Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 134: 410-415, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29107516

RESUMO

Gamma-ray emission probabilities for 243Am were published in 1996. Three new gamma transitions were then found: 46.84, 98.36 and 102.02keV. In the last evaluation by the Decay Data Evaluation Project, the emission probabilities of 46.84 and 102.02keV transitions were not included. Alpha-gamma coincidence measurements have been now used to check and revise the values for these two transitions and their emission probabilities. The emissions of the 31.13, 43.53, 74.66, 86.71 and 141.89keV transitions were also studied.

2.
Radiat Prot Dosimetry ; 167(1-3): 143-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25920780

RESUMO

Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for the (222)Rn concentrations varied from 0 to 150 Bq l(-1), while the levels of (226)Ra were in general very low. This indicates that (222)Rn is coming from the decay of the undissolved (226)Ra existing in the rocks and deep layers of the aquifers, being later transported by diffusion in water.


Assuntos
Radiação de Fundo , Dióxido de Carbono/análise , Dióxido de Carbono/química , Água Subterrânea/química , Radônio/análise , Radônio/química , Difusão , Água Subterrânea/análise , Marcação por Isótopo/métodos , Monitoramento de Radiação/métodos , Resíduos Radioativos , Gerenciamento de Resíduos
3.
Appl Radiat Isot ; 87: 328-30, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24315085

RESUMO

Improvements to the conventional methods for alpha-particle spectrometry measurement and analysis have recently been implemented in our laboratory. They include the application of corrections for energy drift in long-duration measurements, the development and application of an efficient deconvolution method for complex alpha spectra using the new computer code ALFITeX, an alpha-gamma coincidence system using a dual-parameter multichannel analyzer, and the digitization of this coincidence system.

4.
Appl Radiat Isot ; 82: 308-13, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24140879

RESUMO

Measurements of alpha-gamma coincidences have usually been carried out using a single channel to detect alpha-particles of a given energy, and a multichannel analyser for the detection of the corresponding coincident gamma-rays. An alpha-gamma coincidence chamber coupled to the electronic chain ending with a dual-parameter multichannel analyser has been developed and optimized. This system simultaneously stores alpha-particle, gamma-ray, and alpha-gamma coincidence spectra, which allows a general analysis to be made of the degree of coincidence between each alpha-particle and each gamma-ray emission. With this technique, a two-dimensional spectrum was obtained and analysed using "contour graphics". An application to the study of the decay scheme of (241)Am is described.

5.
Appl Radiat Isot ; 81: 49-52, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23578908

RESUMO

The analysis of solid environmental samples by α-particle spectrometry generally involves processes requiring an initial treatment to destroy the complexes in the matrix, and dissolve the radionuclides of interest. This study compared the activities obtained for several natural radionuclides ((238)U, (234)U, (230)Th, (226)Ra, and (210)Po) in previously well-characterized materials, using two procedures: acid leaching and digestion in a microwave oven. The measured activities were in general very similar for the two procedures, with a strong statistical correlation between the two sets of values.


Assuntos
Ácidos/química , Partículas alfa , Calefação/métodos , Radioisótopos/análise , Radioisótopos/efeitos da radiação , Radiometria/métodos , Micro-Ondas , Pós/análise , Pós/química , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Appl Radiat Isot ; 73: 32-43, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23268207

RESUMO

Accurate dating of samples by alpha spectrometry presupposes that the dated system behaved as closed and that no allochthonous (232)Th was provided to the system. Therefore the selection of appropriate samples is a fundamental task that will determine the reliability and accuracy or not of the results. In this paper, by means of a thorough characterisation, those petrological and chemical variables that allow the preselection of the most suitable samples to be dated have been identified and used to calculate the sample quality index.

7.
Appl Radiat Isot ; 70(5): 868-71, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22336296

RESUMO

We studied the applicability of the Monte Carlo code DETEFF for the efficiency calibration of detectors for in situ gamma-ray spectrometry determinations of ground deposition activity levels. For this purpose, the code DETEFF was applied to a study case, and the calculated (137)Cs activity deposition levels at four sites were compared with published values obtained both by soil sampling and by in situ measurements. The (137)Cs ground deposition levels obtained with DETEFF were found to be equivalent to the results of the study case within the uncertainties involved. The code DETEFF could thus be used for the efficiency calibration of in situ gamma-ray spectrometry for the determination of ground deposition activity using the uniform slab model. It has the advantage of requiring far less simulation time than general Monte Carlo codes adapted for efficiency computation, which is essential for in situ gamma-ray spectrometry where the measurement configuration yields low detection efficiency.


Assuntos
Método de Monte Carlo , Espectrometria gama/métodos , Calibragem
8.
Appl Radiat Isot ; 68(2): 355-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19892558

RESUMO

Four general Monte Carlo codes (GEANT3, PENELOPE, MCNP and EGS4) and five dedicated packages for efficiency determination in gamma-ray spectrometry (ANGLE, DETEFF, GESPECOR, ETNA and EFFTRAN) were checked for equivalence by applying them to the calculation of efficiency transfer (ET) factors for a set of well-defined sample parameters, detector parameters and energies typically encountered in environmental radioactivity measurements. The differences between the results of the different codes never exceeded a few percent and were lower than 2% in the majority of cases.


Assuntos
Algoritmos , Radiometria/instrumentação , Radiometria/métodos , Software , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Appl Radiat Isot ; 68(2): 360-3, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19897375

RESUMO

To study the influence of the source's chemical composition on the self-attenuation corrections during the activity quantification of low-energy gamma-ray emitters (< 60keV) in soil samples, we conducted a Monte Carlo-based hypothetical proficiency test in which different analytical laboratories analyze a soil sample, assuming the same density but a different chemical composition. The bias in the activity values was between 4% and 70%, with more than 50% of these results being unacceptable. Our work shows that collecting the detailed chemical composition of the samples is an essential issue to be considered by analytical laboratories that use the Monte Carlo method for the calculation of self-attenuation corrections.


Assuntos
Artefatos , Radiometria/métodos , Poluentes Radioativos do Solo/análise , Raios gama , Método de Monte Carlo , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Appl Radiat Isot ; 67(5): 817-20, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19243961

RESUMO

Source thickness is important in determinations of gross alpha and beta activities in soil or water samples because of self-absorption and energy losses. Its influence was studied theoretically, experimentally, and with Monte Carlo simulations. No problems were found for gross beta activity determinations using sources with mass thicknesses up to 25 mg/cm(2). However, to simultaneously determine gross alpha activity, the results appear to indicate that about 10 mg/cm(2) should be the upper limit to avoid problems.


Assuntos
Partículas alfa , Partículas beta , Solo/análise , Água/análise , Absorção , Doses de Radiação
11.
Appl Radiat Isot ; 67(5): 953-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19233661

RESUMO

Coal and charcoal present similar physical and chemical characteristics. There is no standardized procedure to distinguish them. However, their differences in age and origin result in several differences in their natural radionuclide content. Moreover, charcoal can be contaminated with fallout. In this work, activity concentrations of (228)Th, (226)Ra, (40)K, and (137)Cs were determined in charcoal and coal samples in order to obtain evidence to distinguish the two kinds of sample.


Assuntos
Carvão Vegetal/análise , Radioisótopos/análise , Radioisótopos de Césio/análise , Potássio/análise , Monitoramento de Radiação , Radônio/análise , Tório/análise
12.
Appl Radiat Isot ; 66(6-7): 764-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18359236

RESUMO

In an intercomparison exercise, the Monte Carlo codes most commonly used in gamma-ray spectrometry today were compared with each other in order to gauge the differences between them in terms of typical applications. No reference was made to experimental data; instead, the aim was to confront the codes with each other, as they were applied to the calculation of full-energy-peak and total efficiencies. Surprising differences between the results of different codes were revealed.

13.
Appl Radiat Isot ; 66(6-7): 804-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18353659

RESUMO

The thickness of charged-particle emitting sources can be determined by varying the incidence angle of particles using silicon semiconductor detectors. The differences in energy between the peaks for an alpha emission measured with different incident angles are due to the energy loss of alpha particles in the source. These shifts can thus be used to estimate the source thickness. A new detection chamber has been constructed for this purpose. Its advantage is the registration of the alpha particles emitted from a given source using up to three different detectors simultaneously. Monte Carlo simulation was used to help to determine the best measurement conditions and interpret the results.

14.
Appl Radiat Isot ; 64(10-11): 1319-22, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16549348

RESUMO

The code PENELOPE is applied here to the efficiency calibration exercise described in the EUROMET project 428 [Lépy et al., 2001. Appl. Radiat. Isot. 55, 493]. We evaluated the peak efficiencies for a coaxial HPGe detector in the range 60-2000 keV, for point sources located at various distances from the detector and for a cylindrical box containing two different matrixes: a low-density silica and a hydrochloric acid solution. After an optimization of several detector parameters, the results were in good agreement with the experimental values.


Assuntos
Algoritmos , Germânio/efeitos da radiação , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Software , Espectrometria gama/instrumentação , Espectrometria gama/normas , Calibragem/normas , Análise de Falha de Equipamento/métodos , Internacionalidade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador , Espectrometria gama/métodos , Transdutores
15.
Appl Radiat Isot ; 50(6): 1049-55, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10355106

RESUMO

Consumption of bottled mineral water is a growing practice and is sometimes a necessity rather than a choice. In this work, a study of the radioactive content of a wide selection of commercial bottled mineral waters for human intake was carried out. The origins of the analyzed waters were very different, coming from various locations in France, Portugal and Spain. Their total alpha and beta activity concentrations were determined and also gamma spectrometry was used to detect some radionuclides. In some cases, the waters presented high values of the total alpha and beta activity concentrations surpassing the reference levels established by the CSN, the Spanish. Regulatory Organization. In these cases, a determination of uranium and 226Ra was also performed by using low-level liquid scintillation counting. The results revealed a strong correlation between radioactive content and dry residue, and lead one to conclude that high radioactive content is mainly related to the mineralization in waters of underground origin.


Assuntos
Águas Minerais/análise , Poluentes Radioativos da Água/análise , Partículas alfa , Partículas beta , Raios gama , Humanos , Análise de Regressão , Reprodutibilidade dos Testes , Segurança , Contagem de Cintilação/métodos , Espanha , Espectrometria gama
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA