Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Light Sci Appl ; 12(1): 44, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36792590

RESUMO

High-speed and high-resolution imaging of surface profiles is critical for the investigation of various structures and mechanical dynamics of micro- and nano-scale devices. In particular, recent emergence of various nonlinear, transient and complex mechanical dynamics, such as anharmonic vibrations in mechanical resonators, has necessitated real-time surface deformation imaging with higher axial and lateral resolutions, speed, and dynamic range. However, real-time capturing of fast and complex mechanical dynamics has been challenging, and direct time-domain imaging of displacements and mechanical motions has been a missing element in studying full-field structural and dynamic behaviours. Here, by exploiting the electro-optic sampling with a frequency comb, we demonstrate a line-scan time-of-flight (TOF) camera that can simultaneously measure the TOF changes of more than 1000 spatial coordinates with hundreds megapixels/s pixel-rate and sub-nanometre axial resolution over several millimetres field-of-view. This unique combination of performances enables fast and precise imaging of both complex structures and dynamics in three-dimensional devices and mechanical resonators.

3.
Rev Sci Instrum ; 90(4): 045001, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31043054

RESUMO

A high-resolution angle sensor which uses a double slit (DS) is proposed. By analyzing the positions of intensity peaks in the DS interference pattern, the incident angle of a collimated beam entering the DS is measured. The DS was designed to generate the multiple-order interference pattern with almost even modulation amplitude so that not only the central peak but also multiple side peaks could be used for the measurement. By averaging the incident angle values obtained from each peak position, the angle sensor achieved higher resolution and a smaller periodic nonlinearity error. The performance of the DS angle sensor was tested by comparison with a commercial autocollimator. The Allan deviation of the readout of the angle sensor was 0.0002 in. with the averaging time of 4 s, and the periodic nonlinearity error was evaluated to be less than 0.01 in.

4.
Rev Sci Instrum ; 89(4): 046105, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29716378

RESUMO

This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.

5.
Opt Lett ; 43(7): 1447-1450, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29601001

RESUMO

We propose and demonstrate a new method which employs time-of-flight detection of femtosecond laser pulses for precise height measurement of large steps. By using time-of-flight detection with fiber-loop optical-microwave phase detectors, precise measurement of large step height is realized. The proposed method shows uncertainties of 15 nm and 6.5 nm at sampling periods of 40 ms and 800 ms, respectively. This method employs only one free-running femtosecond mode-locked laser and requires no scanning of laser repetition rate, making it easier to operate. Precise measurements of 6 µm and 0.5 mm step heights have been demonstrated, which show good functionality of this method for measurement of step heights.

6.
Rev Sci Instrum ; 88(5): 055108, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28571473

RESUMO

An interferometric system is proposed for measuring the thickness of parallel glass plates by analyzing Haidinger fringes. Although a conventional Haidinger interferometer can measure thickness without 2π ambiguity using positions of peak and valley points in the interferogram, measurement accuracy is directly affected by the number of these points involved in the calculation. The proposed method obtains phase values over the entire interferogram by analyzing the quadrature Haidinger fringes generated by a current modulated laser diode. Therefore, it can achieve high speed measurement and nanometric resolution without mechanical rotation and thickness limitation of specimens. In the experiments, the standard deviation of repeated thickness measurement was evaluated as less than 0.3 nm, and the measured thickness profile of the proposed system agreed with that of a conventional thickness interferometer within ±15 nm. We also discussed the required accuracy of refractive index of specimens to implement the proposed method successfully and presented an exemplary measurement result of a multi-layer coated sample having a discontinuous thickness profile.

7.
Appl Opt ; 53(20): 4604-10, 2014 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-25090083

RESUMO

A thickness measurement system is proposed for in-line inspection of thickness variation of flat glass panels. Multi-reflection on the surfaces of glass panel generates an interference signal whose phase is proportional to the thickness of the glass panel. For accurate and stable calculation of the phase value, we obtain quadrature interference signals using a current modulation technique. The proposed system can measure a thickness profile with high speed and nanometric resolution, and obtain higher accuracy through real-time nonlinear error compensation. The thickness profile, measured by a transmissive-type experimental setup, coincided with a comparative result obtained using a contact-type thickness measurement system within the range of ±40 nm. The standard deviations of the measured thickness profiles and their waviness components were less than 3 nm with a scanning speed of 300 mm/s.

8.
Opt Express ; 22(6): 6486-94, 2014 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-24663997

RESUMO

A technique which can measure thickness variation of a moving glass plate in real-time with nanometric resolution is proposed. The technique is based on the double-slit interference of light. Owing to the nature of differential measurement scheme, the measurement system is immune to harsh environmental condition of a production line, and the measurement results are not affected by the swaying motion of the panel. With the preliminary experimental setup with scanning speed of 100 mm/s, the measurement repeatability was 3 nm for the waviness component of the thickness profile, filtered with a Gaussian filter with cutoff wavelength of 8 mm.

9.
Rev Sci Instrum ; 84(5): 056102, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742600

RESUMO

This Note presents a new absolute planar position measurement method using a two-dimensional phase-encoded binary grating and a sub-division process where nonlinearity error is compensated inherently. Two orthogonally accumulated intensity profiles of the image of the binary grating are analyzed separately to obtain the absolute position values in each axis. The nonlinearity error caused by the non-ideal sinusoidal signals in the intensity profile is compensated by modifying the configuration of the absolute position binary code and shift-averaging the intensity profile. Using an experimental setup, we measured a circular trajectory of 100 nm radius, and compared the measurement result with that of a laser interferometer. Applying the proposed compensation method, the nonlinearity error was reduced to less than 15 nm.

10.
Rev Sci Instrum ; 83(11): 115115, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206106

RESUMO

We present a new absolute position measurement method using a single track binary code where an absolute position code is encoded by changing the phase of one binary state representation. It can be decoded efficiently using structural property of the binary code, and its sub-division is possible by detecting the relative positions of the binary state representation used for the absolute position encoding. Therefore, the absolute position encoding does not interfere with the sub-division process and so any pseudo-random sequence can be used as the absolute position code. Because the proposed method does not require additional sensing part for the sub-division, it can be realized with a simple configuration and efficient data processing. To verify and evaluate the proposed method, an absolute position measurement system was setup using a binary code scale, a microscopic imaging system, and a CCD camera. In the comparison results with a laser interferometer, the measurement system shows the resolution of less than 50 nm and the nonlinearity error of less than ±60 nm after compensation.

11.
Opt Express ; 20(5): 5011-6, 2012 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-22418305

RESUMO

We have proposed and demonstrated a novel method to measure depths of through silicon vias (TSVs) at high speed. TSVs are fine and deep holes fabricated in silicon wafers for 3D semiconductors; they are used for electrical connections between vertically stacked wafers. Because the high-aspect ratio hole of the TSV makes it difficult for light to reach the bottom surface, conventional optical methods using visible lights cannot determine the depth value. By adopting an optical comb of a femtosecond pulse laser in the infra-red range as a light source, the depths of TSVs having aspect ratio of about 7 were measured. This measurement was done at high speed based on spectral resolved interferometry. The proposed method is expected to be an alternative method for depth inspection of TSVs.


Assuntos
Interferometria/instrumentação , Lasers , Embalagem de Produtos/instrumentação , Refratometria/instrumentação , Semicondutores , Desenho de Equipamento , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos
12.
Rev Sci Instrum ; 82(11): 116108, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22129024

RESUMO

We present an angle generator with high resolution and accuracy, which uses multiple ultrasonic motors and a self-calibratable encoder. A cylindrical air bearing guides a rotational motion, and the ultrasonic motors achieve high resolution over the full circle range with a simple configuration. The self-calibratable encoder can compensate the scale error of a divided circle (signal period: 20") effectively by applying the equal-division-averaged method. The angle generator configures a position feedback control loop using the readout of the encoder. By combining the ac and dc operation mode, the angle generator produced stepwise angular motion with 0.005" resolution. We also evaluated the performance of the angle generator using a precision angle encoder and an autocollimator. The expanded uncertainty (k = 2) in the angle generation was estimated less than 0.03", which included the calibrated scale error and the nonlinearity error.

13.
Rev Sci Instrum ; 82(8): 086111, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21895289

RESUMO

We present a high speed optical profiler (HSOP) using frequency-scanning lasers for three-dimensional profile measurements of microscopic structures. To improve upon previous techniques for implementing the HSOP, we developed frequency-scanning lasers and a compact microscopic interferometer. The controller of the HSOP was also modified to generate proper phase-shifting steps. For measurements of step height specimens, the HSOP showed results comparable with a commercial optical profiler, even with much higher measurement speeds (up to 30 Hz). The typical repeatability of step height measurement was less than 1 nm. We also present measurements of microscopic structures to verify the HSOP's ability to perform high speed inline inspection for the semiconductor and flat-panel display industries.

14.
Appl Opt ; 50(11): 1541-7, 2011 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-21478926

RESUMO

High-speed two-wavelength phase-shifting interferometry is presented. The technique is aimed at high-speed in-line inspection of spacers in liquid crystal display panels or wafer bumps where the measuring range is well determined and high-speed measurements are essential. With our test setup, the measuring range is extended to 10 µm by using two injection locked frequency scanning lasers that offer fast and equidistant phase shifting of interference fringes. A technique to determine the unwrapped phase map in a frequency scanning phase-shifting interferometry without the ordinary phase-unwrapping process is proposed.

15.
Opt Express ; 18(23): 23517-22, 2010 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-21164694

RESUMO

We propose and demonstrate a novel method to enhance the visibility of an optical interferometer when measuring low reflective materials. Because of scattering from a rough surface or its own low reflectivity, the visibility of the obtained interference signal is seriously deteriorated. By amplifying the weak light coming from the sample based on an injection-locking technique, the visibility can be enhanced. As a feasibility test, even with a sample having a reflectivity of 0.6%, we obtained almost the same visibility as a metal coated mirror. The suggested visibility enhanced interferometer can be widely used for measuring low reflective materials.

16.
Opt Express ; 18(17): 18339-46, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-20721226

RESUMO

We have proposed and demonstrated a novel method that can determine both the geometrical thickness and refractive index of a silicon wafer at the same time using an optical comb. The geometrical thickness and refractive index of a silicon wafer was determined from the optical thickness using phase information obtained in the spectral domain. In a feasibility test, the geometrical thickness and refractive index of a wafer were measured to be 334.85 microm and 3.50, respectively. The measurement uncertainty for the geometrical thickness was evaluated as 0.95 microm (k = 1) using a preliminary setup.


Assuntos
Interferometria/instrumentação , Lasers , Refratometria/instrumentação , Silício/química , Espectrofotometria/instrumentação , Raios Infravermelhos , Interferometria/métodos , Modelos Teóricos , Dispositivos Ópticos , Refratometria/métodos , Espectrofotometria/métodos
17.
Opt Express ; 17(23): 21042-9, 2009 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-19997342

RESUMO

An interferometer having fourteen times higher resolution than a conventional single-pass interferometer has been developed by making multiple-pass optical path. To embody the multiple-pass optical configuration, a two-dimensional corner cube array block was designed, and its symmetric structure minimized the measurement error. The effect from the alignment error and the imperfection of corner cube is calculated as picometer level. An experiment proves that the suggested interferometer has about 45 nm of optical resolution and its nonlinearity is about 0.5 nm in peak-to-valley.


Assuntos
Interferometria/instrumentação , Óptica e Fotônica , Desenho de Equipamento , Interferometria/métodos , Lasers , Luz , Dispositivos Ópticos , Refratometria/instrumentação , Refratometria/métodos , Reprodutibilidade dos Testes , Software
18.
Opt Express ; 17(3): 1442-6, 2009 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-19188972

RESUMO

We present a high speed phase shifting interferometer which utilizes the self injection locking of a frequency tunable laser diode. By using a confocal Fabry-Perot cavity made of ultra low expansion glass, and linearly modulating the laser diode current, the laser frequency could be injection locked to the resonant modes of the Fabry-Perot cavity consecutively. It provided equal phase steps to the interferograms which are ideal to be analyzed by the Carré algorithm. The phase step error was evaluated to be about 3 MHz which corresponds to 0.2 nm in length measurement. With this technique, profile measurements are insensitive to external vibration since four 640x480 pixels images can be acquired within 4 ms. Difference of two profile measurements, each made with and without vibration isolation, respectively, was evaluated to be 0.5 nm (rms).

19.
Opt Express ; 17(25): 23299-308, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-20052256

RESUMO

This study presents an analysis of the nonlinearity resulting from polarization crosstalk at a polarizing beam splitter (PBS) and a wave plate (WP) in a homodyne interferometer. From a theoretical approach, a new compensation method involving a realignment of the axes of WPs to some specific angles according to the characteristics of the PBS is introduced. This method suppresses the nonlinearity in a homodyne interferometer to 0.36 nm, which would be 3.75 nm with conventional alignment methods of WPs.


Assuntos
Algoritmos , Artefatos , Interferometria/métodos , Modelos Teóricos , Simulação por Computador , Dinâmica não Linear
20.
Opt Express ; 15(24): 15759-66, 2007 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-19550860

RESUMO

We report on a novel compact interferometery system for measuring parasitic motions of a precision stage. It is a combination of a Michelson interferometer with an auto-collimator, of which full physical dimension is mere 70 mm x80 mm x35 mm (WxLxH) including optical components, photo-detectors, and electronic circuits. Since the beams, which measure displacement and angle, can be directed at the same position on the moving mirror, the system is applicable for testing small nano-stages where commercial interferometers are not able to be used. And thus, errors from nano-scale deformation of the moving mirror can be minimized. We find that the residual errors of linear and angular motion measurements are 2.5 nm in peak-to-peak and 0.2'', respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA