Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
World J Pediatr Congenit Heart Surg ; 15(4): 453-458, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38454615

RESUMO

Background: Excellent outcomes of right ventricle to pulmonary artery conduits with polytetrafluoroethylene (PTFE) valves have been reported. The purpose of this study was to analyze the short-term results of our handmade PTFE bicuspid valved conduit (VC) for right ventricular outflow tract reconstruction. Methods: Between September 2019 and May 2023, bicuspid PTFE-VC was implanted in 17 patients at a median age of 2.5 years (range, 3 months to 13.6 years). The PTFE-VC was fashioned from a commercially available PTFE tube graft (14 mm in three patients, 16 mm in three patients, 18 mm in one patient, 20 mm in three patients, and 22 mm in seven patients) and 0.1 mm thick PTFE membrane for the leaflet material. Valve function was assessed by echocardiogram after the implantation. The conduit reoperation and the conduit dysfunction were analyzed. There were no early deaths, but there was one late death. Results: There were no postoperative in-hospital deaths. Follow-up echocardiograms were available for 14 of 17 patients. The median follow-up was 21 months (range, 7-49 months). Conduit stenosis was none or trivial in 11 patients while it was mild in two and moderate in one patient and severe in 0 patients. Conduit insufficiency was mild or trivial in all 14 patients. By the end of the study period, freedom from reoperation/reintervention was 100%. There were no episodes of aneurysmal dilatation of the conduit or endocarditis. Conclusions: Handmade bicuspid PTFE VC shows good short-term outcome, with no significant valve dysfunction and no reintervention. A longer follow-up is necessary to evaluate the long-term advantages of using the handmade bicuspid PTFE VC.


Assuntos
Politetrafluoretileno , Desenho de Prótese , Humanos , Pré-Escolar , Masculino , Feminino , Criança , Lactente , Adolescente , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Obstrução do Fluxo Ventricular Externo/cirurgia , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Ecocardiografia , Cardiopatias Congênitas/cirurgia
2.
World J Pediatr Congenit Heart Surg ; 14(1): 80-83, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35957595

RESUMO

Different surgical techniques have been described for the primary repair of anomalous left coronary artery arising from the pulmonary artery (ALCAPA); however, very few techniques are described for management of coronary artery occlusion following ALCAPA repair. We present a case of a 7-year-old girl with left main coronary atresia status-post left coronary button transfer for ALCAPA in infancy. She underwent redo-sternotomy and left subclavian artery-to-left main coronary artery bypass plus mitral valve repair and had an uneventful postoperative course.


Assuntos
Síndrome de Bland-White-Garland , Procedimentos Cirúrgicos Cardíacos , Anomalias dos Vasos Coronários , Feminino , Humanos , Lactente , Criança , Síndrome de Bland-White-Garland/cirurgia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Artéria Subclávia/cirurgia , Ponte de Artéria Coronária/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Artéria Pulmonar/cirurgia
3.
World J Pediatr Congenit Heart Surg ; 13(4): 495-498, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35757954

RESUMO

Aortic regurgitation after transcatheter device closure of a perimembranous ventricular septal defect is a known complication. We present the case of an 11-year-old boy with severe aortic valve regurgitation due to cusp perforation complicating previous device closure of a ventricular septal defect. The patient underwent successful aortic valve repair (neo-cusp reconstruction technique) by replacement of a cusp and shaving off of a rim of the device 5 years after device closure.


Assuntos
Insuficiência da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Comunicação Interventricular/complicações , Comunicação Interventricular/cirurgia , Humanos , Masculino , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
4.
Ann Pediatr Cardiol ; 15(3): 238-243, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36589646

RESUMO

Background: Various operative strategies are described for the Fontan procedure. In this study, we describe our short-term results and technique of Fontan procedure on cardiopulmonary bypass (CPB) and deep hypothermic circulatory arrest (DHCA). Methods: This was a retrospective study of 32 patients, median age of 6 years (4-19 years) and median weight of 20 kg (13-51 kg), who underwent Fontan procedure on CPB and DHCA from July 2016 to July 2021. Results: The median CPB time was 125 min (77-186 min), the median DHCA time was 42 min (27-50 min), and the median Fontan pressure was 14 mmHg (10-18 mmHg). The median time to extubation was 4 h (1-20 h), the duration of chest tube drainage was 8 days (5-24 days), and the median intensive care unit stay was 4 days (3-8 days). The presence of heterotaxy was associated with longer duration of pleural drainage (P = 0.01). There was no operative mortality and no major adverse events such as seizures, gross neurological deficits, or arrhythmias in the postoperative period. Conclusions: Fontan procedure can be safely performed on CPB and DHCA with good operative results. This operative strategy may be used in special circumstances like in patients with situs and systemic venous anomalies and those requiring repair of a complex intracardiac defect. Long-term follow-up will be required to evaluate if this strategy has any impact on the neurodevelopmental outcome and the long-term sequelae of Fontan.

5.
World J Pediatr Congenit Heart Surg ; 11(1): 97-100, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31835987

RESUMO

PURPOSE: Numerous attempts have been made to extend the boundaries of arterial switch operation (ASO) in children presenting late with transposition of great arteries with intact ventricular septum (TGA/IVS) and regressed left ventricle (rLV). Many children tolerate the delayed ASO uneventfully, whereas others need mechanical circulatory support (MCS) to sustain the systemic circulation while the left ventricle undergoes retraining. DESCRIPTION: In this article, we describe six consecutive children with TGA/IVS and rLV who underwent primary ASO. RESULTS: Three were managed medically, while three required MCS in the form of Centrimag left ventricular assist device (LVAD). All patients survived the operation and were discharged home in a stable condition. CONCLUSIONS: Primary ASO can be safely performed in children with TGA/IVS and rLV, provided the center has MCS options. Supporting the rLV with LVAD is feasible and can be achieved safely.


Assuntos
Ventrículos do Coração/cirurgia , Transposição dos Grandes Vasos/cirurgia , Transposição das Grandes Artérias , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Coração Auxiliar , Humanos , Lactente , Masculino , Estudos Retrospectivos , Transposição dos Grandes Vasos/diagnóstico por imagem , Resultado do Tratamento
6.
World J Pediatr Congenit Heart Surg ; 10(2): 223-227, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30841826

RESUMO

The preferred approach for patients with D-transposition of the great arteries with an intact ventricular septum (DTGA/IVS) is the arterial switch operation (ASO). In those patients presenting late, with regressed left ventricle (LV), successful LV preparation is of paramount importance to achieve this goal. We present a toddler with DTGA/IVS who underwent ASO followed by successful left ventricular retraining with postoperative left ventricular assist device support with CentriMag centrifugal pump.


Assuntos
Transposição das Grandes Artérias , Coração Auxiliar , Cuidados Pós-Operatórios , Transposição dos Grandes Vasos/cirurgia , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA