Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Med (Lausanne) ; 10: 1289522, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38213912

RESUMO

Objectives: Ovarian leiomyomas (OLs) are rare and account for only 0.5 to 1% of benign ovarian tumors. This study investigated the ultrasonographic manifestations of OL and the potential reasons for misdiagnosis. Methods: Between July 2018 and July 2023, 7 patients diagnosed with OL by surgical pathology and immunohistochemistry were enrolled in this retrospective analysis. Ultrasound (US) examinations were performed before surgery. Clinical characteristics, pathological findings, ultrasonographic manifestations, and treatment were reviewed. Results: The mean age of the 7 patients was 39.0 ± 11.57 years, with a disease course of 0.1 to 24 months. All ovarian leiomyomas were unilateral. Four cases occurred in the right ovary, and three cases occurred in the left ovary. All lesions presented as hypoechogenic, well-circumscribed, round or oval in shape, and regular in morphology. No significant blood flow signal was detected peripheral to or inside the mass in 3 cases (42.8%), and a minimal flow signal was detected peripheral to or inside the mass in 4 cases (58.2%). A total of 7 ultrasonographic images of OL were misdiagnosed: 1 patient was misdiagnosed with subserosal uterine leiomyoma, and 6 patients were misdiagnosed with a tumor in the ovarian thecoma-fibroma group. Conclusion: The imaging manifestation of OL lacks specificity; thus, preoperatively distinguishing OL from other ovarian tumors and subserosal uterine leiomyomas is difficult. Immunohistochemistry may be helpful for the definitive diagnosis of OL. The possibility of ovarian leiomyoma should be considered in patients with uterine leiomyomas coexisting with an adnexal ovarian solid mass.

2.
J Clin Ultrasound ; 50(4): 564-572, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35318682

RESUMO

OBJECTIVES: To describe a facilitated procedure of colorectal filling contrast ultrasonography (CFCUS) and explore its value in the diagnosis of pediatric juvenile polyps. METHODS: One hundred and eleven children with clinical signs of colorectal polyps admitted to our hospital between May 2018 and May 2021 were retrospectively reviewed. All children underwent conventional transabdominal ultrasonography (CTUS) and CFCUS prior to undergoing colonoscopy. Pathologic findings were used as the gold standard. Chi-squared tests and Mann-Whitney U tests were used for the statistical analysis. RESULTS: Forty-five children with fifty-two colorectal polyps were confirmed via pathological examination. The sensitivity, specificity, positive predictive value, and negative predictive value of CFCUS vs. CTUS were 92.3% versus 80.7%, 100% versus 100%, 100% versus 100%, and 93.3% versus 84.8%, respectively. The missed polyps were significantly smaller than the polyps detected in diameter (7.50 ± 2.12 mm vs. 19.62 ± 7.89 mm, p < 0.0001) by CTUS. A significant difference between CTUS and CFCUS was observed in the detection rate of polyps with a diameter < 1 cm (p = 0.031) and pedicles (p < 0.001). The kappa values for the assessment of Yamada's classification between CTUS and colonoscopy and CFCUS and colonoscopy were 0.51 and 0.84, respectively. Moreover, CFCUS incidentally revealed a punctate hyperechoic area on the surface of colonic polyps in six cases, which may be suggestive of a correlation with erosion and bleeding findings. CONCLUSION: CFCUS can increase the detection rate of polyps and pedicles, especially polyps with diameters <1 cm, and accurately evaluate Yamada's classification, providing useful preoperative information for colonoscopy.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Criança , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia/métodos
3.
J Cancer ; 11(13): 3903-3909, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32328194

RESUMO

Objectives: To assess the performance of elastography (ES) and ultrasound (US) in predicting the malignancy of breast lesions and to compare their combined diagnostic value with that of magnetic resonance imaging (MRI). Materials and Methods: The study prospectively enrolled 242 female patients with dense breasts treated in 35 heath care facilities in China between November 2018 and October 2019. Based on conventional US and elastography, radiologists classified the degree of suspicion of breast lesions according to the US Breast Imaging Reporting and Data System (BI-RADS) criteria. The diagnostic value was compared between US BI-RADS and MRI BI-RADS, with pathological results used as the reference standard. Results: The results demonstrated that irregular tumor shape, a nonparallel growth orientation, indistinct margins, angular contours, microcalcifications, color Doppler flow and ES score on US imaging were significantly related to breast cancer in dense breasts (P=0.001; P=0.001; P=0.008; P<0.001; P=0.019; P=0.008; P=0.002, respectively). The sensitivity, specificity, PPV, NPV, accuracy and AUC of US BI-RADS category were 94.7%, 90.7%, 95.8%, 88.0%, 93.4% and 0.93 (95%CI, 0.88-0.97), respectively, while those of MRI BI-RADS category were 98.2%, 57.5%, 84.3%, 83.3%, 86.0% and 0.78 (95%CI, 0.71-0.85), respectively. MRI BI-RADS showed a significantly higher sensitivity than US BI-RADS (98.2% vs 94.7%, P=0.043), whereas US BI-RADS showed significantly higher specificity (90.7% vs 57.5%, P<0.001). US BI-RADS showed better diagnostic efficiency in differentiating nodules in dense breasts than MRI BI-RADS (AUC 0.93 vs 0.78, P<0.001). Conclusion: By combining the use of ES and conventional US, US BI-RADS had better diagnostic efficiency in differentiating nodules in dense breasts than MRI. For the diagnosis of malignant tumors in patients with dense breasts, MRI and US BI-RADS can be used as supplemental diagnostic tools to detect lesions, with US BI-RADS considered the preferred adjunctive resource.

4.
Exp Ther Med ; 7(5): 1396-1402, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24940446

RESUMO

The aim of the present study was to explore the feasibility of enhancing green fluorescent protein (EGFP) gene transfection into the synovial joint tissues of rats with rheumatoid arthritis (RA) by ultrasound-mediated microbubble destruction. An optimal SonoVue dose was determined using 40 normal rats categorized into five groups according to the various doses of microbubbles used. At 1 week after ultrasound irradiation, the rats were sacrificed. Damage to the joint synovial tissues was observed with hematoxylin and eosin histopathological staining under a microscope. A further 44 normal rats were used to establish a rat model of RA, and were then categorized into four groups: EGFP, ultrasound + EGFP, microbubbles + EGFP and ultrasound + microbubbles + EGFP. The last group was irradiated with ultrasound for 10 min following the injection of 300 µl SonoVue and 10 µg EGFP into the joint cavity. Rats were sacrificed after 3 days and synovial tissue was collected from the knee joints for observation of EGFP with fluorescence microscopy and analysis by quantitative polymerase chain reaction. EGFP expression was observed in the synovial tissues of all groups. However, high EGFP expression levels were observed in the ultrasound + microbubbles + EGFP group. No statistically significant differences (P>0.05) were observed in the EGFP expression levels between the EGFP, ultrasound + EGFP and microbubbles + EGFP groups. However, EGFP expression levels in the EGFP, ultrasound + EGFP and microbubbles + EGFP groups significantly differed (P<0.05) from that in the ultrasound + microbubbles + EGFP group. Therefore, ultrasound-mediated microbubble destruction improved EGFP transfection efficiency into the joint synovial tissues of rats with RA.

5.
Clin Imaging ; 32(3): 178-82, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18502344

RESUMO

OBJECTIVE: The objective of this study was to noninvasively evaluate the severity of renal ischemia-reperfusion (I-R) injury in rabbits with microbubbles targeted to activated neutrophils [phosphatidylserine-conjugated surfactant perfluoropropane-filled microbubbles (SPMB-PS)]. METHODS: Microbubbles targeted to activated neutrophils (SPMB-PS) were prepared by conjugating phosphatidylserine (PS) to self-assembling surfactant perfluoropropane-filled microbubbles (SPMB). Flow cytometry was performed to assess the presence of PS in SPMB. A renal I-R injury model was established in 18 rabbits for contrast-enhanced ultrasonography. Examination of ultrasonography with SPMB-PS and SPMB was performed on 12 rabbits before and after I-R injury. The time-intensity curve (TIC) was generated from a selected region of interest. Another six rabbits with renal I-R injury underwent contrast-enhanced ultrasonography for 15 min after intravenous injection of SPMB-PS. The renal tissues were immediately excised for immunohistochemical staining and myeloperoxidase (MPO) activity analysis. The correlation between MPO activity and echo intensity (VI) was analyzed. RESULTS: Flow cytometry demonstrated that PS was located on the surface of SPMB. TIC showed that the time at which the maximum VI was reached and the time needed for the microbubbles to wash out were the same in the normal kidneys injected with SPMB-PS or SPMB, while there was an obvious delay in emptying time with SPMB-PS compared with SPMB after I-R injury. Fifteen minutes after the injection of SPMB-PS and SPMB, VI was not remarkably different (P>.05) in the normal kidneys, while it was significantly higher (P<.01) in the I-R-injured kidneys. There was a strong correlation between MPO activity and VI 15 min after the injection of SPMB-PS (r=.933, P<.01). Immunohistochemistry showed that most of the inflammatory cells in the I-R-injured kidneys were neutrophils. CONCLUSION: A delayed emptying phenomenon was observed during contrast-enhanced ultrasonography in the I-R-injured kidneys, with SPMB-PS targeted to activated neutrophils. Therefore, contrast-enhanced ultrasonography with SPMB-PS may noninvasively evaluate the severity of ischemia-reperfusion injury to the kidneys.


Assuntos
Aumento da Imagem/métodos , Nefropatias/diagnóstico por imagem , Nefropatias/patologia , Traumatismo por Reperfusão/diagnóstico por imagem , Traumatismo por Reperfusão/patologia , Animais , Meios de Contraste , Modelos Animais de Doenças , Estudos de Avaliação como Assunto , Citometria de Fluxo , Imuno-Histoquímica , Microbolhas , Infiltração de Neutrófilos , Peroxidase/metabolismo , Coelhos , Circulação Renal/fisiologia , Sensibilidade e Especificidade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA