Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39395076

RESUMO

PURPOSE: To compare the application of two contrast-enhanced time-resolved magnetic resonance angiography sequences on an aortic disease patient cohort: the conventional Cartesian-sampling-based, Time-resolved angiography With Interleaved Stochastic Trajectories (TWIST) sequence, and the radial-sampling-based Golden-angle RAdial Sparse Parallel (GRASP) sequence. TWIST is highly sensitive to patient movement, which can lead to blurring and reduced sharpness of vascular structures, particularly in dynamic regions like the aorta. Such motion artifacts can compromise diagnostic accuracy. Radial-sampling-based techniques are less sensitive to motion than cartesian sampling and are expected to improve the image quality in body parts subjected to motion. METHODS: 30 patients (60.9 ± 16.1y.o.) with various aortic diseases underwent a 1.5T magnetic resonance angiography examination. Assessment of image quality in the ascending aorta (AA), descending aorta (DA), and abdominal aorta (AbA) on a 4-point Likert scale (1 = excellent, 4 = non-diagnostic) as well as max. aortic diameters (Dmax) were performed. T-test and multilevel mixed-effect proportional-odds models were used for the image analysis. RESULTS: GRASP offered superior depiction of vascular structures in terms of vascular contrast for qualitative analysis (TWIST, reader 1: 1.6 ± 0.5; reader 2: 1.9 ± 0.4; reader 3: 1.1 ± 0.4; GRASP, reader 1: 1.5 ± 0.5; reader 2: 1.4 ± 0.5; reader 3: 1.0 ± 0.2) and vessel sharpness for qualitative (TWIST, reader 1: 1.9 ± 0.6; reader 2: 1.6 ± 0.6; reader 3: 2.0 ± 0.3; GRASP, reader 1: 1.4 ± 0.6; reader 2: 1.2 ± 0.4; reader 3: 1.3 ± 0.6) and quantitative analysis (TWIST, AA = 0.12 ± 0.04, DA = 0.12 ± 0.03, AbA = 0.11 ± 0.03; GRASP, AA = 0.20 ± 0.05, DA = 0.22 ± 0.06, AbA=0.20 ± 0.05). Streaking artefacts of GRASP were more visible compared to TWIST (TWIST, reader 1: 2.2 ± 0.6; reader 2: 1.9 ± 0.3; reader 3: 2.0 ± 0.5; GRASP, reader 1: 2.6 ± 0.6; reader 2: 2.3 ± 0.5; reader 3: 2.8 ± 0.6). Aortic Dmax comparison among the sequence showed no clinical relevance. CONCLUSION: GRASP outperformed TWIST in SNR, vessel sharpness, and reduction in image blurring; streaking artefacts were stronger with GRASP, but did not affect diagnostic image quality.

3.
Front Cardiovasc Med ; 11: 1411752, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39145279

RESUMO

Introduction: 4D flow cardiovascular magnetic resonance (CMR) is a versatile technique to non-invasively assess cardiovascular hemodynamics. With developing technology, choice in sequences and acquisition parameters is expanding and it is important to assess if data acquired with these different variants can be directly compared, especially when combining datasets within research studies. For example, sequences may allow a choice in gating techniques or be limited to one method, yet there is not a direct comparison investigating how gating selection impacts quantifications of the great vessels, semilunar and atrioventricular valves and ventricles. Thus, this study investigated if quantifications across the heart from contemporary 4D flow sequences are comparable between two commonly used 4D flow sequences reliant on different ECG gating techniques. Methods: Forty participants (33 healthy controls, seven patients with coronary artery disease and abnormal diastolic function) were prospectively recruited into a single-centre observational study to undergo a 3T-CMR exam. Two acquisitions, a k-t GRAPPA 4D flow with prospective gating (4Dprosp) and a modern compressed sensing 4D flow with retrospective gating (4Dretro), were acquired in each participant. Images were analyzed for volumes, flow rates and velocities in the vessels and four valves, and for biventricular kinetic energy and flow components. Data was compared for group differences with paired t-tests and for agreement with Bland-Altman and intraclass correlation (ICC). Results: Measurements primarily occurring during systole of the great vessels, semilunar valves and both left and right ventricles did not differ between acquisition types (p > 0.05 from t-test) and yielded good to excellent agreement (ICC: 0.75-0.99). Similar findings were observed for the majority of parameters dependent on early diastole. However, measurements occurring in late diastole or those reliant on the entire-cardiac cycle such as flow component volumes along with diastolic kinetic energy values were not similar between 4Dprosp and 4Dretro acquisitions resulting in poor agreement (ICC < 0.50). Discussion: Direct comparison of measurements between two different 4D flow acquisitions reliant on different gating methods demonstrated systolic and early diastolic markers across the heart should be compatible when comparing these two 4D flow sequences. On the other hand, late diastolic and intraventricular parameters should be compared with caution.

4.
Top Magn Reson Imaging ; 33(4): e0313, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39016321

RESUMO

OBJECTIVES: The radiological imaging industry is developing and starting to offer a range of novel artificial intelligence software solutions for clinical radiology. Deep learning reconstruction of magnetic resonance imaging data seems to allow for the acceleration and undersampling of imaging data. Resulting reduced acquisition times would lead to greater machine utility and to greater cost-efficiency of machine operations. MATERIALS AND METHODS: Our case shows images from magnetic resonance arthrography under traction of the right hip joint from a 30-year-old, otherwise healthy, male patient. RESULTS: The undersampled image data when reconstructed by a deep learning tool can contain false-positive cartilage delamination and false-positive diffuse cartilage defects. CONCLUSIONS: In the future, precision of this novel technology will have to be put to thorough testing. Bias of systems, in particular created by the choice of training data, will have to be part of those assessments.


Assuntos
Artrografia , Aprendizado Profundo , Articulação do Quadril , Imageamento por Ressonância Magnética , Humanos , Masculino , Imageamento por Ressonância Magnética/métodos , Adulto , Artrografia/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Processamento de Imagem Assistida por Computador/métodos , Tração , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Reações Falso-Positivas , Interpretação de Imagem Assistida por Computador/métodos
5.
Eur J Anaesthesiol ; 41(7): 480-489, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38323332

RESUMO

BACKGROUND: Induction of general anaesthesia has many potential triggers for peri-operative myocardial ischaemia including the acute disturbance of blood gases that frequently follows alterations in breathing and ventilation patterns. Free-breathing oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging may provide the opportunity to continuously quantify the impact of such triggers on myocardial oxygenation. OBJECTIVE: To investigate the impact of breathing patterns that simulate induction of general anaesthesia on myocardial oxygenation in awake healthy adults using continuous OS-CMR imaging. DESIGN: Prospective observational study. SETTING: Single-centre university hospital. Recruitment from August 2020 to January 2022. PARTICIPANTS: Thirty-two healthy volunteers younger than 45 years old were recruited. Data were analysed from n  = 29 (69% male individuals). INTERVENTION: Participants performed a simulated induction breathing manoeuvre consisting of 2.5 min paced breathing with a respiration rate of 14 breaths per minute, followed by 5 deep breaths, then apnoea for up to 60s inside a magnetic resonance imaging scanner (MRI). Cardiac images were acquired with the traditional OS-CMR sequence (OS bh-cine ), which requires apnoea for acquisition and with two free-breathing OS-CMR sequences: a high-resolution single-shot sequence (OS fb-ss ) and a real-time cine sequence (OS fb-rtcine ). MAIN OUTCOME MEASURES: Myocardial oxygenation response at the end of the paced breathing period and at the 30 s timepoint during the subsequent apnoea, reflecting the time of successful intubation in a clinical setting. RESULTS: The paced breathing followed by five deep breaths significantly reduced myocardial oxygenation, which was observed with all three techniques (OS bh-cine -6.0 ±â€Š2.6%, OS fb-ss -12.0 ±â€Š5.9%, OS fb-rtcine -5.4 ±â€Š7.0%, all P  < 0.05). The subsequent vasodilating stimulus of apnoea then significantly increased myocardial oxygenation (OS bh-cine 6.8 ±â€Š3.1%, OS fb-ss 8.4 ±â€Š5.6%, OS fb-rtcine 15.7 ±â€Š10.0%, all P  < 0.01). The free-breathing sequences were reproducible and were not inferior to the original sequence for any stage. CONCLUSION: Breathing manoeuvres simulating induction of general anaesthesia cause dynamic alterations of myocardial oxygenation in young volunteers, which can be quantified continuously with free-breathing OS-CMR. Introducing these new imaging techniques into peri-operative studies may throw new light into the mechanisms of peri-operative perturbations of myocardial tissue oxygenation and ischaemia. VISUAL ABSTRACT: http://links.lww.com/EJA/A922.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Masculino , Adulto , Estudos Prospectivos , Feminino , Imageamento por Ressonância Magnética/métodos , Estudos de Coortes , Respiração , Miocárdio/metabolismo , Anestesia Geral/métodos , Voluntários Saudáveis , Oxigênio/sangue , Oxigênio/metabolismo , Adulto Jovem , Imagem Cinética por Ressonância Magnética/métodos
6.
Quant Imaging Med Surg ; 13(12): 7973-7986, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106267

RESUMO

Background: The rotational direction (RD) of helical blood flow can be classified as either a clockwise (RD+) or counter-clockwise (RD-) flow. We hypothesized that this simple classification might not be sufficient for analysis in vivo and a simultaneous existence of RD+/- may occur. We utilized volumetric velocity-sensitive cardiovascular magnetic resonance imaging (4D flow MRI) to analyze rotational blood flow in the thoracic aorta. Methods: Forty volunteers (22 females; mean age, 41±16 years) and seventeen patients with bicuspid aortic valves (BAVs) (9 females; mean age, 42±14 years) were prospectively included. The RDs and the calculation of the rotating blood volumes (RBVs) in the thoracic aorta were performed using a pathline-projection strategy. Results: We could confirm a mainly clockwise RD in the ascending, descending aorta and in the aortic arch. Furthermore, we found a simultaneous existence of RD+/RD-. The RD+/--volume in the ascending aorta was significantly higher in BAV patients, the mean RD+/RD- percentage was approximately 80%/20% vs. 60%/40% in volunteers (P<0.01). The maximum RBV always occurred during systole. There was significantly more clockwise than counter-clockwise rotational flow in the ascending aorta (P<0.01) and the aortic arch (P<0.01), but no significant differences in the descending aorta (P=0.48). Conclusions: A simultaneous occurrence of RD+/RD- indicates that a simple categorization in either of both is insufficient to describe blood flow in vivo. Rotational flow in the ascending aorta and in the aortic arch differs significantly from flow in the descending aorta. BAV patients show significantly more clockwise rotating volume in the ascending aorta compared to healthy volunteers.

7.
J Chem Phys ; 159(8)2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37615392

RESUMO

To investigate the impact of non-linear interactions on dynamic coarse graining, we study a simplified model system featuring a tracer particle in a complex environment. Using a projection operator formalism and computer simulations, we systematically derive generalized Langevin equations (GLEs) describing the dynamics of this particle. We compare different kinds of linear and non-linear coarse-graining procedures to understand how non-linearities enter reconstructed GLEs and how they influence the coarse-grained dynamics. For non-linear external potentials, we show analytically and numerically that the non-Gaussian parameter and the incoherent intermediate scattering function will not be correctly reproduced by the GLE if a linear projection is applied. This, however, can be overcome by using non-linear projection operators. We also study anharmonic coupling between the tracer and the environment and demonstrate that the reconstructed memory kernel develops an additional trap-dependent contribution. Our study highlights some open challenges and possible solutions in dynamic coarse graining.

9.
Int J Cardiovasc Imaging ; 39(10): 1963-1977, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37322317

RESUMO

Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flowAIM) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flowjet) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flowAIM to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flowAIM method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flowAIM provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR.

10.
MAGMA ; 36(2): 295-308, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37072539

RESUMO

OBJECTIVE: Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS: We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS: The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS: We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Hemodinâmica , Estresse Mecânico
11.
Int J Cardiovasc Imaging ; 39(1): 135-144, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36598693

RESUMO

The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Cicatriz , Água , Estudos Retrospectivos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Aumento da Imagem/métodos
12.
Front Cardiovasc Med ; 9: 1052068, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36568555

RESUMO

Four-dimensional flow magnetic resonance imaging (MRI) has evolved as a non-invasive imaging technique to visualize and quantify blood flow in the heart and vessels. Hemodynamic parameters derived from 4D flow MRI, such as net flow and peak velocities, but also kinetic energy, turbulent kinetic energy, viscous energy loss, and wall shear stress have shown to be of diagnostic relevance for cardiovascular diseases. 4D flow MRI, however, has several limitations. Its long acquisition times and its limited spatio-temporal resolutions lead to inaccuracies in velocity measurements in small and low-flow vessels and near the vessel wall. Additionally, 4D flow MRI requires long post-processing times, since inaccuracies due to the measurement process need to be corrected for and parameter quantification requires 2D and 3D contour drawing. Several machine learning (ML) techniques have been proposed to overcome these limitations. Existing scan acceleration methods have been extended using ML for image reconstruction and ML based super-resolution methods have been used to assimilate high-resolution computational fluid dynamic simulations and 4D flow MRI, which leads to more realistic velocity results. ML efforts have also focused on the automation of other post-processing steps, by learning phase corrections and anti-aliasing. To automate contour drawing and 3D segmentation, networks such as the U-Net have been widely applied. This review summarizes the latest ML advances in 4D flow MRI with a focus on technical aspects and applications. It is divided into the current status of fast and accurate 4D flow MRI data generation, ML based post-processing tools for phase correction and vessel delineation and the statistical evaluation of blood flow.

13.
Eur Radiol ; 32(12): 8597-8607, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35612663

RESUMO

OBJECTIVES: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). METHODS: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). RESULTS: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. CONCLUSION: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. KEY POINTS: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.


Assuntos
Aorta , Hemodinâmica , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Valores de Referência , Voluntários Saudáveis , Estresse Mecânico
14.
Front Cardiovasc Med ; 9: 800720, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35282374

RESUMO

Introduction: In patients with chronic coronary syndromes, hyperventilation followed by apnea has been shown to unmask myocardium susceptible to inducible deoxygenation. The aim of this study was to assess whether such a provoked response is co-localized with myocardial dysfunction. Methods: A group of twenty-six CAD patients with a defined stenosis (quantitative coronary angiography > 50%) underwent a cardiovascular magnetic resonance (CMR) exam prior to revascularization. Healthy volunteers older than 50 years served as controls (n = 12). Participants hyperventilated for 60s followed by brief apnea. Oxygenation-sensitive images were analyzed for changes in myocardial oxygenation and strain. Results: In healthy subjects, hyperventilation resulted in global myocardial deoxygenation (-10.2 ± 8.2%, p < 0.001) and augmented peak circumferential systolic strain (-3.3 ± 1.6%, p < 0.001). At the end of apnea, myocardial signal intensity had increased (+9.1 ± 5.3%, p < 0.001) and strain had normalized to baseline. CAD patients had a similar global oxygenation response to hyperventilation (-5.8 ± 9.6%, p = 0.085) but showed no change in peak strain from their resting state (-1.3 ± 1.6%), which was significantly attenuated in comparison the strain response observed in controls (p = 0.008). With apnea, the CAD patients showed an attenuated global oxygenation response to apnea compared to controls (+2.7 ± 6.2%, p < 0.001). This was accompanied by a significant depression of peak strain (3.0 ± 1.7%, p < 0.001), which also differed from the control response (p = 0.025). Regional analysis demonstrated that post-stenotic myocardium was most susceptible to de-oxygenation and systolic strain abnormalities during respiratory maneuvers. CMR measures at rest were unable to discriminate post-stenotic territory (p > 0.05), yet this was significant for both myocardial oxygenation [area under the curve (AUC): 0.88, p > 0.001] and peak strain (AUC: 0.73, p = 0.023) measured with apnea. A combined analysis of myocardial oxygenation and peak strain resulted in an incrementally higher AUC of 0.91, p < 0.001 than strain alone. Conclusion: In myocardium of patients with chronic coronary syndromes and primarily intermediate coronary stenoses, cine oxygenation-sensitive CMR can identify an impaired vascular and functional response to a vasoactive breathing maneuver stimulus indicative of inducible ischemia.

15.
Circ Heart Fail ; 15(4): e008903, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35038887

RESUMO

BACKGROUND: The pathophysiology of heart failure with preserved ejection fraction is not well understood, but evidence strongly suggests involvement of microvascular dysfunction. We studied the myocardial oxygenation reserve as a direct marker of coronary vascular function and its relation to myocardial deformation and tissue characteristics by cardiovascular magnetic resonance (CMR). METHODS: In a dual-center case-control study, patients with heart failure and preserved ejection fraction (>50%) and healthy controls older than 50 years underwent quantitative CMR for ventricular volumes and functional assessment with feature tracking, as well as tissue characterization (T1, T2, extracellular volume). Coronary vascular function was measured by oxygenation-sensitive (OS)-CMR of the myocardial oxygenation response to a vasoactive breathing maneuver. RESULTS: Twenty-nine patients completed the CMR exam. Compared with cutoffs derived from 12 control subjects, circumferential peak strain was attenuated in 97% of patients. Native T1 was elevated in 93%, extracellular volume was elevated in 83%. Sixty-six percent of patients revealed either regional or global myocardial edema, defined by an increased myocardial T2. An attenuated global myocardial oxygenation reserve (<4.4%) was observed in 96% of the patients (1.7±3.9% versus 9.1±5.3% in controls, P<0.001). This was correlated with septal wall thickness (r=-0.54, P=0.003), edema (myocardial T2; ß=-0.26% oxygenation-sensitive/ms [95% CI, -0.49 to -0.03], P=0.029), and reduced diastolic strain rate (ß=1.50% oxygenation-sensitive/s-1 [95% CI, 0.06-2.90], P=0.042). CONCLUSIONS: In patients with clinical heart failure with preserved ejection fraction, vascular dysfunction as measured by an attenuated myocardial oxygenation reserve is associated with myocardial edema, a thicker septum, and diastolic dysfunction. A quantitative comprehensive CMR exam including oxygenation-sensitive-CMR allows for comprehensive imaging-based phenotyping of heart failure with preserved ejection fraction.


Assuntos
Insuficiência Cardíaca , Biomarcadores , Estudos de Casos e Controles , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes , Volume Sistólico/fisiologia , Função Ventricular Esquerda
16.
Front Cardiovasc Med ; 8: 743849, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34712713

RESUMO

Background: Coronary autoregulation is a feedback system, which maintains near-constant myocardial blood flow over a range of mean arterial pressure (MAP). Yet in emergency or peri-operative situations, hypotensive or hypertensive episodes may quickly arise. It is not yet established how rapid blood pressure changes outside of the autoregulation zone (ARZ) impact left (LV) and right ventricular (RV) function. Using cardiovascular magnetic resonance (CMR) imaging, measurements of myocardial tissue oxygenation and ventricular systolic and diastolic function can comprehensively assess the heart throughout a range of changing blood pressures. Design and methods: In 10 anesthetized swine, MAP was varied in steps of 10-15 mmHg from 29 to 196 mmHg using phenylephrine and urapidil inside a 3-Tesla MRI scanner. At each MAP level, oxygenation-sensitive (OS) cine images along with arterial and coronary sinus blood gas samples were obtained and blood flow was measured from a surgically implanted flow probe on the left anterior descending coronary artery. Using CMR feature tracking-software, LV and RV circumferential systolic and diastolic strain parameters were measured from the myocardial oxygenation cines. Results: LV and RV peak strain are compromised both below the lower limit (LV: Δ1.2 ± 0.4%, RV: Δ4.4 ± 1.2%, p < 0.001) and above the upper limit (LV: Δ2.1 ± 0.4, RV: Δ5.4 ± 1.4, p < 0.001) of the ARZ in comparison to a baseline of 70 mmHg. LV strain demonstrates a non-linear relationship with invasive and non-invasive measures of oxygenation. Specifically for the LV at hypotensive levels below the ARZ, systolic dysfunction is related to myocardial deoxygenation (ß = -0.216, p = 0.036) in OS-CMR and both systolic and diastolic dysfunction are linked to reduced coronary blood flow (peak strain: ß = -0.028, p = 0.047, early diastolic strain rate: ß = 0.026, p = 0.002). These relationships were not observed at hypertensive levels. Conclusion: In an animal model, biventricular function is compromised outside the coronary autoregulatory zone. Dysfunction at pressures below the lower limit is likely caused by insufficient blood flow and tissue deoxygenation. Conversely, hypertension-induced systolic and diastolic dysfunction points to high afterload as a cause. These findings from an experimental model are translatable to the clinical peri-operative environment in which myocardial deformation may have the potential to guide blood pressure management, in particular at varying individual autoregulation thresholds.

17.
J Cardiovasc Magn Reson ; 23(1): 94, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34247640

RESUMO

BACKGROUND: The native balanced steady state with free precession (bSSFP) magnetic resonance angiography (MRA) technique has been shown to provide high diagnostic image quality for thoracic aortic disease. This study compares a 3D radial respiratory self-navigated native MRA (native-SN-MRA) based on a bSSFP sequence with conventional Cartesian, 3D, contrast-enhanced MRA (CE-MRA) with navigator-gated respiration control for image quality of the entire thoracic aorta. METHODS: Thirty-one aortic native-SN-MRA were compared retrospectively (63.9 ± 10.3 years) to 61 CE-MRA (63.1 ± 11.7 years) serving as a reference standard. Image quality was evaluated at the aortic root/ascending aorta, aortic arch and descending aorta. Scan time was recorded. In 10 patients with both MRA sequences, aortic pathologies were evaluated and normal and pathologic aortic diameters were measured. The influence of artifacts on image quality was analyzed. RESULTS: Compared to the overall image quality of CE-MRA, the overall image quality of native-SN-MRA was superior for all segments analyzed (aortic root/ascending, p < 0.001; arch, p < 0.001, and descending, p = 0.005). Regarding artifacts, the image quality of native-SN-MRA remained superior at the aortic root/ascending aorta and aortic arch before and after correction for confounders of surgical material (i.e., susceptibility-related artifacts) (p = 0.008 both) suggesting a benefit in terms of motion artifacts. Native-SN-MRA showed a trend towards superior intraindividual image quality, but without statistical significance. Intraindividually, the sensitivity and specificity for the detection of aortic disease were 100% for native-SN-MRA. Aortic diameters did not show a significant difference (p = 0.899). The scan time of the native-SN-MRA was significantly reduced, with a mean of 05:56 ± 01:32 min vs. 08:51 ± 02:57 min in the CE-MRA (p < 0.001). CONCLUSIONS: Superior image quality of the entire thoracic aorta, also regarding artifacts, can be achieved with native-SN-MRA, especially in motion prone segments, in addition to a shorter acquisition time.


Assuntos
Aorta Torácica , Doenças da Aorta , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Meios de Contraste , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Sci Rep ; 11(1): 11464, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34075096

RESUMO

The presence of deoxygenated hemoglobin (Hb) results in a drop in T2 and T2* in magnetic resonance imaging (MRI), known as the blood oxygenation level-dependent (BOLD-)effect. The purpose of this study was to investigate if deoxygenated myoglobin (Mb) exerts a BOLD-like effect. Equine Met-Mb powder was dissolved and converted to oxygenated Mb. T1, T2, T2*-maps and BOLD-bSSFP images at 3Tesla were used to scan 22 Mb samples and 12 Hb samples at room air, deoxygenation, reoxygenation and after chemical reduction. In Mb, T2 and T2* mapping showed a significant decrease after deoxygenation (- 25% and - 12%, p < 0.01), increase after subsequent reoxygenation (+ 17% and 0% vs. room air, p < 0.01), and finally a decrease in T2 after chemical reduction (- 28%, p < 0.01). An opposite trend was observed with T1 for each stage, while chemical reduction reduced BOLD-bSSFP signal (- 3%, p < 0.01). Similar deflections were seen at oxygenation changes in Hb. The T1 changes suggests that the oxygen content has been changed in the specimen. The shortening of transverse relaxation times in T2 and T2*-mapping after deoxygenation in Mb specimens are highly indicative of a BOLD-like effect.


Assuntos
Hemoglobinas/química , Imageamento por Ressonância Magnética , Mioglobina/química , Oxigênio/química , Animais , Hemoglobinas/metabolismo , Cavalos , Humanos , Mioglobina/sangue , Oxigênio/sangue
19.
Radiology ; 299(1): 150-158, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33620288

RESUMO

Background Often used for T1 mapping of hip cartilage, three-dimensional (3D) dual-flip-angle (DFA) techniques are highly sensitive to flip angle variations related to B1 inhomogeneities. The authors hypothesized that 3D magnetization-prepared 2 rapid gradient-echo (MP2RAGE) MRI would help provide more accurate T1 mapping of hip cartilage at 3.0 T than would 3D DFA techniques. Purpose To compare 3D MP2RAGE MRI with 3D DFA techniques using two-dimensional (2D) inversion recovery T1 mapping as a standard of reference for hip cartilage T1 mapping in phantoms, healthy volunteers, and participants with hip pain. Materials and Methods T1 mapping at 3.0 T was performed in phantoms and in healthy volunteers using 3D MP2RAGE MRI and 3D DFA techniques with B1 field mapping for flip angle correction. Participants with hip pain prospectively (July 2019-January 2020) underwent indirect MR arthrography (with intravenous administration of 0.2 mmol/kg of gadoterate meglumine), including 3D MP2RAGE MRI. A 2D inversion recovery-based sequence served as a T1 reference in phantoms and in participants with hip pain. In healthy volunteers, cartilage T1 was compared between 3D MP2RAGE MRI and 3D DFA techniques. Paired t tests and Bland-Altman analysis were performed. Results Eleven phantoms, 10 healthy volunteers (median age, 27 years; range, 26-30 years; five men), and 20 participants with hip pain (mean age, 34 years ± 10 [standard deviation]; 17 women) were evaluated. In phantoms, T1 bias from 2D inversion recovery was lower for 3D MP2RAGE MRI than for 3D DFA techniques (mean, 3 msec ± 11 vs 253 msec ± 85; P < .001), and, unlike 3D DFA techniques, the deviation found with MP2RAGE MRI did not correlate with increasing B1 deviation. In healthy volunteers, regional cartilage T1 difference (109 msec ± 163; P = .008) was observed only for the 3D DFA technique. In participants with hip pain, the mean T1 bias of 3D MP2RAGE MRI from 2D inversion recovery was -23 msec ± 31 (P < .001). Conclusion Compared with three-dimensional (3D) dual-flip-angle techniques, 3D magnetization-prepared 2 rapid gradient-echo MRI enabled more accurate T1 mapping of hip cartilage, was less affected by B1 inhomogeneities, and showed high accuracy against a T1 reference in participants with hip pain. © RSNA, 2021.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste , Feminino , Gadolínio DTPA , Voluntários Saudáveis , Humanos , Masculino , Medição da Dor , Imagens de Fantasmas , Estudos Prospectivos
20.
ESC Heart Fail ; 7(5): 2637-2649, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32686332

RESUMO

AIMS: Heart failure with preserved ejection fraction is still a diagnostic and therapeutic challenge, and accurate non-invasive diagnosis of left ventricular (LV) diastolic dysfunction (DD) remains difficult. The current study aimed at identifying the most informative cardiovascular magnetic resonance (CMR) parameters for the assessment of LVDD. METHODS AND RESULTS: We prospectively included 50 patients and classified them into three groups: with DD (DD+, n = 15), without (DD-, n = 26), and uncertain (DD±, n = 9). Diagnosis of DD was based on echocardiographic E/E', invasive LV end-diastolic pressure, and N-terminal pro-brain natriuretic peptide. CMR was performed at 1.5 T to assess LV and left atrial (LA) morphology, LV diastolic strain rate (SR) by tissue tracking and tagging, myocardial peak velocities by tissue phase mapping, and transmitral inflow profile using phase contrast techniques. Statistics were performed only on definitive DD+ and DD- (total number 41). DD+ showed enlarged LA with LA end-diastolic volume/height performing best to identify DD+ with a cut-off value of ≥0.52 mL/cm (sensitivity = 0.71, specificity = 0.84, and area under the receiver operating characteristic curve = 0.75). DD+ showed significantly reduced radial (inferolateral E peak: DD-: -14.5 ± 6.5%/s vs. DD+: -10.9 ± 5.9%/s, P = 0.04; anterolateral A peak: DD-: -4.2 ± 1.6%/s vs. DD+: -3.1 ± 1.4%/s, P = 0.04) and circumferential (inferolateral A peak: DD-: 3.8 ± 1.2%/s vs. DD+: 2.8 ± 0.8%/s, P = 0.007; anterolateral A peak: DD-: 3.5 ± 1.2%/s vs. DD+: 2.5 ± 0.8%/s, P = 0.048) SR in the basal lateral wall assessed by tissue tracking. In the same segments, DD+ showed lower peak myocardial velocity by tissue phase mapping (inferolateral radial peak: DD-: -3.6 ± 0.7 ms vs. DD+: -2.8 ± 1.0 ms, P = 0.017; anterolateral longitudinal peak: DD-: -5.0 ± 1.8 ms vs. DD+: -3.4 ± 1.4 ms, P = 0.006). Tagging revealed reduced global longitudinal SR in DD+ (DD-: 45.8 ± 12.0%/s vs. DD+: 34.8 ± 9.2%/s, P = 0.022). Global circumferential and radial SR by tissue tracking and tagging, LV morphology, and transmitral flow did not differ between DD+ and DD-. CONCLUSIONS: Left atrial size and regional quantitative myocardial deformation applying CMR identified best patients with DD.


Assuntos
Disfunção Ventricular Esquerda , Diástole , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA