Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 15: 1410871, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39011047

RESUMO

Background: Inflammatory scores are known to reflect the systemic inflammatory burden. Despite this, the association between the inflammatory score and the risk of all-cause and cardiovascular mortality in patients with metabolic syndrome (MetS) remains poorly understood. To address this gap in the literature, this study investigated this potential association between these two factors. Methods: A total of 3401 patients with MetS from the National Health and Nutrition Examination Survey (1999-2010) were enrolled. Survival status and cause of death were obtained by linking data from the National Death Index (NDI). The inflammatory score was calculated based on the sum of the Z-scores for white blood cell (WBC) count and C-reactive protein (CRP) at baseline. The patients were divided into inflammatory score quartiles. Cox proportional hazards regression was used to determine the association between inflammatory score and mortality. Restricted cubic splines (RCS) were used to explore the dose-response relationship between inflammatory score and mortality. Stratified analyses and interaction tests were conducted according to sex, age, body mass index (BMI), alcohol consumption, smoking status, hypertension, diabetes, and stroke status. Results: After a mean follow-up of 145.9 months, 1039 all-cause deaths and 295 cardiovascular deaths were recorded. The results of multivariate Cox regression analysis showed that compared to the lowest quartile (Q1), patients in the highest quartile (Q4) had a 1.74-fold increased risk of all-cause mortality (Model 3: HR = 1.74, 95%CI 1.30-2.32, P < 0.001) and a 1.87-fold increased risk of cardiovascular mortality (Model 3: HR = 1.87, 95%CI 1.12-3.13, P = 0.020). There was a 'J'-shaped nonlinear relationship between the inflammatory score and all-cause mortality (P for nonlinearity = 0.001), and a marginally significant 'J'-shaped relationship with cardiovascular mortality (P for nonlinearity = 0.057). The threshold points of the inflammatory score for adverse outcomes were - 0.643 and - 0.621, respectively. Conclusion: The inflammatory score is independently associated with increased all-cause and cardiovascular mortality in patients with MetS, and risk stratification of these patients using inflammatory scores may provide specific therapeutic strategies to improve their prognosis.


Assuntos
Doenças Cardiovasculares , Inflamação , Síndrome Metabólica , Inquéritos Nutricionais , Humanos , Síndrome Metabólica/mortalidade , Síndrome Metabólica/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/etiologia , Inflamação/mortalidade , Estudos Longitudinais , Idoso , Adulto , Causas de Morte , Proteína C-Reativa/análise , Fatores de Risco , Biomarcadores/sangue , Contagem de Leucócitos , Estados Unidos/epidemiologia
2.
Front Endocrinol (Lausanne) ; 15: 1405828, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38808115

RESUMO

Background: Atherogenic Index of plasma (AIP) is closely related to metabolic abnormalities. But as of now, there is no definitive conclusion on the dose-response relationship pattern between AIP and metabolic associated fatty liver disease (MAFLD). Objective: The objective of this study was to provide a fresh insight for understanding the intrinsic link between AIP and the prevalence of MAFLD by exploring the dose-response pattern between AIP and MAFLD. Methods: A total of 9254 participants received the survey and 1090 participants were finally included according to the screening criteria. To evaluate the association between AIP and the prevalence of MAFLD based on weighted multivariate logistic regression. Sensitivity analysis of the association between AIP and MAFLD was performed using propensity score matching (PSM). Restrictive cubic splines (RCS) were used to identify patterns of dose-response relationships between AIP and MAFLD, and receiver operator characteristic (ROC) curves were used to evaluate the predictive ability of AIP and traditional lipid parameters for MAFLD. Results: In this study, a total of 563 participants were found to have MAFLD. The results of weighted multivariate logistic regression analysis demonstrated that, after adjusting for sex and age, participants in the highest quartile (Q4) of AIP had a significantly increased risk of developing MAFLD compared to those in the lowest quartile (Q1) (Model 2: OR = 9.03, 95% CI 4.75-17.17). A similar trend was observed in the fully adjusted model (Model 3: OR = 3.85, 95% CI 1.55-9.52). The RCS analysis revealed a linear dose-response association between AIP and MAFLD(P for crude non-linearity = 0.087). This association remained significant after accounting for potential confounding variables(P for adjusted non-linearity = 0.663). The ROC curve results suggest that AIP performs better than traditional lipid indicators in predicting MAFLD (AUC = 0.732, 95%CI 0.705-0.758). Conclusion: A linear dose-response relationship exists between AIP and MAFLD, suggesting that as AIP increases, so does the risk of developing MAFLD.


Assuntos
Inquéritos Nutricionais , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Prevalência , Adulto , Estados Unidos/epidemiologia , Fígado Gorduroso/epidemiologia , Fígado Gorduroso/sangue , Idoso , Aterosclerose/epidemiologia , Aterosclerose/sangue , Fatores de Risco
3.
Luminescence ; 39(5): e4754, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38679894

RESUMO

Near-infrared mechanoluminescence is a phenomenon that produces high penetrating near-infrared light under external stimulation. Near-infrared light coincides with the biological window, lower optical loss, and the fact that the mechanoluminescence material is a medium that converts mechanical energy into light energy. The near-infrared mechanoluminescence material has potential application prospects in the fields of biological imaging, medical diagnosis, and monitoring of building materials. In this article, we report on a perovskite-type Sr3Sn2O7:Nd3+ near-infrared mechanoluminescence material, and its peaks locate in the first near-infrared window (800-1000 nm) and the second near-infrared window (1080, 1350 nm), respectively. Under the condition of pre-sintering with Li2CO3 as flux, the best sintering conditions are obtained, and the luminescence of material is in perfect agreement with the applied mechanical stress. In addition, a near-infrared mechanoluminescence sensor is proposed to solve the problem of building damage and timely maintenance.


Assuntos
Raios Infravermelhos , Medições Luminescentes , Titânio , Luminescência , Óxidos/química , Estrôncio/química , Neodímio/química , Compostos de Cálcio/química
4.
Adv Mater ; 36(26): e2401296, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38599208

RESUMO

Elastico-mechanoluminescence technology has shown significant application prospects in stress sensing, artificial skin, remote interaction, and other research areas. Its progress mainly lies in realizing stress visualization and 2D or even 3D stress-sensing effects using a passive sensing mode. However, the widespread promotion of mechanoluminescence (ML) technology is hindered by issues such as high stress or strain thresholds and a single sensing mode based on luminous intensity. In this study, a highly efficient green-emitting ML with dual-mode stress-sensing characteristics driven by microscale strain is developed using LiTaO3:Tb3+. In addition to single-mode sensing based on the luminous intensity, the self-defined parameter (Q) is also introduced as a dual-mode factor for sensing the stress velocity. Impressively, the fabricated LiTaO3:Tb3+ film is capable of generating discernible ML signals even when supplied with strains as low as 500 µst. This is the current minimum strain value that can drive green-emitting ML. This study offers an ideal photonic platform for exploring the potential applications of rare-earth-doped elastico-ML materials in remote interaction devices, high-precision stress sensors, and single-molecule biological imaging.

5.
Sensors (Basel) ; 23(22)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38005553

RESUMO

A sandwiched piezoelectric accelerometer is developed and optimized for acquiring low-frequency, wide-band seismic data. The proposed accelerometer addresses the challenges of capturing seismic signals in the low-frequency range while maintaining a broad frequency response through the design of multi-stage charge amplifiers and a sandwiched structure. The device's design, fabrication process, and performance evaluation are discussed in detail. Experimental results demonstrate its performance in amplitude and phase response characteristics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA