Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Mult Scler Relat Disord ; 82: 105394, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38141562

RESUMO

INTRODUCTION: Multiple Sclerosis causes gait alteration, even in the early stages of the disease. Traditional methods to quantify gait impairment, such as performance-based measures, lab-based motion analyses, and self-report, have limited ecological relevance. The Mon4t® app is a digital tool that uses sensors embedded in standard smartphones to measure various gait parameters. OBJECTIVES: To evaluate the use of Mon4t® technology in monitoring MS patients. METHODS: 100 MS patients and age-matched healthy controls were evaluated using both a human rater and the Mon4t Clinic™ app. Three motor tasks were performed: 3m Timed up and go test (TUG), 10m TUG, and tandem walk. The digital markers were used to compare MS vs. HC, MS with EDSS=0 vs. HC, and MS with EDSS=0 vs. MS with EDSS>0. Within the MS EDSS>0 group, correlations between digital gait markers and the EDSS score were calculated. RESULTS: Significant differences were found between MS patients and HC in multiple gait parameters. When comparing MS patients with minimal disability (EDSS=0) and HC: On the 3m TUG task, MS patients took longer to complete the task (mean difference 0.167seconds, p =0.034), took more steps (mean difference 1.32 steps, p =0.003), and had a weaker ML step-to-step correlation (mean difference 0.1, p = 0.001). The combination of features from the three motor tasks allowed distinguishing a nondisabled MS patient from a HC with high confidence (AUC of 85.65 on the ROC). When comparing MS patients with minimal disability (EDSS=0) to those with higher disability (EDSS>0): On the tandem walk task, patients with EDSS>0 took significantly longer to complete 10 steps than those with EDSS=0 (mean difference 4.63 seconds, p < 0.001), showed greater ML sway (mean difference 0.2, p < 0.001), and had larger angular velocity in the SI axis on average (mean difference 2.31 degrees/sec, p = 0.01). A classification model achieved 81.79 ROC AUC. In the subgroup of patients with EDSS>0, gait features significantly correlated with EDSS score in all three tasks. CONCLUSION: The findings demonstrate the potential of digital gait assessment to augment traditional disease monitoring and support clinical decision making. The Mon4t® app provides a convenient and ecologically relevant tool for monitoring MS patients and detecting early changes in gait impairment.


Assuntos
Esclerose Múltipla , Humanos , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico , Smartphone , Equilíbrio Postural , Avaliação da Deficiência , Estudos de Tempo e Movimento , Marcha
2.
Front Neurol ; 11: 567413, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33117262

RESUMO

Objective: To evaluate the feasibility of a smartphone remote patient monitoring approach in a real-life Parkinson's disease (PD) cohort during the Italian COVID-19 lockdown. Methods: Fifty-four non-demented PD patients who were supposed to attend the outpatient March clinic were recruited for a prospective study. All patients had a known UPDRS-III and a modified Hoehn and Yahr (H&Y) score and were provided with a smartphone application capable of providing indicators of gait, tapping, tremor, memory and executive functions. Different questionnaires exploring non-motor symptoms and quality of life were administered through phone-calls. Patients were asked to run the app at least twice per week (i.e., full compliance). Subjects were phone-checked weekly throughout a 3-week period for compliance and final satisfaction questionnaires. Results: Forty-five patients (83.3%) ran the app at least once; Twenty-nine (53.7%) subjects were half-compliant, while 16 (29.6%) were fully compliant. Adherence was hindered by technical issues or digital illiteracy (38.7%), demotivation (24%) and health-related issues (7.4%). Ten patients (18.5%) underwent PD therapy changes. The main factors related to lack of compliance included loss of interest, sadness, anxiety, the absence of a caregiver, the presence of falls and higher H&Y. Gait, tapping, tremor and cognitive application outcomes were correlated to disease duration, UPDRS-III and H&Y. Discussion: The majority of patients were compliant and satisfied by the provided monitoring program. Some of the application outcomes were statistically correlated to clinical parameters, but further validation is required. Our pilot study suggested that the available technologies could be readily implemented even with the current population's technical and intellectual resources.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA