Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
J Hosp Infect ; 147: 188-196, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38373530

RESUMO

INTRODUCTION: A ring trial organized by the Association of Applied Hygiene (VAH) on the bactericidal efficacy of an ethanol-based hand rub was carried out in 17 laboratories according to EN 1500 with the aim of describing the variability of test results and fulfilment of the methodological acceptance criteria. METHOD: As a test product, a hand rub based on 80% ethanol (w/w) was tested in comparison with the reference alcohol (60% iso-propanol, v/v) in a crossover design. After pre-washing and contamination following the norm, hands were treated either with the reference alcohol (2 × 3 mL for 2 × 30 s) or the test product (3 mL in 30 s). Post-decontamination values were determined immediately after the rub-in period. Validated neutralizers were used. The arithmetic means of all individual log10 pre-values, post-values and reduction values were calculated per laboratory. Non-inferiority was assumed when the Hodges-Lehmann 97.5% confidence limit was <0.6 in comparison with the reference. A z-score was calculated to determine the laboratory performance. RESULTS: Two laboratories did not meet the acceptance criteria and were excluded from the analysis. The bactericidal efficacy of the test product was non-inferior to the reference product in four laboratories and not non-inferior in 11 laboratories. The z-score for the Hodges-Lehmann 97.5% confidence limit indicated a satisfactory performance in all laboratories. CONCLUSION: We consider the EN 1500 test method to be robust in terms of the variability of test results. For products of borderline efficacy, the evaluation should be based on more than one test.


Assuntos
Estudos Cross-Over , Etanol , Desinfecção das Mãos , Humanos , Desinfecção das Mãos/métodos , Desinfecção das Mãos/normas , Etanol/farmacologia , Laboratórios/normas , Desinfetantes/farmacologia , Reprodutibilidade dos Testes
3.
J Hosp Infect ; 138: 81-84, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37210037

RESUMO

BACKGROUND: The methods currently used in Europe and North America to evaluate the bactericidal efficacy of hand hygiene products have some limitations (e.g. selection of test organism, method of contamination), and none of the methods allow prediction of actual clinical efficacy. Therefore, the World Health Organization has proposed the development of methods that better reflect typical clinical reality. METHODS: In Experiment 1, two contamination methods (immersion method according to EN 1500 and low-volume method according to ASTM E2755) were tested with the EN 1500 test organism Escherichia coli using 60% v/v iso-propanol. Experiment 2 compared the two contamination methods with Enterococcus faecalis. Experiment 3 compared the two test organisms using the low-volume contamination method. Data within each experiment were compared using the Wilcoxon test for paired samples, and data from all experiments were combined and fit to linear mixed-effects models. RESULTS: Mixed-effects analysis confirmed that both the test organism and the contamination method impacted the pre-values, and all three factors influenced log10 reductions. Higher pre-values resulted in significantly higher log10 reductions, immersion contributed to significantly higher log10 reductions, and E. coli showed significantly lower log10 reductions. CONCLUSION: An efficacy evaluation against E. faecalis with a low-volume contamination method could be considered as an alternative to the EN 1500 standard. This could help to improve the clinical relevance of the test method by including a Gram-positive organism and reducing the soil load, allowing product application closer to reality.


Assuntos
Desinfetantes , Escherichia coli , Humanos , Desinfecção das Mãos/métodos , 2-Propanol , Mãos
4.
J Hosp Infect ; 134: 89-96, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36738992

RESUMO

Regulations for measures to protect against SARS-CoV-2 transmission vary widely around the world, with very strict regulations in Germany where respirators (filtering face piece FFP2 or comparable) are often mandatory. The efficiency of respirators, however, depends essentially on the tight facial fit avoiding the bypass of contaminated air via gaps between mask and wearer's face. The facial fit can be verified in a fit test. The aim of this review was to describe the quantitative fit test results depending on the respirator designs. A literature search revealed 29 suitable studies. Of all respirators with circumferential head straps, three-panel folded dome-shaped respirators showed the best fit (80.8% of 4625 fit tests passed), followed by rigid-dome-shaped respirators (72.4% of 8234 fit tests passed), duckbill-shaped respirators (31.6% of 2120 fit tests passed), and coffee-filter-shaped respirators (30.9% of 3392 fit tests passed). Respirators with ear loops showed very poor tight fit (3.6% of 222 fit tests passed). In four randomized control trials, single-use respirators were not shown to be superior to surgical masks for the prevention of laboratory-confirmed viral respiratory infections, even when adjusted with a fit test. Therefore, we consider the mandatory use of respirators to be disproportionate and not supported by evidence. Further evidence should be generated, in which scenarios respirators might provide an effective benefit as part of occupational health and safety. For situations with confirmed benefits, only high-quality disposable respirators with head straps or respiratory protective equipment of higher protective levels should be used.


Assuntos
COVID-19 , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Humanos , COVID-19/prevenção & controle , SARS-CoV-2 , Desenho de Equipamento , Máscaras , Ventiladores Mecânicos , Exposição Ocupacional/prevenção & controle
5.
J Hosp Infect ; 133: 46-48, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36638889

RESUMO

This study evaluated the bactericidal efficacy of two alternative hand antiseptics, based on sodium hypochlorite or sodium hypochlorite and hypochlorous acid, compared with isopropanol on the hands of volunteers artificially contaminated with Escherichia coli using EN 1500. The reference alcohol was applied according to the norm, and the study formulations were used as in common practice (3 mL for 30 s). The products showed mean log10 reductions of 1.63 and 1.89, both of which were inferior to the reference treatment (4.78). Due to the failure to achieve sufficient bactericidal efficacy within 30 s, sodium hypochlorite (0.05-0.06%) should not be considered for hand disinfection.


Assuntos
Desinfetantes , Higienizadores de Mão , Humanos , Desinfecção das Mãos , Hipoclorito de Sódio , Etanol , Higiene , Mãos , Desinfecção
6.
J Hosp Infect ; 130: 34-43, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36179793

RESUMO

BACKGROUND: Most COVID-19 outbreaks in nursing homes are explained by transmission of SARS-CoV-2 from nurses or visitors. METHODS AND RESULTS: We describe an outbreak with 64 of the 67 residents identified as COVID-19 cases within two weeks (34 in nursing block 1, 30 in nursing block 2), at least 32 of them had relevant symptoms of COVID-19. Thirteen of the residents' deaths were associated with COVID-19. In addition, 27 of approximately 60 staff members were identified as COVID-19 cases, 23 of them had relevant symptoms. In none of the samples from residents or staff was a mutation of SARS-CoV-2 detected. Quarantine of the residents was already in force at the beginning of the outbreak. A common source among the staff was considered to be unlikely because the two nursing home blocks had no staff rotation and the staff had to wear FFP2 masks during contact with residents. Three months after the outbreak the RNA of SARS-CoV-2 was detected on 14 of 39 sampled indoor surfaces of the air ventilation system with Ct values between 34.9 and 41.9, but only at the air supply in the corridor (11 of 24 samples) and the air overflow in the door between the corridor and the residents' rooms (three of 11 samples) but not at the air exhaust in the residents' bathrooms. CONCLUSIONS: The air ventilation system and an inversion weather situation three days before the first confirmed case may have enhanced viral spread inside the nursing home assuming that a common source with a high viral load had existed at the time of outbreak.


Assuntos
COVID-19 , Substâncias Explosivas , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Casas de Saúde , Surtos de Doenças
8.
J Hosp Infect ; 127: 101-110, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35777702

RESUMO

The number of human monkeypox virus infections is increasing in many countries. The typical mode of transmission is by direct contact. As orthopoxviruses may stay infectious on inanimate surfaces under laboratory conditions for up to 42 days, disinfection may be relevant in the surroundings of confirmed cases. The aim of this review was to evaluate published data on the antiviral efficacy of biocidal agents and disinfectants against the monkeypox virus and other orthopoxviruses. A Medline search was carried out on 5th June 2022. The terms 'monkeypox virus', 'poxvirus' and 'orthopoxvirus' were used in combination with 'disinfection'. Publications were included and results were extracted where they provided original data on any orthopoxvirus regarding its inactivation by disinfectants. Vaccinia viruses could be inactivated by at least 4 log10 in suspension tests and on artificially contaminated surfaces by 70% ethanol (≤1 min), 0.2% peracetic acid (≤10 min) and 1-10% of a probiotic cleaner (1 h), mostly shown with different types of organic load. Hydrogen peroxide (14.4%) and iodine (0.04-1%) were effective in suspension tests, sodium hypochlorite (0.25-2.5%; 1 min), 2% glutaraldehyde (10 min) and 0.55% orthophthalaldehyde (5 min) were effective on artificially contaminated surfaces. Copper (99.9%) was equally effective against vaccinia virus and monkeypox virus in 3 min. Disinfectants with efficacy data obtained in suspension tests and under practical conditions with different types of organic load resembling compounds of the blood, the respiratory tract and skin lesions are preferred for the inactivation of the monkeypox virus.


Assuntos
Desinfetantes , Mpox , Orthopoxvirus , Vírus , Animais , Desinfetantes/farmacologia , Desinfecção/métodos , Humanos , Mpox/prevenção & controle , Monkeypox virus
10.
J Hosp Infect ; 122: 140-147, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35077809

RESUMO

BACKGROUND: A sporicidal surface disinfection is recommended both for the outbreak and the endemic setting but a comparative evaluation on the efficacy of 'sporicidal' surface disinfectants using suspension tests and 4-field tests has not been performed. AIM: To determine the efficacy of five 'sporicidal' surface disinfectants (three ready-to-use wipes (A, B, E), two concentrates (C, D) based on peroxides or aldehydes against C. difficile spores. METHODS: The efficacy was determined under clean conditions using a suspension test and the 4-field test. Each test was performed in duplicate in two separate laboratories. Wipes were wrung to collect the solution for the suspension tests. RESULTS: Product A (peracetic acid; 5 min), product C (peracetic acid; 2% solution in 15 min or 1% solution in 30 min) and product D (peracetic acid; only 2% solution in 15 min) were effective with at least a 4 log10-reduction of C. difficile spores in suspension and on surfaces. Product B (hydrogen peroxide) was not effective in suspension (0.9 log10 after 15 min; 3.2 log10 after 1 h) and on surfaces (2.8 log10 after 15 and 60 min). Product E based on glutaraldehyde, (ethylendioxy)dimethanol and DDAC demonstrated 0.9 log10 after 4 h in suspension and 4.5 log10 after 4 h on surfaces. CONCLUSIONS: Not all surface disinfectants with a sporicidal claim were effective against C. difficile spores in standardized suspension tests and in the 4-field test. In clinical practice preference should be given to products that reliably pass the efficacy criteria of both types of tests.


Assuntos
Clostridioides difficile , Desinfetantes , Clostridioides , Desinfetantes/farmacologia , Humanos , Ácido Peracético/farmacologia , Esporos Bacterianos
11.
J Hosp Infect ; 117: 17-22, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34419521

RESUMO

BACKGROUND: In the current era, the importance of proper hand hygiene to reduce the transmission of infectious diseases has become difficult to debate. Yet, compliance rates remain low and are affected by many factors, amongst which is user acceptability of hand hygiene products. AIM: The present study aimed at investigating drivers of preference towards different hand hygiene formulations. METHODS: Three different formulations (liquid, foam and gel) of the same brand were randomly and blindly evaluated by 54 participants based on the WHO Protocol for Evaluation of Tolerability and Acceptability of Alcohol-based Handrubs. RESULTS: The majority (76%) of respondents indicated that the product formulation impacted their level of compliance with hand hygiene protocols. The preferred formulation was liquid, with 50% of participants ranking it as first choice. General product satisfaction, the product texture, the drying speed and the ease of application, were the statistically significant drivers for participants to rank a formulation as their first choice vs not ranking it as their first choice. CONCLUSIONS: When designing alcohol formulations and implementing hand hygiene protocols, understanding drivers of preference for formulations may enhance product user acceptability and therefore compliance with hand hygiene.


Assuntos
Desinfecção das Mãos , Higiene das Mãos , Dessecação , Etanol , Mãos , Humanos
13.
J Hosp Infect ; 111: 47-49, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33757811

RESUMO

We evaluated the bactericidal efficacy of two modified WHO-recommended alcohol-based hand rubs (3 mL) after a 15-s rubbing period using two different rub-in techniques (three vs six steps). The formulation based on 80% w/w ethanol and 0.5% v/v glycerol (modified WHO I) showed a mean log10-reduction of 3.63 ± 0.87 (six steps) and 3.80 ± 0.71 (three steps) which was inferior to the reference treatment (4.27 ± 0.98; six steps). The efficacy of the formulation based on 75% w/w isopropanol and 0.5% v/v glycerol (modified WHO II) was not inferior to the reference treatment for either rub-in technique.


Assuntos
2-Propanol , Anti-Infecciosos Locais , Etanol , Desinfecção das Mãos , Higienizadores de Mão , Mãos , Humanos , Organização Mundial da Saúde
15.
J Hosp Infect ; 106(4): 678-697, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32956786

RESUMO

During the current SARS-CoV-2 pandemic new studies are emerging daily providing novel information about sources, transmission risks and possible prevention measures. In this review, we aimed to comprehensively summarize the current evidence on possible sources for SARS-CoV-2, including evaluation of transmission risks and effectiveness of applied prevention measures. Next to symptomatic patients, asymptomatic or pre-symptomatic carriers are a possible source with respiratory secretions as the most likely cause for viral transmission. Air and inanimate surfaces may be sources; however, viral RNA has been inconsistently detected. Similarly, even though SARS-CoV-2 RNA has been detected on or in personal protective equipment (PPE), blood, urine, eyes, the gastrointestinal tract and pets, these sources are currently thought to play a negligible role for transmission. Finally, various prevention measures such as handwashing, hand disinfection, face masks, gloves, surface disinfection or physical distancing for the healthcare setting and in public are analysed for their expected protective effect.


Assuntos
COVID-19/diagnóstico , Portador Sadio/transmissão , Transmissão de Doença Infecciosa/prevenção & controle , SARS-CoV-2/genética , COVID-19/epidemiologia , COVID-19/transmissão , COVID-19/virologia , Portador Sadio/virologia , Luvas Protetoras/virologia , Desinfecção das Mãos/métodos , Instalações de Saúde/normas , Humanos , Máscaras/virologia , Pandemias/prevenção & controle , Equipamento de Proteção Individual/virologia
16.
J Hosp Infect ; 106(2): 264-270, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32800826

RESUMO

The World Health Organization (WHO) hand-rub formulations have been in use around the world for at least the past 10 years. The advent of coronavirus disease 2019 (COVID-19) has further enhanced their use. We reviewed published efficacy data for the original and modified formulations. Only efficacy data according to the European Norms (EN) were found. The bactericidal efficacy of the original formulations was, under practical conditions, partly insufficient (EN 1500, only effective in 60 s; EN 12791, efficacy too low in 5 min). The first modification with higher alcohol concentrations improves their efficacy as hygienic hand rub (effective in 30 s). The second (0.725% glycerol) and third (0.5% glycerol) modification improves their efficacy for surgical hand preparation (effective in 5 and 3 min). The original and second modified formulations were tested and demonstrate activity against enveloped viruses including severe acute resiratory syndrome coronavirus 2 (SARS-CoV-2) in 30 s. The ethanol-based formulation is also active against some non-enveloped test viruses in 60 s (suspension tests, EN 14476). In-vivo data on the formulations would provide a more reliable result on the virucidal efficacy on contaminated hands but are currently not available. Nevertheless, the most recent modifications should be adopted for use in healthcare.


Assuntos
2-Propanol/normas , Anti-Infecciosos Locais/normas , Infecções por Coronavirus/prevenção & controle , Desinfetantes/normas , Guias como Assunto , Desinfecção das Mãos/normas , Controle de Infecções/normas , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Betacoronavirus , COVID-19 , Humanos , SARS-CoV-2 , Organização Mundial da Saúde
18.
J Hosp Infect ; 105(3): 424-427, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32360355

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has caused a huge demand for alcohol-based hand rubs, medical gloves, face masks, and gowns in healthcare and from the public. More and more hospitals face a serious shortage of these articles. We propose a risk-adapted approach to ensure adequate patient and healthcare worker safety for as long as possible.


Assuntos
Infecções por Coronavirus/prevenção & controle , Luvas Protetoras/provisão & distribuição , Higienizadores de Mão/provisão & distribuição , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Máscaras/provisão & distribuição , Pandemias/prevenção & controle , Segurança do Paciente , Pneumonia Viral/prevenção & controle , Roupa de Proteção/provisão & distribuição , COVID-19 , Humanos , Equipamento de Proteção Individual , Comportamento de Redução do Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA