1.
Biosensors (Basel) ; 11(12)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34940248

RESUMO

For most of the fast screening test papers for detecting Hg2+, the obtained results are qualitative. This study developed an operation for the µPAD and combined it with the chemical colorimetric method. Silver nanoparticle (AgNP) colloids were adopted as the reactive color reagent to combine and react with the Hg standards on the paper-based chip. Then, the RGB values for the color change were used to establish the standard curve (R2 > 0.99). Subsequently, this detection system was employed for the detection tests of actual samples, and the detected RGB values of the samples were substituted back to the formula to calculate the Hg2+ contents in the food. In this study, the Hg2+ content and recovery rate in commercially available packaged water and edible salts were measured. The research results indicate that a swift, economical, and simple detection method for Hg2+ content in food has been successfully developed.


Assuntos
Mercúrio , Nanopartículas Metálicas , Colorimetria , Microfluídica , Prata/análise , Prata/química
2.
Micromachines (Basel) ; 12(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34577766

RESUMO

Silver nanoparticles (AgNPs) have stable reactivity and excellent optical absorption properties. They can be applied in various industries, such as environmental protection, biochemical engineering, and analyte monitoring. However, synthesizing AgNPs and determining their appropriate dosage as a coloring substance are difficult tasks. In this study, to optimize the process of AgNP synthesis and obtain a simple detection method for trace mercury in the environment, we evaluate several factors-including the reagent addition sequence, reaction temperature, reaction time, the pH of the solution, and reagent concentration-considering the color intensity and purity of AgNPs as the reaction optimization criteria. The optimal process for AgNP synthesis is as follows: Mix 10 mM of silver nitrate with trisodium citrate in a hot water bath for 10 min; then, add 10 mM of sodium borohydride to produce the AgNPs and keep stirring for 2 h; finally, adjust the pH to 12 to obtain the most stable products. For AgNP-based mercury detection, the calibration curve of mercury over the concentration range of 0.1-2 ppb exhibits good linearity (R2 > 0.99). This study provides a stable and excellent AgNP synthesis technique that can improve various applications involving AgNP-mediated reactions and has the potential to be developed as an alternative to using expensive detection equipment and to be applied for the detection of mercury in food.

3.
Anal Chim Acta ; 1071: 44-52, 2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31128754

RESUMO

A multifunctional microchip-based distillation apparatus is presented for the distilled of sulfur dioxide (SO2) in food products. The microchip is fabricated on poly(methyl methacrylate) (PMMA) substrates, and comprises a sample zone, a buffer zone, a serpentine distillation column, and a collection zone. In the process, the sample is introduced into the sample zone and is heated under carefully controlled temperature and time conditions. The resulting SO2 and water vapor are carried by nitrogen (N2) gas to the distillation column, where the SO2 is separated from the water vapor via the condensing effects of a continuous cold water flow. Finally, the SO2 is transported to the collection zone, where it is collected with hydrogen peroxide (H2O2) and its concentration determined using an alkali-based titration and paper-based detection method. A distillation efficiency of 90.5% is obtained under the optimal distillation conditions at concentrations of 20-4000 ppm. Moreover, a linear correlation (R2 = 0.9997) is observed between the experimental measurements of the SO2 concentration and the known concentration. The validity of the presented microchip-based distillation apparatus is further investigated by distilling the SO2 concentrations of 25 commodity samples. The detection results show that the deviation does not exceed 5.4% compared with the traditional official method.


Assuntos
Destilação/métodos , Técnicas Analíticas Microfluídicas/métodos , Dióxido de Enxofre/análise , Destilação/instrumentação , Contaminação de Alimentos/análise , Frutas/química , Dispositivos Lab-On-A-Chip , Limite de Detecção , Técnicas Analíticas Microfluídicas/instrumentação , Polimetil Metacrilato/química , Verduras/química
4.
Anal Chim Acta ; 912: 97-104, 2016 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-26920777

RESUMO

An integrated microfluidic distillation system is proposed for separating a mixed ethanol-methanol-water solution into its constituent components. The microfluidic chip is fabricated using a CO2 laser system and comprises a serpentine channel, a boiling zone, a heating zone, and a cooled collection chamber filled with de-ionized (DI) water. In the proposed device, the ethanol-methanol-water solution is injected into the microfluidic chip and driven through the serpentine channel and into the collection chamber by means of a nitrogen carrier gas. Following the distillation process, the ethanol-methanol vapor flows into the collection chamber and condenses into the DI water. The resulting solution is removed from the collection tank and reacted with a mixed indicator. Finally, the methanol concentration is inversely derived from the absorbance measurements obtained using a spectrophotometer. The experimental results show the proposed microfluidic system achieves an average methanol distillation efficiency of 97%. The practicality of the proposed device is demonstrated by detecting the methanol concentrations of two commercial fruit wines. It is shown that the measured concentration values deviate by no more than 3% from those obtained using a conventional bench top system.


Assuntos
Dispositivos Lab-On-A-Chip , Metanol/análise , Limite de Detecção
5.
Biomicrofluidics ; 6(3): 34111, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23940501

RESUMO

A rapid and simple technique is proposed for methanol concentration detection using a PMMA (Polymethyl-Methacrylate) microfluidic chip patterned using a commercially available CO2 laser scriber. In the proposed device, methanol and methanol oxidase (MOX) are injected into a three-dimensional circular chamber and are mixed via a vortex stirring effect. The mixture is heated to prompt the formation of formaldehyde and is flowed into a rectangular chamber, to which fuchsin-sulphurous acid is then added. Finally, the microchip is transferred to a UV spectrophotometer for methanol detection purposes. The experimental results show that a correlation coefficient of R(2) = 0.9940 is obtained when plotting the optical density against the methanol concentration for samples and an accuracy as high as 93.1% are compared with the determined by the high quality gas chromatography with concentrations in the range of 2 ∼ 100 ppm. The methanol concentrations of four commercial red wines are successfully detected using the developed device. Overall, the results show that the proposed device provides a rapid and accurate means of detecting the methanol concentration for a variety of applications in the alcoholic beverage inspection and control field.

6.
Lab Chip ; 12(3): 622-6, 2012 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-22159042

RESUMO

A miniaturized distillation system is presented for separating sulfurous acid (H(2)SO(3)) into sulfur dioxide (SO(2)) and water (H(2)O). The major components of the proposed system include a microfluidic distillation chip, a power control module, and a carrier gas pressure control module. The microfluidic chip is patterned using a commercial CO(2) laser and comprises a serpentine channel, a heating zone, a buffer zone, a cooling zone, and a collection tank. In the proposed device, the H(2)SO(3) solution is injected into the microfluidic chip and is separated into SO(2) and H(2)O via an appropriate control of the distillation time and temperature. The gaseous SO(2) is then transported into the collection chamber by the carrier gas and is mixed with DI water. Finally, the SO(2) concentration is deduced from the absorbance measurements obtained using a spectrophotometer. The experimental results show that a correlation coefficient of R(2) = 0.9981 and a distillation efficiency as high as 94.6% are obtained for H(2)SO(3) solutions with SO(2) concentrations in the range of 100-500 ppm. The SO(2) concentrations of two commercial red wines are successfully detected using the developed device. Overall, the results presented in this study show that the proposed system provides a compact and reliable tool for SO(2) concentration measurement purposes.


Assuntos
Destilação/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentação , Dióxido de Enxofre/isolamento & purificação , Calibragem , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Lasers , Reprodutibilidade dos Testes , Espectrofotometria , Vinho/análise