Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 35(8): e5121, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33760252

RESUMO

A novel method was developed for the simultaneous estimation of the doravirine, lamivudine, and tenofovir disoproxil fumarate in the pharmaceutical dosage form. The chromatogram was run through an Ascentis C18 column (150 × 4.6 mm, 2.7 µm), with the mobile phase consisting of a phosphate buffer and acetonitrile in the ratio of 50:50 (v/v). The mobile phase was pumped through the column at a flow rate of 1 mL/min. The column temperature was maintained at 30°C. The optimized wavelength for doravirine, lamivudine, and tenofovir disoproxil fumarate was 230.0 nm. The retention times for doravirine, lamivudine, and tenofovir disoproxil were 2.222, 2.764, and 3.403 min, respectively; the relative standard deviation (%) values of method precision for doravirine, lamivudine, and tenofovir disoproxil were 0.6, 0.6, and 0.1, respectively. The % recovery was 100.20%, 100.15%, and 100.36% for doravirine, lamivudine, and tenofovir disoproxil fumarate, respectively. The limit of detection and limit of quantification values were obtained from regression equations of doravirine, lamivudine, and tenofovir disoproxil fumarate, and were 0.24 and 0.73 ppm, 0.53 and 1.60 ppm, and 0.47 and 1.43 ppm, respectively. The regression equations of doravirine, lamivudine, and tenofovir disoproxil fumarate were y = 17,541x + 117,303, y = 15,555x + 10,791, and y = 15,250x + 31,663, respectively. The method developed was accurate, simple, precise, sensitive, and economical. Hence, it could be adopted for regular quality control for estimation of doravirine, lamivudine, and tenofovir disoproxil fumarate in pharmaceutical industries.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Lamivudina/análise , Piridonas/análise , Tenofovir/análise , Triazóis/análise , Estabilidade de Medicamentos , Lamivudina/química , Limite de Detecção , Modelos Lineares , Piridonas/química , Reprodutibilidade dos Testes , Comprimidos , Tenofovir/química , Triazóis/química
2.
Drug Test Anal ; 10(1): 212-221, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28421713

RESUMO

Seven unknown impurities in Repaglinide bulk drug batches at below 0.1% (ranging from 0.05 to 0.10%) were detected by an ultra-performance liquid chromatographic (UPLC) method. These impurities were isolated from the crude sample of Repaglinide using preparative high performance liquid chromatography (prep-HPLC). Based on liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI/MS) study, the chemical structures of seven new impurities (8, 9, 10, 11, 13, 14, and 16) were presumed and characterized as 4-(cyanomethyl)-2-ethoxybenzoic acid (8), 4-(cyanomethyl)-2-ethoxy-N-(3-methyl-1-(2-(piperidin-1-yl)phenyl)butyl)benzamide (9), 4-(2-amino-2-oxoethyl)-2-ethoxy-N-(3-methyl-1-(2-(piperidin-1-yl)phenyl)butyl) benzamide (10) and 2-(3-ethoxy-4-((3-methyl-1-(2-(piperidin-1-yl)phenyl)butyl) carbamoyl) phenyl) acetic acid (11) and 4-(cyanomethyl)-N-cyclohexyl-2-ethoxybenzamide (13), 2-(4-(cyclohexylcarbamoyl)-3-ethoxyphenyl) acetic acid (14) and N-cyclohexyl-4-(2-(cyclohexylamino)-2-oxoethyl)-2-ethoxybenzamide (16). The complete spectral analysis, proton nuclear magnetic resonance (1 H NMR), 13 C NMR, MS, and infrared (IR) confirmed the proposed chemical structures of impurities. Identification, structural characterization, formation, and their synthesis was first reported in this study. The impurity 11 was crystallized and structure was solved by single crystal X-ray diffraction. Copyright © 2017 John Wiley & Sons, Ltd.


Assuntos
Carbamatos/análise , Carbamatos/síntese química , Contaminação de Medicamentos , Hipoglicemiantes/análise , Hipoglicemiantes/síntese química , Piperidinas/análise , Piperidinas/síntese química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Carbamatos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Hipoglicemiantes/isolamento & purificação , Piperidinas/isolamento & purificação , Espectrometria de Massas por Ionização por Electrospray/normas , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/normas , Espectrometria de Massas em Tandem/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA