Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pediatr Surg Int ; 40(1): 86, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512596

RESUMO

OBJECTIVE: Loop ligation of the appendix is a challenging surgical skill and well suited to be trained in a simulator. We aimed to develop an affordable and easy-to-build simulator and test its training effect. DESIGN AND PARTICIPANTS: Different materials were tested, and the best training modality was identified by researching the literature. The developed simulator training was tested on 20 surgical novices. RESULTS: A video was produced including an instruction on how to build the simulator and a step-by-step tuition on how to ligate the appendix. The Peyton approach was utilized to guide learners. Training with the simulator leads to reliable skill acquisition. All participants improved significantly in completing the task successfully during the structured learning. CONCLUSION: We succeeded in developing a simulator for loop ligation of the appendix during laparoscopic appendectomy. Participants significantly improve in handling the loops. The transferability of the skill learned during simulation to the operating room will be subject of a follow-up study.


Assuntos
Laparoscopia , Treinamento por Simulação , Humanos , Seguimentos , Apendicectomia , Laparoscopia/educação , Simulação por Computador , Competência Clínica
2.
J Pediatr Urol ; 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38402079

RESUMO

INTRODUCTION: Teaching methods in hypospadias repair are still traditional. Available simulators often lack authenticity in terms of haptic feedback and realistic tissue handling. OBJECTIVE: Our aim was to develop a high-fidelity, easily reproducible, and affordable animal tissue model for the advanced surgical simulation of hypospadias repair with realistic haptic feedback and tissue handling. MATERIAL AND METHODS: A regular-sized chicken leg and a lamb tenderloin are used to assess the feasibility of simulating hypospadias correction by using the example of a Snodgrass Tubularized Incised Plate-Repair. The model preparation is incorporated into the training process. RESULTS: A detailed description of the high-fidelity model is provided. All steps of a hypospadias repair can be trained while providing realistic anatomy, adequate size, and multilayer tissue properties. Haptic conditions highly resemble human tissue properties. Fine tissue handling corresponds to intraoperative conditions. Limitations to this surgical model apply as in other animal tissue models. CONCLUSION: We developed a high-fidelity, easily reproducible, and affordable hypospadias animal tissue model. Due to the multilayer animal tissue properties, this model provides realistic haptic feedback and thus an inexpensive and reproducible model for hypospadias simulation. External validation is mandatory prior to implementation into urological training.

4.
J Pediatr Surg ; 58(10): 1916-1920, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36935227

RESUMO

PURPOSE: To provide a high-fidelity, animal tissue-based model for the advanced surgical simulation of a Posterior Sagittal Anorectoplasty (PSARP) for rectovestibular fistula in anorectal malformation (ARM). MATERIALS AND METHODS: A chicken cadaver was used to assess the feasibility of simulating a PSARP for rectovestibular fistula in ARM. No modification was required to implement the surgical simulation. RESULTS: A detailed description of the high-fidelity surgical simulation model is provided. The PSARP can be simulated while providing realistic anatomy (e.g. common wall between rectovestibular fistula and vagina), adequate rectal size, location and placement of the rectovestibular fistula, and proximity to the vagina. Haptic conditions of the tissue resemble human tissue and operative conditions as well. DISCUSSION: Concerning the decreased exposure of index cases of pediatric surgical trainees and pediatric surgeons in practice, simulation-based training can provide means to acquire or maintain the necessary skills to perform complex surgical procedures [1-5] Surgical simulation models for ARM are limited. Few low-cost trainers are available with predominant artificial and mostly unrealistic tissue [6-8] Animal models have the advantage of realistic multilayer tissue haptic feedback [6]. CONCLUSION: We provide a low-cost, high-fidelity model for correcting a rectovestibular fistula in a child with ARM, a complex operative procedure with low incidence but high-stake outcomes. The described tissue model utilizing the chicken cloaca anatomy provides a high-fidelity model for operative correction of rectovestibular ARM. For simulation purposes in the treatment of ARM, this model appears to be promising in terms of providing realistic pathology and haptic feedback in pediatric dimensions. LEVEL OF EVIDENCE: V.


Assuntos
Malformações Anorretais , Procedimentos de Cirurgia Plástica , Fístula Retal , Feminino , Criança , Humanos , Lactente , Estudos Retrospectivos , Reto/cirurgia , Reto/anormalidades , Fístula Retal/cirurgia , Malformações Anorretais/cirurgia , Canal Anal/cirurgia , Canal Anal/anormalidades , Fístula Retovaginal/cirurgia
5.
European J Pediatr Surg Rep ; 10(1): e152-e155, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36388429

RESUMO

Simple renal cysts are a scarce entity in pediatric patients and their etiology is unknown in most cases. Usually, they are monitored with ultrasound and regular follow-up of renal function. Surgical treatment is rarely indicated. We report the case of a newborn with a single giant renal cyst that could be treated successfully with drainage and sclerotherapy. Single giant renal cysts require careful investigation and monitoring. In cysts without communication to the pelvico-caliceal system, sclerotherapy by instillation of doxycycline is a therapeutic option.

6.
Children (Basel) ; 9(7)2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35884046

RESUMO

Radiation exposure early in life is associated with greater incidences of malignancy. Our goal was to quantify radiation exposure in shunt-treated hydrocephalus patients and study changes in the diagnostic modalities used. A single-center, retrospective analysis was performed, and 41 children treated for hydrocephalus using an adjustable ventriculoperitoneal shunt were identified. Diagnostics associated with hydrocephalus and other comorbidities were analyzed and radiation exposure was calculated. During 330.09 total shunt years, patients were exposed to a mean hydrocephalus-associated radiation dose of 3.93 mSv (range: 0-24.38 mSv), which amounted to a mean rate of 0.49 mSv per shunt year, respectively. Radiation exposure was greatest after shunt insertion in the first year of life. A continuous change from CT scans to MRIs could be seen over the study period, such that patients who underwent shunt insertion after 2017 were not exposed to additional hydrocephalus-associated radiation during their first year of life. Nevertheless, our patients, and a few individuals especially, seemed to be at higher risk for radiation sequelae. Our results suggest that CT scans should be substituted with MRIs, which decrease overall radiation exposure and can lead to zero additional radiation exposure during the first year of life after shunt insertion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA