Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Respirol Case Rep ; 11(6): e01169, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37249924

RESUMO

A 56-year-old female lettuce farmer was admitted to the hospital with a low-grade fever, worsening cough, and dyspnoea. A blood test revealed eosinophilia and a high serum IgE concentration. The 3-year follow-up showed that her total IgE level increased in December, peaked in May, and suddenly decreased in August. This result was consistent with the lettuce harvest season. A chest x-ray taken on admission showed an infiltrative shadow in the upper lung field. Chest CT revealed patchy ground glass opacity on the upper lung field and thickening of the bronchial wall. The bronchoalveolar lavage fluid contained 8% eosinophils. She was treated with prednisolone, and her symptoms and radiological findings improved. The 37 kDa protein that reacted with the patient's sera was identified by immunoblot analysis.

2.
Thorac Cancer ; 13(21): 3052-3057, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36122591

RESUMO

BACKGROUND: The desired depth of sedation during flexible bronchoscopy is one in which verbal contact is possible whenever necessary. Although it is common that the depth of sedation is assessed by validated instruments such as the modified observer's assessment of alertness and sedation (MOAA/S) score, the repeated stimulation associated with the assessment can affect the sedation. The bispectral index (BIS) has been widely used for general anesthesia due to its objective and noninvasive nature. However, the utility of BIS monitoring and a target BIS value for use during bronchoscopy have not been fully elucidated. METHODS: We performed a retrospective observational study to assess the utility of the BIS value for monitoring conscious sedation during bronchoscopy at Kobe University Hospital from August 2020 to April 2021. RESULTS: Eighteen patients underwent bronchoscopy with BIS monitoring. The BIS value significantly correlated with the MOAA/S score (r = 0.2, p < 0.01), and the correlation was stronger in sufficiently sedated patients (r = 0.486, p < 0.01). The lowest MOAA/S score during the procedure was highly correlated with the BIS value (r = 0.625, p < 0.01). The BIS monitoring seemed to be more sensitive to changes in the sedation level than the MOAA/S score, heart rate and mean arterial pressure. The median BIS value at an MOAA/S score of 3-4, the desired depth of sedation, was 82.0. CONCLUSIONS: BIS value is useful for monitoring sedation during bronchoscopy. This study suggests that a BIS value of 82 reflects an adequate level of sedation.


Assuntos
Propofol , Humanos , Broncoscopia , Sedação Consciente/métodos , Anestesia Geral , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA