred and six consecutive patients (38 men and 68 women) with proven medically refractory idiopathic TN were included in this retrospective study. Their ages were 41-82 years (mean 72.3 years). All patients underwent SRS with prescribed maximal radiation doses ranging from 70 to 85 Gy. Isocenters 1-3 were used and plugging was used selectively. The follow-up period was 12-72 months (mean 34.3 months). The patients were divided into 2 groups according to their history of previous surgery. RESULTS: The initial response rate in patients with no history of previous surgery was 92.9%; in those who had undergone previous surgery, the initial response rate was 85.7%. At the end of the 1st posttreatment year, an excellent outcome was achieved in 82.5% of patients who had not had previous surgery, and in 69.4% of those who had. The respective outcome rates for the 2nd posttreatment year were 78 and 63.5%, respectively. The most common complication was the development of persistent paresthesia, which occurred in 15.8% of patients with no previous surgery and 16.3% of those with previous surgery. CONCLUSIONS: Stereotactic radiosurgery with the GK is a safe and effective treatment option for patients with medically refractory idiopathic TN.


Assuntos
Radiocirurgia/métodos , Resultado do Tratamento , Neuralgia do Trigêmeo/radioterapia , Neuralgia do Trigêmeo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Estudos Retrospectivos
3.
Epilepsy Behav ; 8(3): 534-41, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16546450

RESUMO

As part of their evaluation for epilepsy surgery, 53 patients underwent stimulation of depth or subdural electrodes. Responses obtained from depth stimulation included motor responses at 34 sites, sensory responses at 114 sites, language alterations at 6 sites, and affective responses at 22 sites. Responses obtained from subdural stimulation included motor responses at 19 sites, sensory responses at 31 sites, speech alterations at 10 sites, and affective responses at 1 site. Of 23 affective responses, 21 were dysphoric responses of fear, a sense of dying, or unpleasantness with or without some type of experiential phenomenon. Dysphoric responses were statistically associated (P=0.01) with right-sided stimulation (N=18) as compared with left-sided stimulation (N=3) of mesial frontal, orbitofrontal, mesial temporal, and insular stimulation sites. Two euphoric responses occurred, one with left-sided and one with right-sided stimulation. No affective responses were obtained with convexity or neocortical stimulation.


Assuntos
Estimulação Elétrica , Emoções , Epilepsia do Lobo Temporal/fisiopatologia , Lateralidade Funcional , Convulsões/patologia , Adolescente , Adulto , Criança , Eletrodos Implantados , Epilepsia do Lobo Temporal/psicologia , Epilepsia do Lobo Temporal/cirurgia , Euforia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Radiocirurgia , Estudos Retrospectivos
5.
Stereotact Funct Neurosurg ; 83(4): 153-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16205108

RESUMO

Open-loop stimulation studies have shown varying control of seizures with stimulation of different anatomical targets. A recent multi-institutional clinical study utilizing an external closed-loop stimulation system had promising results. A novel implantable closed-loop Responsive Neurostimulation System (RNS) (Neuropace, Inc., Mountainview, Calif., USA) consisting of a cranially implanted pulse generator, one or two quadripolar subdural strip or depth leads and a programmer is under testing in a prospective clinical trial. The RNS pulse generator continuously analyzes the patient's electrocortigrams (ECoGs) and automatically triggers electrical stimulation when specific ECoG characteristics programmed by the clinician, as indicative of electrographic seizures or precursor of epileptiform activities, are detected. The pulse generator then stores diagnostic information detailing detections and stimulations, including multichannel stored ECoGs. The RNS programmer communicates transcutaneously with the implanted pulse generator when initiated by a clinician. The RNS programmer can download diagnostics and store ECoGs for review. The RNS programmer can then be used to program detection and stimulation parameters. In our current communication, we describe the selection criteria for implanting this system, the preparation of the surgical candidates as well as the surgical technique. We also present our preliminary results with 8 patients who had an RNS implanted. Seven patients (87.5%) had more than 45% decrease in their seizure frequency. The mean follow-up time in our series was 9.2 months. The implantation of a closed-loop stimulation system, in our experience, represents a safe and relatively simple surgical procedure. However, the efficacy of this new treatment modality remains to be determined in further multi-institutional, prospective clinical studies.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Eletrodos Implantados , Epilepsias Parciais/terapia , Adulto , Craniotomia , Eletroencefalografia/instrumentação , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Armazenamento e Recuperação da Informação , Masculino , Seleção de Pacientes , Resultado do Tratamento
6.
Neurosurg Focus ; 19(3): E10, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-16190600

RESUMO

Several cases of congenital or acquired temporal encephaloceles have been reported in the literature as the causative mechanism of simple and/or complex partial seizures. In this report the authors describe a rare case of spontaneous parietal encephalocele presenting with simple partial seizures and progressively increasing contralateral upper-extremity motor deficit. The unusual anatomical location of an encephalocele associated with seizures and the delayed seizure onset represent distinctive characteristics in this case. Preoperative imaging included surface electroencephalography, computerized tomography, and brain magnetic resonance imaging. Frameless neuronavigation and intraoperative cortical mapping were used to aid resection of the encephalocele, and the dural and bone defects were reconstructed. The surgical outcome in this case was excellent, and the patient has remained seizure free. The pertinent literature is reviewed in this report.


Assuntos
Encefalocele/complicações , Epilepsias Parciais/etiologia , Córtex Motor/anormalidades , Progressão da Doença , Encefalocele/diagnóstico , Encefalocele/cirurgia , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Córtex Motor/patologia , Córtex Motor/cirurgia , Neuronavegação/métodos , Neurocirurgia/métodos , Literatura de Revisão como Assunto , Tomografia Computadorizada por Raios X
7.
Stereotact Funct Neurosurg ; 82(4): 165-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15528955

RESUMO

The implantation of subdural electrodes has been widely employed in the invasive monitoring of patients with medically refractory epilepsy. The use of subdural electrodes, though, has been associated with rare but occasionally troublesome complications. We report the occurrence of nonhabitual seizures after implanting subdural grid electrodes. Among 57 patients diagnosed with medically refractory epilepsy who were evaluated in our department over a 12-month period, 21 patients underwent craniotomy for subdural grid/strip electrode implantation. Subdural grids and strips (AdTech, Racine, Wisc., USA) were used for continuous video EEG monitoring. In 3 patients, during subdural monitoring, consistent nonhabitual seizure activity was recorded. This was both clinically and electrographically different than the patients' habitual seizures. The patients' nonhabitual seizures disappeared postoperatively after removing the implanted electrodes. The occurrence of nonhabitual seizures, though quite rare, could lead to mislocalization of an epileptogenic focus. This complication might be the result of direct mechanical cortical irritation or chemical irritation caused by blood breakdown products. The occurrence of nonhabitual seizures comes to add itself to the existing list of complications associated with employment of subdural electrodes for invasive monitoring.


Assuntos
Eletrodos Implantados/efeitos adversos , Epilepsia , Adulto , Craniotomia , Erros de Diagnóstico , Epilepsia/diagnóstico , Epilepsia/etiologia , Epilepsia/cirurgia , Feminino , Hematoma/complicações , Hematoma/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Espaço Subdural
8.
Stereotact Funct Neurosurg ; 82(5-6): 230-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15637444

RESUMO

INTRODUCTION: Medically refractory pain related to cancer is a major indication for pain surgery. Stereotactic mesencephalic tractotomy (SMT) constitutes a widely accepted procedure in treating unilateral head and neck cancer pain. MATERIAL AND METHOD: We report a case of a MRI-based right-sided SMT for treating intractable craniofacial pain, in a 38-year-old patient, related to a previously resected adenocystic carcinoma of the parotid gland. The patient had undergone an implantation of an intrathecal morphine/clonidine pump and subsequent radiofrequency cingulotomy with only temporary improvement. Prior to SMT the patient developed left-sided chest wall pain, secondary to metastasis, in addition to her left-sided facial, dysesthetic pain. The MRI-based SMT was performed with the assistance of a side-extruding monopolar electrode (Leibinger GmbH, Freiburg, Germany) for intraoperative, topographic mapping of the spinothalamic tract. Two lesions were made at 8 and 5 mm off the midline on the right side at the level of the superior colliculus at 70 degrees C for 90 s with a 2 x 4 mm radiofrequency bipolar electrode (Leibinger GmbH). RESULTS: The patient developed intraoperatively left-sided facial, bodily and extremity thermoanalgesia. She had an unremarkable postoperative course. No early proprioceptive or gaze deficits were noted. Her facial and truncal pain was well controlled with intrathecal morphine and clonidine at the preoperative dosology for 17 months. Left-sided upper extremity dysesthesia developed 15 months after the procedure. The patient expired 18 months after this procedure due to an extensive metastatic disease. CONCLUSIONS: The use of high-resolution MRI (MPRAGE) and side-extruding electrode represent technical maneuvers that could decrease the morbidity and further improve the long-term outcome of SMT in treating patients with chronic, medically refractory cancer pain, who have a likely survival time in the order of 1 year +/- 6 months.


Assuntos
Imageamento por Ressonância Magnética/métodos , Mesencéfalo/cirurgia , Técnicas Estereotáxicas , Adulto , Dor Facial/diagnóstico , Dor Facial/etiologia , Dor Facial/cirurgia , Feminino , Humanos , Mesencéfalo/patologia , Dor Intratável/diagnóstico , Dor Intratável/etiologia , Dor Intratável/cirurgia , Neoplasias Parotídeas/complicações
9.
Stereotact Funct Neurosurg ; 80(1-4): 14-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14745202

RESUMO

Magnetic source imaging (MSI) of interictal epileptiform dipoles was studied in 100 epilepsy surgery candidates. Sixty underwent surgery. MSI epileptiform data were classified as focal, regional, multifocal, scattered or none. Resections of MSI epileptiform foci were classified as extensive (EXT) versus partial or none (P/N). MSI interictal epileptiform dipoles were found in 22 of 27 anterior temporal (ATL) cases, and in 31 of 33 extratemporal (XMT) cases. Of 10 EXT ATL cases, 5 (50%) were seizure free (SF). Of 12 P/N ATL cases, 7 (58%) were SF. Of 10 nonlesional EXT XMT resections, 8 (80%) were SF. Of 10 nonlesional P/N XMT resections, 1 (10%) was SF. Neither focality of MSI data or spatial agreement of electrographic and MSI data significantly affected outcomes.


Assuntos
Epilepsia/diagnóstico , Epilepsia/cirurgia , Magnetoencefalografia , Cirurgia Assistida por Computador , Humanos , Procedimentos Neurocirúrgicos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA