Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Fitoterapia ; 172: 105749, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37972716

RESUMO

Cotton aphids, Aphis gosspyii and cotton jassids, Amrasca biguttula are destructive piercing sucking pests to many strategic crops, especially cotton, not only in Egypt but also all over the world. Using synthetic pesticides to control these pests led to several deleterious impacts. Natural pesticides can be used as a harmless alternative. Nine compounds were isolated from different fractions of Retama raetam using chromatographic techniques and identified by spectroscopic methods as eugenol (1), alpinumisoflavone (2), licoflavone C (3), ephedroidin (4), anagyrine (5), spartiene (6), genistein-8ß-C-glucoside (7), isoprunetin (8) and isoprunetin 7-O-ß-D-glucopyranoside (9). The methanol crude extract and its fractions (hexane, chloroform, ethyl acetate and butanol), as well as the isolated compounds were examined against A. gosspyii and A. biguttula as insecticides. The results showed that chloroform fraction was the most potent fraction against A. gosspyii and A. biguttula, with LC50 values of 65.66 and 64.43 ppm, respectively. As well, compounds 1, 5 and 6 were found to be more active, with LC50 values of 69.84, 25.49 and 27.22 ppm for A. gosspyii and 65.17, 24.07 and 24.78 ppm for A. biguttula, respectively. The most potent compounds (1, 5 and 6) exhibited AChE inhibition toward A. gosspyii compared with the control. So, it can be concluded that the isolated compounds eugenol 1, anagyrine 5 and spartiene 6 are the active principles due to their capability to inhibit AchE activity.


Assuntos
Afídeos , Inseticidas , Animais , Clorofórmio , Eugenol , Estrutura Molecular , Extratos Vegetais/farmacologia
2.
Dent Mater J ; 42(3): 336-342, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-36709987

RESUMO

This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown. PEEK, zirconia, and titanium secondary crowns were fabricated using a CAD/CAM system. Insertion and removal tests of secondary crowns on the primary crown were conducted for 2,000 cycles. The initial retentive forces recorded at the 100th cycle for PEEK, zirconia, and titanium were 13.0±7.9, 2.9±2.6, and 27.6±1.7 N, respectively. The retentive forces of PEEK and zirconia showed no significant difference among all cycles. However, the retentive force of the titanium used as a control decreased (20.3±2.8 N) significantly at the 2,000th cycle. Although the retentive force of PEEK was lower than that of titanium, it was within the range that can provide a suitable retentive force of 5 N for removable dental prostheses.


Assuntos
Coroas , Titânio , Polímeros , Polietilenoglicóis , Cetonas , Zircônio , Desenho Assistido por Computador , Dente Suporte , Análise do Estresse Dentário
3.
J Clin Med ; 10(19)2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34640446

RESUMO

Telescopic systems constructed using computer aided design and computer aided manufacture (CAD/CAM) can overcome many drawbacks associated with conventionally constructed ones. Since retention is considered the most important function of these retainers, this scoping review aimed to discuss and summarize the parameters that affect this function in CAD/CAM-manufactured telescopic crowns and to compare their retention force values with the recommended retention force. An electronic search was done in Pubmed and Google Scholar databases using different keyword combinations to find the related articles. Seventeen articles that follow the eligibility criteria for this review were selected and analyzed for detection of each of the tested parameters and their effect on retention force. The parameters tested in these articles were divided into parameters related to design, manufacturing, material type, and test condition. Regardless of the effect of these parameters, the retention force values recorded in most of the selected studies laid within or were higher than the recommended retention force (2.5-10 N), which indicated the need to design and set the combination of materials of telescopic systems according to oral biomechanics.

4.
Artigo em Inglês | MEDLINE | ID: mdl-29354253

RESUMO

Infants with cleft palate (CP) suffer from several difficulties, one of them is feeding, which prevent infant from maintaining adequate nutrition. Usage of feeding plate, special bottles and nipples has been described to overcome this problem. This article describes steps of constructing a single visit feeding plate for a CP infant. The main objective was to provide an infant with a properly functioning feeding prosthesis and to reduce parents' anxiety originated from multiple dental visits. We can conclude that our feeding plate was successfully achieving the planned objectives.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA