Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Medicine (Baltimore) ; 97(15): e0388, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29642199

RESUMO

BACKGROUND: Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. METHODS: Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120 kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n = 62) or reference protocol (n = 50). Objective and subjective image quality was assessed and compared. RESULTS: Tube voltage was decreased to 100 kV in 47 patients and to 80 kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5 mSv) were significantly decreased in the study group (both P < .001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P < .01). Subjective image quality was comparable without statistically significance. CONCLUSIONS: Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.


Assuntos
Meios de Contraste , Iodo , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos
2.
Rofo ; 189(2): 137-145, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28142179

RESUMO

Purpose The aim was to evaluate a minimum echo time (minTE) protocol for breast magnetic resonance imaging (MRI) in patients with breast lesions compared to a standard TE (nTE) time protocol. Methods Breasts of 144 women were examined with a 1.5 Tesla MRI scanner. Additionally to the standard gradient-echo sequence with nTE (4.8 ms), a variant with minimum TE (1.2 ms) was used in an interleaved fashion which leads to a better temporal resolution and should reduce the scan time by approximately 50 %. Lesion sizes were measured and the signal-to-noise ratio (SNR) as well as the contrast-to-noise ratio (CNR) were calculated. Subjective confidence was evaluated using a 3-point scale before looking at the nTE sequences (1 = very sure that I can identify a lesion and classify it, 2 = quite sure that I can identify a lesion and classify it, 3 = definitely want to see nTE for final assessment) and the subjective image quality of all examinations was evaluated using a four-grade scale (1 = sharp, 2 = slight blur, 3 = moderate blur and 4 = severe blur/not evaluable) for lesion and skin sharpness. Lesion morphology and contrast enhancement were also evaluated. Results With minTE sequences, no lesion was rated with "definitely want to see nTE sequences for final assessment". The difference of the longitudinal and transverse diameter did not differ significantly (p > 0.05). With minTE, lesions and skin were rated to be significantly more blurry (p < 0.01 for lesions and p < 0.05 for skin). There was no difference between both sequences with respect to SNR, CNR, lesion morphology, contrast enhancement and detection of multifocal disease. Conclusion Dynamic breast MRI with a minTE protocol is feasible without a major loss of information (SNR, CNR, lesion morphology, contrast enhancement and lesion sizes) and the temporal resolution can be increased by a factor of 2 using minTE sequences. Key points · Increase of temporal resolution for a better in-flow curve.. · Dynamic breast MRI with a shorter TE time is possible without relevant loss of information.. · Possible decrease of the overall scan time.. Citation Format · Wenkel E, Janka R, Geppert C et al. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images. Fortschr Röntgenstr 2017; 189: 137 - 145.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnica de Subtração , Algoritmos , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Semin Arthritis Rheum ; 46(2): 143-150, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27342772

RESUMO

OBJECTIVE: To define the anatomic distribution of the earliest inflammatory and structural changes in individuals with anti-citrullinated protein antibody (ACPA+) positivity but no signs of arthritis. METHODS: ACPA+ individuals (N = 20) and healthy controls (N = 13) received simultaneous gadolinium-enhanced magnetic resonance imaging (MRI) and high-resolution peripheral quantitative computed tomography (HR-pQCT) of the hands. MRI sequences were scored for synovitis, osteitis, and bone erosions according to the RAMRIS method as well as for presence, localization, and extent of tenosynovitis. Bone erosions were validated by HR-pQCT scanning and related to the inflammatory changes found in the MRI. RESULTS: Tenosynovitis was the most prevalent inflammatory pathology, affecting 80% of ACPA+ individuals but none of the controls. Tenosynovitis at two or more anatomical sites was associated with later development of RA. Synovitis (65%) and osteitis (35%) were present in ACPA+ individuals as well, but at a lower frequency than tenosynovitis. MRI bone erosions were found in 65% of the individuals and additionally confirmed by HR-pQCT. Presence of MRI osteitis was the inflammatory pathology most strongly associated with bone erosions. CONCLUSION: Tenosynovitis is highly prevalent in ACPA+ individuals without arthritis and associated with later development of RA. Small erosions, often linked to osteitis, are also found in ACPA+ individuals without arthritis.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Articulação da Mão/diagnóstico por imagem , Inflamação/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Adulto , Artrite Reumatoide/complicações , Progressão da Doença , Feminino , Humanos , Inflamação/complicações , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Molibdoferredoxina , Imagem Multimodal , Índice de Gravidade de Doença , Tenossinovite/complicações , Tomografia Computadorizada por Raios X
4.
Invest Radiol ; 51(10): 618-23, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27187046

RESUMO

OBJECTIVES: Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. MATERIALS AND METHODS: Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. RESULTS: Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). CONCLUSIONS: Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.


Assuntos
Artefatos , Lesões das Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Osso e Ossos , Artérias Carótidas/diagnóstico por imagem , Meios de Contraste , Feminino , Cabeça/irrigação sanguínea , Cabeça/diagnóstico por imagem , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA