Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(24)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847169

RESUMO

A sensing configuration for the real-time monitoring, detection, and quantification of dissolved carbon dioxide (dCO2) was developed for aquaculture and other applications in freshwater and saline water. A chemical sensing membrane, based on a colorimetric indicator, is combined with multimode optical fiber and a dual wavelength light-emitting diode (LED) to measure the dCO2-induced absorbance changes in a self-referenced ratiometric scheme. The detection and processing were achieved with an embeded solution having a mini spectrometer and microcontroller. For optrode calibration, chemical standard solutions using sodium carbonate in acid media were used. Preliminary results in a laboratory environment showed sensitivity for small added amounts of CO2 (0.25 mg·L-1). Accuracy and response time were not affected by the type of solution, while precision was affected by salinity. Calibration in freshwater showed a limit of detection (LOD) and a limit of quantification (LOQ) of 1.23 and 1.87 mg·L-1, respectively. Results in saline water (2.5%) showed a LOD and LOQ of 1.05 and 1.16 mg·L-1, respectively. Generally, performance was improved when moving from fresh to saline water. Studies on the dynamics of dissolved CO2 in a recirculating shallow raceway system (SRS+RAS) prototype showed higher precision than the tested commercial sensor. The new sensor is a compact and robust device, and unlike other sensors used in aquaculture, stirring is not required for correct and fast detection. Tests performed showed that this new sensor has a fast accurate detection as well as a strong potential for assessing dCO2 dynamics in aquaculture applications.


Assuntos
Aquicultura/métodos , Dióxido de Carbono/análise , Águas Salinas/análise , Colorimetria , Monitoramento Ambiental/métodos , Fibras Ópticas
2.
Sensors (Basel) ; 19(7)2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-30925686

RESUMO

We present a portable and low-cost system for interrogation of long-period fiber gratings (LPFGs) costing around a 30th of the price of a typical setup using an optical spectrum analyzer and a broadband light source. The unit is capable of performing real-time monitoring or as a stand-alone data-logger. The proposed technique uses three thermally modulated fiber-coupled laser diodes, sweeping a few nanometers around their central wavelength. The light signal is then modulated by the LPFG and its intensity is acquired by a single photo-detector. Through curve-fitting algorithms the sensor transmission spectrum is reconstructed. Testing and validation were accomplished by inducing variations in the spectral features of an LPFG through changes either in external air temperature from 22 to 425 °C or in refractive index (RI) of the surrounding medium from 1.3000 to 1.4240. A dynamic resolution between 3.5 and 1.9 °C was achieved, in temperatures from 125 to 325 °C. In RI measurements, maximum wavelength and optical power deviations of 2.75 nm and 2.86 dB, respectively, were obtained in the range from 1530 to 1570 nm. The worse RI resolution obtained was 3.47 × 10 - 3 . The interrogation platform was then applied in the detection of iron corrosion, expressing wavelength peak values within 1.12 nm from the real value in the region between 1530 and 1570 nm.

3.
Sci Total Environ ; 627: 1505-1514, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-30857112

RESUMO

The growing economic interest in the exploitation of mineral resources on deep-ocean beds, including those in the vicinity of sensitive-rich habitats such as hydrothermal vents, raise a mounting concern about the damage that such actions might originate to these poorly-know ecosystems, which represent millions of years of evolution and adaptations to extreme environmental conditions. It has been suggested that mining may cause a major impact on vent ecosystems and other deep-sea areas. Yet, the scale and the nature of such impacts are unknown at present. Hence, building upon currently available scientific information it is crucial to develop new cost-effective technologies embedded into rigorous operating frameworks. The forward-thinking provided here will assist in the development of new technologies and tools to address the major challenges associated with deep sea-mining; technologies for in situ and ex situ observation and data acquisition, biogeochemical processes, hazard assessment of deep-sea mining to marine organisms and development of modeling tools in support of risk assessment scenarios. These technological developments are vital to validate a responsible and sustainable exploitation of the deep-sea mineral resources, based on the precautionary principle.

4.
Nanotechnology ; 27(18): 185501, 2016 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-27003717

RESUMO

A palladium (Pd)-based optical metamaterial has been designed, fabricated and characterized for its application in hydrogen sensing. The metamaterial can replace Pd thin films in optical transmission schemes for sensing with performances far superior to those of conventional sensors. This artificial material consists of a palladium-alumina metamaterial fabricated using inexpensive and industrial-friendly bottom-up techniques. During the exposure to hydrogen, the system exhibits anomalous optical absorption when compared to the well-known response of Pd thin films, this phenomenon being the key factor for the sensor sensitivity. The exposure to hydrogen produces a large variation in the light transmission through the metamembrane (more than 30% with 4% in volume hydrogen-nitrogen gas mixture at room temperature and atmospheric pressure), thus avoiding the need for sophisticated optical detection systems. An optical homogenization model is proposed to explain the metamaterial response. These results contribute to the development of reliable and low-cost hydrogen sensors with potential applications in the hydrogen economy and industrial processes to name a few, and also open the door to optically study the hydrogen diffusion processes in Pd nanostructures.

5.
Biosens Bioelectron ; 62: 227-33, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25016253

RESUMO

An evanescent wave fiber optic sensor for detection of Escherichia coli (E. coli) outer membranes proteins (EcOMPs) using long period gratings (LPGs) as a refractometric platform is presented. The sensing probes were attained by the functionalization of LPGs inscribed in single mode fiber using two different methods of immobilization; electrostatic assembly and covalent binding. The resulting label-free configuration enabled the specific recognition of EcOMPs in water by monitoring the resonance wavelength shift due to refractive index changes induced by binding events. The sensors displayed linear responses in the range of 0.1 nM to 10 nM EcOMPs with sensitivities of -0.1563±0.005 nm decade(-1) [EcOMP, M] (electrostatic method) and -0.1597±0.004 nm decade(-1) [EcOMP, M] (covalent method). The devices could be regenerated (under low pH conditions) with a deviation less than 0.1% for at least three subsequent detection events. The sensors were also applied to spiked environmental water samples.


Assuntos
Aptâmeros de Nucleotídeos , Proteínas da Membrana Bacteriana Externa/análise , Técnicas Biossensoriais/instrumentação , Proteínas de Escherichia coli/análise , Aptâmeros de Nucleotídeos/genética , Sequência de Bases , Técnicas Biossensoriais/métodos , Escherichia coli/genética , Tecnologia de Fibra Óptica , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Fibras Ópticas , Refratometria , Microbiologia da Água
6.
Rev Sci Instrum ; 84(1): 015002, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23387682

RESUMO

In this work the implementation of an optical fiber interferometric system for differential thermal analysis enabling the identification of chemical species is described. The system is based on a white light Mach-Zehnder configuration using pseudo-heterodyne demodulation to interrogate two identical fiber Bragg gratings (FBG) in a differential scheme. System performance is compared using either standard hardware or low cost virtual instrumentation for operation control and signal processing. The operation with the virtual system enabled temperature measurements with a ±0.023 °C resolution nearly matching the performance of the standard hardware. The system ability to discriminate chemical species by differential thermal analysis was demonstrated. Mixed samples of acetone and methanol could be successfully identified, indicating the suitability of the system for high precision measurements using low cost instrumentation.

7.
Anal Chim Acta ; 606(2): 223-9, 2008 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-18082654

RESUMO

A scheme for the simultaneous determination of oxygen and temperature using quantum dots and a ruthenium complex is demonstrated. The luminescent complex [Ru(II)-tris(4,7-diphenyl-1,10-phenanthroline)]2+ is immobilized in a non-hydrolytic sol-gel matrix and used as the oxygen sensor. The temperature information is provided by the luminescent emission of core-shell CdSe-ZnS semiconductor nanocrystals immobilized in the same material. Measurements of oxygen and temperature could be performed with associated errors of +/-2% of oxygen concentration and +/-1 degrees C, respectively. In addition, it is shown that while the dye luminescence intensity is quenched both by oxygen and temperature, the nanocrystals luminescent emission responds only to temperature. Results presented demonstrate that the combined luminescence response allows the simultaneous assessment of both parameters using a single optical fiber system. In particular, it was shown that a 10% error in the measured oxygen concentration, induced by a change in the sample temperature, could be compensated using the nanocrystals temperature information and a correction function.


Assuntos
Substâncias Luminescentes/química , Compostos Organometálicos/química , Oxigênio/análise , Fenantrolinas/química , Pontos Quânticos , Temperatura , Compostos de Cádmio/química , Calibragem , Estudos de Viabilidade , Medições Luminescentes , Nanopartículas/química , Tamanho da Partícula , Análise de Regressão , Reprodutibilidade dos Testes , Compostos de Selênio/química , Sulfetos/química , Compostos de Zinco/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA