RESUMO
We summarize here the presentation and course of lead poisoning in a 1-year-old who ingested a lead-containing metallic medallion from India. We analyzed the medallion to determine its composition, using x-ray fluorescence spectroscopy and field emission scanning electron microscopy. A simple extraction test was used to estimate oral bioavailability. We used the US Environmental Protection Agency Integrated Exposure Uptake Biokinetic model to compare actual versus predicted blood lead levels. X-ray fluorescence analysis revealed the composition of the medallion to be: Lead 155 000 ppm (15%), copper 530 000 ppm (53%), nickel 49 000 ppm (4.9%), arsenic 22 000 ppm (2.2%), antimony 12 000 ppm (1.2%), tin 3000 ppm (0.3%), and silver 1300 ppm (0.13%). With a fixed ingestion of 7786 µg/d (estimated by simulated gastric extraction analysis) and assuming 50% bioavailability, Integrated Exposure Uptake Biokinetic modeling predicted the geometric mean blood lead level would increase from 2.05 µg/dL to 173.9 µg/dL. This patient had potentially life-threatening lead poisoning from an ingested piece of jewelry. The medallion contained 550 times the allowable content of lead in children's metallic jewelry sold in the United States. This case highlights the ubiquitous nature of lead in our global environment and the risk of exposure to novel sources, especially for children.
Assuntos
Joias , Intoxicação por Chumbo , Humanos , Intoxicação por Chumbo/etiologia , Lactente , Chumbo/sangue , Chumbo/toxicidade , Masculino , ÍndiaRESUMO
BACKGROUND: Untargeted metabolomics has shown promise in expanding screening and diagnostic capabilities for inborn errors of metabolism (IEMs). However, inter-batch variability remains a major barrier to its implementation in the clinical laboratory, despite attempts to address this through normalization techniques. We have developed a sustainable, matrix-matched reference material (RM) using the iterative batch averaging method (IBAT) to correct inter-batch variability in liquid chromatography-high-resolution mass spectrometry-based untargeted metabolomics for IEM screening. METHODS: The RM was created using pooled batches of remnant plasma specimens. The batch size, number of batch iterations per RM, and stability compared to a conventional pool of specimens were determined. The effectiveness of the RM for correcting inter-batch variability in routine screening was evaluated using plasma collected from a cohort of phenylketonuria (PKU) patients. RESULTS: The RM exhibited lower metabolite variability between iterations over time compared to metabolites from individual batches or individual specimens used for its creation. In addition, the mean variation across amino acid (n = 19) concentrations over 12 weeks was lower for the RM (CVtotal = 8.8%; range 4.7%-25.3%) compared to the specimen pool (CVtotal = 24.6%; range 9.0%-108.3%). When utilized in IEM screening, RM normalization minimized unwanted inter-batch variation and enabled the correct classification of 30 PKU patients analyzed 1 month apart from 146 non-PKU controls. CONCLUSIONS: Our RM minimizes inter-batch variability in untargeted metabolomics and demonstrated its potential for routine IEM screening in a cohort of PKU patients. It provides a practical and sustainable solution for data normalization in untargeted metabolomics for clinical laboratories.
RESUMO
Objectives: To determine the diagnostic accuracy of a rapid host-protein test for differentiating bacterial from viral infections in patients who presented to the emergency department (ED) or urgent care center (UCC). Methods: This was a prospective multicenter, blinded study. MeMed BV (MMBV), a test based on tumor necrosis factor-related apoptosis-inducing ligand (TRAIL), interferon gamma-inducible protein-10 (IP-10), and C-reactive protein (CRP), was measured using a rapid measurement platform. Patients were enrolled from 9 EDs and 3 UCCs in the United States and Israel. Patients >3 months of age presenting with fever and clinical suspicion of acute infection were considered eligible. MMBV results were not provided to the treating clinician. MMBV results (bacterial/viral/equivocal) were compared against a reference standard method for classification of infection etiology determined by expert panel adjudication. Experts were blinded to MMBV results. They were provided with comprehensive patient data, including laboratory, microbiological, radiological and follow-up. Results: Of 563 adults and children enrolled, 476 comprised the study population (314 adults, 162 children). The predominant clinical syndrome was respiratory tract infection (60.5% upper, 11.3% lower). MMBV demonstrated sensitivity of 90.0% (95% confidence interval [CI]: 80.3-99.7), specificity of 92.8% (90.0%-95.5%), and negative predictive value of 98.8% (96.8%-99.6%) for bacterial infections. Only 7.2% of cases yielded equivocal MMBV scores. Area under the curve for MMBV was 0.95 (0.90-0.99). Conclusions: MMBV had a high sensitivity and specificity relative to reference standard for differentiating bacterial from viral infections. Future implementation of MMBV for patients with suspected acute infections could potentially aid with appropriate antibiotic decision-making.
RESUMO
Parkinson's disease is a progressive neurodegenerative disorder in which loss of dopaminergic neurons in the substantia nigra results in a clinically heterogeneous group with variable motor and non-motor symptoms with a degree of misdiagnosis. Only 3-25% of sporadic Parkinson's patients present with genetic abnormalities that could represent a risk factor, thus environmental, metabolic, and other unknown causes contribute to the pathogenesis of Parkinson's disease, which highlights the critical need for biomarkers. In the present study, we prospectively collected and analyzed plasma samples from 194 Parkinson's disease patients and 197 age-matched non-diseased controls. N-acetyl putrescine (NAP) in combination with sense of smell (B-SIT), depression/anxiety (HADS), and acting out dreams (RBD1Q) clinical measurements demonstrated combined diagnostic utility. NAP was increased by 28% in Parkinsons disease patients and exhibited an AUC of 0.72 as well as an OR of 4.79. The clinical and NAP panel demonstrated an area under the curve, AUC = 0.9 and an OR of 20.4. The assessed diagnostic panel demonstrates combinatorial utility in diagnosing Parkinson's disease, allowing for an integrated interpretation of disease pathophysiology and highlighting the use of multi-tiered panels in neurological disease diagnosis.
Assuntos
Biomarcadores , Doença de Parkinson , Putrescina , Humanos , Doença de Parkinson/diagnóstico , Masculino , Biomarcadores/sangue , Feminino , Idoso , Pessoa de Meia-Idade , Putrescina/análogos & derivados , Estudos Prospectivos , Estudos de Casos e ControlesRESUMO
Prostate cancer represents a significant health risk to aging men, in which diagnostic challenges to the identification of aggressive cancers remain unmet. Prostate cancer screening is driven by the prostate-specific antigen (PSA); however, in men with benign prostatic hyperplasia (BPH) due to an enlarged prostate and elevated PSA, PSA's screening utility is diminished, resulting in many unnecessary biopsies. To address this issue, we previously identified a cleaved fragment of Filamin A (FLNA) protein (as measured with IP-MRM mass spectrometry assessment as a prognostic biomarker for stratifying BPH from prostate cancer and subsequently evaluated its expanded utility in Caucasian (CA) and African American (AA) men. All men had a negative digital rectal examination (DRE) and PSA between 4 and 10 ng/mL and underwent prostate biopsy. In AA men, FLNA serum levels exhibited diagnostic utility for stratifying BPH from patients with aggressive prostate cancer (0.71 AUC and 12.2 OR in 48 men with BPH and 60 men with PCa) and outperformed PSA (0.50 AUC, 2.2 OR). In CA men, FLNA serum levels also exhibited diagnostic utility for stratifying BPH from patients with aggressive prostate cancer (0.74 AUC and 19.4 OR in 191 men with BPH and 109 men with PCa) and outperformed PSA (0.46 AUC, 0.32 OR). Herein, we established FLNA alone as a serum biomarker for stratifying men with BPH vs. those with high Gleason (7-10) prostate cancers compared to the current diagnostic paradigm of using PSA. This approach demonstrates clinical actionability of FLNA alone without the requirement of prostate volume measurement as a test with utility in AA and CA men and represents a significant opportunity to decrease the number of unnecessary biopsies in aggressive prostate cancer diagnoses.
RESUMO
BACKGROUND: Minimizing hemolysis during phlebotomy ensures accurate chemistry results and reduces test cancellations and specimen recollections. We developed videos demonstrating best practices to reduce hemolysis and tested whether distribution to clinical nurse educators (CNEs) for provision to nursing staff affected the degree of specimen hemolysis in hospital inpatient units and outpatient clinics. METHODS: Videos of common blood collections demonstrating best practices to reduce hemolysis were filmed and then distributed via email link to all hospital-based CNEs in Calgary, Alberta, Canada. (https://vimeo.com/user18866730/review/159869683/a0cec9827f). Roche Cobas hemolysis index (H-index) results from specimens collected +/- 12 months from the date of video distribution were extracted from Roche Cobas IT middleware (cITM) and linked to collection location. An interrupted time series (ITS) analysis with collection location as the unit of anlaysis was used to quantify impact of video distribution on the trajectory of weekly mean log-H-index weighted by inverse variance. RESULTS: In +/- 3 months of data flanking video distribution (n = 137 241 collections), where overall impact was strongest, H-index trajectory (change in units per week) decreased immediately following video distribution (-5.7% / week, p < 0.01). This was accompanied by a 22% drop in overall H-index from the week before to the week after video distribution (y-intercept change, or gap). There was also a small but significant overall decrease in the proportion of hemolyzed specimens (-0.3%, p < 0.01). These changes were not observed at all collection locations, and in fact increases occured at some locations. CONCLUSIONS: We developed a novel and convenient educational aid that, when distributed, was associated with beneficial changes in specimen hemolysis at hospital inpatient units and outpatient clinics. Including it in ongoing nursing education will fill a knowledge gap that may help to reduce specimen hemolysis.
Assuntos
Hemólise , Flebotomia , Humanos , Flebotomia/métodos , Manejo de Espécimes/métodos , Hospitais , Alberta , Coleta de Amostras Sanguíneas/métodosRESUMO
OBJECTIVES: Bacterial musculoskeletal infections (MSKIs) are challenging to diagnose because of the clinical overlap with other conditions, including Lyme arthritis. We evaluated the performance of blood biomarkers for the diagnosis of MSKIs in Lyme disease-endemic regions. METHODS: We conducted a secondary analysis of a prospective cohort study of children 1 to 21 years old with monoarthritis presenting to 1 of 8 Pedi Lyme Net emergency departments for evaluation of potential Lyme disease. Our primary outcome was an MSKI, which was defined as septic arthritis, osteomyelitis or pyomyositis. We compared the diagnostic accuracy of routinely available biomarkers (absolute neutrophil count, C-reactive protein, erythrocyte sedimentation rate, and procalcitonin) to white blood cells for the identification of an MSKI using the area under the receiver operating characteristic curve (AUC). RESULTS: We identified 1423 children with monoarthritis, of which 82 (5.8%) had an MSKI, 405 (28.5%) Lyme arthritis, and 936 (65.8%) other inflammatory arthritis. When compared with white blood cell count (AUC, 0.63; 95% confidence interval [CI], 0.55-0.71), C-reactive protein (0.84; 95% CI, 0.80-0.89; P < .05), procalcitonin (0.82; 95% CI, 0.77-0.88; P < .05), and erythrocyte sedimentation rate (0.77; 95% CI, 0.71-0.82; P < .05) had higher AUCs, whereas absolute neutrophil count (0.67; 95% CI, 0.61-0.74; P < .11) had a similar AUC. CONCLUSIONS: Commonly available biomarkers can assist in the initial approach to a potential MSKI in a child. However, no single biomarker has high enough accuracy to be used in isolation, especially in Lyme disease-endemic areas.
RESUMO
OBJECTIVES: We evaluated the long-term stability of thyroid peroxidase antibody (anti-TPO). METHODS: In the Danish General Suburban Population Study (GESUS), serum samples were biobanked at -80 °C during 2010-2013. In a paired design with 70 subjects, we compared anti-TPO (30-198 U/mL) measured on fresh serum on Kryptor Classic in 2010-2011 (anti-TPOfresh) with anti-TPO remeasured on frozen serum (anti-TPOfrozen) on Kryptor Compact Plus in 2022. Both instruments used the same reagents and the anti-TPOn automated immunofluorescent assay, which was calibrated against the international standard NIBSC 66/387, based on the Time Resolved Amplified Cryptate Emission (TRACE) technology from BRAHMS. Values greater than 60 U/mL are regarded as positive in Denmark with this assay. Statistical comparisons included Bland-Altman, Passing-Bablok regression, and Kappa statistic. RESULTS: The mean follow-up time was 11.9 years (SD: 0.43). For anti-TPOfrozen vs. anti-TPOfresh, the line of equality was within the confidence interval of the absolute mean difference [5.71 (-0.32; 11.7) U/mL] and the average percentage deviation [+2.22% (-3.89%; +8.34%)]. The average percentage deviation of 2.22% did not exceed analytical variability. Passing-Bablok regression revealed both a statistically significant systematic and proportional difference: Anti-TPOfrozen=-22.6 + 1.22*(anti-TPOfresh). Frozen samples were correctly classified as positive in 64/70 (91.4%; Kappa=71.8%). CONCLUSIONS: Anti-TPO serum samples in the range 30-198 U/mL were stable after 12-years of storage at -80 °C with an estimated nonsignificant average percentage deviation of +2.22%. This comparison is based on Kryptor Classic and Kryptor Compact Plus, which used identical assays, reagents, and calibrator, but for which the agreement in the range 30-198 U/mL is unclarified.
Assuntos
Autoanticorpos , Iodeto Peroxidase , Humanos , População Suburbana , DinamarcaRESUMO
STUDY OBJECTIVE: Children with a bacterial musculoskeletal infection (MSKI) require prompt identification and treatment. In Lyme disease endemic areas, children with an MSKI can present similarly to those with Lyme arthritis. Our goal was to derive a clinical prediction rule to accurately identify children at a low risk for an MSKI. METHODS: We enrolled children with monoarthritis presenting to 1 of 6 Pedi Lyme Net centers and performed a procalcitonin (PCT) and a first-tier Lyme C6 enzyme immunoassay (EIA) test. Our primary outcome was an MSKI (septic arthritis, osteomyelitis, or pyomyositis). Using recursive partitioning with k-fold cross validation, we derived a clinical prediction rule to identify children at a low risk of an MSKI. We calculated the accuracy of our novel rule in a derivation cohort. RESULTS: Of the 735 children in the derivation cohort with an available research biosample, 39 (5%) had an MSKI (18 had septic arthritis, 20 had osteomyelitis, and 1 had pyomyositis), 260 (37%) had Lyme arthritis, and 436 (53%) had other inflammatory arthritis. Children with a PCT level of more than or equal to 0.50 ng/mL and those with a C-reactive protein (CRP) level of more than or equal to 0.6 mg/dL with a negative Lyme C6 EIA were classified as not low risk for an MSKI. Of the 451 (61%) children categorized as low risk, none had an MSKI (sensitivity 100%, 95% confidence interval 91.0% to 100%; specificity 74.2%, 95% confidence interval 70.5% to 77.6%). CONCLUSION: A novel clinical decision rule that includes PCT, CRP, and a first-tier Lyme EIA was highly sensitive for MSKIs. Although broader external validation is required, the application of this rule may safely reduce invasive testing, procedures, and treatment for low risk children.
Assuntos
Artrite Infecciosa , Doença de Lyme , Doenças Musculoesqueléticas , Osteomielite , Piomiosite , Artrite Infecciosa/diagnóstico , Artrite Infecciosa/epidemiologia , Criança , Regras de Decisão Clínica , Humanos , Doença de Lyme/complicações , Doença de Lyme/diagnóstico , Doença de Lyme/epidemiologia , Osteomielite/diagnóstico , Osteomielite/epidemiologia , Piomiosite/diagnóstico , Piomiosite/epidemiologiaRESUMO
Introduction: Thiocyanate can cause gastrointestinal, neurologic, and cardiovascular toxicity. Additionally, it interferes with multiple laboratory assays. We present a case of acute thiocyanate toxicity. Case: A 17-year-old female presented with an intentional thiocyanate ingestion. Her course was notable for delirium, wide complex tachycardia, and presumed seizure activity with concurrent lactatemia, acidemia, and narrowing of her arterio-venous oxygen gradient. She received lipid emulsion therapy (LET). While hemodialysis was considered, she recovered without additional treatment. After resolution of her critical illness, a serum cyanide concentration was 0.21 mcg/mL. She had laboratory testing notable for hyperchloremia, hypocalcemia, hypokalemia, and an elevated salicylate concentration attributed to interference by thiocyanate. The thiocyanate was eliminated via first-order kinetics with a half-life of 61.6 hours. Discussion: Thiocyanate poisoning may cause cardiac and neurologic toxicity. Laboratory evidence of impaired cellular respiration in this case suggests possible in vivo conversion to cyanide, however this is not proven. Cyanide antidotal treatment was not administered for this patient, however LET was given based on thiocyanate's lipophilicity. Hemodialysis is known to effectively remove thiocyanate from the blood, however the patient improved without it. The patient's laboratory derangements were due to thiocyanate interference with ion selective electrode and colorimetric analyzer technology. Conclusions: Thiocyanate can cause cardiac and neurologic toxicity, and interferes with several laboratory assays. Theoretically, LET and cyanide antidotal treatment may be useful, but this requires further investigation. Thiocyanate toxicity should be managed supportively, and hemodialysis may be used in severe cases.
Assuntos
Acidose , Tiocianatos , Adolescente , Antídotos/uso terapêutico , Cianetos , Feminino , HumanosRESUMO
Low molecular-mass aliphatic carboxylic acids are critically important for intermediate metabolism and may serve as important biomarkers for metabolic homeostasis. Here in, we focused on multiplexed method development of aliphatic carboxylic analytes, including methylsuccinic acid (MSA), ethylmalonic acid (EMA), and glutaric acid (GA). Also assessed was their utility in a population's health as well as metabolic disease screening in both plasma and urine matrices. MSA, EMA, and GA are constitutional isomers of dicarboxylic acid with high polarity and poor ionization efficiency, resulting in such challenges as poor signal intensity and retention, particularly in reversed-phase liquid chromatography with electrospray mass spectrometry (RP-LC-ESI-MS/MS). Derivatization using n-butanol was performed in the sample preparation to enhance the signal intensity accompanied with a positive charge from ionization in complicated biomatrices as well as to improve the separation of these isomers with optimal retention. Fit-for-purpose method validation results demonstrated quantitative ranges for MSA/EMA/GA from 5/10/20 ng/mL to 400 ng/mL in plasma analysis, and 100/200/100 ng/mL to 5000/10000/5000 ng/mL in urine analysis. This validated method demonstrates future utility when exploring population health analysis and biomarker development in metabolic diseases.
Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Glutaratos , Malonatos , Espectrometria de Massas por Ionização por Electrospray/métodos , Succinatos , Espectrometria de Massas em Tandem/métodosRESUMO
Prostate-specific antigen (PSA) screening for prostate cancer (PCa) is limited by the lack of specificity but is further complicated in the benign prostatic hyperplasia (BPH) population which also exhibit elevated PSA, representing a clear unmet need to distinguish BPH from PCa. Herein, we evaluated the utility of FLNA IP-MRM, age, and prostate volume to stratify men with BPH from those with PCa. Diagnostic performance of the biomarker panel was better than PSA alone in discriminating patients with negative biopsy from those with PCa, as well as those who have had multiple prior biopsies (AUC 0.75 and 0.87 compared to AUC of PSA alone 0.55 and 0.57 for patients who have had single compared to multiple negative biopsies, respectively). Of interest, in patients with PCa, the panel demonstrated improved performance than PSA alone in those with Gleason scores of 5-7 (AUC 0.76 vs. 0.56) and Gleason scores of 8-10 (AUC 0.74 vs. 0.47). With Gleason scores (8-10), the negative predictive value of the panel is 0.97, indicating potential to limit false negatives in aggressive cancers. Together, these data demonstrate the ability of the biomarker panel to perform better than PSA alone in men with BPH, thus preventing unnecessary biopsies.
Assuntos
Biomarcadores Tumorais/sangue , Diagnóstico Diferencial , Hiperplasia Prostática/diagnóstico , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/metabolismo , Antígeno Prostático Específico/sangue , Hiperplasia Prostática/sangue , Hiperplasia Prostática/patologia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologiaRESUMO
BACKGROUND: Neural Cell Adhesion Molecule 1 (NCAM-1), a multifunctional member of the immunoglobulin superfamily, is expressed on the surface of neurons, glia, skeletal muscle, and natural killer cells. NCAM-1 has been implicated as having a role in cell-cell adhesion, involved in development of the nervous system, and for cells involved in the expansion of T cells and dendritic cells which play an important role in immune surveillance. Sensitive and specific methods to quantify non-surface bound NCAM-1 are not available. METHOD: A sandwich ligand binding assay was developed for quantification of NCAM-1 in plasma and validated using an electro-chemiluminescent (ECL) technology. RESULTS: The data presented here demonstrated that the validated method met all prespecified criteria for precision, linearity, and accuracy in the range of 62.5 ng/mL to 4000.0 ng/mL, the range believed to be most relevant for plasma. The bioanalytical validation of the assay established the inter-assay coefficient of variation <8 % for calibration points, <2 % for high quality control (HQC), <8 % for medium quality control (MQC) and <19 % for low quality control (LQC) samples. Purified NCAM-1 spike-recovery experiment in plasma was used to determine assay accuracy; nominal concentrations (%) of NCAM-1 ranged from 91 % to 112 % for high and low spike level, respectively. Assay performance was subsequently evaluated for parallelism, selectivity, interference, and stability. CONCLUSION: NCAM-1 assay has been developed and validated in human plasma and met all assay validation parameters pre-determined during development. Clinical testing of human plasma samples indicated that NCAM-1 does not seem to be influenced by age and was slightly influenced by gender. NCAM-1 assay has potential to be used as a biomarker assay once the assay is subjected to appropriate clinical assessment and diagnostic thresholds are established.
Assuntos
Moléculas de Adesão de Célula Nervosa , Biomarcadores , Antígeno CD56 , Calibragem , Humanos , Imunoensaio , Controle de QualidadeRESUMO
CONTEXT: Human milk contains hormones that regulate metabolism. Extrauterine growth restriction remains common among preterm infants, but the effect of ingesting milk hormones on preterm infant growth is poorly understood. OBJECTIVE: To quantify associations of longitudinal exposure to leptin, adiponectin, and insulin in milk with physical growth of preterm infants. DESIGN/METHODS: In 50 preterm neonates (median gestational age 29.4 weeks), we sampled maternal milk on day-of-life 7, 14, 21, and 28 and measured hormone levels in whole milk by ELISA. Milk leptin levels were available for a subset of 18 infants. We calculated milk hormone doses by multiplying the hormone level by the milk volume ingested on each day and estimated the area under the curve (AUC) to reflect longitudinal exposure. We analyzed associations of milk hormone exposure with growth outcomes in generalized estimated equations. MAIN OUTCOME MEASURES: Weight gain velocity and z-scores in weight, length, head circumference, and body mass index at 36 weeks' postmenstrual age (PMA). RESULTS: Higher leptin intake was associated with greater weight gain (2.17g/kg/day [95% CI, 1.31, 3.02]) and weight z-score at 36 weeks' PMA (0.30 [0.08, 0.53] higher z-score per tertile). Higher adiponectin intake was associated with greater length z-score (0.41 [0.13, 0.69]), however, this association was nullified after adjustment of protein and calorie intake. Higher adiponectin was associated with smaller head circumference z-score (-0.36 [-0.64, -0.07]). Insulin was not associated with growth outcomes. CONCLUSIONS: Milk leptin and adiponectin exposures may affect growth of preterm infants. The long-term effects of milk hormones warrant further investigation.
Assuntos
Desenvolvimento Infantil/fisiologia , Ingestão de Alimentos/fisiologia , Hormônios/administração & dosagem , Leite Humano/fisiologia , Adiponectina/administração & dosagem , Adiponectina/metabolismo , Estudos de Coortes , Feminino , Hormônios/metabolismo , Humanos , Lactente , Fenômenos Fisiológicos da Nutrição do Lactente , Recém-Nascido , Recém-Nascido Prematuro/crescimento & desenvolvimento , Leptina/administração & dosagem , Leptina/metabolismo , Estudos Longitudinais , Masculino , Massachusetts , Leite Humano/química , Leite Humano/metabolismo , Aumento de Peso/fisiologiaRESUMO
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
RESUMO
Global untargeted metabolomics (GUM) has entered clinical diagnostics for genetic disorders. We compared the clinical utility of GUM with traditional targeted metabolomics (TM) as a screening tool in patients with established genetic disorders and determined the scope of GUM as a discovery tool in patients with no diagnosis under investigation. We compared TM and GUM data in 226 patients. The first cohort (n = 87) included patients with confirmed inborn errors of metabolism (IEM) and genetic syndromes; the second cohort (n = 139) included patients without diagnosis who were undergoing evaluation for a genetic disorder. In patients with known disorders (n = 87), GUM performed with a sensitivity of 86% (95% CI: 78-91) compared with TM for the detection of 51 diagnostic metabolites. The diagnostic yield of GUM in patients under evaluation with no established diagnosis (n = 139) was 0.7%. GUM successfully detected the majority of diagnostic compounds associated with known IEMs. The diagnostic yield of both targeted and untargeted metabolomics studies is low when assessing patients with non-specific, neurological phenotypes. GUM shows promise as a validation tool for variants of unknown significance in candidate genes in patients with non-specific phenotypes.
Assuntos
Doenças Genéticas Inatas/genética , Erros Inatos do Metabolismo/genética , Metabolômica/métodos , Adolescente , Biomarcadores/metabolismo , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Testes Genéticos , Humanos , Masculino , Fenótipo , SíndromeRESUMO
BACKGROUND: Vitamin A and E are routinely monitored to assess nutritional status. The most commonly used approach for their measurement involves laborious liquid-liquid extraction followed by high-performance liquid chromatography (HPLC) analysis on dedicated instrumentation. We describe a simple, rapid protocol for measurement of vitamin A and E and their integration into an existing online sample preparation liquid chromatography tandem mass spectrometry (SPLC-MS/MS) workflow. METHODS: We performed a method comparison between the SPLC-MS/MS and HPLC methods for vitamin A and E by measuring patient specimens across the concentration range 11-81 µg/dL for vitamin A and 1-18 mg/L for vitamin E. The analysis times on each platform were also compared. RESULTS: SPLC-MS/MS and HPLC methods were comparable with regards to analytical performance; mean bias across the measured range was 2.54% (95% CL: -11.56-16.64%) for vitamin A and -2.04% (95% CL: -18.20-14.12%) for vitamin E. Total analysis times were 7 min and 15 min for SPLC-MS/MS and HPLC respectively. CONCLUSIONS: The development of a simplified sample preparation protocol and the use of multiplexing SPLC-MS/MS have reduced sample analysis times for vitamin A and E. This method has also optimized clinical workflow through consolidation of previously independent benches.
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Vitamina A/sangue , Vitamina E/sangue , 25-Hidroxivitamina D 2/análise , Anticonvulsivantes/análise , Bussulfano/análise , Humanos , Imunossupressores/análise , Laboratórios/organização & administração , Padrões de Referência , Reprodutibilidade dos Testes , Fluxo de TrabalhoRESUMO
BACKGROUND: Enteral nutrition (EN) intolerance and delayed gastric emptying are prevalent in pediatric critical illness and limit EN delivery. Gastrointestinal (GI) hormones may be associated with EN intolerance and delayed gastric emptying in this cohort. METHODS: We determined GI hormone levels, time to achieve 50% of EN goal, and gastric emptying in critically ill children. Total amylin, active ghrelin, total glucagon-like peptide-1 (GLP-1), total gastric inhibitory polypeptide, glucagon, and total peptide-YY (PYY) were measured by multiplex assay and cholecystokinin by ELISA. Lower concentrations of acetaminophen at 1 hour (C1h, µg/mL) using the acetaminophen absorption test defined delayed gastric emptying. Correlation, regression analyses, and a principal component analysis were used to examine the association between GI hormones and time to 50% EN goal and C1h. RESULTS: GI hormones were measured in 14 of 21 patients with gastric emptying testing; median age of 11.2 years (6.74-16.3) and 50% male. Increasing hormone levels from GI hormone profile 1 (GLP-1, glucagon, and amylin) correlated with greater time to reach 50% EN goal (R2 = 0.296, P = 0.04). Decreasing hormone levels from GI hormone profile 2 (PYY and ghrelin) correlated with lower C1h and slower gastric emptying (R2 = 0.342, P = 0.02). CONCLUSION: GI hormone profiles are associated with time to achieve 50% of EN goal and gastric emptying in critically ill children. We have described a feasible model to study the role of GI hormones in this cohort, including the potential clinical applicability of GI hormone measurement in the management of delayed gastric emptying.
Assuntos
Estado Terminal , Nutrição Enteral , Hormônios Gastrointestinais , Criança , Feminino , Esvaziamento Gástrico , Humanos , Masculino , Projetos PilotoRESUMO
BACKGROUND: Little evidence supports use of chlorhexidine gluconate (CHG) baths to reduce health care-associated infections, including central catheter-associated bloodstream infections in infants less than 2 months old. OBJECTIVE: To describe the safety of biweekly CHG baths in infants less than 2 months old by measuring blood levels of CHG, liver and renal function, skin reactions, and adverse events. METHODS: Study participants received twice-weekly 2% CHG baths, weekly blood tests, and twice-daily skin assessments. Adverse events were monitored. RESULTS: Ten infants 36 to 48 weeks' postmenstrual age with central venous catheters admitted to the neonatal or cardiac intensive care unit were enrolled before the study was closed by the Food and Drug Administration. The 9 patients contributing data had 83 CHG exposures; 31 CHG levels were analyzed. All patients had evidence of CHG absorption. Seven patients had CHG levels of 100 ng/mL or greater. Findings did not support accumulation of CHG but did show evidence of higher absorption than previously reported. Results of liver and renal function studies remained within reference limits. No patient had any adverse events, including skin reactions. CONCLUSIONS: Although no adverse events were observed, our patients had evidence of CHG absorption. The effects of this absorption remain unknown. More research is needed to determine safe blood levels of CHG in infants less than 2 months of age.