Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 63(2): 456-64, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20099333

RESUMO

Imaging with hyperpolarized 3-helium is becoming an increasingly important technique for MRI diagnostics of the lung but is hampered by long breath holds (>20 sec), which are not always applicable in patients with severe lung disease like chronic obstructive pulmonary disease (COPD) or alpha-1-anti-trypsin deficiency. Additionally, oxygen-induced depolarization decay during the long breath holds complicates interpretation of functional data such as apparent diffusion coefficients. To address these issues, we describe and validate a 1.5-T, 32-channel array coil for accelerated (3)He lung imaging and demonstrate its ability to speed up imaging (3)He. A signal-to-noise ratio increase of up to a factor of 17 was observed compared to a conventional double-resonant birdcage for unaccelerated imaging, potentially allowing increased image resolution or decreased gas production requirements. Accelerated imaging of the whole lung with one-dimensional and two-dimensional acceleration factors of 4 and 4 x 2, respectively, was achieved while still retaining excellent image quality. Finally, the potential of highly parallel detection in lung imaging is demonstrated with high-resolution morphologic and functional images.


Assuntos
Hélio , Aumento da Imagem/instrumentação , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Isótopos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Anal Bioanal Chem ; 386(1): 109-18, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16847624

RESUMO

A combined setup for spatially resolved mass analysis of trace amounts of elements and macromolecules is presented. Using a MALDI-TOF mass spectrometer, a laser spectroscopic setup for resonant ionization of neutral atoms has been implemented. This allows for an efficient and selective detection of trace elements by means of resonance ionization mass spectrometry (RIMS). The instrumental scheme is described, and methodological developments are presented. In a first application pure, laser desorption/ionization with TOF-MS was used to measure mass distributions of cosmic nanodiamonds. For further applications regarding the spatially resolved ultra-trace analysis of elements in solid samples, an implanted target was used to characterize both laser desorption/ionization and laser desorption/resonance ionization for the detection of trace elements within. A perspective of the setup is given and future investigations are outlined.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA