1.
Eur Radiol ; 33(7): 5028-5036, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36719498

RESUMO

OBJECTIVES: To establish a CT lymphangiography method in mice via direct lymph node puncture. METHODS: We injected healthy mice (n = 8) with 50 µl of water-soluble iodine contrast agent (iomeprol; iodine concentration, 350 mg/mL) subcutaneously into the left-rear foot pad (interstitial injection) and 20 µl of the same contrast agent directly into the popliteal lymph node (direct puncture) 2 days later. Additionally, we performed interstitial MR lymphangiography on eight mice as a control group. We calculated the contrast ratio for each lymph node and visually assessed the depiction of lymph nodes and lymphatic vessels on a three-point scale. RESULTS: The contrast ratios of 2-min post-injection images of sacral and lumbar-aortic lymph nodes were 20.7 ± 16.6 (average ± standard deviation) and 17.1 ± 12.0 in the direct puncture group, which were significantly higher than those detected in the CT or MR interstitial lymphangiography groups (average, 1.8-3.6; p = 0.008-0.019). The visual assessment scores for sacral lymph nodes, lumbar-aortic lymph nodes, and cisterna chyli were significantly better in the direct puncture group than in the CT interstitial injection group (p = 0.036, 0.009 and 0.001, respectively). The lymphatic vessels between these structures were significantly better scored in direct puncture group than in the CT or MR interstitial lymphangiography groups at 2 min after injection (all p ≤ 0.05). CONCLUSIONS: In CT lymphangiography in mice, the direct lymph node puncture provides a better delineation of the lymphatic pathways than the CT/MR interstitial injection method. KEY POINTS: • The contrast ratios of 2-min post-injection images in the direct CT lymphangiography group were significantly higher than those of CT/MR interstitial lymphangiography groups. • The visibility of lymphatic vessels in subjective analysis in the direct CT lymphangiography group was significantly better in the direct puncture group than in the CT/MR interstitial lymphangiography groups. • CT lymphangiography with direct lymph node puncture can provide excellent lymphatic delineation with contrast being maximum at 2 min after injection.


Assuntos
Iodo , Linfografia , Animais , Camundongos , Linfografia/métodos , Meios de Contraste/farmacologia , Estudos de Viabilidade , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada por Raios X
2.
BMC Med Imaging ; 23(1): 5, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624404

RESUMO

PURPOSE: To evaluate whether deep learning reconstruction (DLR) accelerates the acquisition of 1.5-T magnetic resonance imaging (MRI) knee data without image deterioration. MATERIALS AND METHODS: Twenty-one healthy volunteers underwent MRI of the right knee on a 1.5-T MRI scanner. Proton-density-weighted images with one or four numbers of signal averages (NSAs) were obtained via compressed sensing, and DLR was applied to the images with 1 NSA to obtain 1NSA-DLR images. The 1NSA-DLR and 4NSA images were compared objectively (by deriving the signal-to-noise ratios of the lateral and the medial menisci and the contrast-to-noise ratios of the lateral and the medial menisci and articular cartilages) and subjectively (in terms of the visibility of the anterior cruciate ligament, the medial collateral ligament, the medial and lateral menisci, and bone) and in terms of image noise, artifacts, and overall diagnostic acceptability. The paired t-test and Wilcoxon signed-rank test were used for statistical analyses. RESULTS: The 1NSA-DLR images were obtained within 100 s. The signal-to-noise ratios (lateral: 3.27 ± 0.30 vs. 1.90 ± 0.13, medial: 2.71 ± 0.24 vs. 1.80 ± 0.15, both p < 0.001) and contrast-to-noise ratios (lateral: 2.61 ± 0.51 vs. 2.18 ± 0.58, medial 2.19 ± 0.32 vs. 1.97 ± 0.36, both p < 0.001) were significantly higher for 1NSA-DLR than 4NSA images. Subjectively, all anatomical structures (except bone) were significantly clearer on the 1NSA-DLR than on the 4NSA images. Also, in the former images, the noise was lower, and the overall diagnostic acceptability was higher. CONCLUSION: Compared with the 4NSA images, the 1NSA-DLR images exhibited less noise, higher overall image quality, and allowed more precise visualization of the menisci and ligaments.


Assuntos
Aprendizado Profundo , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Aceleração
3.
J Cardiovasc Comput Tomogr ; 13(1): 55-61, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30309765

RESUMO

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is an emerging technique to diagnose significant coronary stenosis. However, this procedure has not been reported using single-source 64-row CT. OBJECTIVE: To investigate the radiation dose and the diagnostic performance of dynamic CTP to diagnose significant stenosis by catheter exam. METHODS: We prospectively included 165 patients who underwent CTP exam under adenosine stress using a single-source 64-row CT. MBF was calculated using the deconvolution technique. Quantitative perfusion ratio (QPR) was defined as the myocardial blood flow (MBF) of the myocardium with coronary stenosis divided by the MBF of the myocardium without significant stenosis or infarct. Of the 44 patients who underwent subsequent coronary angiography, we assessed the diagnostic performance to diagnose ≥50% stenosis by quantitative coronary analysis (QCA). RESULTS: The average effective dose of dynamic CTP and the entire scans were 2.5 ±â€¯0.7 and 7.3 ±â€¯1.8 mSv, respectively. The MBF of the myocardium without significant stenosis was 1.20 ±â€¯0.32 ml/min/g, which significantly decreased to 0.98 ±â€¯0.24 ml/min/g (p < 0.01) in the area with ≥50% stenosis by CT angiography. The QPR of the myocardium with QCA ≥50% stenosis was significantly lower than 1 (0.84 ±â€¯0.32, 95% confidence interval (CI), 0.77-0.90, p < 0.001). The accuracy to detect QCA ≥50% stenosis was 82% (95%CI, 74-88%) using CT angiography alone and significantly increased to 87% (95%CI, 80-92%, p < 0.05) including QPR. CONCLUSION: Dynamic myocardial CTP could be performed using 64-row CT with a low radiation dose and would improve the diagnostic performance to detect QCA ≥50% stenosis than CT angiography alone.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
4.
Data Brief ; 21: 953-955, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30426050

RESUMO

This article describes data related to a research article titled "Feasibility of dynamic myocardial CT perfusion using single-source 64-row CT", Tomizawa et al. (in press) [1]. Decrease in the myocardial blood flow could be calculated by performing stress dynamic computed tomography perfusion. This article compares the receiver operating characteristics curve of computed tomography angiography and dynamic myocardial perfusion to diagnose significant stenosis by invasive coronary angiography.

5.
J Diabetes Complications ; 32(6): 609-615, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29627375

RESUMO

AIMS: To investigate the relationship of type 2 diabetes duration and myocardial blood flow (MBF) assessed by myocardial CT perfusion. MATERIALS AND METHODS: We prospectively included 140 patients with type 2 diabetes who underwent dynamic myocardial CT perfusion exam. MBF of the remote myocardium was calculated using the deconvolution technique and the Voronoi method. The relationships of MBF and diabetic duration, diabetic complications, conventional risk factors, coronary calcium, and coronary stenosis were assessed by logistic regression analysis. RESULTS: A weak but significantly negative relationship was present between diabetes duration and MBF (R2 = 0.05, p < 0.01). The average MBF of patients with a duration of >8 years was 13% lower than that of the remaining patients (1.11 ±â€¯0.35 vs 1.28 ±â€¯0.27 ml min-1 g-1, p < 0.01). Duration of one year was associated with a 6% increased risk for low MBF (<1.18 ml min-1 g-1) (odds ratio 1.06, 95% confidence interval 1.01-1.12, p < 0.05). Calcium score was also a significant factor for low MBF (odds ratio 1.08 (per 100 Agatston units), 95% confidence interval 1.01-1.17, p < 0.05). CONCLUSION: Longer diabetes duration is associated with lower MBF independent of conventional cardiac risk factors or the presence of coronary stenosis.


Assuntos
Circulação Coronária/fisiologia , Estenose Coronária/epidemiologia , Estenose Coronária/etiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Coração/diagnóstico por imagem , Idade de Início , Idoso , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Estenose Coronária/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Angiopatias Diabéticas/diagnóstico , Angiopatias Diabéticas/epidemiologia , Angiopatias Diabéticas/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA