Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
J Am Heart Assoc ; 11(5): e022238, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35195012

RESUMO

Background In patients with out-of-hospital cardiac arrest without ST-segment elevation, immediate coronary angiography did not improve clinical outcomes when compared with delayed angiography in the COACT (Coronary Angiography After Cardiac Arrest) trial. Whether 1 of the 2 strategies has benefits in terms of health care resource use and costs is currently unknown. We assess the health care resource use and costs in patients with out-of-hospital cardiac arrest. Methods and Results A total of 538 patients were randomly assigned to a strategy of either immediate or delayed coronary angiography. Detailed health care resource use and cost-prices were collected from the initial hospital episode. A generalized linear model and a gamma distribution were performed. Generic quality of life was measured with the RAND-36 and collected at 12-month follow-up. Overall total mean costs were similar between both groups (EUR 33 575±19 612 versus EUR 33 880±21 044; P=0.86). Generalized linear model: (ß, 0.991; 95% CI, 0.894-1.099; P=0.86). Mean procedural costs (coronary angiography and percutaneous coronary intervention, coronary artery bypass graft) were higher in the immediate angiography group (EUR 4384±3447 versus EUR 3028±4220; P<0.001). Costs concerning intensive care unit and ward stay did not show any significant difference. The RAND-36 questionnaire did not differ between both groups. Conclusions The mean total costs between patients with out-of-hospital cardiac arrest randomly assigned to an immediate angiography or a delayed invasive strategy were similar during the initial hospital stay. With respect to the higher invasive procedure costs in the immediate group, a strategy awaiting neurological recovery followed by coronary angiography and planned revascularization may be considered. Registration URL: https://trialregister.nl; Unique identifier: NL4857.


Assuntos
Parada Cardíaca Extra-Hospitalar , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Custos e Análise de Custo , Humanos , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Parada Cardíaca Extra-Hospitalar/terapia , Qualidade de Vida , Resultado do Tratamento
2.
Crit Care Med ; 50(2): e129-e142, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34637414

RESUMO

OBJECTIVES: The optimal targeted temperature in patients with shockable rhythm is unclear, and current guidelines recommend targeted temperature management with a correspondingly wide range between 32°C and 36°C. Our aim was to study survival and neurologic outcome associated with targeted temperature management strategy in postarrest patients with initial shockable rhythm. DESIGN: Observational substudy of the Coronary Angiography after Cardiac Arrest without ST-segment Elevation trial. SETTING: Nineteen hospitals in The Netherlands. PATIENTS: The Coronary Angiography after Cardiac Arrest trial randomized successfully resuscitated patients with shockable rhythm and absence of ST-segment elevation to a strategy of immediate or delayed coronary angiography. In this substudy, 459 patients treated with mild therapeutic hypothermia (32.0-34.0°C) or targeted normothermia (36.0-37.0°C) were included. Allocation to targeted temperature management strategy was at the discretion of the physician. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: After 90 days, 171 patients (63.6%) in the mild therapeutic hypothermia group and 129 (67.9%) in the targeted normothermia group were alive (hazard ratio, 0.86 [95% CI, 0.62-1.18]; log-rank p = 0.35; adjusted odds ratio, 0.89; 95% CI, 0.45-1.72). Patients in the mild therapeutic hypothermia group had longer ICU stay (4 d [3-7 d] vs 3 d [2-5 d]; ratio of geometric means, 1.32; 95% CI, 1.15-1.51), lower blood pressures, higher lactate levels, and increased need for inotropic support. Cerebral Performance Category scores at ICU discharge and 90-day follow-up and patient-reported Mental and Physical Health Scores at 1 year were similar in the two groups. CONCLUSIONS: In the context of out-of-hospital cardiac arrest with shockable rhythm and no ST-elevation, treatment with mild therapeutic hypothermia was not associated with improved 90-day survival compared with targeted normothermia. Neurologic outcomes at 90 days as well as patient-reported Mental and Physical Health Scores at 1 year did not differ between the groups.


Assuntos
Angiografia Coronária/métodos , Cardioversão Elétrica/estatística & dados numéricos , Hipotermia Induzida/normas , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Angiografia Coronária/estatística & dados numéricos , Feminino , Humanos , Hipotermia Induzida/métodos , Hipotermia Induzida/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Países Baixos , Parada Cardíaca Extra-Hospitalar/epidemiologia , Ressuscitação/métodos , Ressuscitação/estatística & dados numéricos , Resultado do Tratamento
3.
Resuscitation ; 164: 93-100, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33932485

RESUMO

BACKGROUND: The effect of immediate coronary angiography and percutaneous coronary intervention (PCI) in patients who are successfully resuscitated after cardiac arrest in the absence of ST-segment elevation myocardial infarction (STEMI) on left ventricular function is currently unknown. METHODS: This prespecified sub-study of a multicentre trial evaluated 552 patients, successfully resuscitated from out-of-hospital cardiac arrest without signs of STEMI. Patients were randomized to either undergo immediate coronary angiography or delayed coronary angiography, after neurologic recovery. All patients underwent PCI if indicated. The main outcomes of this analysis were left ventricular ejection fraction and end-diastolic and systolic volumes assessed by cardiac magnetic resonance imaging or echocardiography. RESULTS: Data on left ventricular function was available for 397 patients. The mean (± standard deviation) left ventricular ejection fraction was 45.2% (±12.8) in the immediate angiography group and 48.4% (±13.2) in the delayed angiography group (mean difference: -3.19; 95% confidence interval [CI], -6.75 to 0.37). Median left ventricular end-diastolic volume was 177 ml in the immediate angiography group compared to 169 ml in the delayed angiography group (ratio of geometric means: 1.06; 95% CI, 0.95-1.19). In addition, mean left ventricular end-systolic volume was 90 ml in the immediate angiography group compared to 78 ml in the delayed angiography group (ratio of geometric means: 1.13; 95% CI 0.97-1.32). CONCLUSION: In patients successfully resuscitated after out-of-hospital cardiac arrest and without signs of STEMI, immediate coronary angiography was not found to improve left ventricular dimensions or function compared with a delayed angiography strategy. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register number, NTR4973.


Assuntos
Parada Cardíaca Extra-Hospitalar , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Países Baixos , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Parada Cardíaca Extra-Hospitalar/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
4.
Catheter Cardiovasc Interv ; 98(2): E188-E196, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33694294

RESUMO

OBJECTIVES: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents. BACKGROUND: In patients presenting with acute MI, higher adverse event rates have been reported. So far, no clinical results >1 year have been published of acute MI patients treated with Resolute Onyx. METHODS: This post-hoc analysis of the randomized BIONYX trial(NCT02508714) assessed the main outcome target vessel failure (TVF: cardiac death, target vessel MI, or target vessel revascularization) with Kaplan-Meier methods. RESULTS: Of all 2,488 trial participants, acute MI patients (n = 1,275[51.2%]) were significantly younger and had less comorbidities than non-MI patients (n = 1,213[48.8%]). TVF rates were lower in acute MI patients (77/1,275[6.1%] vs. 103/1,213[8.6%], HR:0.70, 95%-CI 0.52-0.94; plog-rank  = 0.02), mainly driven by target vessel revascularization (4.1 vs. 6.1%, plog-rank  = 0.03). Multivariate analysis showed no independent association of clinical syndrome with TVF (adjusted-HR: 0.81, 95%-CI 0.60-1.10; p = .17). In MI patients treated with Resolute Onyx (n = 626) versus Orsiro (n = 649), there was no difference in TVF (6.2 vs. 6.1%; plog-rank  = 0.97) and its components. There was only 1(0.2%) definite-or-probable stent thrombosis in RO-ZES and 8(1.2%) in O-SES (p = .053). CONCLUSIONS: Two years after treatment with thin-strut DES in this randomized trial, patients treated for acute MI had lower adverse event rates than non-MI patients. Yet, these findings were mainly attributable to between-group differences in patient and lesion characteristics. In patients who underwent PCI for acute MI, both Resolute Onyx and Orsiro showed favorable and similar 2-year outcomes.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Everolimo , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
5.
Int J Cardiol ; 325: 37-44, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148427

RESUMO

BACKGROUND: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES). METHODS: We performed two prespecified secondary analyses of two randomized DES trials, which both stratified for diabetes. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. Follow-up was finished before the COVID-19 pandemic. RESULTS: In BIO-RESORT, 624/3514 (17.8%) had diabetes: 211 received Orsiro sirolimus-eluting stents (SES), 203 Synergy everolimus-eluting stents (EES), and 210 Resolute Integrity zotarolimus-eluting stents (RI-ZES). TVF did not differ between SES (10.2%) and EES (10.0%) versus RI-ZES (12.7%) (SES vs. RI-ZES HR:0.78, 95%-CI [0.44-1.40]; p = 0.40, EES vs. RI-ZES HR:0.79, 95%-CI [0.44-1.40]; p = 0.42). In BIONYX, 510/2488 (20.5%) patients had diabetes: 250 received SES and 260 Resolute Onyx zotarolimus-eluting stents (RO-ZES). There was no difference in TVF between SES (10.7%) versus RO-ZES (12.2%) (HR:0.88, 95%-CI [0.52-1.48]; p = 0.63). CONCLUSIONS: There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Stents Farmacológicos , Everolimo/administração & dosagem , Sirolimo/análogos & derivados , Plásticos Biodegradáveis , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Sirolimo/administração & dosagem
6.
Resuscitation ; 158: 14-22, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33189807

RESUMO

BACKGROUND: Whether sex is associated with outcomes of out-of-hospital cardiac arrest (OHCA) is unclear. OBJECTIVES: This study examined sex differences in survival in patients with OHCA without ST-segment elevation myocardial infarction (STEMI). METHODS: Using data from the randomized controlled Coronary Angiography after Cardiac Arrest (COACT) trial, the primary point of interest was sex differences in OHCA-related one-year survival. Secondary points of interest included the benefit of immediate coronary angiography compared to delayed angiography until after neurologic recovery, angiographic and clinical outcomes. RESULTS: In total, 522 patients (79.1% men) were included. Overall one-year survival was 59.6% in women and 63.4% in men (HR 1.18; 95% CI: 0.76-1.81;p = 0.47). No cardiovascular risk factors were found that modified survival. Women less often had significant coronary artery disease (CAD) (37.0% vs. 71.3%;p < 0.001), but when present, they had a worse prognosis than women without CAD (HR 3.06; 95% CI 1.31-7.19;p = 0.01). This was not the case for men (HR 1.05; 95% CI 0.67-1.65;p = 0.83). In both sexes, immediate coronary angiography did not improve one-year survival compared to delayed angiography (women, odds ratio (OR) 0.87; 95% CI 0.58-1.30;p = 0.49; vs. men, OR 0.97; 95% CI 0.45-2.09;p = 0.93). CONCLUSION: In OHCA patients without STEMI, we found no sex differences in overall one-year survival. Women less often had significant CAD, but when CAD was present they had worse survival than women without CAD. This was not the case for men. Both sexes did not benefit from a strategy of immediate coronary angiography as compared to delayed strategy with respect to one-year survival. CLINICAL TRIAL REGISTRATION NUMBER: Netherlands trial register (NTR) 4973.


Assuntos
Parada Cardíaca Extra-Hospitalar , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Angiografia Coronária , Feminino , Humanos , Masculino , Países Baixos/epidemiologia , Parada Cardíaca Extra-Hospitalar/terapia , Caracteres Sexuais
7.
Data Brief ; 33: 106521, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33294518

RESUMO

Sex differences in out-of-hospital cardiac arrest (OHCA) patients are increasingly recognized. Although it has been found that post-resuscitated women are less likely to have significant coronary artery disease (CAD) than men, data on follow-up in these patients are limited. Data for this data in brief article was obtained as a part of the randomized controlled Coronary Angiography after Cardiac Arrest without ST-segment elevation (COACT) trial. The data supplements the manuscript "Sex differences in out-of-hospital cardiac arrest patients without ST-segment elevation: A COACT trial substudy" were it was found that women were less likely to have significant CAD including chronic total occlusions, and had worse survival when CAD was present. The dataset presented in this paper describes sex differences on interventions, implantable-cardioverter defibrillator (ICD) shocks and hospitalizations due to heart failure during one-year follow-up in patients successfully resuscitated after OHCA. Data was derived through a telephone interview at one year with the patient or general practitioner. Patients in this randomized dataset reflects a homogenous study population, which can be valuable to further build on research regarding long-term sex differences and to further improve cardiac care.

8.
JAMA Cardiol ; 5(12): 1358-1365, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32876654

RESUMO

Importance: Ischemic heart disease is a common cause of cardiac arrest. However, randomized data on long-term clinical outcomes of immediate coronary angiography and percutaneous coronary intervention (PCI) in patients successfully resuscitated from cardiac arrest in the absence of ST segment elevation myocardial infarction (STEMI) are lacking. Objective: To determine whether immediate coronary angiography improves clinical outcomes at 1 year in patients after cardiac arrest without signs of STEMI, compared with a delayed coronary angiography strategy. Design, Setting, and Participants: A prespecified analysis of a multicenter, open-label, randomized clinical trial evaluated 552 patients who were enrolled in 19 Dutch centers between January 8, 2015, and July 17, 2018. The study included patients who experienced out-of-hospital cardiac arrest with a shockable rhythm who were successfully resuscitated without signs of STEMI. Follow-up was performed at 1 year. Data were analyzed, using the intention-to-treat principle, between August 29 and October 10, 2019. Interventions: Immediate coronary angiography and PCI if indicated or coronary angiography and PCI if indicated, delayed until after neurologic recovery. Main Outcomes and Measures: Survival, myocardial infarction, revascularization, implantable cardiac defibrillator shock, quality of life, hospitalization for heart failure, and the composite of death or myocardial infarction or revascularization after 1 year. Results: At 1 year, data on 522 of 552 patients (94.6%) were available for analysis. Of these patients, 413 were men (79.1%); mean (SD) age was 65.4 (12.3) years. A total of 162 of 264 patients (61.4%) in the immediate angiography group and 165 of 258 patients (64.0%) in the delayed angiography group were alive (odds ratio, 0.90; 95% CI, 0.63-1.28). The composite end point of death, myocardial infarction, or repeated revascularization since the index hospitalization was met in 112 patients (42.9%) in the immediate group and 104 patients (40.6%) in the delayed group (odds ratio, 1.10; 95% CI, 0.77-1.56). No significant differences between the groups were observed for the other outcomes at 1-year follow-up. For example, the rate of ICD shocks was 20.4% in the immediate group and 16.2% in the delayed group (odds ratio, 1.32; 95% CI, 0.66-2.64). Conclusions and Relevance: In this trial of patients successfully resuscitated after out-of-hospital cardiac arrest and without signs of STEMI, a strategy of immediate angiography was not found to be superior to a strategy of delayed angiography with respect to clinical outcomes at 1 year. Coronary angiography in this patient group can therefore be delayed until after neurologic recovery without affecting outcomes. Trial Registration: trialregister.nl Identifier: NTR4973.


Assuntos
Angiografia Coronária , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/terapia , Ressuscitação , Infarto do Miocárdio com Supradesnível do Segmento ST , Fatores de Tempo , Resultado do Tratamento
9.
Am Heart J ; 228: 109-115, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32882569

RESUMO

BACKGROUND: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80 years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, P = .04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, P < .001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, P = .88) and repeat target vessel revascularization (1.9% vs 2.8%, P = .16). In multivariate analyses, age ≥ 80 years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, P < .001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (n = 459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, P < .001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.


Assuntos
Stents Farmacológicos/classificação , Everolimo/farmacologia , Infarto do Miocárdio , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Risco Ajustado/métodos , Fatores de Risco , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 13(9): 1100-1109, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32381186

RESUMO

OBJECTIVES: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis. BACKGROUND: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates. METHODS: A total of 2,488 all-comer patients were treated at 7 coronary intervention centers in Belgium, Israel, and the Netherlands. The main endpoint, TVF, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (clinically indicated target vessel revascularization). Two-year follow-up data were analyzed using Kaplan-Meier methods. RESULTS: Two-year follow-up data were available for 2,460 of 2,488 patients (98.9%). TVF occurred in 93 of 1,243 patients (7.6%) assigned to ZES versus 87 of 1,245 patients (7.1%) assigned to SES (log-rank p = 0.66). There was no significant between-stent difference in individual components of this endpoint. The incidence of definite-or-probable stent thrombosis was low for both treatment arms (0.4% vs. 1.1%; log-rank p = 0.057). In patients stented in small vessels, there was no between-stent difference (TVF 8.2% vs. 8.7% [log-rank p = 0.75], target lesion revascularization 4.0% vs. 4.4% [log-rank p = 0.77]). CONCLUSIONS: At 2-year follow-up, the novel thin composite-wire-strut durable-polymer Resolute Onyx ZES showed in all-comers similar safety and efficacy compared with the ultrathin cobalt-chromium-strut biodegradable-polymer Orsiro SES. The analysis of patients who were treated in small vessels also suggested no advantage for either stent.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
11.
Circ Cardiovasc Interv ; 13(6): e008737, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32466676

RESUMO

BACKGROUND: Numerous randomized clinical trials have demonstrated the superiority of thin-strut biodegradable polymer second-generation drug-eluting stent to the first-generation drug-eluting stent and the noninferiority to the thin-strut second-generation permanent polymer drug-eluting stent. Data on long-term clinical outcomes with a novel ultrathin drug-eluting stent, to date, are limited. METHODS: The DESSOLVE III trial (Multicenter Randomized Study of the MiStent Sirolimus Eluting Absorbable Polymer Stent System for Revascularization of Coronary Arteries; n=1398) is a prospective, multicenter, single-blinded, all-comers, randomized controlled trial (NCT02385279), allocating in a 1:1 ratio to either ultrathin-strut biodegradable polymer MiStent sirolimus-eluting stent or to thin-strut permanent polymer Xience everolimus-eluting stent. The primary end point was device-oriented composite end point, defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. The secondary end point was patient-oriented composite end point, defined as the composite of all-cause mortality, any myocardial infarction, or any revascularization. RESULTS: At 3 years, follow-up data were available in 1381 patients (98.8%). The primary end point of device-oriented composite end point occurred in 10.5% for MiStent sirolimus-eluting stent and in 11.5% for Xience everolimus-eluting stent (P=0.55). Rates of cardiac death (3.9% versus 3.8%; P=0.88), target vessel myocardial infarction (3.2% versus 2.5%; P=0.43), and clinically indicated target lesion revascularization (5.2% versus 6.5%; P=0.30) did not differ significantly between the 2 devices. The rate of definite or probable stent thrombosis was infrequent and similar between the 2 arms (1.2% versus 1.5%; P=0.64). The 90-day landmark analysis showed no significant difference in device-oriented composite end point between the 2 groups after polymer degradation of MiStent. The risk of patient-oriented composite end point was comparable between the 2 groups (22.7% versus 22.9%; P=0.34). CONCLUSIONS: In the DESSOLVE III trial, early safety and efficacy with MiStent sirolimus-eluting bioabsorbable polymer-coated stent are confirmed at a longer term follow-up when compared with Xience everolimus-eluting permanent polymer-coated stent in a large all-comers population. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02385279.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Everolimo/administração & dosagem , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Idoso , Fármacos Cardiovasculares/efeitos adversos , Europa (Continente) , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 13(7): 808-816, 2020 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-32171714

RESUMO

OBJECTIVES: This study sought to assess 2-year clinical outcome following percutaneous coronary intervention (PCI) with thin-strut new-generation drug-eluting stents (DES) in patients treated in proximal left anterior descending artery (P-LAD) versus non-P-LAD lesions. BACKGROUND: In current revascularization guidelines, P-LAD coronary artery stenosis is discussed separately, mainly because of a higher adverse event risk and benefits of bypass surgery. METHODS: The study included 6,037 patients without previous bypass surgery or left main stem involvement from the TWENTE I, II, and III randomized trials. A total of 1,607 (26.6%) patients had at least 1 DES implanted in P-LAD and were compared with 4,430 (73.4%) patients who were exclusively treated in other (non-P-LAD) segments. RESULTS: Two-year follow-up was available in 5,995 (99.3%) patients. At baseline, P-LAD patients had more multivessel treatment and longer total stent length. The rate of the patient-oriented composite clinical endpoint (any death, any myocardial infarction, or any revascularization) was similar in P-LAD versus non-P-LAD patients (11.4% vs. 11.6%; p = 0.87). In P-LAD patients, the rate of the device-oriented composite clinical endpoint (cardiac death, target vessel myocardial infarction, or target lesion revascularization) was higher (7.6% vs. 6.0%; p = 0.020), driven by a higher rate of target vessel myocardial infarction (4.1% vs. 2.6%; p = 0.002). However, multivariate analysis showed no independent association between stenting P-LAD lesions and clinical endpoints. CONCLUSIONS: In this patient-level pooled analysis of 3 large-scale contemporary DES trials, treatment of P-LAD lesions was not independently associated with higher 2-year adverse clinical event rates. These results imply that separate consideration in future revascularization guidelines may not be mandatory any longer.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 96(2): E142-E148, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31696618

RESUMO

OBJECTIVES: To assess long-term safety and efficacy of the Xposition S self-apposing stent in the treatment of unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Percutaneous intervention with stents has emerged as a valid alternative to surgical revascularization to treat ULMCA disease. Conventional balloon-expandable stents face technical challenges, particularly in large left main diameter requiring extensive optimization and side branch access in distal bifurcation. Xposition S allows for optimal apposition, bridging diameter differences, and allows expansion to vessel diameters up to 6.0 mm. METHODS: Between June 2016 and July 2017, 205 patients were enrolled in this international, prospective, multicenter registry. Patients with SYNTAX score ≥ 33 or recent STEMI were excluded. IVUS during procedure was performed in a prespecified subgroup of 50 patients. The primary clinical endpoint was 12 months Target lesion failure (TLF) and the primary efficacy endpoint was angiographic success. RESULTS: Distal left main bifurcation was involved in 92.7%, treated with provisional approach in most cases (79.4%). TLF rate at 12 months was 8.3%, which was defined as a composite of cardiac death (2.0%), target-vessel MI (2.9%), and TLR (5.4%). Most revascularizations occurred at SB ostium. IVUS analysis demonstrated optimal stent apposition with only one reported malapposition and promising poststenting minimal stent area measures. CONCLUSIONS: The TRUNC study confirms that Xposition S self-apposing stent is a valid and feasible option for the treatment of ULMCA disease. Such results were reached without the systematic need of stent optimisation techniques, focusing mainly on lesion treatment.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Stents Metálicos Autoexpansíveis , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
14.
N Engl J Med ; 380(15): 1397-1407, 2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30883057

RESUMO

BACKGROUND: Ischemic heart disease is a major cause of out-of-hospital cardiac arrest. The role of immediate coronary angiography and percutaneous coronary intervention (PCI) in the treatment of patients who have been successfully resuscitated after cardiac arrest in the absence of ST-segment elevation myocardial infarction (STEMI) remains uncertain. METHODS: In this multicenter trial, we randomly assigned 552 patients who had cardiac arrest without signs of STEMI to undergo immediate coronary angiography or coronary angiography that was delayed until after neurologic recovery. All patients underwent PCI if indicated. The primary end point was survival at 90 days. Secondary end points included survival at 90 days with good cerebral performance or mild or moderate disability, myocardial injury, duration of catecholamine support, markers of shock, recurrence of ventricular tachycardia, duration of mechanical ventilation, major bleeding, occurrence of acute kidney injury, need for renal-replacement therapy, time to target temperature, and neurologic status at discharge from the intensive care unit. RESULTS: At 90 days, 176 of 273 patients (64.5%) in the immediate angiography group and 178 of 265 patients (67.2%) in the delayed angiography group were alive (odds ratio, 0.89; 95% confidence interval [CI], 0.62 to 1.27; P = 0.51). The median time to target temperature was 5.4 hours in the immediate angiography group and 4.7 hours in the delayed angiography group (ratio of geometric means, 1.19; 95% CI, 1.04 to 1.36). No significant differences between the groups were found in the remaining secondary end points. CONCLUSIONS: Among patients who had been successfully resuscitated after out-of-hospital cardiac arrest and had no signs of STEMI, a strategy of immediate angiography was not found to be better than a strategy of delayed angiography with respect to overall survival at 90 days. (Funded by the Netherlands Heart Institute and others; COACT Netherlands Trial Register number, NTR4973.).


Assuntos
Angiografia Coronária , Eletrocardiografia , Cardiopatias/diagnóstico por imagem , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Intervenção Coronária Percutânea , Tempo para o Tratamento , Idoso , Feminino , Cardiopatias/complicações , Cardiopatias/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/terapia
15.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-30253879

RESUMO

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
16.
Am Heart J ; 198: 25-32, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29653644

RESUMO

AIM: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. METHODS AND RESULTS: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel-related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. CONCLUSIONS: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States.


Assuntos
Implantes Absorvíveis , Estenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Internacionalidade , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Polímeros , Estudos Prospectivos , Medição de Risco , Método Simples-Cego , Sirolimo/farmacologia , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 11(5): 462-469, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29519378

RESUMO

OBJECTIVES: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts). BACKGROUND: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices. METHODS: In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated. RESULTS: Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; plog-rank = 0.62) and its individual components: cardiac death (4.5% vs. 4.9%; plog-rank = 0.69), target vessel-related myocardial infarction (3.1% vs. 2.6%; plog-rank = 0.47), and target vessel revascularization (7.6% vs. 8.6%; plog-rank = 0.46). The 5-year incidence of definite or probable stent thrombosis was similar (1.5% vs. 1.3%; plog-rank = 0.83). CONCLUSIONS: At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
18.
Lancet ; 391(10119): 431-440, 2018 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-29203070

RESUMO

BACKGROUND: MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. METHODS: We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. FINDINGS: Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45 patients (6·5%) in the everolimus-eluting stent group (absolute difference -0·8% [95% CI -3·3 to 1·8], pnon-inferiority=0·0001). Procedural complications occurred in 12 patients (1·7%) in the sirolimus-eluting stent group and ten patients (1·4%) in the everolimus-eluting stent group; no clinical adverse events could be attributed to these dislodgements through a minimum of 12 months of follow-up. The rate of stent thrombosis, a safety indicator, did not differ between groups and was low in both treatment groups. INTERPRETATION: The sirolimus-eluting bioabsorbable polymer stent was non-inferior to the everolimus-eluting durable polymer stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. MiStent seems a reasonable alternative to other stents in clinical practice. FUNDING: The European Cardiovascular Research Institute, Micell Technologies (Durham, NC, USA), and Stentys (Paris, France).


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Implantes Absorvíveis , Idoso , Feminino , Humanos , Masculino , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
19.
Cardiology ; 137(4): 207-217, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28445871

RESUMO

OBJECTIVE: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES). METHODS: We therefore assessed 3-year follow-up data of high-risk versus low- to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES. Patients were categorized as "high-risk" if they met ≥1 of the following criteria: (1) diabetes (17.9%); (2) previous myocardial infarction (21.9%); (3) previous coronary revascularization (25.8%); (4) chronic renal failure (3.5%); (5) left ventricular ejection fraction ≤30% (1.5%); and (6) age ≥75 years (17.3%). RESULTS: At the 3-year follow-up, the incidence of the composite endpoint target vessel failure (TVF) (13.2 vs. 7.5%; logrank p < 0.001) and 2 of its components - cardiac death (4.7 vs. 1.5%; logrank p < 0.001) and target vessel revascularization (7.3 vs. 4.7%; logrank p = 0.03) - was higher in high-risk (n = 957) versus low- to intermediate-risk patients (n = 854). Among high-risk patients, treatment with Resolute Integrity (n = 481) and Promus Element stents (n = 476) was similarly safe and efficacious (TVF: 13.3 vs. 13.1%; logrank p = 0.95; definite-or-probable stent thrombosis: 1.7 vs. 1.7%; logrank p = 1.00). CONCLUSIONS: The newer-generation Resolute Integrity and Promus Element stents showed similar results in terms of safety and efficacy for treating high-risk patients, who had significantly higher event rates than patients with low-to-intermediate risk.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Trombose/etiologia , Resultado do Tratamento
20.
EuroIntervention ; 12(17): 2128-2131, 2017 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27916746

RESUMO

AIMS: The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers. METHODS AND RESULTS: In the randomised, multicentre, investigator-initiated DUTCH PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction or target vessel revascularisation. Adverse clinical events were independently adjudicated. Three-year follow-up data were obtained in 1,807 patients (99.8%, four withdrawals). Both the ZES and EES groups showed favourable outcomes with a similar incidence of TVF (10.7% vs. 10.3%; pLog-rank=0.77) and the individual components thereof: cardiac death (3.2% vs. 3.1%; pLog-rank=0.87), target vessel-related myocardial infarction (2.8% vs. 2.2%; pLog-rank=0.44) and target vessel revascularisation (6.0% vs. 6.2%; pLog-rank=0.87). In addition, the incidence of definite or probable stent thrombosis was similar for patients treated with ZES versus EES (1.4% vs. 1.1%; pLog-rank=0.66). CONCLUSIONS: The safety and efficacy of treating all-comers with newer-generation Resolute Integrity and PROMUS Element stents was found to be extended up to three years.


Assuntos
Stents Farmacológicos/estatística & dados numéricos , Intervenção Coronária Percutânea/instrumentação , Seguimentos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA