Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(7): 12747-12762, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38571089

RESUMO

The interference-less coded aperture correlation holography is a non-scanning, motionless, and incoherent technique for imaging three-dimensional objects without two-wave interference. Nevertheless, a challenge lies in that the coded phase mask encodes the system noise, while traditional reconstruction algorithms often introduce unwanted surplus background components during reconstruction. A deep learning-based method is proposed to mitigate system noise and background components simultaneously. Specifically, this method involves two sub-networks: a coded phase mask design sub-network and an image reconstruction sub-network. The former leverages the object's frequency distribution to generate an adaptive coded phase mask that encodes the object wave-front precisely without being affected by the superfluous system noise. The latter establishes a mapping between the autocorrelations of the hologram and the object, effectively suppresses the background components by embedding a prior physical knowledge and improves the neural network's adaptability and interpretability. Experimental results demonstrate the effectiveness of the proposed method in suppressing system noise and background components, thereby significantly improving the signal-to-noise ratio of the reconstructed images.

2.
Opt Lett ; 49(3): 702-705, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300094

RESUMO

Phase measuring deflectometry is a powerful measurement tool of optical surfaces, but the measuring accuracy relies on the quality of system calibration. Calibration errors arise from the oversimplified imaging models, error accumulation and amplification, and the bias in numerical optimization. A holistic calibration method is proposed to shorten the error propagation chain. The descriptive prowess of the imaging system is enhanced by calculating each incident ray independently and compensating the systematic errors resulting from the form error of the calibration mirror. Finally, a holonomic framework prior is defined to guarantee the calibration reliability by utilizing the physical constraints of the measurement system. Experimental results demonstrate that the proposed method improves measurement accuracy by at least 38% compared to traditional approaches.

3.
Opt Lett ; 48(22): 6012-6014, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37966776

RESUMO

We propose a dielectric corrugated structure surrounded by two monolayer graphene and find that the structure supports bound states in the continuum (BIC). By introducing a phase difference between the upper and lower surface of dielectric grating, the symmetry of the structure is broken, and the BIC turns into quasi-BIC. In addition, we find that the Fermi energy of graphene strongly affect the spectral line. By controlling phase difference and Fermi energy of graphene, the ultrahigh Q-factor can be achieved. Finally, introducing a sensing medium at the incident side, the high performance sensor is realized.

4.
ACS Appl Mater Interfaces ; 15(26): 31812-31823, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37345360

RESUMO

Energy recovery and reuse, industrial waste heat, and thermal energy recovery and conversion in emerging electronic devices are topics of widespread interest. Flexible composite thermoelectric (TE) films have become the key to TE conversion, and many studies and synthesis methods related to them have made great progress. However, little research has been performed on the corresponding composites of typical TE materials with low-dimensional nanotubular materials, particularly modulation of the overall TE properties using doped low-dimensional nanotubular materials. In this work, high-quality bismuth telluride (Bi2Te3) nanowires and boron nitride nanotubes (BNNTs) were prepared using electrolytic deposition and high-temperature catalytic deposition, respectively. Bi2Te3-BNNTs composite films were prepared using a solvent hot pressing method. The Bi2Te3-BNNTs composite film conductivity reached 179.6 S/cm at room temperature (300 K), the corresponding Seebeck coefficient was 171.4 µV/K, and the power factor (PF) was 52.8 nW/mK2. Carbon doping of BNNTs resulted in carbon-boron nitride nanotubes (BCNNTs), and Bi2Te3-BNNTs composite films were prepared. The Bi2Te3-BCNNTs composite films obtained a conductivity of 4629.6 S/cm, at room temperature (300 K), a corresponding Seebeck coefficient of 181.2 µV/K, and a PF of 1520.0 nW/mK2. This study has important reference value for the application of TE conversion. Moreover, the electrical conductivity decreased by no more than 10% after 400 cycles of bending tests, and the electrical conductivity showed signs of recovery after repressing thermally, which undoubtedly proves that Bi2Te3-BCNNTs composite films have good flexibility and thermal stability, and this has contributed to the application and promotion of flexible thermoelectric materials.

5.
Opt Express ; 31(4): 6552-6565, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36823908

RESUMO

We propose a polarized, angle-resolved spectral (PARS) reflectometry for simultaneous thickness and refractive-index measurement of ultra-thin films in real time. This technology acquires a two-dimensional, angle-resolved spectrum through a dual-angle analyzer in a single shot by radially filtering the back-focal-plane image of a high-NA objective for dispersion analysis. Thus, film parameters, including thickness and refractive indices, are precisely fitted from the hyper-spectrum in angular and wavelength domains. Through a high-accuracy spectral calibration, a primary PARS system was built. Its accuracy was carefully verified by testing a set of SiO2 thin films of thicknesses within two µm grown on monocrystalline-Si substrates against a commercial spectroscopic ellipsometer. Results show that the single-shot PARS reflectometry results in a root-mean-square absolute accuracy error of ∼1 nm in film thickness measurement without knowing its refractive indices.

6.
Sensors (Basel) ; 22(23)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36501768

RESUMO

This paper studies the cooperative control of multiple unmanned aerial vehicles (UAVs) with sensors and autonomous flight capabilities. In this paper, an architecture is proposed that takes a small quadrotor as a mission UAV and a large six-rotor as a platform UAV to provide an aerial take-off and landing platform and transport carrier for the mission UAV. The design of a tracking controller for an autonomous docking and landing trajectory system is the focus of this research. To examine the system's overall design, a dual-machine trajectory-tracking control simulation platform is created via MATLAB/Simulink. Then, an autonomous docking and landing trajectory-tracking controller based on radial basis function proportional-integral-derivative control is designed, which fulfills the trajectory-tracking control requirements of the autonomous docking and landing process by efficiently suppressing the external airflow disturbance according to the simulation results. A YOLOv3-based vision pilot system is designed to calibrate the rate of the aerial docking and landing position to eight frames per second. The feasibility of the multi-rotor aerial autonomous docking and landing technology is verified using prototype flight tests during the day and at night. It lays a technical foundation for UAV transportation, autonomous take-off, landing in the air, and collaborative networking. In addition, compared with the existing technologies, our research completes the closed loop of the technical process through modeling, algorithm design and testing, virtual simulation verification, prototype manufacturing, and flight test, which have better realizability.

7.
Opt Express ; 30(23): 42454-42469, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36366699

RESUMO

In the field of three-dimensional (3-D) metrology based on fringe projection profilometry (FPP), accurate camera calibration is an essential task and a primary requirement. In order to improve the accuracy of camera calibration, the calibration board or calibration target needs to be manufactured with high accuracy, and the marker points in calibration image require to be positioned with high accuracy. This paper presents an improved camera calibration method by simultaneously optimizing the camera parameters and target geometry. Specifically, a set of regularly distributed target markers with rich coded concentric ring pattern is first displayed on a liquid crystal display (LCD) screen. Then, the sub-pixel edges of all coded bands radial straight lines are automatically located at several positions of the LCD screen. Finally, the sub-pixel edge point set is mapped into parameter space to form a line set, and the intersection of the lines is defined as the center pixel coordinates of each target point to complete the camera calibration. The simulation and experimental results verify that the proposed camera calibration method is feasible and easy to operate, which can essentially eliminate the perspective transformation error to improve the accuracy of camera parameters and target geometry.

8.
Opt Express ; 30(15): 28207-28219, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236973

RESUMO

In the field of optical three-dimension (3-D) measurement, reconstruction usually is completed by the integration of a two-dimensional (2-D) gradient data set. Position and posture of camera and shape of the surface under test determine the location of gradient data which usually is on quadrilateral grids. This paper proposes a B-spline surface-based 3D reconstruction method for deflectometry, which reconstructs the surface under test with its 2-D gradient data set. The 2-D gradient data set consists of gradient data and the 2-D location of the gradient data in the camera coordinate system. The 2-D gradient data set is first transferred to the cameras' virtual image plane, so it locates on rectangular grids. Then, based on the properties of the B-spline basis function and characteristics of the camera, linear equations are derived to solve control points along the virtual image plane. The solved control points reconstruct the surface under test in the camera coordinate system. The property of the B-spline basis function determines the relationship between the depth of the surface and its derivative. The characteristic of the camera determines the relationship between the depth of the surface and the 2-D location of the gradient data. Meanwhile, the accuracy of the 2-D location can also be improved by the linear equations. Finally, simulated and actual experiments show that the proposed method is accurate and efficient at reconstructing surfaces in deflectometry.

9.
Opt Express ; 30(10): 17554-17566, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-36221575

RESUMO

Phase measuring deflectometry (PMD) is an important technique for the form measurement of specular surfaces. However, the existing stereo-PMD techniques have noticeable weaknesses for structured specular surfaces measurement due to the optical axis of the imaging system must have a notable intersection angle with the optical axis of the display system according to the law of reflection. This leads to the imaging sensor and the fringe display screen must be located on the opposite sides of the normal of the surface under test (SUT), which results in large system volume and measurement shadows when measuring discontinuous specular surfaces. In this paper, we propose a novel near optical coaxial PMD (NCPMD) by utilizing a plate beamsplitter. With the assistance of plate beamsplitter, the optical axis of display screen can be configured much closer to the optical axis of the imaging system which makes the system more compact and has significantly reduced volume compared with the conventional PMD configuration. Moreover, imaging sensors in the proposed configuration can perpendicularly capture the SUT, which can drastically decrease measurement shadows caused by discontinuous structures on the SUT and increases measurement efficiency. A comparison between the proposed NCPMD and the conventional PDM is studied by measuring a specular step to show the advantage of the proposed configuration in reducing measurement error caused by structure shadows. A portable NCPMD prototype with stereo imaging sensors is developed and verified through experiments. Experimental results show the portable prototype has comparable measurement accuracy with the existing PMD techniques while has obviously advanced performances for portable and embedded form measurement, such as small system volume, and light weight.

10.
Opt Express ; 30(18): 31863-31871, 2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36242260

RESUMO

The orbital angular momentum (OAM) holography has been identified as a vital approach for achieving ultrahigh-capacity in 3D displays, digital holographic microscopy, data storage and so on. However, depth has not been widely applied as a multiplexing dimension in the OAM holography mainly because of the serious coherence crosstalk between different image layers. The multi-layered depth multiplexing OAM holography is proposed and investigated. To suppress the coherence crosstalk between different image channels, random phases are used for encoding different image layers separately. An image can be reconstructed with high quality at a specific depth from an appropriate OAM mode. It is demonstrated that the depth multiplexing of up to 5 layers can be achieved. This work can increase the information capacity and enhance the application of the OAM holography.

11.
Micromachines (Basel) ; 13(9)2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36143995

RESUMO

The fabrication process of vacuum ultraviolet (VUV) detectors based on traditional semiconductor materials is complex and costly. The new generation of wide-bandgap semiconductor materials greatly reduce the fabrication cost of the entire VUV detector. We use the chemical vapor deposition (CVD) method to grow boron nitride nanoribbons (BNNRs) for VUV detectors. Morphological and compositional characterization of the BNNRs was tested. VUV detector based on BNNRs exhibits strong response to VUV light with wavelengths as short as 185 nm. The photo-dark current ratio (PDCR) of this detector is 272.43, the responsivity is 0.47 nA/W, and the rise time and fall time are 0.3 s and 0.6 s. The response speed is faster than the same type of BN-based VUV detectors. This paper offers more opportunities for high-performance and low-cost VUV detectors made of wide-bandgap semiconductor materials in the future.

12.
Opt Lett ; 47(8): 1933-1936, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35427304

RESUMO

We present a centroid algorithm with asymmetry-robust error compensation for the peak position localization of asymmetrical axial response signals in confocal microscopy. Compared with the state-of-the-art algorithms, which are usually developed for symmetrical signals, our asymmetry robust centroid algorithm is found to have much smaller localization bias and higher precision for an asymmetrical confocal signal in numerical simulations and experiments.


Assuntos
Algoritmos , Microscopia Confocal
13.
Opt Express ; 30(7): 11110-11119, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35473061

RESUMO

The orbital angular momentum (OAM) holography has been identified as a vital approach for achieving ultrahigh-capacity multiplexation without a theoretical helical phase index limit. However, the encoding and decoding of an OAM hologram require a complete helical phase mode, which does not take full utilization of the angular space. In this paper, the partial OAM holography is proposed by dividing an OAM mode into several partial orbital angular momentums and encode each partial mode with a different target image. An image can only be reconstructed using an appropriate partial OAM mode within a specific illuminating angular range, henceforth holographic multiplexation of images can be realized. This method can significantly increase the holographic information capacity and find widespread applications.

14.
Opt Lett ; 46(7): 1616-1619, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33793501

RESUMO

We introduce an iteration-free approach, based on a centroid algorithm with a locally adaptive threshold, for nanometer-level peak position localization of the axial response signal in confocal microscopy. This approach has localization accuracies that are near theoretical limits, especially when there is a small number of sampling points within the discrete signal. The algorithm is also orders of magnitude faster compared to fitting schemes based on maximum likelihood estimation. Simulations and experiments demonstrate the localization performance of the approach.

15.
Opt Express ; 29(5): 7179-7196, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33726224

RESUMO

In chromatic confocal microscopy, the signal characteristics influence the accuracy of the signal processing, which in turn determines measurement performance. Thus, a full understanding of the spectral characteristics is critical to enhance the measurement performance. Existing spectral models only describe the signal intensity-wavelength characteristics, without taking the displacement-wavelength relation into consideration. These models require prior knowledge of the optical design, which reduces the effectiveness in the optical design process. In this paper, we develop a two-dimensional spectral signal model to describe the signal intensity-wavelength-displacement characteristics in chromatic confocal microscopy without prior knowledge of the optical design layout. With this model, the influence of the dimensional characteristics of the confocal setup and the displacement-wavelength characteristics and monochromatic aberrations of the hyperchromatic objective are investigated. Experimental results are presented to illustrate the effectiveness of our signal model. Using our model, further evaluation of the spectral signal can be used to enhance the measurement performance of chromatic confocal microscopy.

16.
J Opt Soc Am A Opt Image Sci Vis ; 37(9): OMI1-OMI2, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32902440

RESUMO

Optical measurement and characterization are two of the pillars of metrology. The ability to measure precisely with high dynamic range and accuracy betters our understanding of nature and the universe. In this feature issue, we present a collection of articles that delves into the fundamental techniques used to advance the field.

17.
Appl Opt ; 59(10): 2983-2991, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400575

RESUMO

For white-light spectral interferometry, the phase information is usually retrieved via the Fourier transform method and the temporal phase-shifting method. In comparison, the synchronous phase-shifting method can be used to synchronously acquire interferometric signals with good accuracy and reduced noise. Therefore, it has potential for online measurement and is suitable for application in precision industries and for ultrahigh-speed measurement. In this work, a white-light spectral interferometer for synchronous phase shifting based on polarization interference was built, and the two-step phase-shifting algorithm was used to retrieve phase information. A variety of spectral interferometric signals were simulated based on the mathematical model of the two-step phase-shifting algorithm to illustrate the effects of differences in intensity and envelope shape, random noise, and phase-shift error on measurement of the absolute distance. Measurements of the absolute distance were conducted, and they indicated that the system had high accuracy.

18.
Appl Opt ; 59(13): 3819-3824, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400648

RESUMO

Off-axis deflectometry is widely applied in the measurement of specular surfaces. However, the measuring accuracy depends on the reliability of geometrical calibration. Existing methods are inconvenient to be utilized due to their disadvantages of low efficiency and operational complexity. A simple geometrical calibration method is proposed by applying a flat mirror with markers, and only one image needs to be captured. A compensation process is introduced to correct the form error of the mirror. Experimental results show that the re-projection errors decrease from 0.319 pixels down to 0.12 pixels; thus the measuring efficiency and accuracy of optical surfaces can be greatly improved.

19.
Opt Express ; 27(23): 33999-34010, 2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31878457

RESUMO

Several optical instruments have been presented over recent years that use a tilted diffraction grating in the reference arm, describing its effect as introducing a continuous optical delay in the direction of the grating dispersion. Having examined these types of system carefully, we believe this description does not fully capture the manner by which the signal is formed in these instruments, and present here a simple model that clearly demonstrates the essential elements behind the way such systems operate. This analysis not only illustrates the reason for signals of the form seen being generated, but also shows how great care needs to be taken with systems such as these in the interpretation of the results.

20.
Opt Express ; 27(16): 22737-22752, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31510560

RESUMO

Characterization of the displacement response is critical for accurate chromatic confocal measurement. Current characterization methods usually provide a linear or polynomial relationship between the extracted peak wavelengths of the spectral signal and displacement. However, these methods are susceptible to errors in the peak extraction algorithms and errors in the selected model. In this paper, we propose a hybrid radial basis function network method to characterise the displacement response. With this method, the peak wavelength of the spectral signal is firstly extracted with a state-of-art peak extraction algorithm, following which, a higher-accuracy chromatic dispersion model is applied to determine the displacement-wavelength relationship. Lastly, a radial basis function network is optimized to provide a mapping between the spectral signals and the residual fitting errors of the chromatic dispersion model. Using experimental tests, we show that the hybrid radial basis function network method significantly improves the measurement accuracy, when compared to the existing characterizing methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA