Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur Radiol ; 34(4): 2394-2404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37735276

RESUMO

OBJECTIVE: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. METHODS: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. RESULTS: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6-40%. CONCLUSION: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Abdome
2.
Phys Eng Sci Med ; 46(3): 1297-1308, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37439965

RESUMO

In this study, we aimed to examine the effect of varying ß-values in the block sequential regularized expectation maximization (BSREM) algorithm under differing lesion sizes to determine an optimal penalty factor for clinical application. The National Electrical Manufacturers Association phantom and 15 prostate cancer patients were injected with 68Ga-PSMA and scanned using a GE Discovery IQ PET/CT scanner. Images were reconstructed using ordered subset expectation maximization (OSEM) and BSREM with different ß-values. Then, the background variability (BV), contrast recovery, signal-to-noise ratio, and lung residual error were measured from the phantom data, and the signal-to-background ratio (SBR) and contrast from the clinical data. The increment of BV using a ß-value of 100 was 120.0%, and the decrement of BV using a ß-value of 1000 was 40.5% compared to OSEM. As ß decreased from 1000 to 100, the [Formula: see text] increased by 59.0% for a sphere with a diameter of 10 mm and 26.4% for a sphere with a diameter of 37 mm. Conversely, [Formula: see text] increased by 140.5% and 29.0% in the smallest and largest spheres, respectively. Furthermore, the Δ[Formula: see text] and Δ[Formula: see text] were - 41.1% and - 36.7%, respectively. In the clinical study, OSEM exhibited the lowest SBR and contrast. When the ß-value was reduced from 500 to 100, the SBR and contrast increased by 69.7% and 71.8% in small and 35.6% and 33.0%, respectively, in large lesions. Moreover, the optimal ß-value decreased as lesion size decreased. In conclusion, a ß-value of 400 is optimal for small lesion reconstruction, while ß-values of 600 and 500 are optimal for large lesions in phantom and clinical studies, respectively.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X
3.
World J Nucl Med ; 22(2): 124-129, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37223627

RESUMO

Objective This study aims to assess the impact of various regions of interest (ROIs) and volumes of interest (VOIs) delineations on the reproducibility of liver signal-to-noise-ratio (SNRliver) measurements, as well as to find the most reproducible way to estimate it in gallium-68 positron emission tomography ( 68 Ga-PET) imaging. We also investigated the SNRliver-weight relationship for these ROIs and VOIs delineations. Methods A cohort of 40 patients (40 males; mean weight: 76.5 kg [58-115 kg]) with prostate cancer were included. 68 Ga-PET/CT imaging (mean injected activity: 91.4 MBq [51.2 MBq to 134.1 MBq] was performed on a 5-ring bismuth germanium oxide-based Discovery IQ PET/CT using ordered subset expectation maximization image reconstruction algorithm. Afterward, circular ROIs and spherical VOIs with two different diameters of 30 and 40 mm were drawn on the right lobe of the livers. The performance of the various defined regions was evaluated by the average standardized uptake value (SUV mean ), standard deviation (SD) of the SUV (SUV SD ), SNR liver , and SD of the SNR liver metrics. Results There were no significant differences in SUV mean among the various ROIs and VOIs ( p > 0.05). On the other hand, the lower SUV SD was obtained by spherical VOI with diameter of 30 mm. The largest SNR liver was obtained by ROI (30 mm). The SD of SNR liver with ROI (30 mm) was also the largest, while the lowest SD of SNR liver was observed for VOI (40 mm). There is a higher correlation coefficient between the patient-dependent parameter of weight and the image quality parameter of SNRliver for both VOI (30 mm) and VOI (40 mm) compared to the ROIs. Conclusion Our results indicate that SNR liver measurements are affected by the size and shape of the respective ROIs and VOIs. The spherical VOI with a 40 mm diameter leads to more stable and reproducible SNR measurement in the liver.

4.
Pediatr Radiol ; 52(3): 445-452, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34866159

RESUMO

BACKGROUND: Radiation dose metrics vary by the calibration reference phantom used to report doses. By convention, 16-cm diameter cylindrical polymethyl-methacyrlate phantoms are used for head imaging and 32-cm diameter phantoms are used for body imaging in adults. Actual usage patterns in children remain under-documented. OBJECTIVE: This study uses the University of California San Francisco International CT Dose Registry to describe phantom selection in children by patient age, body region and scanner manufacturer, and the consequent impact on radiation doses. MATERIALS AND METHODS: For 106,837 pediatric computed tomography (CT) exams collected between Jan. 1, 2015, and Nov. 2, 2020, in children up to 17 years of age from 118 hospitals and imaging facilities, we describe reference phantom use patterns by body region, age and manufacturer, and median and 75th-percentile dose-length product (DLP) and volume CT dose index (CTDIvol) doses when using 16-cm vs. 32-cm phantoms. RESULTS: There was relatively consistent phantom selection by body region. Overall, 98.0% of brain and skull examinations referenced 16-cm phantoms, and 95.7% of chest, 94.4% of abdomen and 100% of cervical-spine examinations referenced 32-cm phantoms. Only GE deviated from this practice, reporting chest and abdomen scans using 16-cm phantoms with some frequency in children up to 10 years of age. DLP and CTDIvol values from 16-cm phantom-referenced scans were 2-3 times higher than 32-cm phantom-referenced scans. CONCLUSION: REFERENCE PHANTOM SELECTION IS HIGHLY CONSISTENT, WITH A SMALL BUT SIGNIFICANT NUMBER OF ABDOMEN AND CHEST SCANS (~5%) USING 16-CM PHANTOMS IN YOUNGER CHILDREN, WHICH PRODUCES DLP VALUES APPROXIMATELY TWICE AS HIGH AS EXAMS REFERENCED TO 32-CM PHANTOMS.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Adulto , Criança , Humanos , Imagens de Fantasmas , Doses de Radiação , Sistema de Registros , Tomografia Computadorizada por Raios X/métodos
5.
Eur Radiol ; 32(3): 1971-1982, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34642811

RESUMO

OB JECTIVES: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. METHODS: Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. RESULTS: The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. CONCLUSIONS: DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. KEY POINTS: • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Níveis de Referência de Diagnóstico , Humanos , Doses de Radiação , Valores de Referência , Sistema de Registros , Tomografia Computadorizada por Raios X
6.
Cardiol Young ; : 1-6, 2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34663483

RESUMO

Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting. We conducted a single centre retrospective chart review of neonates with ductal-dependent pulmonary blood flow who underwent patent ductus arteriosus stenting between January 1, 2014 and June 31, 2020. We compared patients variables between patients who underwent pre-procedural computed tomography imaging to those who did not. A total of 64 patients were referred for patent ductus arteriosus stenting with 33 (52%) obtaining pre-procedural computed tomography imaging. Average age [19 days; range 1-242 days (p = 0.85)] and weight [3.3 kg (range 2.2-6.0 kg; p = 0.19)] was not significantly different between the groups. A diagnosis of pulmonary atresia was made in 42 out of 64 (66%) patients prior to patent ductus arteriosus stenting. The cohort with pre-intervention computed tomography imaging had a significant reduction in the total number of access sites (1.2 versus 1.5; p = 0.03), contrast needed (5.9 versus 8.2 ml/kg; p = 0.008), fluoroscopy (20.7 versus 38.8 minutes; p = 0.02) and procedural time (83.4-128.4 minutes; p = 0.002) for the intervention. There was no significant difference in radiation burden between the groups (p = 0.35). Pre-procedural computed tomography imaging adds value by aiding interventional planning for neonatal patent ductus arteriosus stenting. A statistically significant reduction in the number of access sites, contrast exposure, as well as fluoroscopic and procedural time was noted without significantly increasing the cumulative radiation burden.

7.
JAMA Intern Med ; 180(5): 666-675, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32227142

RESUMO

Importance: Computed tomography (CT) radiation doses vary across institutions and are often higher than needed. Objective: To assess the effectiveness of 2 interventions to reduce radiation doses in patients undergoing CT. Design, Setting, and Participants: This randomized clinical trial included 864 080 adults older than 18 years who underwent CT of the abdomen, chest, combined abdomen and chest, or head at 100 facilities in 6 countries from November 1, 2015, to September 21, 2017. Data analysis was performed from October 4, 2017, to December 14, 2018. Interventions: Imaging facilities received audit feedback alone comparing radiation-dose metrics with those of other facilities followed by the multicomponent intervention, including audit feedback with targeted suggestions, a 7-week quality improvement collaborative, and best-practice sharing. Facilities were randomly allocated to the time crossing from usual care to the intervention. Main Outcomes and Measures: Primary outcomes were the proportion of high-dose CT scans and mean effective dose at the facility level. Secondary outcomes were organ doses. Outcomes after interventions were compared with those before interventions using hierarchical generalized linear models adjusting for temporal trends and patient characteristics. Results: Across 100 facilities, 864 080 adults underwent 1 156 657 CT scans. The multicomponent intervention significantly reduced proportions of high-dose CT scans, measured using effective dose. Absolute changes in proportions of high-dose scans were 1.1% to 7.9%, with percentage reductions in the proportion of high-dose scans of 4% to 30% (abdomen: odds ratio [OR], 0.82; 95% CI, 0.77-0.88; P < .001; chest: OR, 0.92; 95% CI, 0.86-0.99; P = .03; combined abdomen and chest: OR, 0.49; 95% CI, 0.41-0.59; P < .001; and head: OR, 0.71; 95% CI, 0.66-0.76; P < .001). Reductions in the proportions of high-dose scans were greater when measured using organ doses. The absolute reduction in the proportion of high-dose scans was 6.0% to 17.2%, reflecting 23% to 58% reductions in the proportions of high-dose scans across anatomical areas. Mean effective doses were significantly reduced after multicomponent intervention for abdomen (6% reduction, P < .001), chest (4%, P < .001), and chest and abdomen (14%, P < .001) CT scans. Larger reductions in mean organ doses were 8% to 43% across anatomical areas. Audit feedback alone reduced the proportions of high-dose scans and mean dose, but reductions in observed dose were smaller. Radiologist's satisfaction with CT image quality was unchanged and high during all periods. Conclusions and Relevance: For imaging facilities, detailed feedback on CT radiation dose combined with actionable suggestions and quality improvement education significantly reduced doses, particularly organ doses. Effects of audit feedback alone were modest. Trial Registration: ClinicalTrials.gov Identifier: NCT03000751.


Assuntos
Abdome/diagnóstico por imagem , Doses de Radiação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
J Med Imaging (Bellingham) ; 7(5): 055502, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37476354

RESUMO

Purpose: Foreign body aspiration is difficult to diagnose because many aspirated foreign bodies are low density or radiolucent. Digital radiographs (DR) are poor at detecting radiolucent foreign bodies. Digital tomosynthesis (DTS) has been shown to be ideally suited for applications where DR is insensitive and the increased dose from computed tomography (CT) is not justified. Our objective was to determine if DTS can be a practical alternative to DR and CT in the diagnosis of foreign body aspiration. Approach: A phantom approximating the densities of a pediatric chest was constructed. Radiolucent foreign bodies were placed in the airways. Seven pediatric radiologists assessed DTS and DR images with and without simulated breathing motion. Two rounds were performed with fixed exposure techniques and then automatic exposure control techniques. Interobserver agreement was evaluated using Fleiss' kappa. Results: DTS and DR images using fixed exposure techniques performed very poorly with accuracies of 42% to 60%. DTS with automatic exposure control techniques increased accuracy to 84% for a stationary phantom, but the accuracy dropped to 70% in a phantom with simulated motion. DTS outperformed DR, with DR accuracies of 60% and 63% for stationary simulations and motion, respectively. Interobserver agreement was poor with Fleiss' kappa of 0.476. Conclusion: DTS is superior to DR for radiolucent foreign body detection. However, the overall accuracy and interobserver agreement are likely too low for this modality to be clinically useful.

9.
Radiol Res Pract ; 2018: 3835810, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29850245

RESUMO

Interpretation of radiolucent foreign bodies (FBs) is a common task charged to pediatric radiologists. The use of a motion compensated technique to decrease breathing motion on images would greatly decrease overall exposure to ionizing radiation and increase access to treatment yielding a great impact on clinical care. This study reports on the methodology and materials used to construct an in-house anthropomorphic phantom for investigating image quality in digital tomosynthesis protocols for volumetric imaging of the pediatric airway. Availability and cost of possible substitute materials were considered and simplifying assumptions were made. Two different modular phantoms were assembled in coronal slab layers using materials designed to approximate a one- and three-year-old thorax at diagnostic photon energies for use with digital tomosynthesis protocols such as those offered on GE's VolumeRAD application. Exposures were made using both phantoms with inserted food particles inside an oscillating airway. The goal of the phantom is to help evaluate (1) whether the currently used protocol is sufficient to image the airway despite breathing motion and (2) whether it is not, to find the optimal protocol by testing various commercially available protocols using this phantom. The affordable construction of the pediatric sized phantom aimed at optimizing GE's VolumeRAD protocol for airway foreign body imaging is demonstrated in this study which can be used to test VolumeRAD's ability to image the airways with and without a low-density foreign body within the airways.

10.
J Am Coll Radiol ; 15(5): 809-817, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29555251

RESUMO

Effective radiation risk communication is a core competency for radiology care providers and can prevent and resolve potential conflicts while helping achieve effective public health safeguards. The authors present a synopsis of the challenges to holding such dialogue and review published methods for strengthening and maintaining this discourse. Twelve strategies are discussed in this article that can help alleviate concerns about the iatrogenic risk associated with medical imaging using radiation exposure.


Assuntos
Comunicação , Pais/psicologia , Relações Profissional-Família , Tomografia Computadorizada por Raios X/efeitos adversos , Criança , Tomada de Decisões , Humanos , Exposição à Radiação , Proteção Radiológica , Risco , Medição de Risco
11.
Pediatr Radiol ; 45(2): 228-34, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25056230

RESUMO

BACKGROUND: Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. OBJECTIVE: The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. MATERIALS AND METHODS: A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. RESULTS: During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. CONCLUSION: Implementation of a competency check-off for radiology resident trainees can reduce average radiation doses in pediatric patients undergoing three common fluoroscopic studies.


Assuntos
Lista de Checagem , Educação de Pós-Graduação em Medicina/métodos , Proteção Radiológica/métodos , Radiologia/educação , Pré-Escolar , Feminino , Fluoroscopia , Gastroenteropatias/diagnóstico por imagem , Humanos , Internato e Residência , Masculino , Doenças Faríngeas/diagnóstico por imagem , Doses de Radiação , Estudos Retrospectivos , Urografia/métodos
12.
J Appl Clin Med Phys ; 15(1): 4308, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24423833

RESUMO

A Hindmarsh-Rose model perceptibility phantom containing inserts with various in vitro atherosclerotic plaque compositions was constructed and imaged on a clinical 64 slice multidetector (MDCT) system using 80 and 120 kVp settings and two other cone-beam (CBCT) systems at 80 kVp. Perceptibility of the simulated lipid-fibrotic plaque solutions in the images was evaluated by six observers. The effective doses of the protocols employed were estimated using phantom CTDI-vol measurements placed at identical settings. The CBCT system allowed reduction in effective dose in comparison with the conventional MDCT system for imaging of the carotid plaque phantoms without degrading image quality. The CBCT dose was less than MDCT, with a mean dose of 1.14 ± 0.01 mSv and 1.11 ± 0.02 mSv for MDCT using two measuring techniques vs. 0.35 ± 0.01 mSv for CBCT. The image quality analysis showed no significant differences in the contrast-detail (C-D) curves of the best performing CBCT vs. clinical MDCT (p > 0.05) using a Mann-Whitney U test. Results indicate that low-tube-potential CBCT may produce comparable C-D resolution for phantom-based representations of soft plaque types with respect to MDCT systems. This study suggests that the utility of low kVp CT techniques for evaluating carotid vulnerable atherosclerotic plaque merits further study.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Placa Aterosclerótica/patologia , Monitoramento de Radiação , Algoritmos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação
13.
Radiol Res Pract ; 2011: 808795, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22191030

RESUMO

The aims of this study were to determine whether standard extracellular contrast agents of Gd(III) ions in combination with a polymeric entity susceptible to hydrolytic degradation over a finite period of time, such as Hyaluronic Acid (HA), have sufficient vascular residence time to obtain comparable vascular imaging to current conventional compounds and to obtain sufficient data to show proof of concept that HA with Gd-DTPA ligands could be useful as vascular imaging agents. We assessed the dynamic relaxivity of the HA bound DTPA compounds using a custom-made phantom, as well as relaxation rates at 10.72 MHz with concentrations ranging between 0.09 and 7.96 mM in phosphate-buffered saline. Linear dependences of static longitudinal relaxation rate (R1) on concentration were found for most measured samples, and the HA samples continued to produce high signal strength after 24 hours after injection into a dialysis cassette at 3T, showing superior dynamic relaxivity values compared to conventional contrast media such as Gd-DTPA-BMA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA