Otol Neurotol ; 35(1): 7-15, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24270723

RESUMO

OBJECTIVE: Describe the clinical features of a population of patients with sinus wall anomalies (SWA) and pulse-synchronous tinnitus (PST). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: Patients with PST and SWA undergoing surgical management between 2007 and 2012. INTERVENTION: Transmastoid sinus wall reconstruction. MAIN OUTCOME MEASURE: Age, sex, BMI, and postoperative course. Two-tailed t tests (p ≤ 0.05) compared BMI and age of the study group with negative and positive controls. RESULTS: Thirteen patients presented with sigmoid sinus diverticulum (39.4%) and 20 (60.6%) with sinus wall dehiscence. Thirty ears were successfully treated with surgery (responders), and 3 were not (nonresponders). Responders' mean age was 38 years, with 26 female patients (92.9%) and 2 male (7.1%). BMI of responders compared with nonresponders did not differ significantly (35.5 versus 33.4 kg/m2, p = 0.08). BMI of responders was elevated compared with an asymptomatic control group (35.5 versus 27.4 kg/m2, p < 0.0001). BMI of responders did not differ significantly compared with a cohort of patients with spontaneous CSF otorrhea and temporal bone encephaloceles (35.5 versus 40.7 kg/m2, p = 0.17). CONCLUSION: The patients in this study had elevated BMI and were more likely to be female. This patient population strongly resembles that of patients with IIH, suggesting the possibility that SWA may be a cause of PST in some patients with IIH. Illustrative cases supporting this hypothesis are presented.


Assuntos
Cavidades Cranianas/anormalidades , Cavidades Cranianas/cirurgia , Zumbido/cirurgia , Adulto , Índice de Massa Corporal , Cavidades Cranianas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pseudotumor Cerebral/complicações , Pseudotumor Cerebral/diagnóstico por imagem , Pseudotumor Cerebral/cirurgia , Radiografia , Estudos Retrospectivos , Fatores Sexuais , Zumbido/complicações , Zumbido/diagnóstico por imagem , Resultado do Tratamento
4.
Ophthalmology ; 115(10): 1809-17, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18486224

RESUMO

PURPOSE: To evaluate change from baseline to 12 months follow-up in study and nonstudy (fellow) eye visual fields from the Ischemic Optic Neuropathy Decompression Trial (IONDT). DESIGN: Randomized controlled trial and observational study. PARTICIPANTS: The IONDT enrolled patients >or=50 years with acute nonarteritic ischemic optic neuropathy (NAION). Randomized patients (n = 258) had visual acuity 20/64 or refused randomization. INTERVENTIONS: Optic nerve decompression surgery (n = 127) or careful follow-up (n = 131). MAIN OUTCOME MEASURES: We measured visual fields at baseline and at 6 and 12 months follow-up. Using a computerized system, we classified visual field defects by pattern, location, and severity. We examined changes over time by treatment group, age, baseline comorbidities, and change in visual acuity. In fellow (nonstudy) eyes, we assessed change by whether NAION was present at baseline and also incidence of NAION by whether a visual field defect was present at baseline. RESULTS: We analyzed 245 study eye visual field pairs (179 and 66, randomized and nonrandomized, respectively) for change from baseline to 12 months. We observed significant changes in defect distribution within the central field (P = 0.02) for randomized eyes. Superior and inferior altitudinal defects were less severe at follow-up in both randomized and nonrandomized eyes. We observed an association between change in central field severity and change in visual acuity from baseline (P<0.001 at 6 months; P = 0.01 at 12 months; Kendall's tau-b), but no association between visual field change and treatment group, age, or baseline comorbidities. Superior and inferior visual field defects present at baseline in nonstudy eyes improved at follow-up. Fellow (nonstudy) eyes with normal fields did not have an increased risk of developing NAION compared with eyes with >or=1 defects. CONCLUSIONS: Visual fields of NAION patients enrolled in the IONDT were relatively stable from baseline to follow-up. A visual field defect in the nonstudy eye at baseline was not associated with development of NAION during follow-up compared with eyes with normal fields.


Assuntos
Neuropatia Óptica Isquêmica/fisiopatologia , Campos Visuais/fisiologia , Doença Aguda , Idoso , Descompressão Cirúrgica , Seguimentos , Humanos , Pessoa de Meia-Idade , Neuropatia Óptica Isquêmica/cirurgia , Fatores de Tempo , Acuidade Visual/fisiologia , Testes de Campo Visual
6.
Invest Ophthalmol Vis Sci ; 48(5): 2304-10, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17460295

RESUMO

PURPOSE: Nonarteritic anterior ischemic optic neuropathy (NAION) is an optic nerve infarct involving axons of retinal ganglion cell (RGC) neurons. The rodent NAION model (rAION) can use transgenic mouse strains to reveal unique characteristics about the effects of sudden optic nerve ischemia on RGCs and their axons. The impact of rAION on RGC stress patterns, RGC loss, and their axons after axonal infarct were evaluated. METHODS: A double-transgenic mouse strain was used, containing a construct with cyan fluorescent protein (CFP) under Thy-1 promoter control, and a construct with beta-galactosidase (lacZ) linked to the stress gene c-fos promoter. Thy-1 in the retina is expressed predominantly in RGCs, enabling stereologic analysis of CFP(+) RGC numbers and loss post-rAION-using confocal microscopy. RGC loss was correlated with axonal counts using transmission electron microscopy (TEM). LacZ immunohistochemistry was used to evaluate retinal cell stress after rAION. RESULTS: The 45,000 CFP(+) cells in the RGC layer of control animals compared with previous RGC quantitative estimates. rAION produced RGC stress, defined as lacZ expression, in patterns corresponding with later RGC loss. rAION-associated RGC loss correlated with regional nerve fiber layer loss. Axonal loss correlates with stereologically determined RGC loss estimates in transgenic mice retinas. CONCLUSIONS: Post-ON infarct RGC stress patterns correlate with regional RGC loss. Cellular lacZ levels in most RGCs are low, suggesting rAION-affected RGCs express c-fos only transiently. CFP(+) cell loss correlates closely with quantitative axonal loss, suggesting that the Thy-1 (CFP) transgenic mouse strain is appropriate for RGC stereologic analyses.


Assuntos
Neurônios/patologia , Neuropatia Óptica Isquêmica/patologia , Células Ganglionares da Retina/patologia , Animais , Axônios/metabolismo , Axônios/patologia , Contagem de Células , Morte Celular , Modelos Animais de Doenças , Corantes Fluorescentes/metabolismo , Genes fos/genética , Proteínas de Fluorescência Verde/metabolismo , Imuno-Histoquímica , Infarto/patologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Microscopia Confocal , Neurônios/metabolismo , Nervo Óptico/irrigação sanguínea , Neuropatia Óptica Isquêmica/metabolismo , Células Ganglionares da Retina/metabolismo , Antígenos Thy-1/genética , Transgenes , beta-Galactosidase/metabolismo
7.
BMC Ophthalmol ; 6: 34, 2006 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-17116264

RESUMO

BACKGROUND: The objective of this report is to describe the methods used to develop and validate a computerized system to analyze Humphrey visual fields obtained from patients with non-arteritic anterior ischemic optic neuropathy (NAION) and enrolled in the Ischemic Optic Neuropathy Decompression Trial (IONDT). The IONDT was a multicenter study that included randomized and non-randomized patients with newly diagnosed NAION in the study eye. At baseline, randomized eyes had visual acuity of 20/64 or worse and non-randomized eyes had visual acuity of better than 20/64 or were associated with patients refusing randomization. Visual fields were measured before treatment using the Humphrey Field Analyzer with the 24-2 program, foveal threshold, and size III stimulus. METHODS: We used visual fields from 189 non-IONDT eyes with NAION to develop the computerized classification system. Six neuro-ophthalmologists ("expert panel") described definitions for visual field patterns defects using 19 visual fields representing a range of pattern defect types. The expert panel then used 120 visual fields, classified using these definitions, to refine the rules, generating revised definitions for 13 visual field pattern defects and 3 levels of severity. These definitions were incorporated into a rule-based computerized classification system run on Excel(R) software. The computerized classification system was used to categorize visual field defects for an additional 95 NAION visual fields, and the expert panel was asked to independently classify the new fields and subsequently whether they agreed with the computer classification. To account for test variability over time, we derived an adjustment factor from the pooled short term fluctuation. We examined change in defects with and without adjustment in visual fields of study participants who demonstrated a visual acuity decrease within 30 days of NAION onset (progressive NAION). RESULTS: Despite an agreed upon set of rules, there was not good agreement among the expert panel when their independent visual classifications were compared. A majority did concur with the computer classification for 91 of 95 visual fields. Remaining classification discrepancies could not be resolved without modifying existing definitions. Without using the adjustment factor, visual fields of 63.6% (14/22) patients with progressive NAION and no central defect, and all (7/7) patients with a paracentral defect, worsened within 30 days of NAION onset. After applying the adjustment factor, the visual fields of the same patients with no initial central defect and 5/7 of the patients with a paracentral defect were seen to worsen. CONCLUSION: The IONDT developed a rule-based computerized system that consistently defines pattern and severity of visual fields of NAION patients for use in a research setting.


Assuntos
Descompressão Cirúrgica , Diagnóstico por Computador , Sistemas Inteligentes , Neuropatia Óptica Isquêmica/fisiopatologia , Neuropatia Óptica Isquêmica/cirurgia , Testes de Campo Visual , Campos Visuais , Automação , Progressão da Doença , Humanos , Estudos Multicêntricos como Assunto , Procedimentos Cirúrgicos Oftalmológicos , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença
10.
Invest Ophthalmol Vis Sci ; 44(10): 4153-62, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14507856

RESUMO

PURPOSE: Anterior ischemic optic neuropathy (AION) is caused by sudden loss of vascular supply to retinal ganglion cell (RGC) axons in the anterior portion of the optic nerve and is a major cause of optic nerve dysfunction. There has been no easily obtainable animal model of this disorder. The current study was conducted to design a novel model of rodent AION (rAION), to enable more detailed study of this disease. METHODS: A novel rodent photoembolic stroke model was developed that is directly analogous to human AION. Using histologic, electrophysiological, molecular- and cell biological methods, the early changes associated with isolated RGC axonal ischemia were characterized. RESULTS: Functional (electrophysiological) changes occurred in RGCs within 1 day after rAION, with a loss of visual evoked potential (VEP) amplitude that persisted in the long term. The retinal gene expression pattern rapidly changed after rAION induction, with an early (<1 day) initial induction of c-Fos mRNA, and loss of RGC-specific gene expression. RGC-specific protein expression declined 2 days after detectable mRNA level changes, and immunostaining suggested that multiple retinal layers react to isolated RGC axonal ischemia. CONCLUSIONS: rAION rapidly results in electrophysiological and histologic changes similar to clinical AION, with reactive responses in primary and supporting neuronal cell layers. The rAION model can enable a detailed analysis of the individual retinal and optic nerve changes that occur after optic nerve stroke, which may be useful in determining possible therapeutic interventions for this disorder.


Assuntos
Modelos Animais de Doenças , Potenciais Evocados Visuais/fisiologia , Proteínas de Homeodomínio , Neuropatia Óptica Isquêmica/patologia , Neuropatia Óptica Isquêmica/fisiopatologia , Doenças Retinianas/fisiopatologia , Células Ganglionares da Retina/fisiologia , Animais , Axônios/fisiologia , Proteínas de Ligação a DNA/biossíntese , Proteínas de Ligação a DNA/genética , Regulação da Expressão Gênica , Proteínas de Choque Térmico HSP70/genética , Proteínas de Choque Térmico HSP70/metabolismo , Proteínas de Choque Térmico HSP90/biossíntese , Proteínas de Choque Térmico HSP90/genética , Técnicas Imunoenzimáticas , Masculino , Neuropatia Óptica Isquêmica/metabolismo , Reação em Cadeia da Polimerase , Proteínas Proto-Oncogênicas c-fos/biossíntese , Proteínas Proto-Oncogênicas c-fos/genética , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Doenças Retinianas/metabolismo , Doenças Retinianas/patologia , Células Ganglionares da Retina/metabolismo , Células Ganglionares da Retina/patologia , Opsinas de Bastonetes/biossíntese , Opsinas de Bastonetes/genética , Fator de Transcrição Brn-3B , Fatores de Transcrição/biossíntese , Fatores de Transcrição/genética
11.
Control Clin Trials ; 24(3): 294-305, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12757995

RESUMO

The purpose of this article is to report the methods and results of the surgical quality assurance program associated with the Ischemic Optic Neuropathy Decompression Trial (IONDT). A surgical quality assurance committee developed and implemented a quality assurance program for a randomized clinical trial requiring surgical intervention. A surgical technique questionnaire was administered at two times during the study course, and maintenance of surgeon certification required submission and approval of a masked videotape of an optic nerve sheath decompression surgery by each study surgeon. Surgical quality was assessed through completion of surgical report forms and standardized, masked review of operative notes. Rates of compliance and intra- and interreviewer agreement were assessed for each aspect of the program. Twenty-five of 32 surgeons (81%) successfully completed and maintained certification. Item agreement varied from 21-92% among reviewers of satisfactory videotapes and 22-89% on unsatisfactory videotapes. Intrarater agreement for videotape acceptability was 11 of 13 (85%), and for specific surgical steps, 147 of 182 (81%). Operative notes were submitted for 123 of 125 (98%) patients receiving surgery. Interrater agreement on individual items ranged from 73-100%. Classification of individual items was identical on first and second review for 1285 of 1344 (95.6%) items. Overall agreement for individual reviewers was 93.8-97.8%. We conclude that use of a small peer review committee, which developed and oversaw a quality assurance program, allowed for consistent certification and monitoring of surgical performance. This in turn increased the credibility of the IONDT results, which demonstrated no difference in outcome between operated and unoperated groups of patients.


Assuntos
Certificação/normas , Competência Clínica/normas , Protocolos Clínicos/normas , Neuropatia Óptica Isquêmica/cirurgia , Garantia da Qualidade dos Cuidados de Saúde/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto/normas , Estados Unidos , Gravação de Videoteipe
12.
Surgery ; 133(3): 324-30, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12660647

RESUMO

BACKGROUND: The Ischemic Optic Neuropathy Decompression Trial compared optic nerve decompression surgery with careful follow-up for treatment of patients with nonarteritic ischemic optic neuropathy. Surgeons submitted a standardized data collection form and operative notes for 123 patients randomized to and undergoing surgery. The purpose of this study was to see whether operative notes have sufficient and reliable data to avoid development of a surgery data collection form in future trials. METHODS: We abstracted data from Ischemic Optic Neuropathy Decompression Trial patient operative notes, calculated the proportion of completed responses, and compared abstracted responses with those originally recorded on corresponding case report forms. RESULTS: Variables used to identify persons, dates, or eye (left/right) were reported 100% of the time on operative notes and with excellent agreement with those recorded on the case report form (median agreement, 100%; range, 95% to 100%). Categoric variables, used to establish the characteristics of surgical steps, were also reported reliably on operative notes (median agreement, 84%; range, 0 to 100%). Open-ended variables tended to be reported more frequently on operative notes (exact agreement, 57% and 34%, respectively, for complications and postoperative medications). Quantitative variables were infrequently reported but correlated well with values reported on the data collection forms (Pearson correlation coefficients, 0.78, 0.79, 0.94, 0.96). For many variables, disagreements were minor and often were related to interpretation of the operative notes by the abstractor. CONCLUSION: In our trial, operative note abstraction adequately documented surgery date and surgeon and provided more complete information than the standardized report form with respect to complications but did not provide complete information for other variables.


Assuntos
Indexação e Redação de Resumos/normas , Controle de Formulários e Registros/normas , Prontuários Médicos/normas , Procedimentos Cirúrgicos Oftalmológicos/métodos , Indexação e Redação de Resumos/estatística & dados numéricos , Baltimore , Controle de Formulários e Registros/estatística & dados numéricos , Humanos , Los Angeles , Prontuários Médicos/estatística & dados numéricos , Neuropatia Óptica Isquêmica/cirurgia , Rhode Island
13.
Am J Ophthalmol ; 134(3): 317-28, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12208242

RESUMO

PURPOSE: To examine the prevalence and incidence of second eye nonarteritic anterior ischemic optic neuropathy (NAION) and associated patient characteristics in patients enrolled in the Ischemic Optic Neuropathy Decompression Trial (IONDT) Follow-up Study. DESIGN: Randomized clinical trial with observational cohort. METHODS: Patients randomized to optic nerve sheath decompression surgery or careful follow-up had a diagnosis of acute unilateral NAION, visual acuity between 20/64 and light perception, and were aged 50 years or older. Eligible patients who declined randomization or whose visual acuity was better than 20/64 were not randomized but followed as part of an observational cohort. Follow-up examinations took place at 3, 6, 12, 18, and 24 months and annually thereafter. RESULTS: Four hundred eighteen patients were enrolled; 258 randomized and 160 observed. Previous NAION or other optic neuropathy was present in the fellow eye of 21.1% (88/418) of patients at baseline. Four patients developed optic neuropathy in the fellow eye at follow up that could not be conclusively diagnosed as NAION. New NAION in the fellow eye occurred in 14.7% (48/326) of patients at risk during a median follow up of 5.1 years. Randomized patients experienced a higher incidence (35/201; 17.4%) than nonrandomized patients (13/125; 10.4%). A history of diabetes and baseline visual acuity of 20/200 or worse in the study eye, but not age, sex, aspirin use, or smoking were significantly associated with new NAION in the fellow eye. Final fellow eye visual acuity was significantly worse in those patients with new fellow eye NAION whose baseline study eye visual acuity was 20/200 or worse. CONCLUSIONS: Follow-up data from the IONDT cohort provide evidence that the incidence of fellow eye NAION is lower than expected: new NAION was diagnosed in 14.7% of IONDT patients over approximately 5 years. Increased incidence is associated with poor baseline visual acuity in the study eye and diabetes, but not age, sex, smoking history, or aspirin use.


Assuntos
Descompressão Cirúrgica , Nervo Óptico/cirurgia , Neuropatia Óptica Isquêmica/etiologia , Neuropatia Óptica Isquêmica/cirurgia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Complicações do Diabetes , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Fatores de Risco , Transtornos da Visão/complicações , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA