Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Arab J Gastroenterol ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38403494

RESUMO

BACKGROUND AND STUDY AIMS: Periampullary diverticula (PAD), a location-specific type of duodenal diverticula, can cause serious complications. PAD is difficult to differentially diagnose, mainly due to its nonspecific symptoms. This study aimed to identify sonographic features of PAD and to evaluate their value in the differential diagnosis of PAD from stones in the lower common bile duct (CBD). PATIENTS AND METHODS: A total of 30 patients with PAD and 60 patients with lower CBD stones were retrospectively enrolled, and sonographic features were analyzed. Measurements of sonographic features included echo shaped, posterior echo changes, location and relation to surrounding organs, and status of intrahepatic and extrahepatic bile duct dilation, and their diagnostic performance was assessed. RESULTS: Characteristic sonographic features of PAD were identified, including strong echoes (28/30, 93.3 %), strip shape (28/30, 93.3 %), multiple reflections in the posterior echo (27/30, 90.0 %), and location outside the CBD or near the biliary wall in connection with the duodenum (27/30, 90.0 %). Inter-observer agreement was good (Kappa values = 0.69-0.82). Comparative analysis of sonographic features revealed significant differences in echo shape, posterior echo changes (multiple reflections and acoustic shadowing), location and relation to surrounding organs, and intrahepatic and extrahepatic bile duct dilatation status between the dilatation status of the two groups. In particular, these characteristics achieved a sensitivity of 100 % and a specificity of 98 % for the differential diagnosis of PAD and lower CBD stones. CONCLUSIONS: This study identified characteristic sonographic features of PAD, which could be used as potential diagnostic indicators to distinguish PAD from lower CBD stones.

2.
Brief Bioinform ; 24(1)2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36575566

RESUMO

Recent developments of deep learning methods have demonstrated their feasibility in liver malignancy diagnosis using ultrasound (US) images. However, most of these methods require manual selection and annotation of US images by radiologists, which limit their practical application. On the other hand, US videos provide more comprehensive morphological information about liver masses and their relationships with surrounding structures than US images, potentially leading to a more accurate diagnosis. Here, we developed a fully automated artificial intelligence (AI) pipeline to imitate the workflow of radiologists for detecting liver masses and diagnosing liver malignancy. In this pipeline, we designed an automated mass-guided strategy that used segmentation information to direct diagnostic models to focus on liver masses, thus increasing diagnostic accuracy. The diagnostic models based on US videos utilized bi-directional convolutional long short-term memory modules with an attention-boosted module to learn and fuse spatiotemporal information from consecutive video frames. Using a large-scale dataset of 50 063 US images and video frames from 11 468 patients, we developed and tested the AI pipeline and investigated its applications. A dataset of annotated US images is available at https://doi.org/10.5281/zenodo.7272660.


Assuntos
Inteligência Artificial , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Fluxo de Trabalho
3.
J Ultrasound Med ; 42(1): 7-15, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35441714

RESUMO

This study aimed to evaluate the diagnostic value of HyCoSy using sulfur hexafluoride microbubbles for fallopian tubal patency assessment in infertile females. Twenty-four studies, including 1358 females with 2661 detected fallopian tubes published from January 2003 to May 2019, were identified. The pooled sensitivity was 93% (95% CI: 90-95%), while the specificity was 90% (95% CI: 87-92%). The area under the receiver-operating characteristic curve was 0.96 (95% CI: 94-98%). The specificity of the four-dimensional HyCoSy subgroup was higher than the 2D/3D subgroup; an increased dose of contrast agent did not affect the specificity, with only a slightly reduced sensitivity.


Assuntos
Tubas Uterinas , Infertilidade Feminina , Feminino , Humanos , Tubas Uterinas/diagnóstico por imagem , Hexafluoreto de Enxofre , Histerossalpingografia/métodos , Testes de Obstrução das Tubas Uterinas/métodos , Microbolhas , Meios de Contraste , Ultrassonografia/métodos
4.
J Ultrasound Med ; 40(9): 1927-1934, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33270273

RESUMO

OBJECTIVES: Biliary perfusion is considered to contribute to biliary diseases, but routine imaging methods are insufficient to show it. This research investigated the ability of contrast-enhanced ultrasound (CEUS) for biliary perfusion in a biliary ischemia model. METHODS: This research consisted of 2 parts. First, to determine whether CEUS enhancement of the tiny biliary wall represents biliary perfusion, a vascular tracer was used as a reference to evaluate the consistency with the enhancement of the biliary wall on CEUS and the staining by the vascular tracer under the conditions of occluded and recovered biliary perfusion. In the second part, the ability of CEUS for biliary ischemia was further evaluated with microvascular density measurement as a reference. The enhancement patterns were assigned CEUS scores, in which higher scores meant more decreased enhancement, and the diagnostic ability of CEUS was assessed by a receiver operating characteristic curve analysis. RESULTS: The biliary wall was unstained by the vascular tracer and nonenhanced on CEUS when biliary perfusion was interrupted and was stained blue and enhanced after recovery. The biliary wall in the ischemia surgery group showed lower microvascular density measurements (P < .001), decreased enhancement levels (P < .001), and higher CEUS scores (P < .001). When a CEUS score of 3 or higher (obvious decrease of the biliary wall to hypoenhancement or nonenhancement in the arterial phase or rapid wash-out to nonenhancement in the portal venous phase) was applied, CEUS had sensitivity of 87.8%, specificity of 98.3%, accuracy of 93.8%, and an area under the receiver operating characteristic curve of 0.98. CONCLUSIONS: Contrast enhancement of the biliary wall on CEUS represents biliary perfusion and has reasonably good diagnostic performance for biliary ischemia in an experimental animal setting.


Assuntos
Meios de Contraste , Isquemia , Animais , Humanos , Isquemia/diagnóstico por imagem , Curva ROC , Ultrassonografia
5.
Ultrasound Med Biol ; 47(3): 446-453, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33353786

RESUMO

Hepatic angiomyolipoma (HAML) comprises epithelioid angiomyolipoma (EAML) and classic hepatic angiomyolipoma (CAML). The imaging appearance of HAML varies widely, and EAML is more easily misdiagnosed as hepatocellular carcinoma (HCC) than as CAML. The clinical and contrast-enhanced ultrasound (CEUS) features of CAML, EAML and HCC with negative alpha-fetoprotein protein expression (HCC[AFP-]) were retrospectively reviewed. The hyper-vascular type was more commonly found in CAML and EAML lesions than in HCC lesions. Most lesions were hyper-enhanced in the arterial phase. CAMLs showed prolonged hyper-enhancement or iso-enhancement during the portal and late phases on CEUS, making them easily distinguishable from HCC(AFP-). Some EAML lesions (41.7%) were hypo-echoic, similar to HCC(AFP-). However, the hypo-enhancement of EAML lesions occurred later than that of HCC(AFP-) lesions. Thus, our findings may be useful in distinguishing among these lesions to improve diagnostic accuracy.


Assuntos
Angiomiolipoma/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Angiomiolipoma/diagnóstico , Angiomiolipoma/patologia , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , alfa-Fetoproteínas/metabolismo
6.
Am J Cancer Res ; 10(7): 2174-2184, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32775009

RESUMO

In certain difficult cases involving tumors unclear in B-mode ultrasound or tumors in a high-risk location, image-guided liver tumor thermal ablation was previously contraindicated. The aim of this retrospective study was to investigate the value of intra-procedural ultrasound fusion imaging in improving the therapeutic effect and safety of liver tumor ablation in difficult cases. A total of 502 patients (441 males and 61 females, aged 52 ± 11 years) with 805 liver tumors (16 ± 6 mm; range, 4-29 mm) who underwent thermal ablation with intra-procedural fusion imaging from October 2010 to June 2018 in our hospital were enrolled. Fusion imaging was employed for targeting, puncture guidance and immediate evaluation of the therapeutic response. Contrast-enhanced computed tomography (CT)/magnetic resonance imaging (MRI) was performed one month after ablation and every 3~6 months in the follow-up period. 511 and 294 liver tumors were in classified in the difficult case group and the non-difficult case group, respectively. The technical efficacy rate was 99.4% (800/805), and no difference was found between the two groups (P=0.658). No significant difference in the local tumor progression rate was found between the difficult case group (1 year: 3.2%; 3 years: 7.6%; 5 years: 7.6%) and non-difficult case group (1 year: 2.1%; 3 years: 5.5%; 5 years: 11.6%) (P=0.874). The major complication rate was 1.8% (11/608). Injury to adjacent organs occurred in only 1 patient who sustained a bile duct injury. We conclude that intra-procedural fusion imaging can improve the therapeutic efficacy and safety of thermal ablation in difficult cases and may expand the indications for thermal ablation.

7.
Int J Hyperthermia ; 36(1): 785-793, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31431086

RESUMO

Purpose: To evaluate whether local tumor progression (LTP) would be further reduced when contrast-enhanced ultrasound (CEUS)-CT/MR fusion imaging was used as intraprocedural assessment method in hepatocellular carcinoma (HCC) thermal ablation compared with routine CEUS. Materials and methods: This prospective non-randomized study was conducted from December 2010 to July 2012. CEUS-CT/MR fusion imaging and routine CEUS were used for treatment response assessment in the ablation procedure of 146 HCCs and 122 HCCs, respectively. Supplementary ablations were performed immediately if necessary. The primary technique efficacy rate, LTP rate and overall survival (OS) rate were calculated. Results: For CEUS-CT/MR fusion imaging and routine CEUS, the technical success rate, technique efficacy rate and supplementary ablation rate were 86.3% (126/146) and 98.4% (120/122) (p = .000), 99.2% (125/126) and 94.2% (113/120) (p = .032), and 14.3% (18/126) and 4.2% (5/120) (p = .006), respectively. The cumulative LTP rate and OS rate were not significantly different between fusion imaging group and routine CEUS group. However, for lesions that were larger than 3 cm or close to major vessels (41 lesions in fusion imaging group and 44 lesions in routine CEUS group, who received transcatheter arterial chemoembolization before ablation), the cumulative LTP rate was significantly lower in fusion imaging group than in routine CEUS group (p = .032). Conclusion: Although intraprocedural CEUS-CT/MR fusion imaging has certain limitations in application, it might provide a potential more efficient method compared with routine CEUS in reducing LTP in HCC thermal ablation, especially for difficult ablation lesions.


Assuntos
Técnicas de Ablação , Carcinoma Hepatocelular/cirurgia , Meios de Contraste/uso terapêutico , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Progressão da Doença , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
8.
Endocrine ; 62(2): 307-317, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30073455

RESUMO

PURPOSE: To evaluate the effectiveness and safety of microwave ablation (MWA), including cooled MWA (cMWA) and uncooled MWA (uMWA), for the treatment of benign thyroid nodules (BTNs). METHODS: The databases of MEDLINE, EMBASE and Cochrane library were searched up to 3 Jun, 2018. In this meta-analysis, data of volume reduction rates (VRRs) at the 3-, 6- and 12-month follow-up, and complications are obtained to evaluate the effectiveness and safety of cMWA and uMWA for the treatment of BTNs. RESULTS: Nine studies involving 1461 patients with 1845 BTNs were included. The pooled VRR at the 3-month follow-up after MWA therapy reached 54.3% (95% CI: 45.3-63.3%, I2 = 97.6%), 73.5% (95% CI: 66.7-80.3%, I2 = 94.9%) at the 6-month follow-up, and 88.6% (95% CI: 84.9-92.4%, I2 = 92.7%) at the 12-month follow-up. The pooled proportions of overall, major and minor complications were 52.4% (95% CI: 29.8-74.9%; I2 = 99.5%), 4.8% (95% CI: 2.7-7.0%; I2 = 55.9%) and 48.3% (95% CI: 31.2-65.4%; I2 = 99.7%). Both cMWA and uMWA achieved similar pooled VRR at the 3-month follow-up (58.4 vs 45.3%, P = 0.07) and pooled proportion of major complications (4.9 vs 5.0%, P = 0.49), while uMWA had higher pooled proportions of overall and minor complications than cMWA (97.8 vs 29.7%, P < 0.01; 97.8 vs 21.0%, P < 0.01), with more patients suffering pain and skin burn after uMWA (100 vs 5.5%, P < 0.01; 47.2 vs 0.2%, P < 0.01). CONCLUSION: MWA is an effective treatment modality for BTNs. When considering the patient's comfort, cMWA would be a more preferable procedure with less complications.


Assuntos
Hipotermia Induzida/métodos , Micro-Ondas/uso terapêutico , Ablação por Radiofrequência/métodos , Nódulo da Glândula Tireoide/terapia , Terapia Combinada , Humanos , Hipotermia Induzida/efeitos adversos , Hipotermia Induzida/estatística & dados numéricos , Micro-Ondas/efeitos adversos , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/estatística & dados numéricos , Nódulo da Glândula Tireoide/epidemiologia , Resultado do Tratamento
9.
Eur J Radiol ; 85(11): 1993-2000, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27776651

RESUMO

PURPOSE: To investigate the value of double contrast-enhanced ultrasonography (DCEUS) in the detection of periampullary cancer. MATERIALS AND METHODS: Ninety-nine patients with surgery or biopsy-proven periampullary cancer who underwent both DCEUS and magnetic resonance imaging (MRI) examinations before operation were enrolled in our study. DCEUS in which intravenous microbubbles were used in combination with oral contrast agent and MRI were performed preoperatively to make a detection diagnosis of periampullary cancer. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DCEUS, B-mode ultrasonography (BUS) and MRI were calculated and compared. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of BUS, DCEUS and MRI in the detection. Stratified analyses were performed for different pathological types and different sizes of periampullary lesions. The inter- and intra-observer reliability of DCEUS for cancer detection was also investigated. RESULT: There were no significant differences in sensitivity, specificity, PPV, NPV or accuracy between DCEUS and MRI (all P>0.05). ROC analysis showed that the accuracy of DCEUS or MRI was higher than that of BUS (P<0.001), while no significant differences were noted in the accuracy between DCEUS and MR. In the 76 cases of periampullary cancer, DCEUS appeared to be superior to BUS for ampullary carcinoma, duodenum carcinoma and for lesions with an average diameter of less than 3cm. DCEUS appeared equal to BUS in other groups. No significant differences were noted between DCEUS and MRI in the stratified analysis. A considerably well agreement between DCEUS and MRI was obtained using Kappa analysis (k=0.649, P<0.001). The intra- and inter-observer reproducibility were both good for detection of periampullary cancer by DCEUS, with a Kappa values of 0.783 (P<0.01) and 0.732 (P<0.01), respectively. CONCLUSION: DCEUS provides an available and useful imaging modality in the detection of periampullary cancer. This technique can aid in displaying the invisible periampullary region in BUS and may also become an effective supplemental method to MRI.


Assuntos
Neoplasias do Ducto Colédoco/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ampola Hepatopancreática/diagnóstico por imagem , Ampola Hepatopancreática/patologia , Ducto Colédoco/diagnóstico por imagem , Ducto Colédoco/patologia , Feminino , Humanos , Masculino , Microbolhas , Pessoa de Meia-Idade , Fosfolipídeos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Hexafluoreto de Enxofre , Adulto Jovem
10.
BMC Cancer ; 16: 277, 2016 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-27090513

RESUMO

BACKGROUND: To assess whether intraoperative use of contrast-enhanced ultrasound (CEUS)-CT/MR image fusion can accurately evaluate ablative margin (AM) and guide supplementary ablation to improve AM after hepatocellular carcinoma (HCC) ablation. METHODS: Ninety-eight patients with 126 HCCs designated to undergo thermal ablation treatment were enrolled in this prospective study. CEUS-CT/MR image fusion was performed intraoperatively to evaluate whether 5-mm AM was covered by the ablative area. If possible, supplementary ablation was applied at the site of inadequate AM. The CEUS image quality, the time used for CEUS-CT/MR image fusion and the success rate of image fusion were recorded. Local tumor progression (LTP) was observed during follow-up. Clinical factors including AM were examined to identify risk factors for LTP. RESULTS: The success rate of image fusion was 96.2% (126/131), and the duration required for image fusion was 4.9 ± 2.0 (3-13) min. The CEUS image quality was good in 36.1% (53/147) and medium in 63.9% (94/147) of the cases. By supplementary ablation, 21.8% (12/55) of lesions with inadequate AMs became adequate AMs. During follow-up, there were 5 LTPs in lesions with inadequate AMs and 1 LTP in lesions with adequate AMs. Multivariate analysis showed that AM was the only independent risk factor for LTP (hazard ratio, 9.167; 95% confidence interval, 1.070-78.571; p = 0.043). CONCLUSION: CEUS-CT/MR image fusion is feasible for intraoperative use and can serve as an accurate method to evaluate AMs and guide supplementary ablation to lower inadequate AMs.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Feminino , Humanos , Imageamento Tridimensional , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA