Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Dalton Trans ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38859681

RESUMO

A photorechargeable supercapacitor was constructed using vanadium pentoxide (V2O5), reduced graphene oxide hydrogel (rGH), and zinc trifluoromethanesulfonate (Zn(CF3SO3)2) as the photoanode, cathode, and electrolyte, respectively. The phase composition, microstructure, chemical structure, light absorption, and specific surface area of the synthesized products and the electrochemical performance of the rGH/V2O5 supercapacitor were investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, UV-Vis spectroscopy, the Brunauer-Emmett-Teller (BET) method, and an electrochemical workstation, respectively. The results show that the device has a specific capacity of 164 F g-1 at 0.5 A g-1 under illumination with 95 mW cm-2 light intensity, which is 20.5% higher than that under normal electrical charging. The supercapacitor has a 75% capacity retention rate and 100% coulombic efficiency, respectively, after 10 000 testing cycles under photoelectric synergistic charging and discharging. The as-constructed rGH/V2O5 photorechargeable supercapacitor exhibits promising application potential in electric vehicles and wearable electronics.

2.
Molecules ; 29(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38474488

RESUMO

Supercapacitors (SCs) are a novel type of energy storage device that exhibit features such as a short charging time, a long service life, excellent temperature characteristics, energy saving, and environmental protection. The capacitance of SCs depends on the electrode materials. Currently, carbon-based materials, transition metal oxides/hydroxides, and conductive polymers are widely used as electrode materials. However, the low specific capacitance of carbon-based materials, high cost of transition metal oxides/hydroxides, and poor cycling performance of conductive polymers as electrodes limit their applications. Copper-sulfur compounds used as electrode materials exhibit excellent electrical conductivity, a wide voltage range, high specific capacitance, diverse structures, and abundant copper reserves, and have been widely studied in catalysis, sensors, supercapacitors, solar cells, and other fields. This review summarizes the application of copper-sulfur compounds in SCs, details the research directions and development strategies of copper-sulfur compounds in SCs, and analyses and summarizes the research hotspots and outlook, so as to provide a reference and guidance for the use of copper-sulfur compounds.

3.
J Mater Chem B ; 12(3): 701-709, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38131524

RESUMO

A fluorescence-electrochemiluminescence (FL-ECL) dual-mode sensor for apoE gene detection has been developed, leveraging the unique properties of ruthenium metal organic framework nanosheets (RuMOFNSs). The system utilizes the quenching effect of the Ru(bpy)32+ ECL signal by ferrocene, leading to the synthesis of a multi-electron electrical signal marker, bisferrocene. By immobilizing the P-DNA on RuMOFNSs, bisferrocene quenches both FL and ECL signals. The addition of T-DNA and the consequent formation of double-stranded DNA enable the ExoIII enzyme to excise the bisferrocene fragment, restoring the signals. The sensor demonstrates wide detection linear ranges (1 fM to 1 nM for FL and 0.01 fM to 10 pM for ECL) and remarkable sensitivity (0.048 fM for FL and 0.016 fM for ECL). The dual-mode design offers enhanced reliability through a self-correction feature, reducing false positives. Compared to single-mode sensors, the dual-mode sensor shows significant advantages. Real-world testing confirms the sensor's capacity for robust detection in actual samples, underscoring its promising application in early disease diagnosis. This innovative approach opens up avenues for multi-signal response sensors, offering significant potential for diagnostic technologies.


Assuntos
Estruturas Metalorgânicas , Rutênio , Técnicas Eletroquímicas , Medições Luminescentes , Reprodutibilidade dos Testes , DNA , Apolipoproteínas E
4.
Dalton Trans ; 52(45): 16558-16577, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37831439

RESUMO

Perovskite solar cells (PSCs) were first proposed in 2009. They have the advantages of low cost, a simple manufacturing process and excellent photoelectric performance. PSC electrodes are mainly made from precious metals such as gold and silver. Still, the cost of precious metals is high and they react with the other components of the PSCs, resulting in the poor stability of the photovoltaic device. Using carbon as an electrode material can both reduce the cost and significantly improve the stability of the photovoltaic device. However, the poor interface contact between the carbon electrode and perovskite and carbon electrode resistance results in poor photovoltaic device photoelectric performance. Finding a way to successfully utilize carbon as an alternative electrode material is a key step toward moving PSCs from the laboratory to industrialization. This paper reviews the application of carbon black, graphite, graphene, carbon nanotubes (CNTs) and composite carbon electrode in PSCs, focusing on progress in the research of doping, structure, interface modification and the production process.

5.
Biosens Bioelectron ; 235: 115385, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37229843

RESUMO

Herein, an fluorescence (FL)-electrochemiluminescence (ECL) dual-mode biosensor is constructed based on the dual-signal "turn-on" strategy of functionalized metal-organic frameworks nanosheets (RuMOFNSs)-tetraferrocene for K-ras gene detection, and the mechanism of bursting through front-line orbital theory is explained for the first time. Amino-functionalized tetraferrocene-labeled probe DNA molecules are linked to RuMOFNSs by covalent amide bonds, acting as FL and ECL intensity switches. The target DNA, complementary to the probe DNA, triggers cyclic amplification of the target by nucleic acid exonuclease III (Exo III), repelling tetraferrocene reporter groups away from RuMOFNSs and inhibiting the electron transfer process and photoinduced electron transfer (PET) effect. These phenomena induce a double turn-on of FL and ECL signals with a high signal-to-noise ratio. The developed FL-ECL dual-mode sensing platform provides sensitive detection of the K-ras gene with detection limits of 0.01 fM (the detection range is 1 fM to 1 nM) and 0.003 fM (the detection range is 0.01 fM to 10 pM), respectively. In addition, the proposed dual-mode sensor can be easily extended to detect other disease-related biomarkers by changing the specific target and probe base sequences, depicting potential applications in bioanalysis and early disease diagnosis.


Assuntos
Técnicas Biossensoriais , Genes ras , Medições Luminescentes , DNA/genética , Fotometria , Sondas de DNA/química
6.
ACS Appl Mater Interfaces ; 15(10): 13086-13096, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36853078

RESUMO

The agglomeration of graphene sheets and undesired pore size distribution usually lead to unsatisfactory electrochemical properties of reduced graphene oxide (RGO) film electrodes. Herein, crumpled exfoliated graphene (EG) sheets are adopted as the microstructure-regulating agent to tune the morphology and micro-/mesopore amounts with the aim of increasing active surface sites and ion transportation paths in electrodes. With the optimum ratio between EG and GO, the resulting 75%-EG/RGO shows significantly improved specific gravimetric capacitance (Cs) and rate capability when compared with pure RGO electrodes in a symmetrical supercapacitor system. Moreover, when coupling the 75%-EG/RGO cathode with a Zn anode to form a Zn ion hybrid supercapacitor (ZHS), the 75%-EG/RGO exhibits a much higher Cs of 327.39 F g-1 at 0.1 A g-1 and can maintain 91.7% capacitance after 8000 cycles. Systematic ex situ X-ray diffraction (XRD) and X-ray photoelectron spectra (XPS) measurements reveal that the charge storage mechanism is based on both reversible physical adsorption and dual ion uptake. Furthermore, the quasi-solid-state flexible ZHS also presents high capacitive performance and can maintain ∼100% capacitance under various bending states, demonstrating potential application in wearable electronics. This strategy opens up a new path for constructing high-performance graphene film electrodes.

7.
Biosens Bioelectron ; 139: 111296, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31128480

RESUMO

Remarkable research efforts have been devoted to replicate the tactile sensitivity of human skin. Unfortunately, so far flexible pressure sensors reported barely fit the tactile requirements for fingertips, which could endure a pressure over 100 kPa and also can sense a gentle touch. It is vital to develop flexible pressure sensors which can ensure high sensitivity and wide operation range simultaneously, to satisfy the demands of mimicking the pressure sensing function of fingertips. In this work, a mini-size, light-weight but high-performance graphene film based pressure sensor is presented. Owing to the advanced structure with fluctuations on surface and fluffy-layered structure in cross-section of the graphene film, this pressure sensor shows an extraordinary performance of high sensitivity of 10.39 kPa-1 (0-2 kPa), ultra-wide operation range up to 200 kPa, impressively stable repeatability, high working frequency, rapid response and recovery time. Moreover, the demonstrated results of the detection of traditional Chinese medicine wrist-pulse waveform and the bionic fingertip tactile sensors, suggest the great application potential of the obtain device in biomedical field and bionic skins field.


Assuntos
Biônica/métodos , Técnicas Biossensoriais , Pele/química , Dispositivos Eletrônicos Vestíveis , Grafite/química , Humanos , Medicina Tradicional Chinesa , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA