Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Biomed Opt ; 29(4): 046003, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38650893

RESUMO

Significance: Current methods for wound healing assessment rely on visual inspection, which gives qualitative information. Optical methods allow for quantitative non-invasive measurements of optical properties relevant to wound healing. Aim: Spatial frequency domain imaging (SFDI) measures the absorption and reduced scattering coefficients of tissue. Typically, SFDI assumes homogeneous tissue; however, layered structures are present in skin. We evaluate a multi-frequency approach to process SFDI data that estimates depth-specific scattering over differing penetration depths. Approach: Multi-layer phantoms were manufactured to mimic wound healing scattering contrast in depth. An SFDI device imaged these phantoms and data were processed according to our multi-frequency approach. The depth sensitive data were then compared with a two-layer scattering model based on light fluence. Results: The measured scattering from the phantoms changed with spatial frequency as our two-layer model predicted. The performance of two δ-P1 models solutions for SFDI was consistently better than the standard diffusion approximation. Conclusions: We presented an approach to process SFDI data that returns depth-resolved scattering contrast. This method allows for the implementation of layered optical models that more accurately represent physiologic parameters in thin tissue structures as in wound healing.


Assuntos
Imagens de Fantasmas , Espalhamento de Radiação , Pele , Pele/diagnóstico por imagem , Pele/química , Humanos , Modelos Biológicos , Luz , Cicatrização/fisiologia , Imagem Óptica/métodos , Processamento de Imagem Assistida por Computador/métodos
2.
Eur J Prev Cardiol ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38333959

RESUMO

AIM: The aim was to investigate the relationship between microvascular function, cardiovascular risk profile, and subclinical atherosclerotic burden. METHODS: The study enrolled 3809 individuals, 50-65 years old, participating in the population-based observational cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS). Microvascular function was assessed in forearm skin using an arterial occlusion and release protocol determining peak blood oxygen saturation (OxyP). Cardiovascular risk was calculated using the updated Systematic Coronary Risk Evaluation (SCORE2; 10-year risk of fatal and non-fatal CVD events). OxyP was compared with Coronary Artery Calcification Score (CACS) and to plaques in the carotid arteries. RESULTS: Individuals with OxyP values in the lowest quartile (Q1; impaired microvascular function), had a mean SCORE2 of 5.8% compared to 3.8% in those with the highest values of OxyP (Q4), a relative risk increase of 53%. The risk of having a SCORE2 > 10% was 5 times higher for those in Q1 (OR: 4.96 95% CI: 2.76-8.93) vs. Q4 when adjusting for BMI and hsCRP. OxyP was lower in individuals with CACS > 0, and in those with both carotid plaques and CACS >0, =compared with individuals without subclinical atherosclerotic burdens (87.5 ± 5.6% and 86.9 ± 6.0%, vs 88.6 ± 5.8%, p < 0.01). CONCLUSION: In a population without cardiovascular disease or diabetes mellitus, impaired microvascular function is associated with cardiovascular risk profiles such as higher SCORE2 risk and CACS. We suggest that OxyP may serve as a microcirculatory functional marker of subclinical atherosclerosis and CVD risk, that is not detected by structural assessments.


Impaired microvascular function was associated with higher cardiovascular risk profile SCORE2 and subclinical atherosclerotic burden defined by carotid plaque and coronary artery calcification (CACS).­ Individuals with impaired microvascular function (peak oxygen saturation in forearm skin, OxyP, after a prolonged arterial occlusion provocation), had a moderate risk level of SCORE2 compared to low risk level in those with the highest values of OxyP.­ OxyP was lower in individuals with CACS > 0, and in those with both carotid plaques and CACS >0, =compared with individuals with carotid plaque only and in individuals without subclinical atherosclerotic burdens.

3.
J Biomed Opt ; 28(11): 115001, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38078153

RESUMO

Significance: Knowledge of optical properties is important to accurately model light propagation in tissue, but in vivo reference data are sparse. Aim: The aim of our study was to present in vivo skin optical properties from a large Swedish cohort including 3809 subjects using a three-layered skin model and spatially resolved diffuse reflectance spectroscopy (Periflux PF6000 EPOS). Approach: Diffuse reflectance spectra (475 to 850 nm) at 0.4 and 1.2 mm source-detector separations were analyzed using an inverse Monte Carlo method. The model had one epidermis layer with variable thicknesses and melanin-related absorptions and two dermis layers with varying hemoglobin concentrations and equal oxygen saturations. The reduced scattering coefficient was equal across all layers. Results: Median absorption coefficients (mm-1) in the upper dermis ranged from 0.094 at 475 nm to 0.0048 at 850 nm and similarly in the lower dermis from 0.059 to 0.0035. The reduced scattering coefficient (mm-1) ranged from 3.22 to 1.20, and the sampling depth (mm) ranged from 0.23 to 0.38 (0.4 mm separation) and from 0.49 to 0.68 (1.2 mm separation). There were differences in optical properties across sex, age groups, and BMI categories. Conclusions: Reference material for skin optical properties is presented.


Assuntos
Epiderme , Modelos Biológicos , Humanos , Estudos de Coortes , Suécia , Espalhamento de Radiação , Epiderme/diagnóstico por imagem , Derme/diagnóstico por imagem , Método de Monte Carlo
4.
Front Physiol ; 13: 926940, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35864897

RESUMO

Introduction: Takayasu arteritis (TAK) is a rare inflammatory disease affecting aorta and its major branches. Ultrasound (US) can detect inflammatory features in the arterial wall, but less is known regarding skin microcirculation and vascular hemodynamics. The aim was to study if assessment of these variables could add valuable information regarding vascular affection in TAK. Methods: 17 patients diagnosed with TAK and 17 age- and sex-matched healthy controls were included. Microcirculatory peak oxygen saturation (OxyP) in the skin after induced ischemia was evaluated with laser Doppler flowmetry/diffuse reflectance spectroscopy. Cerebrovascular reserve capacity (CVR) in the brain was assessed with transcranial Doppler (TCD). Pulse waves were recorded in the radial artery by the aid of applanation tonometry, for calculation of central augmentation index (AIx75). Intima-media thickness (IMT) and stenosis/occlusions were evaluated using US in carotid and central arteries. Results: Reduced OxyP (79 ± 8% vs. 87 ± 4%, p < 0.001) was seen in patients with TAK regardless of significant arterial stenosis/occlusion or not. Increased AIx75 (22.3 ± 13.6 vs. 9.2 ± 16.3, p = 0.01) was seen in TAK patients without significant stenosis/occlusions. No differences were found in CVR, regardless of proximal stenosis. However, signs of a more high-resistance flow profile were seen in arteria cerebri media. Conclusion: Regardless of arterial stenosis or not, impaired microcirculation of the skin and preserved CVR in the brain were found in subjects with TAK. Signs of increased arterial stiffness in the brain and central arteries were observed. The value of these findings for prediction of future cardiovascular events needs to be clarified in further studies.

5.
Vaccines (Basel) ; 10(4)2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35455332

RESUMO

The high-density microneedle array patch (HD-MAP) is a promising alternative vaccine delivery system device with broad application in disease, including SARS-CoV-2. Skin reactivity to HD-MAP applications has been extensively studied in young individuals, but not in the >65 years population, a risk group often requiring higher dose vaccines to produce protective immune responses. The primary aims of the present study were to characterise local inflammatory responses and barrier recovery to HD-MAPs in elderly skin. In twelve volunteers aged 69−84 years, HD-MAPs were applied to the forearm and deltoid regions. Measurements of transepidermal water loss (TEWL), dielectric permittivity and erythema were performed before and after HD-MAP application at t = 10 min, 30 min, 48 h, and 7 days. At all sites, TEWL (barrier damage), dielectric permittivity (superficial water);, and erythema measurements rapidly increased after HD-MAP application. After 7 days, the mean measures had recovered toward pre-application values. The fact that the degree and chronology of skin reactivity and recovery after HD-MAP was similar in elderly skin to that previously reported in younger adults suggests that the reactivity basis for physical immune enhancement observed in younger adults will also be achievable in the older population.

6.
J Biomed Opt ; 27(7)2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35106979

RESUMO

SIGNIFICANCE: Tissue simulating phantoms are an important part of validating biomedical optical techniques. Tissue pathology in inflammation and oedema involves changes in both water and hemoglobin fractions. AIM: We present a method to create solid gelatin-based phantoms mimicking inflammation and oedema with adjustable water and hemoglobin fractions. APPROACH: One store-bought gelatin and one research grade gelatin were evaluated. Different water fractions were obtained by varying the water-to-gelatin ratio. Ferrous stabilized human hemoglobin or whole human blood was added as absorbers, and the stability and characteristics of each were compared. Intralipid® was used as the scatterer. All phantoms were characterized using spatial frequency domain spectroscopy. RESULTS: The estimated water fraction varied linearly with expected values (R2 = 0.96 for the store-bought gelatin and R2 = 0.99 for the research grade gelatin). Phantoms including ferrous stabilized hemoglobin stayed stable up to one day but had methemoglobin present at day 0. The phantoms with whole blood remained stable up to 3 days using the store-bought gelatin. CONCLUSIONS: A range of physiological relevant water fractions was obtained for both gelatin types, with the stability of the phantoms including hemoglobin differing between the gelatin type and hemoglobin preparation. These low-cost phantoms can incorporate other water-based chromophores and be fabricated as thin sheets to form multilayered structures.


Assuntos
Gelatina , Água , Gelatina/química , Hemoglobinas , Humanos , Inflamação , Microdiálise , Imagens de Fantasmas
7.
Microvasc Res ; 140: 104284, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34826433

RESUMO

The objective of this study was to explore the associations between skin microcirculatory function and established cardiovascular risk factors in a large Swedish cohort. As part of the Swedish CArdioPulmonary bioImage Study (SCAPIS), microcirculatory data were acquired at Linköping University hospital, Linköping, Sweden during 2016-2017. The subjects, aged 50-64 years, were randomly selected from the national population register. Microcirculatory reactivity was assessed using a 5-min arterial occlusion-release protocol. Comprehensive skin microcirculatory data were continuously acquired by using a fiberoptic probe placed on the lower right arm. After exclusion of missing data (208), 1557 subjects were remaining. Among the parameters, skin microcirculatory peak oxygen saturation after occlusion release, had the strongest relationship to the cardiovascular risk factors. The linear associations between peak oxygen saturation and cardiovascular risk factors were analyzed adjusted for age and sex. We found a negative association with peak oxygen saturation (standardized regression coefficient) for blood pressure (systolic -0.05 (95% CI: -0.10;-0.003) and diastolic -0.05 (-0.10; -0.003)), BMI -0.18 (-0.23; -0.13), waist circumference (males -0.20 (-0.32; -0.16), females -0.18 (-0.25; -0.11)), prevalent diabetes -0.31 (-0.49; -0.12), hypertension -0.30 (-0.42; -0.18), dyslipidemia -0.24 (-0.40; -0.09), fasting glucose level -0.06 (-0.12; -0.01), HbA1c -0.07 (-0.12; -0.02), triglyceride level -0.09 (-0.14; -0.04), hsCRP -0.12 (-0.17; -0.07), and current smoker versus never smoked -0.50 (-0.67; -0.34). A positive association with peak oxygen saturation was found for cholesterol level 0.05 (0.005; 0.11) and HDL 0.11 (0.06; 0.17). This is the first study showing that post-ischemic skin microvascular peak oxygen saturation is associated with virtually all established cardiovascular risk factors in a population-based middle-aged cohort.


Assuntos
Isquemia/sangue , Microcirculação , Saturação de Oxigênio , Oxigênio/sangue , Pele/irrigação sanguínea , Biomarcadores/sangue , Estudos Transversais , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Isquemia/diagnóstico , Isquemia/epidemiologia , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Oxiemoglobinas/metabolismo , Fluxo Sanguíneo Regional , Medição de Risco , Suécia/epidemiologia
8.
Front Med (Lausanne) ; 8: 722758, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34790671

RESUMO

Introduction: Systemic lupus erythematosus (SLE) is associated with premature cardiovascular disease (CVD) and mortality, unexplained by traditional risk factors. Impairment of microcirculation and vascular hemodynamics may represent early signs of vascular affection. We hypothesized that studies of microcirculation and pulse waves may provide additional information, compared to ultrasound (US) alone, for the detection of early vascular disease in SLE. Methods: Sixty well-characterized SLE-patients (52 women, eight men; mean age 43.21 ± 1.3 years) characterized by lupus nephritis (LN; n = 20), antiphospholipid syndrome (APS; n = 20) or skin and joint involvement (n = 20) and 60 healthy controls were included. Microcirculatory peak oxygen saturation (OxyP) was evaluated using a novel combined laser Doppler flowmetry/diffuse reflectance spectroscopy method. Pulse waves were recorded in the radial artery by the aid of applanation tonometry in order to calculate central augmentation index (AIx75). Intima-media thickness (IMT) and plaque occurrence were evaluated using high frequency US, in carotid and central arteries. Results: Lower OxyP (84 ± 8 vs. 87 ± 5 %, p = 0.01) and higher AIx75 (17.3 ± 13.9 vs. 10.0 ± 14.2 %, p = 0.005) were seen in the SLE cohort. OxyP was inversely correlated with IMT in internal carotid artery (ICA), (R = -0.32, p = 0.01). AIx75 correlated with IMT in common carotid artery (CCA), (R = 0.36, p = 0.005), common femoral artery (CFA), (R = 0.43, p = 0.001), and ICA (R = 0.27, p = 0.04). AIx75 correlated negatively with OxyP (R = -0.29, p = 0.02). SLE-patients with plaque had lower OxyP values (80 ± 8 vs. 85 ± 7 %, p < 0.001) and higher AIx75 (23.0 ± 11.6 vs. 15.5 ± 14.2 %, p < 0.001) compared to those without plaque. Conclusion: Impaired microcirculation and vessel hemodynamics were observed in SLE. These methods correlated with IMT and plaque occurrence. The importance of early macro- and micro-circulatory vascular affection for increased risk of CVD in SLE will be followed-up in future studies.

9.
J Biomed Opt ; 25(8): 1-12, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32755076

RESUMO

SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a quantitative imaging method to measure absorption and scattering of tissue, from which several chromophore concentrations (e.g., oxy-/deoxy-/meth-hemoglobin, melanin, and carotenoids) can be calculated. Employing a method to extract additional spectral bands from RGB components (that we named cross-channels), we designed a handheld SFDI device to account for these pigments, using low-cost, consumer-grade components for its implementation and characterization. AIM: With only three broad spectral bands (red, green, blue, or RGB), consumer-grade devices are often too limited. We present a methodology to increase the number of spectral bands in SFDI devices that use RGB components without hardware modification. APPROACH: We developed a compact low-cost RGB spectral imager using a color CMOS camera and LED-based mini projector. The components' spectral properties were characterized and additional cross-channel bands were calculated. An alternative characterization procedure was also developed that makes use of low-cost equipment, and its results were compared. The device performance was evaluated by measurements on tissue-simulating optical phantoms and in-vivo tissue. The measurements were compared with another quantitative spectroscopy method: spatial frequency domain spectroscopy (SFDS). RESULTS: Out of six possible cross-channel bands, two were evaluated to be suitable for our application and were fully characterized (520 ± 20 nm; 556 ± 18 nm). The other four cross-channels presented a too low signal-to-noise ratio for this implementation. In estimating the optical properties of optical phantoms, the SFDI data have a strong linear correlation with the SFDS data (R2 = 0.987, RMSE = 0.006 for µa, R2 = 0.994, RMSE = 0.078 for µs'). CONCLUSIONS: We extracted two additional spectral bands from a commercial RGB system at no cost. There was good agreement between our device and the research-grade SFDS system. The alternative characterization procedure we have presented allowed us to measure the spectral features of the system with an accuracy comparable to standard laboratory equipment.


Assuntos
Diagnóstico por Imagem , Pele , Hemoglobinas/análise , Imagens de Fantasmas , Pele/química , Pele/diagnóstico por imagem , Análise Espectral
10.
Am J Physiol Heart Circ Physiol ; 318(4): H908-H915, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32142355

RESUMO

The objective of this study was to assess normative values for comprehensive forearm skin microcirculatory function: oxygen saturation, tissue fraction of red blood cells (RBCs), and speed-resolved perfusion. Furthermore, to examine the influence of age and sex on microcirculatory function. Measurements were performed using a noninvasive probe-based system, including diffuse reflectance spectroscopy and laser-Doppler flowmetry, yielding output data in absolute units. The study was conducted within the Swedish CArdioPulmonary BioImage Study (SCAPIS) and included 1,765 men and women aged 50-65 yr from the Linköping general population. Normative values are given at baseline, at the end of a 5-min occlusion of the brachial artery and during hyperemia after occlusion release. We found a consistent age distribution, in which the oldest individuals had the lowest peak oxygen saturation (P < 0.001) and the highest baseline low-speed perfusion (P < 0.001). Women had higher peak oxygen saturation (P < 0.001), lower RBC tissue fraction, in general (P < 0.001), lower baseline perfusion in all speed regions (P = 0.01), and lower peak high-speed perfusion at hyperemia (P < 0.001). The normative data can be used as reference values in future studies of disease-specific populations. The results show that age and sex are important aspects to consider in studies of microvascular function. Women and younger age were factors associated with higher peak oxygen saturation after ischemia. This is a novel parameter that reflects overall microcirculatory function associated with vascular dilation capacity.NEW & NOTEWORTHY This study expands experimental microcirculatory research to clinical use by providing normative values on microcirculatory function in a large population-based cohort. Women and younger age were factors associated with higher peak oxygen saturation after ischemia, which implies that age and sex are important aspects to consider in studies of microvascular function. This study is the first step toward using microcirculatory assessment as a tool to improve diagnosis, prognosis, and treatment in disease-specific populations.


Assuntos
Fluxometria por Laser-Doppler/normas , Microcirculação , Pele/irrigação sanguínea , Fatores Etários , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Valores de Referência , Fluxo Sanguíneo Regional , Fatores Sexuais
11.
J Biomed Opt ; 24(9): 1-8, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31512441

RESUMO

The PeriFlux 6000 EPOS system combines diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF) for the assessment of oxygen saturation (expressed in percentage), red blood cell (RBC) tissue fraction (expressed as volume fraction, %RBC), and perfusion (%RBC × mm / s) in the microcirculation. It also allows the possibility of separating the perfusion into three speed regions (0 to 1, 1 to 10, and >10 mm / s). We evaluate the speed-resolved perfusion components, i.e., the relative amount of perfusion within each speed region, using a blood-flow phantom. Human blood was pumped through microtubes with an inner diameter of 0.15 mm. Measured DRS and LDF spectra were compared to Monte Carlo-simulated spectra in an optimization routine, giving the best-fit parameters describing the measured spectra. The root-mean-square error for each of the three speed components (0 to 1, 1 to 10, and >10 mm / s, respectively) when describing the blood-flow speed in the microtubes was 2.9%, 8.1%, and 7.7%. The presented results show that the system can accurately discriminate blood perfusion originating from different blood-flow speeds, which may enable improved measurement of healthy and dysfunctional microcirculatory flow.


Assuntos
Fluxometria por Laser-Doppler/instrumentação , Dispositivos Ópticos , Imagens de Fantasmas , Algoritmos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Hemodinâmica , Humanos , Fluxometria por Laser-Doppler/estatística & dados numéricos , Microcirculação , Método de Monte Carlo , Dispositivos Ópticos/estatística & dados numéricos , Fenômenos Ópticos , Oxigênio/sangue , Pele/irrigação sanguínea , Análise Espectral/instrumentação , Análise Espectral/estatística & dados numéricos
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6537-6540, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947339

RESUMO

Approximately 20-30% of all road fatalities are related to driver sleepiness. A long-lasting goal in driver state research has therefore been to develop a robust sleepiness detection system. Since the alertness level is reflected in autonomous nervous system activity, it has been suggested that various heart rate variability (HRV) metrics can be used as features for driver sleepiness classification. Since the heart rate is modulated by many different factors, and not just by sleepiness, it is relevant to question the high driver sleepiness classification accuracies that have occasionally been presented in the literature. The main objective of this paper is thus to test how well a sleepiness classification system based on HRV features really is. A unique data set with 86 drivers, obtained while driving on real roads in real traffic, both in alert and sleep deprived conditions, was used to train and test a support vector machine (SVM) classifier. Subjective ratings based on the Karolinska sleepiness scale (KSS) was used as ground truth to divide the data into three classes (alert, somewhat sleepy and severely sleepy). Even though nearly all the 24 investigated HRV metrics showed significant differences between sleepiness levels, the SVM results only reached a mean accuracy of 61 %, with the worst results originating from the severely sleepy cases. In summary, the high classification performance that may arise in studies with high experimental control could not be replicated under realistic driving conditions. Future works should focus on how various confounding factors should be accounted for when using HRV based metrics as input to a driver sleepiness detection system.


Assuntos
Condução de Veículo , Acidentes de Trânsito , Frequência Cardíaca , Humanos , Sono , Máquina de Vetores de Suporte , Vigília
13.
J Biomed Opt ; 23(12): 1-6, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30267487

RESUMO

We have determined in vivo optical scattering properties of normal human skin in 1734 subjects, mostly with fair skin type, within the Swedish CArdioPulmonary bioImage Study. The measurements were performed with a noninvasive system, integrating spatially resolved diffuse reflectance spectroscopy and laser Doppler flowmetry. Data were analyzed with an inverse Monte Carlo algorithm, accounting for both scattering, geometrical, and absorbing properties of the tissue. The reduced scattering coefficient was found to decrease from 3.16 ± 0.72 to 1.13 ± 0.27 mm-1 (mean ± SD) in the 475- to 850-nm wavelength range. There was a negative correlation between the reduced scattering coefficient and age, and a significant difference between men and women in the reduced scattering coefficient as well as in the fraction of small scattering particles. This large study on tissue scattering with mean values and normal variation can serve as a reference when designing diagnostic techniques or when evaluating the effect of therapeutic optical systems.


Assuntos
Diagnóstico por Imagem/métodos , Pele/diagnóstico por imagem , Algoritmos , Estudos de Coortes , Diagnóstico por Imagem/instrumentação , Feminino , Humanos , Fluxometria por Laser-Doppler , Luz , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Dispositivos Ópticos , Óptica e Fotônica , Valores de Referência , Espalhamento de Radiação , Pele/patologia , Suécia
14.
Diab Vasc Dis Res ; 14(4): 363-371, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28482676

RESUMO

Skin and kidney microvascular functions may be affected independently in diabetes mellitus. We investigated skin microcirculatory function in 79 subjects with diabetes type 2, where 41 had microalbuminuria and 38 not, and in 41 age-matched controls. The oxygen saturation, fraction of red blood cells and speed-resolved microcirculatory perfusion (% red blood cells × mm/s) divided into three speed regions: 0-1, 1-10 and above 10 mm/s, were assessed during baseline and after local heating of the foot with a new device integrating diffuse reflectance spectroscopy and laser Doppler flowmetry. Arterial stiffness was assessed as carotid-femoral pulse wave velocity. Subjects with diabetes and microalbuminuria had significantly higher carotid-femoral pulse wave velocity compared to subjects without microalbuminuria and to controls. The perfusion for speeds 0-1 mm/s and red blood cell tissue fraction were reduced in subjects with diabetes at baseline and after heating, independent of microalbuminuria. These parameters were correlated to HbA1c. In conclusion, the reduced nutritive perfusion and red blood cell tissue fraction in type 2 diabetes were related to long-term glucose control but independent of microvascular changes in the kidneys and large-vessel stiffness. This may be due to different pathogenic pathways in the development of nephropathy, large-vessel stiffness and cutaneous microvascular impairment.


Assuntos
Albuminúria/etiologia , Diabetes Mellitus Tipo 2/complicações , Angiopatias Diabéticas/etiologia , Nefropatias Diabéticas/etiologia , Endotélio Vascular/fisiopatologia , Rim/irrigação sanguínea , Microcirculação , Pele/irrigação sanguínea , Rigidez Vascular , Idoso , Albuminúria/diagnóstico , Albuminúria/fisiopatologia , Biomarcadores/sangue , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Angiopatias Diabéticas/diagnóstico , Angiopatias Diabéticas/fisiopatologia , Nefropatias Diabéticas/diagnóstico , Nefropatias Diabéticas/fisiopatologia , Eritrócitos/metabolismo , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Onda de Pulso , Fluxo Sanguíneo Regional , Circulação Renal , Fatores de Tempo
15.
Microvasc Res ; 102: 70-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26279347

RESUMO

We have developed a new fiber-optic system that combines diffuse reflectance spectroscopy (DRS) and laser Doppler Flowmetry (LDF) for a multi-modal assessment of the microcirculation. Quantitative data is achieved with an inverse Monte Carlo algorithm based on an individually adaptive skin model. The output parameters are calculated from the model and given in absolute units: hemoglobin oxygen saturation (%), red blood cell (RBC) tissue fraction (%), and the speed resolved RBC perfusion separated into three speed regions; 0-1mm/s, 1-10mm/s and above 10mm/s (% mm/s). The aim was to explore microcirculatory parameters using the new optical method, integrating DRS and LDF in a joint skin model, during local heating of the dorsal foot and venous and arterial occlusion of the forearm in 23 healthy subjects (age 20-28years). There were differences in the three speed regions in regard to blood flow changes due to local heating, where perfusion for high speeds increased the most. There was also a high correlation between changes in oxygenation and changes in perfusion for higher speeds. Oxygen saturation at baseline was 44% on foot, increasing to 83% at plateau after heating. The larger increase in perfusion for higher speeds than for lower speeds together with the oxygenation increase during thermal provocation, shows a local thermoregulatory blood flow in presumably arteriolar dermal vessels. In conclusion, there are improved possibilities to assess microcirculation using integrated DRS and LDF in a joint skin model by enabling both oxygenation and speed resolved blood flow assessment simultaneously and in the same skin site. Output parameters in absolute units may also yield new insights about the microcirculatory system.


Assuntos
Fluxometria por Laser-Doppler/métodos , Microcirculação/fisiologia , Oxigênio/sangue , Espectrofotometria/métodos , Adulto , Algoritmos , Velocidade do Fluxo Sanguíneo , Eritrócitos/fisiologia , Feminino , Tecnologia de Fibra Óptica , Temperatura Alta , Humanos , Masculino , Modelos Cardiovasculares , Método de Monte Carlo , Fluxo Sanguíneo Regional , Pele/irrigação sanguínea , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA