Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 9(6): 517-526, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28225302

RESUMO

AIM: We present a fast magnetic immunoassay, combining magnetic nanoparticles and micromagnets. High magnetic field gradients from micromagnets are used to develop a new approach to the standard ELISA. Materials & methods/results: A proof-of-concept based on colorimetric quantification of antiovalbumin antibody in buffer is performed and compared with an ELISA. After optimization, the magnetic immunoassay exhibits a limit of detection (40 ng/ml) and a dynamic range (40-2500 ng/ml) similar to that of ELISAs developed using same biochemical tools. CONCLUSION: Micromagnets can be fully integrated in multiwell plates at low cost to allow the efficient capture of immunocomplexes carried by magnetic nanoparticles. The method is generic and permits to perform magnetic ELISA in 30 min.


Assuntos
Anticorpos Monoclonais/análise , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Imãs/química , Nanopartículas/química , Ovalbumina/análise , Técnicas Biossensoriais/instrumentação , Colorimetria/métodos , Ensaio de Imunoadsorção Enzimática , Imunoensaio/instrumentação , Limite de Detecção , Campos Magnéticos , Ovalbumina/imunologia
2.
Lab Chip ; 11(18): 3153-61, 2011 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-21808772

RESUMO

Cell arrays are of foremost importance for many applications in pharmaceutical research or fundamental biology. Although arraying techniques have been widely investigated for adherent cells, organization of cells in suspension has been rarely considered. The arraying of non-adherent cells using the diamagnetic repulsive force is presented. A planar arrangement of Jurkat cells is achieved at the microscale above high quality microfabricated permanent magnets with remanent magnetization of J(r)≈ 1 T, in the presence of a paramagnetic contrast agent. The cytotoxicity of three Gd based contrast agents, Gd-DOTA, Gd-BOPTA and Gd-HP-DO3A, is studied. Among them, Gd-HP-DO3A appears to be the most biocompatible toward Jurkat cells. In close agreement with analytical simulations, diamagnetically 'suspended' cells have been successfully arrayed above square and honeycomb-like micromagnet arrays, which act as a "diamagnetophobic" surface. Living cell trapping is achieved in a simple manner using concentrations of Gd-HP-DO3A as low as 1.5 mM.


Assuntos
Técnicas de Cultura de Células/instrumentação , Imãs , Análise Serial de Tecidos/instrumentação , Processos de Crescimento Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Meios de Contraste/farmacologia , Desenho de Equipamento , Gadolínio , Compostos Heterocíclicos/farmacologia , Humanos , Células Jurkat , Meglumina/análogos & derivados , Meglumina/farmacologia , Compostos Organometálicos/farmacologia
3.
J Psychol ; 145(3): 229-45, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21560806

RESUMO

On the basis of J. G. Borkowski, L. K. Chan, and N. Muthukrishna's model of academic success (2000), the present authors hypothesized that freshman retention in an engineering program would be related to not only basic aptitude but also affective factors. Participants were 129 college freshmen with engineering as their stated major. Aptitude was measured by SAT verbal and math scores, high school grade-point average (GPA), and an assessment of calculus readiness. Affective factors were assessed by the NEO-Five Factor Inventory (FFI; P. I. Costa & R. R. McCrae, 2007), and the Nowicki-Duke Locus of Control (LOC) scale (S. Nowicki & M. Duke, 1974). A binary logistic regression analysis found that calculus readiness and high school GPA were predictive of retention. Scores on the Neuroticism and Openness subscales from the NEO-FFI and LOC were correlated with retention status, but Openness was the only affective factor with a significant unique effect in the binary logistic regression. Results of the study lend modest support to Borkowski's model.


Assuntos
Logro , Aptidão , Caráter , Engenharia/educação , Matemática , Adolescente , Escolha da Profissão , Feminino , Humanos , Masculino , Modelos Psicológicos , Inventário de Personalidade/estatística & dados numéricos , Psicometria , Evasão Escolar/psicologia , Adulto Jovem
4.
Anal Chem ; 83(11): 4126-31, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21500859

RESUMO

Diamagnetic levitation of water droplets in air is a promising phenomenon to achieve contactless manipulation of chemical or biochemical samples. This noncontact handling technique prevents contaminations of samples as well as provides measurements of interaction forces between levitating reactors. Under a nonuniform magnetic field, diamagnetic bodies such as water droplets experience a repulsive force which may lead to diamagnetic levitation of a single or few micro-objects. The levitation of several repulsively charged picoliter droplets was successfully performed in a ~1 mm(2) adjustable flat magnetic well provided by a centimeter-sized cylindrical permanent magnet structure. Each droplet position results from the balance between the centripetal diamagnetic force and the repulsive Coulombian forces. Levitating water droplets self-organize into satellite patterns or thin clouds, according to their charge and size. Small triangular lattices of identical droplets reproduce magneto-Wigner crystals. Repulsive forces and inner charges can be measured in the piconewton and the femtocoulomb ranges, respectively. Evolution of interaction forces is accurately followed up over time during droplet evaporation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA