Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur Radiol ; 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38195730

RESUMO

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.

2.
Sci Rep ; 12(1): 15307, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36096919

RESUMO

Transthoracic echocardiography (TTE) and cine cardiac magnetic resonance imaging (CMR) are established imaging methods of the aortic root. We aimed to evaluate the comparability of measurements in TTE and standard cine CMR sequences of the aortic root. Our study included 741 subjects (mean age 63.5 ± 8 years, 43.7% female) from the Hamburg City Health Study (HCHS). Subjects underwent CMR and TTE. Aortic root measurements were performed at the level of the aortic annulus (AoAn), sinus of Valsalva (SoV), and sinotubular junction (STJ) by standard cine CMR in left ventricular long axis and left ventricular outflow tract view. Measurements were performed applying the leading-edge to leading-edge (LL) convention and inner-edge to inner-edge (II) convention in TTE and the II convention in CMR. Inter correlation coefficients (ICCs) demonstrated high inter- and intraobserver reproducibility for CMR and TTE measurements of SoV and STJ (ICCs 0.9-0.98) and moderate reproducibility for AoAn (ICCs 0.68-0.91). CMR measurements of SoV and STJ showed strong agreement with TTE: while correlations were comparable (r = 0.75-0.85) bias was lower with TTE II (bias - 0.1 to - 0.74) versus TTE LL measurements (mean bias - 1.49 to - 2.58 mm). The agreement for AoAn was fair (r = 0.51-0.57) with variable bias (mean bias 0.39-3.9). Standard cine CMR and TTE derived aortic root measurements are reproducible and comparable with higher agreement for TTE II instead of LL measurements. These results support an interchangeable application of TTE and standard CMR for screening of aortic root diseases thereby possibly reducing redundant multimodality imaging.


Assuntos
Doenças da Aorta , Ecocardiografia , Idoso , Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
Eur J Radiol ; 141: 109813, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34116453

RESUMO

PURPOSE: We evaluated the accuracy of preoperative CT in staging colonic diverticulitis (ACD) by using the classification of diverticular disease (CDD) and investigated the diagnostic impact of water enema (WE) and visceral obesity. METHODS: In this retrospective study, the radiological and hospital information system was searched for patients who underwent CT for clinically suspected ACD prior to surgery between 2009 and 2019. From the initial population (n = 164), we included 155 patients (94.5 %) (85 women; mean age: 58 ±â€¯13 years) matching the following inclusion criteria: i.) clinically suspected ACD, ii.) i.v. contrast-enhanced CT, iii.) surgery for ACD within 1 week after CT, iv.) histopathological report that proved ACD. The remaining 9 patients (5.5 %) were excluded because histopathological reports were lacking (n = 3) or CT was performed without intravenous contrast agent (n = 6). WE (+ butylscopolamine i.v.) was performed in 93 patients (group A, 60 %). 62 patients (group B, 40 %) had no WE. Visceral-to-subcutaneous fat ratio (V/S) was determined for each patient. Two radiologists blinded for final diagnosis independently staged ACD according to CDD and assessed prevalence and confidence ratings of ACD-related CT-findings: pericolonic fat stranding, covered- and free-perforation, local and generalized peritonitis, abscess. Interobserver-agreement of CT-findings were assessed and effects of WE and V/S ratio on the diagnostic accuracy of CT with surgical and histopathological findings as reference were determined by calculating a logistic regression model. RESULTS: CT-staging showed high accuracy (94 %) and excellent interrater-correlation (ICC 0.96) for staging ACD. WE had no positive impact neither on diagnostic accuracy of staging, nor on confidence ratings of ACD-related CT-findings (all p > 0.5). Confidence ratings were significantly higher in examinations without WE for perforation, peritonitis as well as abscesses (all p < 0.5). Confidence ratings for the assessment of local peritonitis improved significantly with higher V/S (p = 0.049). The increase of V/S significantly correlated with the probability for correct CDD staging of ACD in CT (p = 0.023). CONCLUSION: Increase of visceral obesity significantly improves accuracy of CT in preoperative staging acute colonic diverticulitis. However, independently of the degree of visceral obesity, water enema has no diagnostic benefit and may therefore be omitted. Overall, CT proves high accuracy in preoperative staging ACD using the classification of diverticular disease. LEVEL OF EVIDENCE: Retrospective study, observational study.


Assuntos
Doença Diverticular do Colo , Obesidade Abdominal , Doença Aguda , Idoso , Doença Diverticular do Colo/diagnóstico por imagem , Enema , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Água
4.
Sci Rep ; 11(1): 4848, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33649416

RESUMO

This methodical work describes the measurement and calculation of pulmonary blood volume in mice based on two imaging techniques namely by using magnetic particle imaging (MPI) and cardiac magnetic resonance imaging (MRI). Besides its feasibility aspects that may influence quantitative analysis are studied. Eight FVB mice underwent cardiac MRI to determine stroke volumes and anatomic MRI as morphological reference for functional MPI data. Arrival time analyses of boli of 1 µl of 1 M superparamagnetic tracer were performed by MPI. Pulmonary transit time of the bolus was determined by measurements in the right and left ventricles. Pulmonary blood volume was calculated out of stroke volume, pulmonary transit time and RR-interval length including a maximal error analysis. Cardiac stroke volume was 31.7 µl ± 2.3 µl with an ejection fraction of 71% ± 6%. A sharp contrast bolus profile was observed by MPI allowing subdividing the first pass into three distinct phases: tracer arrival in the right ventricle, pulmonary vasculature, and left ventricle. The bolus full width at half maximum was 578 ms ± 144 ms in the right ventricle and 1042 ms ± 150 ms in the left ventricle. Analysis of pulmonary transit time revealed 745 ms ± 81 ms. Mean RR-interval length was 133 ms ± 12 ms. Pulmonary blood volume resulted in 177 µl ± 27 µl with a mean maximal error limit of 27 µl. Non-invasive assessment of the pulmonary blood volume in mice was feasible. This technique can be of specific value for evaluation of pulmonary hemodynamics in mouse models of cardiac dysfunction or pulmonary disease. Pulmonary blood volume can complement cardiac functional parameters as a further hemodynamic parameter.


Assuntos
Volume Sanguíneo , Ventrículos do Coração/diagnóstico por imagem , Pulmão , Imageamento por Ressonância Magnética , Volume Sistólico , Função Ventricular Esquerda , Animais , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Camundongos
5.
Eur Radiol ; 29(12): 6953-6964, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31209621

RESUMO

OBJECTIVES: To evaluate the influence of the urinary bladder volume on the detectability of urolithiasis at the ureterovesical junction (UVJ) using a low-dose CT (LD-CT) with iterative reconstruction (IR) and a standard-dose CT (SD-CT) without IR in a large cohort. METHODS: Four hundred patients (278 males (69.5%), mean 44.6 ± 14.7 years) with urolithiasis at the UVJ were investigated either by an LD-CT with IR (n = 289, 72%) or an SD-CT without IR (n = 111, 28%) protocol. The detectability of distal urolithiasis was assessed by a dichotomous assessment (definite or questionable) by two radiologists in consensus and by a quantitative analysis of the signal density distribution across a line drawn parallel to the distal ureter. Based on the resulting graph, minimum/maximum density values and mean/maximum upslopes and downslopes were derived and calculated automatically. In all patients, the total bladder volume was calculated by a slice-by-slice approach on axial CT images. RESULTS: Patients with definite stones showed significantly higher urinary bladder volumes compared to patients with questionable stones in both LD-CT and SD-CT (p < 0.01). These results were independent of stones' length and patients' BMI values. Using cutoffs of 92 ml for LD-CT and 69 ml for SD-CT, high positive predictive values/accuracy rates of 96%/85% (LD-CT) and 98%/86% (SD-CT) were observed to identify definite urinary stones. CONCLUSIONS: Urinary bladder volume has a significant impact on the detectability of distal urolithiasis. Moderate bladder filling by pre-CT hydration with subsequent CT scan at the time of high urge to void increases the detectability of urinary stones at the UVJ in clinical routine. KEY POINTS: • Urinary bladder volume significantly affects the detectability of distal urolithiasis • Higher bladder volumes are associated with improved detectability of distal urinary stones • Oral pre-CT hydration for urolithiasis is easily applicable and cost-effective.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Ureter/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Cálculos Urinários/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Doses de Radiação , Radiologistas , Estudos Retrospectivos , Urolitíase/diagnóstico por imagem , Adulto Jovem
6.
PLoS One ; 12(8): e0180407, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28771481

RESUMO

BACKGROUND: The aim of the study was to quantify atherosclerotic plaque burden by volumetric assessment and T1 relaxivity measurement at 7T MRI using Gadospin F (GDF) in comparison to en face based measurements. METHODS AND RESULTS: 9-weeks old ApoE-/- (n = 5 for each group) and wildtype mice (n = 5) were set on high fat diet (HFD). Progression group received MRI at 9, 13, 17 and 21 weeks after HFD initiation. Regression group was reswitched to chow diet (CD) after 13 weeks HFD and monitored with MRI for 12 weeks. MRI was performed before and two hours after iv injection of GDF (100 µmol/kg) at 7T (Clinscan, Bruker) acquiring a 3D inversion recovery gradient echo sequence and T1 Mapping using Saturation Recovery sequences. Subsequently, aortas were prepared for en face analysis using confocal microscopy. Total plaque volume (TPV) and T1 relaxivity were estimated using ImageJ (V. 1.44p, NIH, USA). 2D and 3D en face analysis showed a strong and exponential increase of plaque burden over time, while plaque burden in regression group was less pronounced. Correspondent in vivo MRI measurements revealed a more linear increase of TPV and T1 relaxivity for regression group. A significant correlation was observed between 2D and 3D en face analysis (r = 0.79; p<0.001) as well as between 2D / 3D en face analysis and MRI (r = 0.79; p<0.001; r = 0.85; p<0.001) and delta R1 (r = 0.79; p<0.001; r = 0.69; p<0.01). CONCLUSION: GDF-enhanced in vivo MRI is a powerful non-invasive imaging technique in mice allowing for reliable estimation of atherosclerotic plaque burden, monitoring of disease progression and regression in preclinical studies.


Assuntos
Apolipoproteínas E/deficiência , Apolipoproteínas E/genética , Técnicas de Inativação de Genes , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Lipídeos/sangue , Camundongos , Placa Aterosclerótica/sangue , Placa Aterosclerótica/genética
7.
Nephrology (Carlton) ; 22(3): 257-260, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28205351

RESUMO

Renovascular stenosis is an important cause for arterial hypertension in childhood. We report a 10-month-old girl with arterial hypertension caused by right-sided renal artery stenosis detected by Doppler ultrasound. Magnetic resonance imaging (MRI) was performed before renal artery angioplasty to depict vascular anatomy in detail and to retrieve additional functional information of the kidneys by analysis of intravoxel incoherent motion (IVIM). The value of quantitative diffusion weighted imaging of the kidneys prior to percutaneous transluminal renal angioplasty (PTRA) is discussed.


Assuntos
Angioplastia , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Lactente , Ultrassonografia
8.
Phys Med Biol ; 62(9): 3454-3469, 2017 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-28060771

RESUMO

Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n = 3) received 60 µl LS-008 (87 mM) and the second (n = 3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and perfusion studies.


Assuntos
Meios de Contraste/farmacocinética , Dextranos/sangue , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Imagem Molecular/métodos , Imagens de Fantasmas , Animais , Meios de Contraste/administração & dosagem , Dextranos/administração & dosagem , Dextranos/farmacocinética , Técnicas In Vitro , Nanopartículas de Magnetita/administração & dosagem , Camundongos , Distribuição Tecidual
9.
Z Med Phys ; 27(1): 6-12, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27312789

RESUMO

AIMS: Radiotherapy of small laboratory animals (SLA) is often not as precisely applied as in humans. Here we describe the use of a dedicated SLA magnetic resonance imaging (MRI) scanner for precise tumor volumetry, radiotherapy treatment planning, and diagnostic imaging in order to make the experiments more accurate. METHODS AND MATERIALS: Different human cancer cells were injected at the lower trunk of pfp/rag2 and SCID mice to allow for local tumor growth. Data from cross sectional MRI scans were transferred to a clinical treatment planning system (TPS) for humans. Manual palpation of the tumor size was compared with calculated tumor size of the TPS and with tumor weight at necropsy. As a feasibility study MRI based treatment plans were calculated for a clinical 6MV linear accelerator using a micro multileaf collimator (µMLC). In addition, diagnostic MRI scans were used to investigate animals which did clinical poorly during the study. RESULTS: MRI is superior in precise tumor volume definition whereas manual palpation underestimates their size. Cross sectional MRI allow for treatment planning so that conformal irradiation of mice with a clinical linear accelerator using a µMLC is in principle feasible. Several internal pathologies were detected during the experiment using the dedicated scanner. CONCLUSION: MRI is a key technology for precise radiotherapy of SLA. The scanning protocols provided are suited for tumor volumetry, treatment planning, and diagnostic imaging.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias Experimentais/radioterapia , Radioterapia Conformacional/métodos , Animais , Animais de Laboratório , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética , Camundongos , Camundongos SCID , Neoplasias Experimentais/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
10.
PLoS One ; 11(6): e0156899, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27249022

RESUMO

PURPOSE: In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI) / magnetic resonance imaging (MRI) road map approach and an MPI-guided approach using a blood pool tracer. MATERIALS AND METHODS: A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4) was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography. RESULTS: Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide. CONCLUSIONS: 4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.


Assuntos
Angioplastia , Catéteres , Imageamento por Ressonância Magnética , Magnetismo , Técnicas In Vitro , Microscopia Eletrônica de Varredura
11.
Invest Radiol ; 51(3): 194-202, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26674208

RESUMO

OBJECTIVES: The aim of this study was to determine metabolic activity of brown adipose tissue (BAT) with in vivo magnetic resonance imaging (MRI) after intravenous (IV) and intraperitoneal (IP) injection of radioactively labeled superparamagnetic iron oxide nanoparticles (SPIOs) embedded into a lipoprotein layer. MATERIALS AND METHODS: Fe-labeled SPIOs were either polymer-coated or embedded into the lipid core of triglyceride-rich lipoproteins (TRL-Fe-SPIOs). First biodistribution and blood half time analysis in thermoneutral mice after IP injection of either TRL-Fe-SPIOs or polymer-coated Fe-SPIOs (n = 3) were performed. In the next step, cold-exposed (24 hours), BAT-activated mice (n = 10), and control thermoneutral mice (n = 10) were starved for 4 hours before IP (n = 10) or IV (n = 10) injection of TRL-Fe-SPIOs. In vivo MRI was performed before and 24 hours after the application of the particles at a 7 T small animal MRI scanner using a T2*-weighted multiecho gradient echo sequence. R2* and ΔR2* were estimated in the liver, BAT, and muscle. The biodistribution of polymer-coated Fe-SPIOs and TRL-Fe-SPIOs was analyzed ex vivo using a sensitive, large-volume Hamburg whole-body radioactive counter. The amount of Fe-SPIOs in the liver, BAT, and muscle was correlated with the MRI measurements using the Pearson correlation coefficient. Tissue uptake of Fe-SPIOs was confirmed by histological and transmission electron microscopy analyses. RESULTS: Triglyceride-rich lipoprotein Fe-SPIOs exhibited a higher blood concentration after IP injection (10.1% ± 0.91% after 24 hours) and a greater [INCREMENT]R2* in the liver (103 ± 5.0 s), while polymer-coated SPIOs did not increase substantially in the blood stream (0.19% ± 0.01% after 24 hours; P < 0.001) and the liver (57 ± 4.08 s; P < 0.001). In BAT activity studies, significantly higher uptake of TRL-Fe-SPIOs was detected in the BAT of cold-exposed mice, with [INCREMENT]R2* of 107 ± 5.5 s after IV application (control mice: [INCREMENT]R2* of 22 ± 5.8 s; P < 0.001) and 45 ± 5.5 s after IP application (control mice: [INCREMENT]R2* of 11 ± 2.9 s; P < 0.01). Fe radioactivity measurements and [INCREMENT]R2* values correlated strongly in BAT (r > 0.85; P < 0.001) and liver tissue (r > 0.85; P < 0.001). Histological and transmission electron microscopy analyses confirmed the uptake of TRL-Fe-SPIOs within the liver and BAT for both application approaches. CONCLUSIONS: Triglyceride-rich lipoprotein-embedded SPIOs were able to escape the abdominal cavity barrier, whereas polymer-coated SPIOs did not increase substantially in the blood stream. Brown adipose tissue activity can be determined via MRI using TRL-Fe-SPIOs. The quantification of [INCREMENT]R2* using TRL-Fe-SPIOs is feasible and may serve as a noninvasive tool for the quantitative estimation of BAT activity.


Assuntos
Tecido Adiposo Marrom/metabolismo , Lipoproteínas/farmacologia , Imageamento por Ressonância Magnética/métodos , Triglicerídeos/farmacologia , Animais , Meios de Contraste/administração & dosagem , Compostos Férricos/administração & dosagem , Injeções Intraperitoneais , Injeções Intravenosas , Lipoproteínas/administração & dosagem , Camundongos , Nanopartículas , Distribuição Tecidual , Triglicerídeos/administração & dosagem
12.
Mol Imaging ; 9(4): 211-22, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20643024

RESUMO

The objective of this study was to quantify enzymatic activity on the surface of T cells by magnetic resonance imaging (MRI) using R2 and R2* relaxometry. Lymphoma cells expressing adenosine diphosphate (ADP)-ribosyltransferase 2 (ART2) were incubated with increasing doses of its substrate etheno-nicotinamide adenine dinucleotide (NAD), resulting in increasing amounts of surface protein ADP-ribosylation. Etheno-ADP-ribosylated proteins were detected with monoclonal antibody 1G4 and superparamagnetic iron oxide conjugated secondary antibodies (Ab-SPIO). Labeling efficiency was determined with R2 and R2* relaxometry on a clinical 3.0 T scanner. Parallel aliquots of cells were analyzed by flow cytometry. Cell-bound SPIO conjugates were detected by immunofluorescence and electron microscopy and quantified by atomic absorption spectroscopy. To mimic an inflammatory site in vivo, Ab-SPIO-labeled cells were injected subcutaneously in mice and analyzed by MRI. Immunofluorescence and electron microscopy confirmed cell-surface localization of Ab-SPIO. MRI of Ab-SPIO-labeled cells showed a corresponding signal reduction. Increases in R2 and R2* determined by magnetic resonance relaxometry correlated linearly with the expression level of ART2 and the concentration of the ART2 substrate etheno-NAD. R2 and R2* increases correlated linearly with the results from flow cytometry and atomic absorption spectroscopy analyses. Quantitative R2 and R2* mapping enable noninvasive determination of enzymatic activity on T cells and holds promise for characterization of inflammatory sites in vivo by MRI.


Assuntos
ADP Ribose Transferases/metabolismo , Membrana Celular/enzimologia , Compostos Férricos/metabolismo , Imageamento por Ressonância Magnética/métodos , Linfócitos T/enzimologia , Adenosina Difosfato Ribose/metabolismo , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Linhagem Celular Tumoral , Compostos Férricos/química , Citometria de Fluxo , Modelos Lineares , Camundongos , Camundongos Endogâmicos BALB C , Microscopia Eletrônica de Transmissão , Microscopia de Fluorescência , NAD/metabolismo , NAD/farmacologia , Reprodutibilidade dos Testes , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA