Eur Arch Otorhinolaryngol ; 281(1): 515-521, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37831133

RESUMO

BACKGROUND: Due to the complexity of reconstructing wide inferomedial orbital wall fractures, silicone sheets are the preferred choice of reconstructive material. Nevertheless, it is crucial to remove the silicone sheet postoperatively due to the risk of delayed complications associated with its placement. METHODS: We developed a procedure in which a silicone sheet implanted in the orbit can be extracted through the nasal cavity by removing the fractured portion of the medial orbital wall. CONCLUSION: This procedure enables the utilization of silicone sheets, which are suitable for intricate orbital reconstruction, without any concerns regarding delayed complications.


Assuntos
Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Silicones , Órbita/cirurgia , Cavidade Nasal/cirurgia , Próteses e Implantes , Fraturas Orbitárias/cirurgia
2.
Braz. j. otorhinolaryngol. (Impr.) ; 89(3): 447-455, May-June 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447702

RESUMO

Abstract Objective Pediatric orbital blowout fractures can include pathologies that seem mild but require urgent release; serious sequelae can occur with standby surgery or conservative treatment. We sought to validate an algorithm for the treatment of pediatric orbital blowout fractures. Methods This retrospective cohort study included 61 pediatric patients, aged 18 years or younger, treated for pure orbital blowout fractures according to the algorithm from April 1, 2000, to August 31, 2020, at the Japanese Red Cross Asahikawa Hospital. Results There were 52 males (85%). Median age was 14 years (range, 5-18 years). There were 9 patients categorized as needing urgent release, 16 as needing repair, and 36 as needing conservative treatment. Mean follow-up ocular movement was 98.0 (95% Confidence Interval [95% CI], 96.8-99.2). Postoperative diplopia was not observed in 96% (79.6%-99.9%) of patients, better than in previous studies. A higher proportion of patients aged 0-12 years needed urgent repair than those aged 13-18 years (Odds Ratio [OR] = 14.2; 95% CI 1.6-683.4; p= 0.0046). There were no differences in Hess area ratio by age group. Conclusion Clinical results with the algorithm were satisfactory. The algorithm is suitable for treatment of pediatric orbital blowout fractures. Level of evidence 4.

3.
Braz J Otorhinolaryngol ; 89(3): 447-455, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36754674

RESUMO

OBJECTIVE: Pediatric orbital blowout fractures can include pathologies that seem mild but require urgent release; serious sequelae can occur with standby surgery or conservative treatment. We sought to validate an algorithm for the treatment of pediatric orbital blowout fractures. METHODS: This retrospective cohort study included 61 pediatric patients, aged 18 years or younger, treated for pure orbital blowout fractures according to the algorithm from April 1, 2000, to August 31, 2020, at the Japanese Red Cross Asahikawa Hospital. RESULTS: There were 52 males (85%). Median age was 14 years (range, 5-18 years). There were 9 patients categorized as needing urgent release, 16 as needing repair, and 36 as needing conservative treatment. Mean follow-up ocular movement was 98.0 (95% Confidence Interval [95% CI], 96.8-99.2). Postoperative diplopia was not observed in 96% (79.6%-99.9%) of patients, better than in previous studies. A higher proportion of patients aged 0-12 years needed urgent repair than those aged 13-18 years (Odds Ratio [OR] = 14.2; 95% CI 1.6-683.4; p = 0.0046). There were no differences in Hess area ratio by age group. CONCLUSION: Clinical results with the algorithm were satisfactory. The algorithm is suitable for treatment of pediatric orbital blowout fractures.


Assuntos
Fraturas Orbitárias , Masculino , Humanos , Criança , Adolescente , Estudos Retrospectivos , Fraturas Orbitárias/complicações , Fraturas Orbitárias/cirurgia , Diplopia/complicações , Diplopia/cirurgia , Algoritmos , Progressão da Doença
5.
Eur Arch Otorhinolaryngol ; 279(12): 5955-5961, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35951106

RESUMO

BACKGROUND: In orbital floor reconstruction, fractures involving the slope of the posterior end of the orbital floor make it difficult to determine the best location for implant placement. Therefore, landmarks for reconstruction are desirable to perform safe and reproducible reconstruction surgery. METHODS: We developed a surgical procedure that focuses on three orbital landmarks: the infraorbital nerve, the inferior margin of the greater wing of the sphenoid bone, and the posterior superior wall of the maxilla. CONCLUSIONS: Landmark-based orbital floor fracture reconstruction enables accurate reconstruction of fractures that extend to the slope of the posterior end of the orbital floor.


Assuntos
Órbita , Fraturas Orbitárias , Humanos , Órbita/diagnóstico por imagem , Órbita/cirurgia , Órbita/inervação , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Osso Esfenoide , Maxila , Próteses e Implantes