Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 24(14): 1629-1637, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33779444

RESUMO

Trans-catheter aortic valve implantation (TAVI) is an increasingly adopted technique which provides a minimal invasive solution for patients who suffer from severe aortic stenosis. Some complications of the procedure could be annular rupture or paravalvular leakage, both related with adverse outcome. In TAVI with balloon expandable devices, a mismatch between those two factors leads to a conflict situation, where improving one worsens the other. The presented research proposes a methodology that uses numerical simulation to obtain certain TAVI outcomes related with aortic regurgitation due to paravalvular leakage, such as perivalvular area, aortic eccentricity or annular pressure. The application of the methodology for two patients shows the possibility of predicting those quantities. The highest stress values are distributed along the contact area. Results also show that a great deformation on the aortic annulus does not necessarily imply a higher stress; pressure can either be converted into root reshape or into root stretching. Validation of the results was done using scientific publications, clinical guidelines and clinical reports. Numerical simulation provides a suitable tool that could possibly contribute to optimize the planification procedure adjusting the mismatch between size and pressure.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
2.
Comput Methods Biomech Biomed Engin ; 23(8): 303-311, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31996041

RESUMO

Aortic stenosis (AS) disease is a narrowing of the aortic valve (AV) opening which reduces blood flow from the heart causing several health complications. Although a lot of work has been done in AV simulations, most of the efforts have been conducted regarding healthy valves. In this article, a new three-dimensional patient-specific biomechanical model of the valve, based on a parametric formulation of the stenosis that permits the simulation of different degrees of pathology, is presented. The formulation is based on a double approach: the first one is done from the geometric point of view, reducing the effective ejection area of the AV by joining leaflets using a zipper effect to sew them; the second one, in terms of functionality, is based on the modification of AV tissue properties due to the effect of calcifications. Both healthy and stenotic valves were created using patient-specific data and results of the numerical simulation of the valve function are provided. Analysis of the results shows a variation in the first principal stress, geometric orifice area, and blood velocity which were validated against clinical data. Thus, the possibility to create a pipeline which allows the integration of patient-specific data from echocardiographic images and iFR studies to perform finite elements analysis is proved.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Simulação por Computador , Eletrocardiografia , Análise de Elementos Finitos , Ventrículos do Coração/fisiopatologia , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA