RESUMO
BACKGROUND: Over the past three decades, the use of ultrasonically activated device (USAD) and advanced bipolar device (ABD) has grown in minimally invasive surgeries. However, the thermal profile differences during repeated dissection with different grasping ranges of energy devices, which provide valuable information for preventing thermal injury by energy devices, remain unclear. METHODS: We developed an ex vivo benchtop model to examine the temperature profile of the blade and jaws of two USADs (HARMONIC® ACE + and Sonicision™) and a ABD (Ligasure™ Maryland) with different grasping ranges (partial tissue and full tissue bite) in repeated dissection with minimum cooling time. The maximum temperature, time required for completion to dissection of 10 cm of porcine muscle, thermal spread, and cooling time to reach 60 °C were continuously measured using video thermography. In addition, to evaluate one more grasping range "no tissue", we performed a stress test that activated the USAD without tissue intervention to assess the effects of excessive load on the blade and jaw. RESULTS: Repeated dissection of energy devices with minimal cooling time results in high blade and jaw temperatures proportional to the incision distance. In particular, the USADs with partial tissue bite showed a significantly higher temperatures at the blade and jaw, longer cooling times, and higher lateral thermal spread than those with a full tissue bite and the ABD. The stress test with a USAD showed an extremely high blade temperature exceeding 400 °C, with the tissue pad melting only 13.2 s after activation. CONCLUSION: Although USAD with partial tissue bite help ensure precise dissection, repeated long activation with inadequate cooling time may increase the risk of thermal injury during surgery. These results suggest that surgeons should use energy devices properly while understanding the risks of adjacent organ damage that could result from abuse of the device.
Assuntos
Dissecação , Instrumentos Cirúrgicos , Animais , Temperatura Alta , Procedimentos Cirúrgicos Minimamente Invasivos , Suínos , TemperaturaRESUMO
BACKGROUND: The present study compared the short-term outcomes and costs of laparoscopic distal gastrectomy (LDG) with those of open distal gastrectomy (ODG) for gastric cancer using a nationwide administrative database in Japan. METHOD: Overall, 37,752 patients with gastric cancer who underwent distal gastrectomy at 1074 hospitals in the fiscal year 2012-2013 were evaluated using a diagnosis procedure combination database in Japan. We performed a retrospective analysis via a multilevel analysis (MLA) of the short-term surgical results and costs of the LDG and ODG groups. The models included the age, sex, comorbid complications, smoking, body mass index (BMI), activity of daily living (ADL), stage, and the number of cases of gastrectomy per facility for adjustment. The in-hospital mortality relative to the hospital volume was also compared. RESULTS: The LDG group required postoperative blood transfusion less frequently and had fewer postoperative complications, shorter hospitalization, and lower operative mortality than the ODG group. While this stage did not correlate with the in-hospital mortality, the surgical method, age, sex, ADL, BMI, comorbidity, and yearly volume showed a correlation. A significant association in the in-hospital mortality was observed between low- and very-high-volume hospitals. CONCLUSION: In this large nationwide cohort of patients with gastric cancer using an MLA, LDG was shown to be safer with lower mortality and postoperative complication rates than ODG.
Assuntos
Laparoscopia , Neoplasias Gástricas , Gastrectomia , Humanos , Japão/epidemiologia , Análise Multinível , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Resultado do TratamentoRESUMO
The case presented herein was a 70-year-old woman who had no compliant, but had a mass in the lower part of the right lobe of the thyroid detected by ultrasound (US). The US image of the tumor, measuring 13 mm in diameter, showed a low and heterogeneous internal echo level with calcification and an irregular margin. The tumor appeared to extend to the adjacent sternothyroid muscle, and cervical lymph node swelling was detected in a computer tomography (CT) image, but no metastatic lesion was found by positron emission tomography (PET)-CT. In a fine needle aspiration cytology of the tumor, papillary thyroid carcinoma was suggested because of the atypical epithelial cells having some changes other than intranuclear inclusion bodies. A subtotal thyroidectomy and central neck lymph node dissection were performed. The excised tumor was histologically composed of irregular nests or sheets of atypical squamoid epithelial cells with some ductal structures that leached to the sternothyroid muscle and involved the right lower parathyroid gland. Carcinoma showing thymus-like differentiation (CASTLE) was diagnosed histopathologically and immunohistochemically with the following immunohistochemical results: Cluster of differentiation 5 (CD5) (+), tumor protein p63 (p63) (+), KIT proto-oncogene receptor tyrosine kinase (c-KIT(CD117)) (+), thyroglobulin (-), and thyroid transcription factor-1 (TTF-1) (-). CASTLE is a rare carcinoma of the thyroid that architecturally resembles thymic epithelial tumors. Many CASTLE patients have been misdiagnosed as other carcinomas, such as anaplastic carcinoma, poorly differentiated carcinoma or squamous cell carcinoma of the thyroid. Immunohistochemical examination, including CD5 played an important role in the final diagnosis of CASTLE, although the distinction from diagnosis as squamous cell carcinoma or mucoepidermoid carcinoma in Hematoxylin-Eosin staining was challenging in our case. Nodal metastasis and perithyroidal tumor extension of CASTLE can predict its worse prognosis. Thus, at least careful follow-up studies are mandatory in cases of CASTLE.
Assuntos
Diferenciação Celular , Neoplasias do Timo/patologia , Glândula Tireoide/patologia , Idoso , Feminino , Humanos , Proto-Oncogene Mas , Neoplasias do Timo/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagemRESUMO
A 61-year-old woman was referred to our hospital because of a right breast mass. A 19 mm hard mass was palpable in the A area of the right breast. A contrast-enhanced MRI showed rim enhancement at the peripheral region of the tumor, which was thought to represent the carcinoma component mainly at the periphery and the matrix component inside the tumor. A low density mass with rim enhancement at the peripheral region was observed in a contrast-enhanced CT, the same as in the MRI. Neither axillary lymph node metastasis nor distant metastasis was observed. A core needle biopsy of the tumor lead to a diagnosis of matrix-producing carcinoma (MPC). A breast-conserving mastectomy with sentinel lymph nodes biopsy was performed on the right breast MPC (T1c, N0, M0 Stage I). Histopathologically, the tumor demonstrated overt carcinoma with direct transition to a cartilaginous or osseous matrix and lacked an intervening spindle cell component. Immunohistochemistry showed estrogen receptor (ER) (-), progesterone receptor (PgR) (-), human epidermal growth factor receptor 2 (HER2) (-), and Ki67 index of 50%, so-called triple negative breast cancer. The tumor was also positive for SRY-related HMG box-9 (SOX9), which is a useful marker of chondroid differentiation in normal and neoplastic tissues. The patient lived free from recurrence for 5 years, even though her adjuvant therapy was only radiation therapy without adjuvant chemotherapy. MPC is an uncommon and relatively rare variant of metaplastic carcinoma, and the prognosis for patients with MPC is poorer than that for patients with ordinary breast cancer. Here we report a case of MPC of the breast with characteristic rim enhancement in contrast-enhanced MRI and CT. The intrinsic subtype and prognosis of MPC is controversial, and then we may need more experience with MPC cases.