Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Front Cardiovasc Med ; 10: 1129529, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252122

RESUMO

Rheumatic heart disease (RHD) is a widespread illness in developing countries. RHD causes 99% of mitral stenoses in adults and 25% of aortic regurgitation. However, it only causes 10% of stenoses of the tricuspid valve, and is almost always associated with left-side valvular lesions. Isolated right-side valves are rarely affected, but may result in severe rheumatic pulmonary regurgitation. Herein, we present a case of rheumatic right-sided valve disease with severe pulmonary valve contracture and regurgitation in a symptomatic patient, successfully managed by surgical valvular reconstruction with a tailored bileaflet bovine pericardial patch. The options for surgical approach are also discussed. To our knowledge, the presented rheumatic right-sided valve disease with severe pulmonary regurgitation is the first to be reported in the literature.

2.
Eur J Cardiothorac Surg ; 59(6): 1304-1311, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33532832

RESUMO

OBJECTIVES: The feasibility of mini-invasive closure of perimembranous ventricular septal defects has been proven, but can cause surgical incision or sternum injury. A relevant but, to date, unanswered question is whether there exists a treatment without surgical trauma, radiation exposure and arterial complications. METHODS: From May 2017 to January 2020, a total of 449 patients with perimembranous ventricular septal defect [mean age 5.0 ± 6.1 years (range 0.8-52.0 years)] were involved in this study and underwent 2 different echocardiography-guided operative procedures [percutaneous device closure (group A) or percardiac device closure (group B)] based on the patients' or their parents' choice. The clinical data were collected and a retrospective analysis was performed. RESULTS: Fifty-five (96.5%) cases were successfully occluded in group A, and 2 (3.5%) patients were converted to percardiac device closure; 379 (96.7%) patients in group B underwent percardiac device closure, and 13 patients (3.3%) were turned to open-heart surgery after occlusion procedure failure. There were statistically significant differences (P < 0.05) between the 2 groups in operation time, postoperative hospitalization time and blood transfusion requirement. No acute complications or severe adverse events (death, valve injury, complete atrioventricular block and embolism) occurred either in the early period or during the follow-up. CONCLUSIONS: Percutaneous device closure can achieve the same validity and safety as percardiac device closure for treating perimembranous ventricular septal defects with a more rapid recovery and less trauma.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Ecocardiografia , Ecocardiografia Transesofagiana , Seguimentos , Humanos , Lactente , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
3.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 46(12): 1380-1385, 2021 Dec 28.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-35232908

RESUMO

OBJECTIVES: Residual ventricular septal defect (VSD) after congenital heart disease (CHD) is one of the major postoperative complications in cardiac surgery. At present, the commonly used clinical treatment methods for this complication are reoperation to redo surgical repair with cardiopulmonary bypass (CPB) and percutaneous transcatheter device closure, but these 2 methods have their own advantages and disadvantages. Transthoracic punctural closure of residual VSD is a feasible, safe, and novel technique for patients with residual VSD, which avoids not only the risk of difficulties in reoperation under another CPB due to thoracic adhesion, but also the risk of radiation exposure. Moreover, the operation is easier to handle due to short and direct operation path. This study aims to explore the role and value of echocardiography in transthoracic punctural closure of postoperative residual VSD of CHD. METHODS: A total of 25 patients, who were admitted in the Department of Cardiovascular Surgery, Second Xiangya Hospital, Central South University and accepted transthoracic punctural closure of postoperative residual VSD, were collected. The morphology of the residual VSD and the distance from tricuspid valve and aortic valve were assessed by trans-esophageal echocardiography (TEE) preoperatively, and the location of the punctural point and the direction of puncture were determined. The establishment of delivery track and releasing of occluder device were accurately guided by TEE intraoperatively. The position and morphology of the occluder device, residual shunt, aortic regurgitaion, and outflow obstruction were required close attention in immediately postoperative evaluation. If any dislocation or residual shunt was found, adjustments were needed immediately. Follow-ups were performed at 3-5 days, 1 month, 3 months, 6 months, and 1 year after operation. Occluder location, residual shunt, valvular function, and other complications were observed by transthoracic echocardiography (TTE) to assess the effect of the closure by occluder. Ventricular size and cardiac function were determined to evaluate the state of ventricular remodeling. In addition, cardiac rhythm was monitored by ECG periodically. RESULTS: Of the 25 patients underwent transthoracic punctural closure of postoperative residual VSD, except 1 double outlet right ventricle (DORV) and 1 tetralogy of fallot (TOF) postoperative patients failured and immediately received a thoracotomy surgery with CPB due to excessive size of residual defect and the irregular morphology, the rest 23 patients were successfully closed by the occluders (92.0%). Among the 23 occluders (diameters range from 5 mm to 10 mm), membrane symmetrical VSD occluders were applied to 17 cases, small-waist-large-edge VSD occluder was applied to 1 case, and eccentric VSD occluders were applied to 5 cases. TEE, applied immediately after occlusion, showed the satisfactory position and the shaping of the occluders. There were no residual shunts, no cardiac tamponade, no thrombosis and outflow obstruction. Two patients had small amounts of pericardial effusion. No newly emerging valve reflux was observed. After 3-48 months of observation, there was no device displacement, newly emerging valve reflux, and residual shunt. One case had incomplete right bundle branch block. CONCLUSIONS: Guided by TEE, transthoracic punctural closure of postoperative residual ventricular septal defect of CHD is safe and effective. This procedure has broadened the indications for the minimally invasive treatment of CHD and improved the technical system of the minimally invasive treatment of CHD. TEE which can provide accurate diagnosis and guide the whole process plays a decisive role in this operation technique.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Resultado do Tratamento
4.
Mol Biol Rep ; 47(10): 7557-7566, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32929654

RESUMO

The main pathogenesis of type 1 diabetes mellitus (T1DM) is autoimmune-mediated apoptosis of pancreatic islet ß cells. We sought to characterize the function of microRNA-203a (miR-203a) on pancreatic islet ß cell proliferation and apoptosis. In situ hybridization was used to detect the expression of miR-203a in islet ß cells in normal and hyperglycaemic non-obese diabetic (NOD) mice. Cell proliferation was measured by cell counting kit eight and cell apoptosis was detected using flow cytometry. Insulin receptor substrate 2 (IRS2/Irs2) was determined to be a direct target of miR-203a by Luciferase reporter assay. We detected the effects of miR-203a overexpression or inhibition on proliferation and apoptosis of IRS2-overexpressing or IRS2-knockdown MIN6 cells respectively, and preliminarily explored the downstream targets of the IRS2 pathway. NOD mice model was used to detect miR-203a inhibitor treatment for diabetes. Our experiment showed miR-203a was upregulated in pancreatic ß cells of hyperglycaemic NOD mice. Elevated miR-203a expression inhibited the proliferation and promoted the apoptosis of MIN6 cells. IRS2/Irs2 is a novel target gene directly regulated by miR-203a and miR-203a overexpression downregulated the expression of IRS2. Irs2 silencing reduced cell proliferation and increased apoptosis. Irs2 overexpression could abolish the pro-apoptotic and anti-proliferative effects of miR-203a on MIN6 cells. Hyperglycemia in newly hyperglycemic NOD mice was under control after treatment with miR-203a inhibitor. Our study suggests that miR-203a regulates pancreatic ß cell proliferation and apoptosis by targeting IRS2, treatment with miR-203a inhibitors and IRS2 might provide a new therapeutic strategy for T1DM.


Assuntos
Apoptose , Proliferação de Células , Hiperglicemia/metabolismo , Proteínas Substratos do Receptor de Insulina/biossíntese , Células Secretoras de Insulina/metabolismo , MicroRNAs/metabolismo , Animais , Linhagem Celular , Feminino , Hiperglicemia/patologia , Células Secretoras de Insulina/patologia , Camundongos , Camundongos Endogâmicos NOD
5.
BMC Pediatr ; 19(1): 302, 2019 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-31472688

RESUMO

BACKGROUND: Traditional percutaneous device closure of perimembranous ventricular septal defects (PmVSDs) is a minimally invasive technique, but can result in high radiation exposure and can result in potential arterial complications. Here, we aimed to assess the safety and feasibility of device closure of PmVSDs via the femoral vein approach under transesophageal echocardiography (TEE) guidance in children. METHODS: From January 2014 to December 2017, a total of 46 PmVSD patients (mean age, 6.5 ± 2.3 years [range, 4.2-12.0 years]; mean body weight 22.1 ± 6.6 kg [range, 16.0-38.5 kg]; VSD diameter, 4.1 ± 0.6 mm [range, 3.2-5.0 mm]) underwent attempted transcatheter closure via the femoral vein approach under the guidance of TEE without fluoroscopy. RESULTS: The transcatheter occlusion procedure under TEE guidance was successful in 44 (95.7%) patients. Surgery was necessary in 2 (4.3%) patients. The procedure duration was 28.2 ± 8.7 min (range, 12.0-42.0 min). One patient had immediate post-operative trivial residual shunt and three patients had immediate incomplete right bundle branch block (IRBBB) after operation; the new IRBBB in 1 case was noted in the first postoperative month. No residual shunt was noted at 3 months after the procedure, and no intervention related complications were detected at 1-24 months follow-up. CONCLUSIONS: Percutaneous device closure of PmVSDs under TEE guidance solely by femoral vein approach is effective and safe, avoids radiation exposure, potential arterial complications and a surgical incision.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interventricular/terapia , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Veia Femoral , Comunicação Interventricular/diagnóstico por imagem , Humanos , Masculino , Ilustração Médica , Duração da Cirurgia , Exposição à Radiação/prevenção & controle
6.
Congenit Heart Dis ; 14(3): 324-330, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30714327

RESUMO

OBJECTIVE: To evaluate safety and effectiveness of intraoperative device closure for secundum atrial septal defect (ASD) not referred to percutaneous closure. DESIGN AND PATIENTS: From April 2010 to December 2018, 231 secundum ASD children (≤14 years) directly recommended to surgical repair were enrolled in this study. These patients were divided into two groups according to the parents' choice based on surgeons' recommendation. Follow-up evaluations were adopted at 2 weeks, 3 months, 6 months, and 12 months after the procedure and yearly thereafter. In Group A, 127 patients underwent an initial attempt at device closure. In Group B, 104 patients underwent a repair procedure under cardiopulmonary bypass. RESULTS: All patients survived. Group A had lower values of operation time, mechanical ventilation time, cardiac intensive care unit duration and amount of blood transfusion. Nevertheless, postoperative hospitalization time between two groups showed no statistical difference. In group A, 109 (85.83%) patients were successfully occluded, whereas 18 (14.17%) patients were converted to open-heart surgery. No severe complications occurred in the follow-up period. CONCLUSION: Intraoperative device closure is safe, effective procedure for selected cases with secundum ASDs which were not referred to percutaneous closure because of more suitable occluder selection, no "unbutton effect" and stitching enhancement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial/cirurgia , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Criança , Pré-Escolar , Procedimentos Clínicos , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fatores de Risco , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento
7.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 43(9): 1000-1006, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30333292

RESUMO

OBJECTIVE: To evaluate the feasibility and safety of device closure of patent ductus arteriosus (PDA) using only venous access under echocardiography guidance alone.
 Methods: A total of 102 consecutive pediatric patients underwent transcatheter PDA closure without arterial access, under the guidance of only echocardiography. The patients were followed up by clinical examination, electrocardiogram, and echocardiogram at 1, 3, 6 12, and 24 months.
 Results: Transvenous PDA closure under echocardiographic guidance was successful in 99 (97.1%) patients. There were no acute procedural complications or severe adverse events. The duration ranged from 10 to 65 minutes (median, 21 minutes). Immediate complete closure of PDA was achieved in 87 patients (87.9%), and 100% of the patients were completely closed after 24 h. There were no severe adverse events in the period of 1-24 months (median, 12 months) follow up.
 Conclusion: Transvenous PDA closure without fluoroscopy avoids radiation exposure, contrast agent usage and potential arterial complications. It can be used as an alternative procedure, especially for children.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Permeabilidade do Canal Arterial , Ecocardiografia , Procedimentos Cirúrgicos Cardíacos/normas , Criança , Permeabilidade do Canal Arterial/cirurgia , Humanos , Resultado do Tratamento , Veias/cirurgia
8.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 42(7): 802-807, 2017 Jul 28.
Artigo em Chinês | MEDLINE | ID: mdl-28845004

RESUMO

OBJECTIVE: To investigate the feasibility and safety of perimembranous ventricular septal defects (PmVSD) closure solely by femoral vein approach under transesophageal echocardiography (TEE) guidance.
 Methods: From January 1, 2014 to May 31, 2016, 26 patients with PmVSD in Second Xiangya Hospital were selected, with age at 3.2-6.0 (4.3±0.7) years old and body weight at 15.0-19.5 (16.7±1.4) kg. The diameter of VSD was 3.5-4.8 (4.1±0.3) mm. All patients were treated by percutaneous PmVSD closure solely by femoral vein approach under TEE guidance. The effect of the procedure was evaluated by TEE and transthoracic echocardiography (TTE). The clinical follow-up study was conducted by TTE at 1, 3, 6 and 12 month (s) after the procedure.
 Results: Twenty cases were successfully treated with percutaneous PmVSD closure solely by femoral vein approach under TEE guidance, and the success rate was 76.9%. Six patients were converted to perventricular closure under TEE guidance because the guide wire in two cases or catheter in other cases could not pass through PmVSD. The diameter of symmetrical VSD occluder was 6.0-7.0 (6.2±0.4) mm. The procedural time was 12.0-64.0 (26.8±6.3) min. The residence time at ICU was 1.8-2.4 (26.8±6.3) h. The in-hospital time was 4.0-5.0 (4.4±0.5) d. There were 3 patients with immediate post-operative trivial residual shunt and incomplete right bundle branch block (IRBBB). All patients survived with no peripheral vascular injury or complications such as tricuspid regurgitation, pericardial tamponade and pulmonary infection. The residual shunt disappeared in 3 patients and IRBBB became normal rhythm in 3 patients at 1 month follow-up time point. No patients suffered from occluder malposition, residual shunt, pericardial effusion, arrhythmia (atrio-ventricular block), aortic valve regurgitation and tricuspid regurgitation.
 Conclusion: TEE-guided percutaneous PmVSD closureby femoral vein approach is safe and effective.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interventricular/cirurgia , Criança , Pré-Escolar , Veia Femoral , Seguimentos , Humanos , Dispositivo para Oclusão Septal , Resultado do Tratamento
9.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 41(7): 691-5, 2016 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-27592572

RESUMO

OBJECTIVE: To investigate the outcomes of hybrid procedure in treating 10 infants/children with pulmonary stenosis under transesophageal echocardiographic guidance.
 METHODS: Between September, 2009 and December, 2015, 10 infants/children underwent hybrid procedure of transthoracic balloon pulmonary valvuloplasty for pulmonary stenosis in the Second Xiangya Hospital, Central South University. The age, height and weight at the time of admission were 0.7-42 (14.8±15.8) months, 53-97 (74.8±16.3) cm, and 4-15.5 (9.3±4.1) kg, respectively. Atrial septal defect, patent foramen ovale, patent ductus arteriosus, muscular ventricular septal defect, persistent left superior vena cava and tricuspid regurgitation were found in 2, 6, 1, 2, 1 and 5 cases, respectively.
 RESULTS: After the operation, all patients were sent into ICU. The mean duration mechanical ventilation, ICU stay and hospitalization were 0.5-41(6.8±12.3) h, 2-85 (31.1±22.8) h, and 6-20 (11.4±5.1) d, respectively. Postoperative transvalvular pressure gradient reduced to 16-45 (31.1±9.8) mmHg, which was decreased significantly compared with that in preoperative (P<0.001). There was no death during hospitalization and follow-up.
 CONCLUSION: Hybrid procedure of transthoracic balloon pulmonary valvuloplasty for pulmonary stenosis under transesophageal echocardiographic guidance is a safe and effective treatment.


Assuntos
Ecocardiografia Transesofagiana , Estenose da Valva Pulmonar , Criança , Comunicação Interatrial , Comunicação Interventricular , Humanos , Lactente , Resultado do Tratamento
10.
EuroIntervention ; 12(5): e652-7, 2016 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-27497366

RESUMO

AIMS: The feasibility of transcatheter closure of atrial septal defects (ASD) without fluoroscopy has been proven. However, the technique has not been accepted for routine use. We report our experience with trans-catheter closure of ASD without fluoroscopy and introduce a well-established technique for alternative use in children. METHODS AND RESULTS: From November 2013 to May 2015, a total of 114 children with isolated secundum ASD (diameter 6 mm to 24 mm, median 13.8 mm) underwent attempted transcatheter device closure under the guidance of transoesophageal echocardiography without fluoroscopy. Using a modified delivery system and procedure technique, ASD were successfully closed in 110 patients (96.5%, 52 males, 58 females, aged from three to 14 years, median 5.4 years, weight 12 to 46 kg, median 23.5 kg). Procedure time ranged from eight to 42 minutes (median 18 min). Three patients underwent percardiac device closure after failed procedures. In the early stage of our study, before delivery system and technique modification, one patient was converted to open heart surgery due to rupture of the left appendage. No intervention-related complications were detected during a median follow-up of nine months. CONCLUSIONS: Using a modified delivery system and a re-established procedure, we showed that transcatheter closure of ASD without fluoroscopy is a safe technique for alternative use in children.


Assuntos
Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana , Fluoroscopia , Comunicação Interatrial/cirurgia , Adolescente , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Ecocardiografia Transesofagiana/métodos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Resultado do Tratamento
11.
Heart Surg Forum ; 17(4): E187-90, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25179969

RESUMO

Closure of residual ventricular septal defect with an occluder is traditionally performed by a percutaneous transcatheter approach under radiographic guidance. However, this procedure may be of limited use in cases with unusually shaped defects and in patients with low body weight. Here, we report minimally invasive surgical device closure of a 6 mm residual ventricular septal defect under transesophageal echocardiographic guidance, in a patient weighing 10 kg that had previously undergone surgical correction of a double outlet right ventricle. The defect was positioned in the suture line between the Gore-Tex vascular graft and the remnant ventricular septum, and was unusual in that it formed a 135° angle with the Gore-Tex graft. The defect was closed successfully with a 10 mm asymmetric occluder. To the best of our knowledge, this is the first report of transesophageal echocardiography-guided minimally invasive surgical device closure of an unusually shaped residual ventricular septal defect after surgical correction of a double-outlet right ventricle.


Assuntos
Ecocardiografia Transesofagiana/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Dispositivo para Oclusão Septal , Cirurgia Assistida por Computador/métodos , Pré-Escolar , Humanos , Resultado do Tratamento
12.
Heart Surg Forum ; 17(4): E206-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25179974

RESUMO

BACKGROUND: The primary aim of this study was to explore the safety and feasibility of minimally invasive surgical device closure of perimembranous ventricular septal defects (PMVSDs) in children using echocardiography for preoperative assessment and intraoperative guidance. METHODS: We enrolled 942 children diagnosed with PMVSDs from April 2010 to October 2013. All children underwent full evaluation by transthoracic echocardiography (TTE) and multiplane transesophageal echocardiography (MTEE) to determine the sizes, types and spatial positions of defects and their proximity to the adjacent tissues. The PMVSDs were surgically occluded using MTEE for guidance. RESULTS: Eight hundred eighty-nine (94.37%) of 942 children underwent successful closure of PMVSDs. Symmetric devices were used in 741 children (including 38 A4B2 occluders) and asymmetric devices were used in the other 148. All patients received follow-ups at regular intervals after successful occlusion. The occluders remained firmly in place. No noticeable residual shunt or valvular regurgitation was discovered, with the exception of one child whose original mild aortic regurgitation progressed to moderate by the 18 month follow-up. Overall there were no significant arrhythmias with the exception of 3 children, all of whom experienced postsurgical acute attacks of Adams-Stokes syndrome. CONCLUSIONS: Minimally invasive surgical device closure of PMVSDs is safe and feasible. TTE and MTEE play vital roles in all stages of treatment of PMVSDs.


Assuntos
Ecocardiografia/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Dispositivo para Oclusão Septal , Cirurgia Assistida por Computador/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Resultado do Tratamento
13.
Heart Surg Forum ; 17(1): E25-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24631987

RESUMO

BACKGROUND: Severe congenital aortic stenosis in infants is a life-threatening congenital heart anomaly that is typically treated using percutaneous balloon aortic valvuloplasty. METHODS: The usual route is the femoral artery under radiographic guidance. However, this procedure may be limited by the small size of the femoral artery in low-weight infants. An infant weighing only 7 kg with severe aortic stenosis (peak gradient was 103 mmHg) was successfully treated with a novel approach, that is trans-ascending aorta balloon aortic valvuloplasty guided by transesophageal echocardiography. RESULTS: The patient tolerated the procedure well, and no major complications developed. After the intervention, transesophageal echocardiography indicated a significant reduction of the aortic valvular peak gradient from 103 mmHg to 22 mmHg, no aortic regurgitation was found. Eighteen months after the intervention, echocardiography revealed that the aortic valvular peak gradient had increased to 38 mmHg and that still no aortic regurgitation had occurred. CONCLUSIONS: In our limited experience, trans-ascending aorta balloon aortic valvuloplasty for severe aortic stenosis under transesophageal echocardiography guidance effectively reduces the aortic peak gradient. As this is a new procedure, long-term follow up and management will need to be established. It may be an alternative technique to treat congenital aortic stenosis in low-weight patients.


Assuntos
Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão/métodos , Ecocardiografia Transesofagiana/métodos , Ultrassonografia de Intervenção/métodos , Aorta/cirurgia , Estenose da Valva Aórtica/congênito , Humanos , Lactente , Masculino , Esternotomia/métodos , Resultado do Tratamento
14.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 38(6): 602-9, 2013 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-23828704

RESUMO

OBJECTIVE: To discuss the preoperative, intraoperative, and postoperative application of echocardiography in mini-invasive surgical device closure of secundum atrial septal defects, including those special and difficulty-occluded defects. METHODS: We performed mini-invasive surgical device closure of secundum atrial septal defects on 287 patients. Before the surgery, transthoracic echocardiography was applied for screening; during the surgery we reassessed the sizes of the defects and their remaining margins, designated the suitable occluders, and guided the placement of the occluders by multiplane transesophageal echocardiography. The patients were postoperatively followed up at regular intervals by multiplane transesophageal echocardiography (MTEE) which was employed to assess the therapeutic efficacy. RESULTS: Out of the 287 atrial septal defects, 276 (96.17%) were successfully closed. There were 37 porous defects and 23 cases with short posterior-inferior margin of defects. Follow-ups at intervals showed the occluders stayed firmly and echoed clearly. No notable residual shunt or valve regurgitation was observed. CONCLUSION: Echocardiography plays a vital and reliable role in mini-invasive surgical device closure of secundum atrial septal defects, especially those special and difficulty-occluded defects.


Assuntos
Comunicação Interatrial/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Dispositivo para Oclusão Septal , Ultrassonografia de Intervenção , Adolescente , Criança , Pré-Escolar , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Lactente , Masculino
15.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 38(5): 490-8, 2013 May.
Artigo em Chinês | MEDLINE | ID: mdl-23719524

RESUMO

OBJECTIVE: To discuss the suitable types of ventricular septal defects for asymmetric occluders, and elucidate the critical role of echocardiography in choosing occluders, guiding successful occlusion and avoiding injury during operation. METHODS: We retrospectively studied 179 patients with ventricular septal defects who received minimal-invasive surgical device closure with asymmetric occluder. We analyzed the types, size and morphology of ventricular septal defects suitable for asymmetric occluders. The therapeutic efficiency was evaluated by follow-ups. RESULTS: Out of the 179 successful cases treated with asymmetric occluders, 86.59% had perimembranous ventricular septal defects, and double-committed sub-arterial ventricular septal defects accounted for 13.41%. In general, the size of occluders to be selected was the maximum diameter of the defects plus 2-3 mm. Follow-ups showed that occluders were placed and fixed properly. No severe residual shunt, valve regurgitation or heart block were discovered. CONCLUSION: Application of asymmetric occluders expands the range of indications for occlusion via small chest incision. Accurate echocardiography helps to improve the safety and successful rate of the surgery.


Assuntos
Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Dispositivo para Oclusão Septal , Adolescente , Criança , Pré-Escolar , Ecocardiografia Doppler em Cores , Feminino , Comunicação Interventricular/diagnóstico por imagem , Humanos , Lactente , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA