Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Curr Med Sci ; 43(3): 609-614, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37115402

RESUMO

OBJECTIVE: In this study, we aimed to assess the characteristics of the P3 component from an event-related potential (ERP) that was induced by visual acuity (VA) processing. Furthermore, we sought to provide electrophysiological evidence for the objective evaluation of VA. METHODS: We recruited 32 participants with myopia-related ametropia. They reported no other ocular diseases and had an uncorrected VA of 4.0 in both eyes. We used the block letter "E" at different visual angles and orientations as the graphic stimuli. The oddball paradigm, consisting of 4 modules, was used for ERP analysis. The standard stimuli of each module were identical, with a visual angle of 1°15'. The visual angles of the target stimuli were 1°15', 55', 24', and 15'. The VA test was performed on each eye separately for all participants, and all characteristics of the P3 component were analyzed. RESULTS: There was no significant difference in the P3 peak letencies between the target stimulation angle 1°15' group and the 55' group, or between the target stimulation angle 24' group and the 15' group. There was a significant difference in the P3 peak letencies between the target stimulation angle 1°15' group and the 24' group as well as the 15' group. There was a significant difference in the P3 peak letencies between the target stimulation angle 55' group and the 24' group as well as the 15' group. No significant differences were observed in the P3 amplitude between modules. CONCLUSION: In the oddball paradigm, P3 elicitation indicated a cognitive response to the target stimuli. These data showed that the characteristics of P3 can be used as an objective evaluation of VA.


Assuntos
Potenciais Evocados , Erros de Refração , Humanos , Potenciais Evocados/fisiologia , Acuidade Visual , Visão Ocular , Olho
2.
Curr Med Sci ; 43(1): 184-190, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36544037

RESUMO

OBJECTIVE: Y-Chromosomal short tandem repeat polymorphism (Y-STR) analysis plays an indispensable role in the identification of male individuals, population genetics, and biogeographic research. While profiles of many populations based on Y-STR markers in human genomes are ample, haplotype data for the Wuwei Han are still scarce. METHODS: In this study, 2180 unrelated Wuwei Han male individuals residing in Gansu Province, China were collected and genotyped using the novel Microreader™ 40Y Plus ID system. Phylogenetic relationship reconstructions, multidimensional scaling (MDS), and heatmap analysis were performed based on the genetic distance (Rst) values between our studied population and other populations of the Ymax module in the Y-STR Haplotype Reference Database (YHRD). RESULTS: A total of 2129 unique haplotypes were obtained, and the haplotype diversity (HD) and discrimination capacity (DC) for the Wuwei Han were 0.9999 and 0.9931, respectively. CONCLUSION: Our results demonstrate that the Wuwei Han population had intimate genetic relationships with East Asians, especially the geographically close Han populations. Overall, this Y-Chromosomal assay gives valuable information about paternal lineages in male individual tracking and genealogical database construction.


Assuntos
Cromossomos Humanos Y , Etnicidade , Humanos , Masculino , Haplótipos , Filogenia , Etnicidade/genética , Repetições de Microssatélites , China
3.
Fa Yi Xue Za Zhi ; 38(3): 355-359, 2022 Jun 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-36221830

RESUMO

OBJECTIVES: To analyze the Nogo-P3 component of event-related potential (ERP) in the process of visual acuity processing, to provide electrophysiological evidence for objective evaluation of visual acuity. METHODS: Twenty-six subjects with no other ocular diseases except for ametropia were recruited, and all subjects had uncorrected visual acuity both eyes 1/10 (evaluated using Monoyer chart). Block letter E with different visual angles and directions were used as graphic stimuli. The Go/Nogo paradigm was used for ERP studies. The visual angle of Go stimulation angle was 1°15', Nogo stimuli were 1°15', 55', 24' and 15'. The visual acuity test was performed on each of the two naked eyes separately in all subjects, and the characteristics of the Nogo-P3 component were analyzed. RESULTS: The latency of Nogo-P3 showed no difference between the stimuli of 1°15' and 55', and between Nogo stimulation angle 24' and 15'. There was significant difference between Nogo stimulation angle 1°15' and 24', and between Nogo stimulation angle 1°15' and 15' (P<0.05). There was significant difference between Nogo stimulation angle 55' and 24', and between Nogo stimulation angle 55' and 15' (P<0.05). No significant differences were observed in the Nogo-P3 amplitude among Nogo stimulation. CONCLUSIONS: In the Go/Nogo paradigm, Nogo-P3 can reflect the cognitive response of subjects to Nogo stimulation, which can be used for objective evaluation of visual acuity.


Assuntos
Eletroencefalografia , Erros de Refração , Potenciais Evocados/fisiologia , Humanos , Estimulação Luminosa , Tempo de Reação/fisiologia , Acuidade Visual
4.
Curr Med Sci ; 42(2): 462-466, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35403953

RESUMO

OBJECTIVE: Population genetic analysis based on genetic markers harbors valuable forensic applications. In this regard, it is informative and imperative to explore Han groups as they are the largest population of China. In particular, there is a largely underrepresented amount of information from recent decades regarding the southeast costal Han Chinese. Therefore, the aim of this study is to investigate the available genetic characteristics of the Han population living in the Jinjiang, Fujian Province, Southeastern China. METHODS: We sampled 858 saliva samples and used the commercially available Microreader™ Y Prime Plus ID System to identify population data of Y-short tandem repeat (STR) loci of this region. RESULTS: A total of 822 different haplotypes were observed. The overall haplotype diversity, discriminatory power and haplotype match probability were 0.9999, 0.9999 and 0.0012, respectively. CONCLUSION: Our results showed that the Jinjiang Han population was closely genetically related to Han groups of China. Overall, we identified a set of 37 Y-STRs that are highly polymorphic, and that can provide meaningful information in forensic practice and human genetic research.


Assuntos
Cromossomos Humanos Y , Repetições de Microssatélites , DNA , Testes Genéticos , Haplótipos/genética , Humanos , Repetições de Microssatélites/genética
5.
Curr Med Sci ; 38(2): 342-348, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30074195

RESUMO

In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and two eyes. Thirty subjects were chosen, who had one eye with an acuity of 5.0, 4.85, 4.6, 4.0, or scieropia and obstructed vision and the other eye with an acuity of 5.0, respectively. P-VEPs were detected under the large grating stimuli at 3×4 spatial frequency, moderate grating stimuli (12×16 spatial frequency) and small grating stimuli (48×64 spatial frequency). Under large grating stimuli, there was no significant difference in P100 peak latency between the groups, nor was there a significant difference between the amplitude of two eyes and the amplitude of one normal-vision eye. Under moderate and small grating stimuli, there was a significant difference in P100 peak latency between the group with both eyes having an acuity of 5.0 and the group with visual acuity below 4.0 in one eye. There was a significant difference in P100 amplitude between the group with visual acuity of 5.0 in both eyes and the group with one normal-vision eye. There was no significant difference in the amplitude of two eyes and the amplitude of one normal-vision eye between any other two groups. In forensic identification, characteristics and variability of P-VEPs in one and two eyes can be used to identify malingering or decline in visual acuity.


Assuntos
Potenciais Evocados Visuais/fisiologia , Olho/metabolismo , Ciências Forenses/métodos , Reconhecimento Visual de Modelos/fisiologia , Acuidade Visual/fisiologia , Adulto , Feminino , Humanos , Masculino , Tempo de Reação , Visão Ocular/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA