Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Biomedicines ; 12(2)2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38398058

RESUMO

The Rh system, including the highly immunogenic D antigen, is one of the clinically most important blood group systems in transfusion medicine. Numerous alleles of the RHD gene are associated with variant RhD phenotypes. In case of Rh incompatibility, some of them can induce hemolytic transfusion reactions and hemolytic disease of the fetus and newborn. Thus, accurate blood group diagnostics are critical for safe transfusion therapy. We characterized phenotypes of four individuals revealing weakened D expression during routine pre-transfusion testing. Standard gel card matrix techniques with monoclonal and polyclonal anti-D antibodies were used for serological typing, complemented using D epitope and antigen density analysis. Genotyping employing PCR with sequence-specific primers, genomic and allele-specific Sanger sequencing and in silico protein analysis were performed. Four novel RHD alleles associated with weak D or partial D phenotypes were identified. One of the mutations is predicted to disrupt the terminal stop codon and result in an elongated translation of the mutant D protein that phenotypically exhibits a loss of D epitopes. Furthermore, a hybrid gene formed with the homologue RHCE gene is described. The presented data enhances the understanding of the Rh system and may contribute to continued advances in blood group diagnostics.

2.
Am J Respir Crit Care Med ; 209(8): 995-1000, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38078854

RESUMO

Rationale: Passenger lymphocyte syndrome (PLS) may complicate minor ABO mismatched lung transplantation (LuTX) via donor-derived red cell antibody-induced hemolysis.Objectives: To ascertain the incidence and specificity of PLS-relevant antibodies among the study population as well as the dynamics of hemolysis parameters and the transfusion requirement of patients with or without PLS.Methods: In this cohort study, 1,011 patients who received LuTX between January 2010 and June 2019 were studied retrospectively. Prospectively, 87 LuTX (July 2019 to June 2021) were analyzed. Postoperative ABO antibody and hemolytic marker determinations, transfusion requirement, and duration of postoperative hospital care were analyzed. Retrospectively, blood group A recipients of O grafts with PLS were compared with those without.Measurements and Main Results: PLS affected 18.18% (retrospective) and 30.77% (prospective) of A recipients receiving O grafts, 5.13% of B recipients of O grafts, and 20% of AB patients receiving O transplants. Anti-A and anti-A1 were the predominant PLS-inducing antibodies, followed by anti-B and anti-A,B. Significantly lower hemoglobin values (median, 7.4 vs. 8.3 g/dl; P = 0.0063) and an approximately twice as high percentage of patients requiring blood transfusions were seen in PLS. No significant differences in other laboratory markers, duration of hospital stay, or other complications after LuTX were registered.Conclusions: Minor ABO incompatible LuTX recipients are at considerable risk of developing clinically significant PLS. Post-transplant monitoring combining red cell serology and hemolysis marker determination appears advisable so as not to overlook hemolytic episodes that necessitate antigen-negative transfusion therapy.


Assuntos
Hemólise , Transplante de Pulmão , Humanos , Incompatibilidade de Grupos Sanguíneos/complicações , Estudos Retrospectivos , Estudos de Coortes , Estudos Prospectivos , Linfócitos , Transplante de Pulmão/efeitos adversos
3.
Transfus Med Hemother ; 50(4): 294-302, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37767286

RESUMO

Introduction: The coronavirus disease (COVID-19) pandemic gave rise to studies investigating the association of ABO blood group with COVID-19 susceptibility. It is hypothesized that ABO antibodies might play a role in neutralizing SARS-CoV-2. However, ABO antibodies were exclusively analyzed in blood samples. Investigation of ABO antibodies in saliva, an easy-to-obtain surrogate for respiratory secretions, may provide novel insights into mucosal immunity crucial in early defense against respiratory pathogens. Methods: In this study, saliva and serum samples from healthy individuals with known blood groups were investigated using a flow cytometric method for separate anti-A/anti-B IgA, IgM, and IgG class antibody detection. Saliva samples were additionally tested using hemagglutination-based neutral and indirect anti-human globulin test gel cards. This method comparison was complemented by dilution experiments with a high-titer anti-A/anti-B WHO standard. Results: In saliva, IgA was the most abundant ABO antibody class, followed by IgM; IgG was detected only in low levels in all non-AB blood types. In serum, IgM was the predominant ABO antibody class in all non-AB blood types, followed by IgA and IgG, the latter mainly detected in group O individuals. Saliva and serum samples of group O individuals yielded the highest variability of ABO-specific antibody levels. Regardless of sample material and blood type, major interindividual differences in ABO antibody reactivities were recorded. Antibody levels correlated moderately between these two body fluids. There were no significant sex and age-group differences in ABO antibody levels in both serum and saliva. WHO standard dilution experiments yielded technique-specific limits of detection, illustrating the inherent differences of immunofluorescence versus agglutination. Conclusion: For the first time, salivary ABO antibodies were investigated by separate detection of the three most relevant antibody classes IgA, IgM, and IgG in a healthy cohort. This study opens new perspectives regarding mucosal ABO antibody class profiles and their potential influence on respiratory infections.

4.
Vox Sang ; 118(9): 763-774, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37608544

RESUMO

BACKGROUND AND OBJECTIVES: Human neutrophil antigens (HNAs) are categorized into five systems: HNA-1 to HNA-5. Given the importance of neutrophils in immunity, we sought to create awareness of the role of HNA diagnostic services in managing immune neutropenia and transfusion-related acute lung injury. To provide health communities all around the world with access to these services, we conducted a survey to create a directory of these HNA diagnostic services. MATERIALS AND METHODS: An Excel table-based survey was created to capture information on the laboratory's location and was emailed to 55 individuals with known or possible HNA investigation activity. The collected data were then summarized and analysed. RESULTS: Of contacted laboratories, the surveys were returned from 23 (38.2%) laboratories; 17 have already established HNA diagnostic (of them 12 were regular participants of the International Granulocyte Immunobiology Workshop [ISBT-IGIW]), 4 laboratories were in the process of establishing their HNA investigation and the remaining 2 responder laboratories, did not conduct HNA investigations. In established laboratories, investigation for autoimmune neutropenia (infancies and adults) was the most frequently requested, and antibodies against HNA-1a and HNA-1b were the most commonly detected. CONCLUSION: The directory of survey respondents provides a resource for health professionals wanting to access HNA diagnostic services. The present study offers a comprehensive picture of HNA diagnostics (typing and serology), identifying weak points and areas for improvement for the first time. Identifying more laboratories involved in HNA diagnostics with limited access to international societies in the field will globally improve HNA diagnostics.


Assuntos
Neutropenia , Neutrófilos , Adulto , Humanos , Granulócitos , Anticorpos , Inquéritos e Questionários
5.
J Clin Med ; 11(15)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35956128

RESUMO

Individuals with ABO type O, naturally possessing anti-A and anti-B antibodies in their serum, are underrepresented among patients infected with SARS-CoV-2 compared with healthy controls. The ABO antibodies might play a role in the viral transmission. Therefore, we aimed to quantify anti-A/anti-B, including their subclasses IgM, IgG and IgA, in the serum and saliva of Caucasians (n = 187) after mild COVID-19 to compare them with individuals who had never been infected with SARS-CoV-2. Two samples were collected within two months after the diagnosis (median days: 44) and two months later. ABO antibodies were determined by flow cytometry. Additionally, total IgA in saliva and antibodies specific to SARS-CoV-2 were tested by ELISA. COVID-19 convalescents had significantly lower levels of anti-A/anti-B IgM, IgG and IgA in their serum than control subjects (p < 0.001). Interestingly, no significant differences were observed in saliva. ABO antibody levels remained stable over the period considered. No relation of ABO to the level of SARS-CoV-2-specific antibodies was observed. Total IgA was lower in convalescents than in controls (p = 0.038). Whereas ABO antibodies in the saliva may not contribute to the pathogenesis of COVID-19, individual pre-existing high serum concentrations of anti-A/anti-B may have a protective effect against SARS-CoV-2 infection.

6.
Eur J Obstet Gynecol Reprod Biol ; 271: 271-277, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35259645

RESUMO

OBJECTIVE: To investigate whether women with red blood cell (RBC)1 alloimmunization are more likely to experience bleeding complications during pregnancy or delivery than women without RBC alloimmunization. STUDY DESIGN: Retrospective study involving all singleton pregnancies affected by RBC alloimmunization and without pre-existing maternal bleeding disorders or placenta previa, from 1 July 1999 to 30 June 2019 ("cases"). Only bleedings not related to invasive procedures (amnio- or cordocenteses) were included. Patients who were already at increased risk of pre- or perinatal bleeding due to their medical history (pre-existing bleeding disorders, antithrombotic therapy), or known obstetrics parameters (placental abnormalities etc.) were not included a priori. Cases were compared to controls without RBC alloimmunization, matched for maternal age and body mass index, from the same tertiary referral center in Austria. RESULTS: 130 cases were compared to 130 controls. Cases had significantly more previous pregnancies and miscarriages and their newborns had lower birthweight and were more often transferred to the intensive care unit than newborns of controls. 18/130 (13.8%) cases, compared to 8/130 (6.2%) controls experienced any bleeding during pregnancy or delivery (p = 0.061). Bleeding most often happened during the third trimester (cases: 4.6% vs. controls 0.8%, p = 0.12) and during or after delivery (cases: 7.7% vs. controls: 4.6%, p = 0.168). Binary logistic regression for the prediction of any bleeding complication during pregnancy, delivery or postpartum revealed immunization against RBC antigens as the only independent contributor (p = 0.04). Age, smoking, or previous obstetric history had no influence on the likelihood of maternal bleeding complications. Neither RBC antibody specificity nor titers were predictive of maternal bleeding during pregnancy or delivery. CONCLUSION: Pregnancies affected by RBC alloimmunization might be at increased risk of maternal bleeding complications during pregnancy and delivery.


Assuntos
Placenta Prévia , Placenta , Eritrócitos , Feminino , Humanos , Recém-Nascido , Idade Materna , Gravidez , Estudos Retrospectivos
7.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
8.
Transfus Med Hemother ; 48(3): 183-187, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34177424

RESUMO

BACKGROUND: The development of allo-anti-Rh17 (anti-Hr0) in a -D- phenotype whose red blood cells (RBCs) lack CcEe antigens is most likely triggered by transfusion, transplantation, or pregnancy. Gene conversion is the predominating factor in generating RHD-CE-D and RHCE-D-CE hybrids like -D-. METHODS: We report here immunohematological and obstetrical data from 2 of the 5 pregnancies of a 24-year-old woman presenting with the -D- phenotype with anti-Rh17. Blood group typing, antibody screening, antibody differentiation, direct antiglobulin test (DAT), and antibody titers were performed by routine gel technology and tube testing. Additionally, molecular genetic analysis was performed. Fetal surveillance was done by sonographic evaluation of the fetal middle cerebral artery peak systolic velocity (MCA-PSV). RESULTS: Blood group typing showed O, C-c-D+E-e- and the DAT was negative. DNA sequencing revealed homozygosity for an RHCE-D(3-9)-CE null allele. Anti-Rh17 titers in the fourth pregnancy remained between 1:8 and 1:128, and no signs for a fetal anemia were observed. However, in the fifth pregnancy, the antibody titers increased up to 1:4,096. Signs of moderate fetal anemia were detected and cesarean section was performed at 34 + 6 weeks of gestation. The newborn presented with hemolytic anemia (cord blood hemoglobin [Hb] = 8.5 mg/dL). She received 2 compatible (small) packed RBC concentrates, phototherapy, and intravenous immunoglobulins. CONCLUSION: Our case shows that the risk for hemolytic complications increases with the number of pregnancies of sensitized women. Only people who also lack CcEe antigens are compatible as donors. The role of such rare donors as lifesavers, their freedom, and voluntariness conflict with the urgent need for compatible blood.

9.
Nanoscale ; 12(43): 22097-22106, 2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33118583

RESUMO

The Rh blood group system plays a key role in transfusion and organ transplant medicine. The complex transmembrane Rh polypeptides RhD and RhCE carry numerous antigens, including the extremely immunogenic D antigen. The Rh polypeptides form multimolecular Rh complexes with certain transmembrane and skeletal proteins, with so far only incompletely understood physiological functions. Determination of the energy landscape of individual Rh binding epitopes towards their specific interaction partners as well as their localization across the red blood cell (RBC) membrane requires single molecule approaches including large area high resolution recognition imaging. Atomic force microscopy based molecular recognition force spectroscopy in combination with single molecule recognition imaging fulfills these requirements. For unbiased single molecule results, nano-mechanical influences due to cell elasticity have to be eliminated. This is realized by generation of ultra flat erythrocyte ghosts on a solid support. We developed a protocol for the preparation of complete ultraflat erythrocyte ghosts and determined the molecular binding behaviour of different anti-D antibodies towards their binding epitopes on RhD positive and negative erythrocytes. Performing optimized topography and recognition imaging at 16 Mpixel resolution allowed localisation of individual RhD molecules at the single molecule level across an entire RBC. A map of Rh antigens across integer ultraflat RBC ghosts was generated with nanometer resolution. Here we show a homogeneous distribution on rim and dimple regions with comparable receptor densities. Furthermore, differences in the energy landscape between specific monoclonal antibodies were determined at the single molecule level.


Assuntos
Membrana Eritrocítica , Eritrócitos , Anticorpos Monoclonais , Epitopos
10.
Transfus Med Hemother ; 47(1): 80-87, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32110198

RESUMO

BACKGROUND: As some errors in pretransfusion testing remain unrecognized, error rates and the resulting need for corrective measures are probably underestimated. External quality assessment (EQA) schemes could provide valuable input for identifying error-prone laboratory tests because they are designed to monitor test performance and errors. So far, however, there are only limited published data on error rates in such schemes. METHODS: The types and incidence of incorrect results in an EQA scheme for red cell immunohematology with 187 participating laboratories were examined. The results of 58 distributions between 1999 and 2017 were evaluated, considering also the employed determination methods. RESULTS: Out of a total of 58,726 results, 563 (0.96%) were incorrect. Error rates were 5.45% for antibody identification, 1.39% for Rh phenotyping, 0.83% for serologic cross-match, 0.60% for direct antiglobulin test, 0.20% for Kell phenotyping, 0.16% for antibody screening, and 0.14% for ABO phenotyping. During the observation period, 53 participants reported error-free results, while 37 reported one incorrect result and 97 repeatedly reported incorrect results for one or more analytes. Error rates obtained by manual methods significantly surpassed those obtained by automated methods (1.04 vs. 0.42%). The introduction of double testing with two different systems reduced error rates in Rh phenotyping from 1.55 to 0.50%. CONCLUSION: Risk assessment should consider that error rates in pretransfusion test results vary. These data delineate the error risk potential of individual laboratory tests and thus should aid in tailoring appropriate improvement measures.

11.
Transfus Med Hemother ; 47(1): 94-97, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32110200

RESUMO

BACKGROUND: Routine ABO blood group typing for pre-transfusion testing of a male Austrian patient of Far Eastern origin showed discrepant results with an apparently weak blood group B phenotype and irregular anti-B. MATERIALS AND METHODS: ABH phenotyping and cross-matching was done by standard serologic techniques and levels of H expression were determined by flow cytometry. ABO gene sequencing including regulatory regions as well as analysis of FUT1 (H), FUT2 (Secretor), and FUT3 (Lewis) were carried out. RESULTS: While monoclonal ABO antigen typing indicated blood group O, weak agglutination reactions using polyclonal human anti-B and anti-AB were seen. In reverse typing at room temperature, the plasma was reactive with A1 and A2 RBCs and negative with B and O cells, whereas at 4°C, anti-B reactivity was found. The indirect anti-globulin cross-match of the patient's plasma was positive with group B RBCs and negative with group O RBCs. Sequencing analysis showed the presence of ABO*B.01 (B114) allele and homozygosity for the FUT1 mutation c.551_552delAG. Flow cytometry demonstrated trace amounts of H antigen on the patient's RBCs. CONCLUSION: While a functional B allele was found, analysis of FUT1 and FUT2 genes revealed the presence of a rare para-Bombay genotype OhB. Interestingly, no anti-H but irregular anti-B was found in the patient's plasma, responsible for the positive cross-match with group B RBCs. Even though very rare and not reported for the European population, the presence of an H-deficient phenotype should be considered when investigating individuals with an unusual ABO blood group type.

13.
Clin Biochem ; 63: 72-78, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30447182

RESUMO

BACKGROUND AND OBJECTIVES: Classical neutrophil-reactive antibody testing depends on the quick isolation of neutrophils from freshly taken whole blood. To allow a better logistic preparation before testing, the influence of time interval between venipuncture and cell isolation has been evaluated in this study. MATERIALS AND METHODS: Neutrophils and whole leukocytes were isolated from EDTA whole blood immediately (T0) as well as 4, 8 and 24 h after blood donation (T4, T8 and T24). These cells were tested against reference sera containing antibodies against HNA-1b, -2, -3a and HLA class I using granulocyte aggregation test (GAT), microscopic granulocyte immunofluorescence test (GIFT) and flow-cytometric white blood cell immunofluorescence test (Flow-GIFT/WIFT). RESULTS: GAT was the most error-prone test displaying overall weaker aggregation strengths already at T4 (overall accuracy OA = 0.72, κ = 0.58). GIFT results showed good agreement at T4 (OA = 0.86, κ = 0.79) and remained stable until T8, while test results were slightly impaired at T24 (OA = 0.71, κ = 0.55). Flow-GIFT/WIFT was identified as the most robust screening method, remaining stable even at T24. Calculated ratios (sample/negative control) decreased non-significantly and remained highly above the cut-off in all samples. CONCLUSION: Acceptable time limits for cell isolation are different for each screening method investigated. For GAT, cell isolation should be performed within 4 h, while GIFT tolerates a neutrophil isolation delay of 8 h. Flow-GIFT/WIFT isolation can be performed even after 24 h without impairment of the results. Using the latter test as a stand-alone pre-screening test, whole blood can be used from donors who are not directly accessible.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/sangue , Separação Celular , Neutrófilos/metabolismo , Flebotomia , Humanos , Neutrófilos/citologia , Fatores de Tempo
14.
Haematologica ; 104(3): 632-638, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30237270

RESUMO

Spontaneous Rh blood group changes are a striking sign, reported to occur mainly in patients with hematologic disorders. Upon routine blood grouping, 2 unrelated individuals showed unexplained mixed red cell phenotype regarding the highly immunogenic c antigen (RH4), clinically relevant for blood transfusion and fetomaternal incompatibility. About half of their red cells were c-positive, whereas the other half were c-negative. These apparently hematologically healthy females had no history of transfusion or transplantation, and they tested negative for chimerism. Genotyping of flanking chromosome 1 microsatellites in blood, finger nails, hair, leukocyte subpopulations, and erythroid progenitor cells showed partial loss of heterozygosity encompassing the RHD/RHCE loci, spanning a 1p region of 26.7 or 42.4 Mb, respectively. Remarkably, in one case this was detected in all investigated tissues, whereas in the other, exclusively myeloid cells showed loss of heterozygosity. Both carried the RhD-positive haplotypes CDe and the RhD-negative haplotype cde RHD/RHCE genotypes of single erythroid colonies and dual-color fluorescent in situ hybridization analyses indicated loss of the cde haplotype and duplication of the CDe haplotype in the altered cell line. Accordingly, red cell C antigen (RH2) levels of both propositae were higher than those of heterozygous controls. Taken together, the Rhc phenotype splitting appeared to be caused by deletion of a part of 1p followed by duplication of homologous stretches of the sister chromosome. In one case, this phenomenon was confined to myeloid stem cells, while in the other, a pluripotent stem cell line was affected, demonstrating somatic mosaicism at different stages of ontogenesis.


Assuntos
Transformação Celular Neoplásica/genética , Cromossomos Humanos Par 1 , Mosaicismo , Sistema do Grupo Sanguíneo Rh-Hr/genética , Adulto , Idoso , Feminino , Citometria de Fluxo , Genótipo , Transplante de Células-Tronco Hematopoéticas , Humanos , Hibridização in Situ Fluorescente , Perda de Heterozigosidade , Repetições de Microssatélites , Células Mieloides/metabolismo , Fenótipo
16.
Clin Chem Lab Med ; 56(12): 2039-2046, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30016273

RESUMO

Background ISO 9001 and ISO 15189 have been established as continuative models for quality systems beyond national laws, mandatory standards and guidelines of expert associations regarding analytical and organisational performance of medical laboratories and transfusion services. Although widely used, their impact on laboratory performance has not been investigated. Methods We retrospectively analysed the results of 167 laboratories in 59 distributions of the Austrian red cell immunohaematology external quality assessment (EQA) scheme in the years 1999-2017. The performance for each parameter and trends of individual participants were compared with respect to certification or accreditation status of participants' quality systems and to laboratory type. Results Considering more than 52,000 EQA results, the absence or presence of a laboratory quality management system showed different error rates. Laboratories with ISO 9001 or ISO 15189 certification/accreditation had 0.7% incorrect results, while this rate was doubled without such quality systems (1.4%, p=0.0002). Statistically significant error reductions were seen upon ISO 9001/ISO 15189 implementation (1.3% before vs. 0.7% after; p=0.0468). Transfusion services had fewer errors (0.9%) compared to hospital and independent laboratories (both 1.2%). Conclusions Implementation and maintenance of quality systems according to ISO 9001 or ISO 15189 as well as laboratory specialisation result in better analytical performance as can be seen in immunohaematology EQA results. The conclusion is that these results apply to other laboratory tests and perhaps to other areas of health care.


Assuntos
Alergia e Imunologia/normas , Hematologia/normas , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Áustria , Humanos , Controle de Qualidade , Estudos Retrospectivos
17.
Transfusion ; 55(6 Pt 2): 1411-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25413499

RESUMO

BACKGROUND: D antigen variants may be grouped into partial D, weak D, and DEL types. Cumulative phenotype frequencies of these D variants may approach 1% in certain European regions. Unambiguous and quick identification of D variants is of immediate clinical relevance, with implications for transfusion strategy. STUDY DESIGN AND METHODS: A total of 628 samples with ambiguous serologic results from different immunohematology laboratories throughout the Flanders region, Belgium, were genotyped using a commercially available weak D typing approach. After exclusion of detectable weak D types, molecular RHD exon scanning was performed for the remaining samples, and RHD sequencing was performed in two particular cases. RESULTS: Of all samples investigated, 424 (67.5%) were positive for weak D Type 1, 2, or 3, and 22 cases (3.5%) typed weak D Type 4.0/4.1/4.3, 4.2, 5, 11, 15, or 17. Another 49 (7.8%) samples were partial D variants, with a major proportion being category DVI types (n = 27). One RHD(S103P) sample was identified as high-grade partial D, with DIII-like phenotype and anti-D and anti-C immunization. Additionally, a novel DVI Type 3 (A399T) variant was found. Of the remaining 133 samples mainly tested because of ambiguous serologic D typing results due to recent transfusion, 32 (5.1%) were negative for RHD, and 101 (16.1%) were indistinguishable from wild-type RHD and not investigated further. CONCLUSION: Despite the enormous diversity of RHD alleles, first-line weak D genotyping was remarkably informative, allowing for rapid classification of most samples with conspicuous RhD phenotype in Flanders. The clinical implications are discussed.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Tipagem e Reações Cruzadas Sanguíneas , Variação Genética , Sistema do Grupo Sanguíneo Rh-Hr/genética , Alelos , Bélgica/epidemiologia , Tipagem e Reações Cruzadas Sanguíneas/estatística & dados numéricos , Mapeamento de Epitopos , Genótipo , Humanos , Isoanticorpos/sangue , Dados de Sequência Molecular , Fenótipo , Reação em Cadeia da Polimerase/métodos , Sistema do Grupo Sanguíneo Rh-Hr/imunologia , Imunoglobulina rho(D)
18.
Wien Med Wochenschr ; 164(11-12): 213-9, 2014 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-24962766

RESUMO

In this paper, the design and implementation of an institutional mentoring program for undergraduate medical students at the Medical University of Vienna are presented. Faculty members act as senior mentors in a small group setting enabling also peer mentoring (73.6% of mentees reporting a direct benefit from their co-mentees). Program acceptance by mentees and mentors is very high (71.7% of the mentees and 77.1% of the mentors giving the highest out of four rating categories). The adequacy of this program was studied by analyzing the topics discussed in the mentoring groups: the most frequently covered aspects are diploma thesis, clinical clerkship, studying abroad and career planning. Additionally, sex-specific distributions of mentor recruitment and selection as well as participation by students were documented (e.g., female proportion of 29.9% and 53.2% of mentors and mentees, respectively). Both feedback and content analysis demonstrate the success of this large-scale project.


Assuntos
Educação de Graduação em Medicina/organização & administração , Objetivos , Mentores , Centros Médicos Acadêmicos , Adulto , Atitude do Pessoal de Saúde , Áustria , Escolha da Profissão , Currículo , Docentes de Medicina , Feminino , Humanos , Relações Interprofissionais , Masculino , Projetos Piloto , Avaliação de Programas e Projetos de Saúde , Fatores Sexuais , Inquéritos e Questionários
19.
Transfus Med Hemother ; 41(6): 446-51, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25670932

RESUMO

Many different factors influence the propensity of transfusion recipients and pregnant women to form red blood cell alloantibodies (RBCA). RBCA may cause hemolytic transfusion reactions, hemolytic disease of the fetus and newborn and may be a complication in transplantation medicine. Antigenic differences between responder and foreign erythrocytes may lead to such an immune answer, in part with suspected specific HLA class II associations. Biochemical and conformational characteristics of red blood cell (RBC) antigens, their dose (number of transfusions and pregnancies, absolute number of antigens per RBC) and the mode of exposure impact on RBCA rates. In addition, individual circumstances determine the risk to form RBCA. Responder individuality in terms of age, sex, severity of underlying disease, disease- or therapy-induced immunosuppression and inflammation are discussed with respect to influencing RBC alloimmunization. For particular high-risk patients, extended phenotype matching of transfusion and recipient efficiently decreases RBCA induction and associated clinical risks.

20.
Transfusion ; 53(11 Suppl 2): 2954-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23550956

RESUMO

BACKGROUND: Molecular variant RHD allele analysis is best complemented by detailed characterization of the associated D phenotype. STUDY DESIGN AND METHODS: Variant D types were characterized using molecular typing, RHD sequencing, extended serologic D antigen investigations, and flow cytometric D antigen quantification. RESULTS: We discovered three novel weak D types termed weak D Types 45.1, 75, and 76 with RHD nucleotide substitutions coding for amino acid exchanges in predicted intracellular RhD polypeptide stretches; antigen densities of approximately 1.990, 900, and 240 D sites per red blood cell were found, respectively. Adsorption-elution technique-supported D epitope mapping of these three weak D types demonstrated the expression of all tested D epitopes. Initial molecular typing of the three investigated samples by RHD gene exon scanning polymerase chain reaction using sequence-specific priming yielded a negative reaction for A1193 located in RHD Exon 9 and could be explained by specific mutations for weak D Types 45.1 (C818T, G1195A), 75 (G1194C), and 76 (A1215C). CONCLUSION: All novel weak D types expressed all tested D epitopes. It is of interest that for weak D Types 45.1, 75, and 76, similar alleles with a maximal divergence of one amino acid only, that is, weak D Types 45, 41, and 68, respectively, have been reported so far.


Assuntos
Éxons/genética , Variação Genética , Sistema do Grupo Sanguíneo Rh-Hr/genética , Sistema do Grupo Sanguíneo Rh-Hr/imunologia , Alelos , Doadores de Sangue , Epitopos/genética , Epitopos/imunologia , Eritrócitos/imunologia , Eritrócitos/metabolismo , Dosagem de Genes , Hemaglutinação/genética , Testes de Hemaglutinação , Humanos , Dados de Sequência Molecular , Reação em Cadeia da Polimerase , Sistema do Grupo Sanguíneo Rh-Hr/classificação , Testes Sorológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA